• Title/Summary/Keyword: 평가 기능

Search Result 8,610, Processing Time 0.038 seconds

Antioxidative Activity of Smilax china L. Leaf Teas Fermented by Different Strains (균주에 따른 청미래덩굴잎 발효차의 항산화 활성)

  • Lee, Sang-Il;Lee, Ye-Kyung;Kim, Soon-Dong;Kang, Yun Hwan;Suh, Joo Won
    • The Korean Journal of Food And Nutrition
    • /
    • v.25 no.4
    • /
    • pp.807-819
    • /
    • 2012
  • To evaluate the functional characteristic and availability for drinking of the fermented Smilax china leaf tea by using different microbial species, various fermented leaf tea was prepared by non-fermentation (C), or the fermentation of Saccharomyces cerevisiae (S), Bacillus sp. (B), Bifidobacterium bifidus (L), Monascus pilosus (M) and Aspergilus oryzae (A), and sensory and antioxidant parameter of each brewed tea was observed. The color of the A tea was red, but the other teas were yellow in color. Furthermore, the aesthetic quality of the A and M tea was 3.95 and 3.30 point, respectively, and other teas (2.55~2.28) were similar to that of the C tea. TP of fermented tea water extract was lower than that of the C, although TF was not significantly different between the fermented and non-fermented tea. Especially, TF of the A tea was significantly lower than those of the other teas. The range of EDA ($1mg/m{\ell}$) of water and ethanol extracts of tea C and the fermented teas was 19.25~22.48%; however, tea A was only 8.04~12.49%. In addition, FRAP, FICA and LPOIA of teas were not significantly different between the fermented and non-fermented teas. On the other hand, XOIA and AOIA of tea ethanol extracts were slightly higher than those of water extracts. XOIA of water extract derived from the teas was 4.83~9.20%, while ethanol extract of these was 9.00~19.00%. However, XOIA of B and L teas water extract was not detected. Furthermore, AOIA of fermented tea water extract (30.17~48.52%) were lower than those of ethanol extract (44.09~66.93%). In this study, interestingly, antioxidant parameters, such as FRAP, FICA, LPOIA and AOIA, of the A tea water extract (0.1%) was higher than that of the other tea in spite of high decreasing rate in the contents of TP and TF. Therefore, above results imply the possibility of fermented Smilax china leaf tea as a functional food.

The Use of Pharmacogenomic Method for the Prediction of Antidepressant Responsiveness (약리 유전학적 방법을 이용한 항우울제 치료반응성의 예측)

  • Kim, Doh Kwan;Lim, Shinn-Won
    • Korean Journal of Biological Psychiatry
    • /
    • v.9 no.1
    • /
    • pp.25-33
    • /
    • 2002
  • Serotonin transporter(5-HTT) is one of the major action site of antidepressants in neuronal cells. According to the recent studies, it is known that the functional polymorphism in the promoter region of the 5-HTT gene(5-HTT linked polymorphism repetitive element in promoter region, 5-HTTLPR) is associated with antidepressant responsiveness, and the distributions of 5-HTTLPR is various among the different populations. Our preliminary study suggested that it is possible to measure the endophenotype of 5-HTTLPR genotype by examining the pharmacodynamic research of the 5-HTT in platelet membranes. However, there are limitations to predicting the antidepressant responsiveness only from the endophenotypic characteristics of 5-HTT gene promoter polymorphism, and therefore we propose to use the pharmacogenomic methods for overcoming these limitations. We found that the significant correlations existed among the genetic polymorphisms of biogenic amine transporters whose structure and characteristics are similar to the 5-HTT, and the predictable odds ratio of antidepressant responsiveness are increased significantly by combining the effect with other associated polymorphisms, compared to the effect of 5-HTT promoter polymorphism only. These results support the hypothesis that antidepressant treatment has to be individualized according to the genetic and ethnic background of depressed patients. It would be possible to develope the evaluation tools to predict the antidepressant responsiveness and its side effect profile, if scientists reveal the genes related to the action mechanism as well as the metabolism of antidepressants so as to discover the interaction of those genes and contribution of endogenotypes toward antidepressant responsiveness.

  • PDF

The Comparison of Glomerular Filteration Rate by Kidney Depth in Dynamic kidney Scan (동적신장검사에서 신장깊이에 따른 사구체여과율 비교)

  • Hwang, Ju-Won;Lim, Young-Hyen;Yun, Jong-Jun;Lee, Hwa-Jin;Lee, Mu-Seok;Jung, Ji-Uk;Park, Se-Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.73-77
    • /
    • 2014
  • Purpose Find out about the significance of the GFR values calculated by the kidney depth is measured by comparing the values obtained for kidney depth was measured GFR in the CT image kidney depth and is calculated by Tonnesen law in $^{99m}Tc$-DTPA dynamic kidney scan with each applies. Materials and Methods Among patients with normal value (75~120 mL/min) computed GFR conducted of dynamic renal scan to visit from February 2013 to February 2014 and donor GFR values in patients with normal value. The mean age was 46.9 years with 14 men 13 females. We used abdomen CT image which checked before conducting dynamic Kidney scan for measuring the depth of kidney. We only used CT image that contains renal hilum and measured outermost front of the kidney from the skin surface (a) and the final surface (b) caculated the average depth of [(a + b) / 2] respectively. Using the same ROI in order to limit the change in GFR values by the other additional element was set before and after the depth value was excluded from the GFR falls kidney disease. Results Using Tonnesen law the average value was caculated 5.94 cm from the right kidney 5.90 cm from the left kidney. It was 6.83 cm, 8.71 cm in the left kidney and the right kidney average value of the depth measured on the basis of the CT image. The respective increase in left kidney 0.93 cm and right kidney 2.77 cm calculated on the basis of CT image actually measured values. GFR was calculated as the average depth of the subject calculated by the method Tonnesen $83.3{\pm}9.79mL/min$. $98.6{\pm}14.07mL/min$ GFR was applied to calculate the average depth of the subjects using the CT image, is the difference appears 15.26 mL/min was increased after seting up depth value, P value was less than 0.01 which is significant. Conclusion The difference between GFR before-after setting up depth value cause that the different of depth value. Is a measured depth of the extension value of the calculated estimates Whereas Tonnesen kidney depth method is to use in calculating the value of GFR in a typical dynamic elongation test depth derived using the CT image depth. Is thought to be able to calculate more accurately the GFR value by the distance to the center of kidney more accurately measured in the skin thereby.

  • PDF

Effects of Dietary Supplementation of Domestic Skullcap (Scutellaria baicalensis) Extracts on Performance, Immune Response and Intestinal Microflora in Broiler Chicken (국내 자생 황금 추출물의 첨가 급여가 육계의 생산성, 면역 기능 및 장내 균총 변화에 미치는 영향)

  • Kwon, H.S.;Kim, J.Y.;Kim, J.S.;Lee, B.K.;Lee, S.Y.;Lee, W.S.;Ahn, B.K.;Kim, E.J.;Kang, C.W.
    • Korean Journal of Poultry Science
    • /
    • v.35 no.4
    • /
    • pp.351-359
    • /
    • 2009
  • This study was carried out to investigate dietary effects of extracts of Skullcap (Scutellaria baicalensis) (SCE) grown in Korea on growth performance, immune and physiological responses in broiler chickens. Total of seven-hundred fifty 1-d-old Ross male broiler chicks were divided into five groups and fed control diets (antibiotics medicated or non-medicated commercial diets) or each experimental diet (non-medicated diets containing 0.1, 0.3 or 0.5% SCE) for 5 weeks. The body weight gain and feed conversion rate in the groups fed diets containing 0.1% or 0.3% SCE were significantly improved as compared with those of non-medicated control group (P<0.05). The levels of total cholesterol and HDL-cholesterol of blood were not influenced by feeding the SCE. The average antibody titers against NDV and IBV in the groups fed diets containing SCE were significantly increased compare to those of the control groups (P<0.05). The number of coli form bacteria was significantly reduced by feeding 0.3% or 0.5% SCE as compared to that of non-medication control (P<0.05). The results demonstrated that the SCE used in this study modulated humoral immunity and the profiles of cecal microflora and thus can be used as a potential alternative substance to replace antibiotics for feeding broiler chicks.

Evaluation to Obtain the Image According to the Spatial Domain Filtering of Various Convolution Kernels in the Multi-Detector Row Computed Tomography (MDCT에서의 Convolution Kernel 종류에 따른 공간 영역 필터링의 영상 평가)

  • Lee, Hoo-Min;Yoo, Beong-Gyu;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.71-81
    • /
    • 2008
  • Our objective was to evaluate the image of spatial domain filtering as an alternative to additional image reconstruction using different kernels in MDCT. Derived from thin collimated source images were generated using water phantom and abdomen B10(very smooth), B20(smooth), B30(medium smooth), B40 (medium), B50(medium sharp), B60(sharp), B70(very sharp) and B80(ultra sharp) kernels. MTF and spatial resolution measured with various convolution kernels. Quantitative CT attenuation coefficient and noise measurements provided comparable HU(Hounsfield) units in this respect. CT attenuation coefficient(mean HU) values in the water were values in the water were $1.1{\sim}1.8\;HU$, air($-998{\sim}-1000\;HU$) and noise in the water($5.4{\sim}44.8\;HU$), air($3.6{\sim}31.4\;HU$). In the abdominal fat a CT attenuation coefficient($-2.2{\sim}0.8\;HU$) and noise($10.1{\sim}82.4\;HU$) was measured. In the abdominal was CT attenuation coefficient($53.3{\sim}54.3\;HU$) and noise($10.4{\sim}70.7\;HU$) in the muscle and in the liver parenchyma of CT attenuation coefficient($60.4{\sim}62.2\;HU$) and noise ($7.6{\sim}63.8\;HU$) in the liver parenchyma. Image reconstructed with a convolution kernel led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image scanned with a high convolution kernel(B80) led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image medications of image sharpness and noise eliminate the need for reconstruction using different kernels in the future. Adjusting CT various kernels, which should be adjusted to take into account the kernels of the CT undergoing the examination, may control CT images increase the diagnostic accuracy.

  • PDF

Development of an Automatic Seed Marker Registration Algorithm Using CT and kV X-ray Images (CT 영상 및 kV X선 영상을 이용한 자동 표지 맞춤 알고리듬 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.54-61
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The purpose of this study is to develop a practical method for determining accurate marker positions for prostate cancer radiotherapy using CT images and kV x-ray images obtained from the use of the on- board imager (OBI). $\underline{Materials\;and\;Methods}$: Three gold seed markers were implanted into the reference position inside a prostate gland by a urologist. Multiple digital image processing techniques were used to determine seed marker position and the center-of-mass (COM) technique was employed to determine a representative reference seed marker position. A setup discrepancy can be estimated by comparing a computed $COM_{OBI}$ with the reference $COM_{CT}$. A proposed algorithm was applied to a seed phantom and to four prostate cancer patients with seed implants treated in our clinic. $\underline{Results}$: In the phantom study, the calculated $COM_{CT}$ and $COM_{OBI}$ agreed with $COM_{actual}$ within a millimeter. The algorithm also could localize each seed marker correctly and calculated $COM_{CT}$ and $COM_{OBI}$ for all CT and kV x-ray image sets, respectively. Discrepancies of setup errors between 2D-2D matching results using the OBI application and results using the proposed algorithm were less than one millimeter for each axis. The setup error of each patient was in the range of $0.1{\pm}2.7{\sim}1.8{\pm}6.6\;mm$ in the AP direction, $0.8{\pm}1.6{\sim}2.0{\pm}2.7\;mm$ in the SI direction and $-0.9{\pm}1.5{\sim}2.8{\pm}3.0\;mm$ in the lateral direction, even though the setup error was quite patient dependent. $\underline{Conclusion}$: As it took less than 10 seconds to evaluate a setup discrepancy, it can be helpful to reduce the setup correction time while minimizing subjective factors that may be user dependent. However, the on-line correction process should be integrated into the treatment machine control system for a more reliable procedure.

Off-Pump Total Arterial Revascularization Using the Skeletonized Right Gastroepiploic Artery as a Third Arterial Conduit; Early and Midterm Results (제3동맥 도관으로서의 골격화된 우위대망동맥을 사용하여 시행한 심폐바이패스를 사용하지 않는 관상동맥 우회술;초기 및 중기 결과)

  • 이현주;최재성;김기봉
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.659-665
    • /
    • 2003
  • The aim of this study was to evaluate the early and midterm results of off-pump total arterial revascularization using the skeletonized right gastroepiploic artery (RGEA) as a third arterial conduit. Material and Method: We prospectively analyzed 103 patients who underwent off-pump total arterial revascularization using bilateral internal thoracic arteries (ITAS) and RGEA. The RGEA was used as in situ graft in 88 patients, composite graft in 10 patients, and free graft in 5 patients. Postoperative coronary angiographies were performed before discharge in 100 patients, and at postoperative one year in 88 patients. Result: The RGEA showed a significantly higher free flow (130$\pm$95 ml/min) than that of right ITA(113$\pm$57 ml/min) or left ITA (107$\pm$55 ml/min), which was measured before anastomosis (p < 0.05). The total number of distal anastomoses was 3.8$\pm$0.7. The number of distal anastomoses per bilateral ITAs was 2.8$\pm$0.7 and the number of distal anastomosis per RGEA was 1.0. There were two morialities including one operative mortality. The late mortality was not related to cardiac events. Early postoperative morbidities were atrial fibrillation in 15 patients, bleeding reoperation in 4 patients, mediastinitis in 1 patients, perioperative myocardial infarction in 2 patient, and transient ARF in 3 patients. Postoperative coronary angiographies showed the early patency rate of 98.6% (272/276) for ITAs and 97.0% (97/100) for RGEA, respectively (p=ns), and the one-year patency rate of 95.9% (234/244) for ITAs and 88.6% (78/88) for RGEA, respectively (p=0.07). Flow competition between the RGEA and NCA (native coronary artery) was seen in 5 of the 100 patients (5.0%) immediate postoperatively and 7 of the 88 patients (8.0%) 1 year after surgery. Since July, 2000, we measured transit time flow intraoperatively and could reduce flow competition significantly Conclusion: The skeletonized RGEA demonstrated excellent early and midterm patency rates and could be used as a third arterial graft following the bilateral ITAs.

Mitral Valve Repair for Congenital Mitral Regurgitation in Children (선천성 승모판막 페쇄부전증이 있는 소아에서 승모판막 성형술에 대한 임상적 고찰)

  • Kim, Kun-Woo;Choi, Chang-Hyu;Park, Kook-Yang;Jung, Mi-Jin;Park, Chul-Hyun;Jeon, Yang-Bin;Lee, Jae-Ik
    • Journal of Chest Surgery
    • /
    • v.42 no.3
    • /
    • pp.292-298
    • /
    • 2009
  • Background: Surgery for mitral valve disease in children carries both technical and clinical difficulties that are due to both the wide spectrum of morphologic abnormalities and the high incidence of associated cardiac anomalies. The purpose of this study is to assess the outcome of mitral valve surgery for treating congenital mitral regurgitation in children. Material and Method: From 1997 to 2007, 22 children (mean age: 5.4 years) who had congenital mitral regurgitation underwent mitral valve repair. The median age of the patients was 5.4 years old and four patients (18%) were under 12 months of age. 15 patients (68%) had cardiac anomalies. There were 13 cases of ventricular septal defect, 1 case of atrial septal defect and 1 case of supravalvar aortic stenosis. The grade of the preoperative mitral valve regurgitation was II in 4 patients, III in 15 patients and IV in 3. The regurgitation was due to leaflet prolapse in 12 patients, annular dilatation in 4 patients and restrictive leaflet motion in 5 patients. The preoperative MV Z-value and the regurgitation grade were compared with those obtained at follow-up. Result: MV repair was possible in all the patients. 19 patients required reduction annuloplasty and 18 patients required valvuloplasty that included shortening of the chordae, papillary muscle splitting, artificial chordae insertion and cleft closure. There were no early or late deaths. The mitral valve regurgitation after surgery was improved in all patients (absent=10, grade I=5, II=5, III=2). MV repair resulted in reduction of the mitral valve Z-value ($2.2{\pm}2.1$ vs. $0.7{\pm}2.3$, respectively, p<0.01). During the mid-term follow-up period of 3.68 years, reoperation was done in three patients (one with repair and two with replacement) and three patients showed mild progression of their mitral reguration. Conclusion: our experience indicates that mitral valve repair in children with congenital mitral valve regurgitation is an effective and reliable surgical method with a low reoperation rate. A good postoperative outcome can be obtained by preoperatively recognizing the intrinsic mitral valve pathophysiology detected on echocardiography and with the well-designed, aggressive application of the various reconstruction techniques.

Implementation and Evaluation of the Electron Arc Plan on a Commercial Treatment Planning System with a Pencil Beam Algorithm (Pencil Beam 알고리즘 기반의 상용 치료계획 시스템을 이용한 전자선 회전 치료 계획의 구현 및 정확도 평가)

  • Kang, Sei-Kwon;Park, So-Ah;Hwang, Tae-Jin;Cheong, Kwang-Ho;Lee, Me-Yeon;Kim, Kyoung-Ju;Oh, Do-Hoon;Bae, Hoon-Sik
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.304-310
    • /
    • 2010
  • Less execution of the electron arc treatment could in large part be attributed to the lack of an adequate planning system. Unlike most linear accelerators providing the electron arc mode, no commercial planning systems for the electron arc plan are available at this time. In this work, with the expectation that an easily accessible planning system could promote electron arc therapy, a commercial planning system was commissioned and evaluated for the electron arc plan. For the electron arc plan with use of a Varian 21-EX, Pinnacle3 (ver. 7.4f), with an electron pencil beam algorithm, was commissioned in which the arc consisted of multiple static fields with a fixed beam opening. Film dosimetry and point measurements were executed for the evaluation of the computation. Beam modeling was not satisfactory with the calculation of lateral profiles. Contrary to good agreement within 1% of the calculated and measured depth profiles, the calculated lateral profiles showed underestimation compared with measurements, such that the distance-to-agreement (DTA) was 5.1 mm at a 50% dose level for 6 MeV and 6.7 mm for 12 MeV with similar results for the measured depths. Point and film measurements for the humanoid phantom revealed that the delivered dose was more than the calculation by approximately 10%. The electron arc plan, based on the pencil beam algorithm, provides qualitative information for the dose distribution. Dose verification before the treatment should be mandatory.

Success rate and marginal bone loss of Osstem USII plus implants; Short term clinical study (Osstem USII plus 임플란트의 단기간 성공률 및 변연골 흡수량 평가)

  • Kim, Sun-Keun;Kim, Jee-Hwan;Lee, Keun-Woo;Cho, Kyoo-Sung;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.206-213
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate the clinical value of Osstem$^{(R)}$ USII plus system implants. Clinical and radiographic data were analyzed for 88 implants placed and functionally loaded for a 12 month period at the Yonsei University Dental Hospital. Materials and Method: Based on the patient's medical records, clinical factors and their effects on implant marginal bone resorption, distribution and survival rate were analyzed. The marginal bone loss was evaluated at implant placement and during a 6 to 12 months functional loading period. The independent sample t-test was used to evaluate the interrelationship between the factors (${\alpha}$=0.05), and one way repeated measures ANOVA was used to compare the amount of marginal bone resorption. Results: The cumulative survival rate for 88 implants was 100%. The marginal bone resorption from implant placement to prosthetic delivery was 0.24 mm and the average marginal bone resorption from prosthetic delivery to 12 months of functional loading was 0.19 mm. The total average bone resorption from implant placement to 12 months of functional loading was 0.43 mm. There were no statistically differences in the amount of marginal bone resorption when implants were placed in the maxilla or the mandible (P>.05), however, implants placed in the posterior areas showed significantly more marginal bone loss than those placed in the anterior areas (P<.05). Conclusion: Based on these results, the short term clinical success rate of RBM surface treated external connection domestic implants showed satisfactory results and the marginal bone loss was in accord with the success criteria of dental implants.