• Title/Summary/Keyword: 편의 보정

Search Result 241, Processing Time 0.022 seconds

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF

Quality Characteristics of Muhwakwa-pyun with Various Starches (전분 종류를 달리한 무화과편의 품질 특성)

  • 김병숙;정미란;이영은
    • Korean journal of food and cookery science
    • /
    • v.19 no.6
    • /
    • pp.783-793
    • /
    • 2003
  • The effects of various kinds of starch (mungbean, potato, corn and a blend of potato and com starch) on the quality characteristics of muhwakwa-pyun were studied according to the storage duration. The sweetness, pH and total acidity of muhwakwa extract were analyzed, as were the Visco/Amylograph viscosity profile and DSC thermodynamic characteristics of starches. For quality characteristics, color difference, instrumental texture characteristics and sensory characteristics were compared. The sweetness of muhwakwa extract was satisfactory but the total acidity was low for Kwa-pyun manufacture. Therefore, its pH was adjusted to 3.4 by adding 10% citric acid with an amount of 1% of total liquid. From the Visco/Amylograph viscosity profile and DSC thermodynamic characteristics of starches, a blend of potato and com starch was found to be easy to cook and form a gel but a little more resistant than the other starches in terms of retrogradatin. Lightness (L) and yellowness (b) of Kwa-pyun increased while its redness (a) decreased by the storage. The color became whiter and the clarity decrease regardless of the kinds of starch, which became obvious after 3 days of storage. The hardness, springiness, adhesiveness and cohesiveness tended to decrease with storage, which was weak in a blend starch. The overall acceptability of Kwa-pyun made with a blend of potato and com starch was evaluated as being the best among the samples tested. Therefore, for traditional kwa-pyun manufacture manufacture mungbean starch might be replaced with a blend of potato and corn starch which is less expensive and easily available in the market nowadays.

Error Budget Analysis of Pseudorange for Improving the GPS Positioning Accuracy (GPS 위치정확도 향상을 위한 의사거리 오차의 분석에 관한 연구)

  • Kim, Yong-Il;Kim, Dong-Hyun;Kim, Byung-Guk
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.4 no.2 s.8
    • /
    • pp.79-90
    • /
    • 1996
  • It is well known that point positioning using a C/A-code receiver is severely biased by errors in pseudorange. This paper shows the procedures of quantitive analysis for several error elements and that some methods to monitor SA(selective availability) of witch process is not opened are proposed. It is possible to verify the effects of SA in the Doppler shift and receiver clock drift variation. Easy methods to reduce SA effects are to fit second order polynomials for the one and a linear function for the other. With periodic autocorrelation functions. SA effects are analyzed and first order Gauss-Markov process parameters are decided.

  • PDF

Differential Patterns of Elderly Farmers and Non-farmers According to Vulnerability to Aging (노화에 대한 취약성 비교에 따른 고령 농업인과 비농업인의 차별적 패턴)

  • Shin, Dabi;Kang, Eun Kyoung
    • Journal of agricultural medicine and community health
    • /
    • v.45 no.3
    • /
    • pp.130-140
    • /
    • 2020
  • 목적: 본 연구는 65세 이상 농업인과 비농업인의 노화에 따른 취약성을 파악하고 차이를 비교 분석하고자 하였다. 방법: 본 연구는 단면 연구로서 강원도에 거주하는 고령의 농업인 29명과 비농업인 25명이 연구에 참여하였다. 노화에 대한 취약성 평가를 위해 노쇠, 신체 구성, 인지·신체 기능, 심리 상태를 검사하였다. 결과: 집단 간 유의한 차이가 있었던 배우자 유무를 보정하여 편 상관 분석한 결과, 농업인에서만 나이와 취약성 요소 간 유의한 상관관계가 있었으며, 편 상관 계수를 비교하였을 때 body mass index(BMI, r = -0.625 vs 0.026, P < 0.01), 우울도(r = 0.521 vs -0.046, P < 0.05)에서 유의한 차이가 있었다. 결론: 고령의 농업인과 비농업인의 노화에 대한 취약성을 비교하였을 때 나이와 취약성 요소 간 유의한 상관관계는 농업인에서만 나타나 비농업인과는 차별적인 패턴을 보였다. 이러한 결과는 농촌의 고령 농업인에 대하여 건강한 노화를 위한 예방 및 관리 전략이 필요함을 시사한다.

Correction of Mean and Extreme Temperature Simulation over South Korea Using a Trend-preserving Bias Correction Method (변동경향을 보존하는 편의보정기법을 이용한 우리나라의 평균 및 극한기온 모의결과 보정)

  • Jung, Hyun-Chae;Suh, Myoung-Seok
    • Atmosphere
    • /
    • v.25 no.2
    • /
    • pp.205-219
    • /
    • 2015
  • In this study, the simulation results of temperature by regional climate model (Reg- CM4) over South Korea were corrected by Hempel et al. (2013)'s method (Hempel method), and evaluated with the observation data of 50 stations from Korea Meteorological Administration. Among the 30 years (1981~2010) of simulation data, 20 years (1981~2000) of simulation data were used as a training data, and the remnant 10 years (2001~2010) data were used for the evaluation of correction. In general, the Hempel method and parametric quantile mapping show a reasonable correction both in mean and extreme climate of temperature. As the results, the systematic underestimation of mean temperature was greatly reduced after bias correction by Hempel method. And the overestimation of extreme climate, such as the number of TN5% and freezing day, was significantly recovered. In addition to that, the Hempel method better preserved the temporal trend of simulated temperature than other bias correction methods, such as the quantile mapping. However, the overcorrection of the extreme climate related to the upper quantile, such as TX5% and hot days, resulted in the exaggeration of the simulation errors. In general, the Hempel method can reduce the systematic biases embedded in the simulation results preserving the temporal trend but it tends to overcorrect the non-linear biases, in particular, extreme climate related to the upper percentile.

Design of 4-Bit TDL(True-Time Delay Line) for Elimination of Beam-Squint in Wide Band Phased-Array Antenna (광대역 위상 배열 안테나의 빔 편이(Beam-Squint) 현상 제거를 위한 4-Bit 시간 지연기 설계)

  • Kim, Sang-Keun;Chong, Min-Kil;Kim, Su-Bum;Na, Hyung-Gi;Kim, Se-Young;Sung, Jin-Bong;Baik, Seung-Hun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.10
    • /
    • pp.1061-1070
    • /
    • 2009
  • In this paper, we have designed TDL(True-time Delay Line) for eliminating beam-squint occurring in active phased array antenna with large electrical size operated in wide bandwidth, and have tested its electrical performance. The proposed TDL device is composed of 4-bit microstrip delay line structure and MMIC amplifier for compensation of the delay-line loss. The measured results of gain and phase versus delay state satisfy the electrical requirements, also P1dB output power and noise figure meet the requirement. To verify the performance of fabricated TDL, we have simulated the beam patterns of wide-band active phased array antenna using the measured results and have certified the beam pattern compensation performance. As a result of simulated beam pattern compensation with respect to the 675.8 mm size antenna which is operated in X-band, 800 MHz bandwidth, we have reduced the beam squint error of ${\pm}1^{\circ}$ with ${\pm}0.1^{\circ}$. So this TDL module is able to be applied to active phase array antenna system.

Bootstrap estimation of the standard error of treatment effect with double propensity score adjustment (이중 성향점수 보정 방법을 이용한 처리효과 추정치의 표준오차 추정: 붓스트랩의 적용)

  • Lim, So Jung;Jung, Inkyung
    • The Korean Journal of Applied Statistics
    • /
    • v.30 no.3
    • /
    • pp.453-462
    • /
    • 2017
  • Double propensity score adjustment is an analytic solution to address bias due to incomplete matching. However, it is difficult to estimate the standard error of the estimated treatment effect when using double propensity score adjustment. In this study, we propose two bootstrap methods to estimate the standard error. The first is a simple bootstrap method that involves drawing bootstrap samples from the matched sample using the propensity score as well as estimating the standard error from the bootstrapped samples. The second is a complex bootstrap method that draws bootstrap samples first from the original sample and then applies the propensity score matching to each bootstrapped sample. We examined the performances of the two methods using simulations under various scenarios. The estimates of standard error using the complex bootstrap were closer to the empirical standard error than those using the simple bootstrap. The simple bootstrap methods tended to underestimate. In addition, the coverage rates of a 95% confidence interval using the complex bootstrap were closer to the advertised rate of 0.95. We applied the two methods to a real data example and found also that the estimate of the standard error using the simple bootstrap was smaller than that using the complex bootstrap.

Effective Porosity Variation of Cement Samples According to Vacuum Pressure and Time (진공의 압력과 시간을 달리할 때 시멘트시험편의 유효공극률 변화)

  • Lee, Sang Kyu;Lee, Tae Jong;Kim, Hyoung Chan
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.163-176
    • /
    • 2012
  • Effective porosity has been measured for cement specimen as a function of vacuum time and pressure in the vacuum saturation process. Six cement specimen are used; three of them are made of the same ratio of cement and sand, the other three are 100% cement mortar, of which average porosity is about 25% and 40%, respectively. Using the 6 samples, measured effective porosities are compared and examined with 5 different vacuum pressures (2, 4, 6, 8, 10 torr) and times (20, 40, 60, 80, 100 minute), respectively. Comparing measured effective porosity from experiments when vacuum time varies from 100 minute to 20 minute with 20 minute step and vacuum pressure is fixed to 10, 6, and 2 torr, average deviation decreases as 0.6, 0.5, and 0.2% respectively. Comparing measured effective porosity from experiments when vacuum pressure varies from 2 torr to 10 torr with 2 torr step and vacuum time is fixed to 100, 60, and 20 minute, average deviation increases as vacuum time decreases. These results can be a background of suggested method of ISRM that describes the vacuum time longer than 60 minute and vacuum pressure higher than 6 torr. In this study, only qualitative discussion can be possible for the effects on the effective porosity by decreasing 20 minute vacuuming time at the same pressure or by decreasing 2 torr of vacuum pressure at the same vacuum time. This is because the sample could not reached to perfectly dried condition even though the sample were dried at $105^{\circ}C$ and following the ISRM suggested method, so that initial water content could not be the same at each experiment.

Automatic Geometric Calibration of KOMPSAT-2 Stereo Pair Data (KOMPSAT-2 입체영상의 자동 기하 보정)

  • Oh, Kwan-Young;Jung, Hyung-Sup
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.2
    • /
    • pp.191-202
    • /
    • 2012
  • A high resolution satellite imagery such as KOMPSAT-2 includes a material containing rational polynomial coefficient (RPC) for three-dimensional geopositioning. However, image geometries which are calculated from the RPC must have inevitable systematic errors. Thus, it is necessary to correct systematic errors of the RPC using several ground control points (GCPs). In this paper, we propose an efficient method for automatic correction of image geometries using tie points of a stereo pair and the Shuttle Radar Topography Mission (SRTM) Digital Elevation Model (DEM) without GCPs. This method includes four steps: 1) tie points extraction, 2) determination of the ground coordinates of the tie points, 3) refinement of the ground coordinates using SRTM DEM, and 4) RPC adjustment model parameter estimation. We validates the performance of the proposed method using KOMPSAT-2 stereo pair. The root mean square errors (RMSE) achieved from check points (CPs) were about 3.55 m, 9.70 m and 3.58 m in X, Y;and Z directions. This means that we can automatically correct the systematic error of RPC using SRTM DEM.

Measuring and Correcting The Compressive Axial Strain of Concrete Cylinders Retrofitted by External Jackets (외부자켓에 의해 보강된 콘크리트 압축시편의 압축변형률 측정 및 보정)

  • Choi, Eun-soo;Lee, Young-Geun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.2 s.54
    • /
    • pp.215-222
    • /
    • 2009
  • In this study, steel and FRP jackets are used to confine concrete cylinders. The FRP jacket behaviors compositely with concrete since there is bonding between them. However, the used steel jacket in this study do not behavior compositely with concrete since there is not an adhesive between them. The steel jackets are attached by external forces and the welding. This study suggests the measuring method of the axial strain for the confined concrete cylinders showing noncomposite behavior with the jackets and the correcting method of the measured strain for the composite-behavior jackets. For the noncomposite-behavior steel jacket, the axial strain of the steel surface does not represent the axial strain of the concrete inside. Also, a compressormeter can not be used. Thus, the two rigid plates at the top and bottom of a cylinder are placed and the distance of the two plates are measured and used for estimating the axial strain of the concrete. For the composite-behavior FRP jacket, the vertical strain measured on the FRP surface can be used for estimating the axial strain of the concrete. However, the vertical strain on the FRP surface contains the tensile strain due to the bulge of the concrete and, thus, the tensile strain should be corrected from the vertical strain. The corrected verticals strains compared with the measured strain or a existing constitute model; the result is satisfactory. The uncorrected stress-strain curves have the potential to under estimate the ductile behavior and the energy-dissipation-capacity of the composite-behavior FRP jackets.