• Title/Summary/Keyword: 펌프손실

Search Result 143, Processing Time 0.024 seconds

Gain and spectra stabilization in erbium-doped fiber amplifier with optical feedback (광 귀환에 의한 erbium 첨가 광섬유 증폭기의 이득과 ASE 스펙트럼 안정화)

  • 김호삼;박희갑
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.291-297
    • /
    • 1994
  • A feedback loop with bandpass filter is introduced in erbium-doped fiber amplifier to clamp the amplifier gain by lasing the amplifier at a selected wavelength. The gain and the ASE (amplified spontaneous emission) output spectra are found to be independent of input signal power and pump power variation so long as the amplifier is lasing. Also they are found to be dependent only on the overall loss of the feedback loop. Even in the case of slowly modulated large signal input, signal distortion due to gain saturation is not observed.served.

  • PDF

Modeling of Engine Intake Pressure for Predicting Braking Performance Affected by Altitude (고도에 따른 제동 성능 예측을 위한 엔진 흡기압 모델링)

  • An, Kwangman;Lee, Jisuk;Park, Jinil;Lee, Jonghwa
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.3
    • /
    • pp.228-233
    • /
    • 2014
  • Reduction of the atmospheric pressure in high altitude affects brake booster system which was operated by the difference between the intake pressure and the atmospheric pressure. So, braking system can not stably perform due to decrease of brake boost pressure. In this study, effects of altitude change on engine intake pressure was analyzed by prediction model of engine intake pressure which was studied previously. And engine intake pressure was simulated by simulation model in various driving conditions and environmental conditions.

Exhaust Noise Reduction of Dry Vacuum Pump (건식 진공 펌프의 배기 소음 저감)

  • Ahn, Young-Chan;Lee, Hae-Jin;Park, Sang-Gil;Lee, You-Yub;Oh, Jae-Eung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.10
    • /
    • pp.950-957
    • /
    • 2007
  • This paper considers acoustic characteristics of silencer within a dry vacuum pump. The main objective is to reduce noise in dry vacuum pump using the new designed silencer. First, SPL and sound intensity are measured for noise source identification and the new model silencer is designed corresponding to noise characteristics. 4-pole parameters are used to predict the transmission loss which is one of the interest characteristics of the new silencer. The calculated transmission loss is then used to change main effective factor and optimal value is selected by using design of experiment. By conducting an experiment, it is proved that the new designed silencer has reduced noise level by 6 dB(A) more than the original one.

Cooling System Design of PM Synchronous Generator for KBP-2000M (KBP-2000M 풍력발전기용 영구자석형 동기발전기의 냉각시스템 설계)

  • Lee, H.G.;Kim, D.E.;Suh, H.S.;Han, H.S.;Jung, Y.G.;Lee, W.W.;Park, K.H.;Chung, C.W.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.315-318
    • /
    • 2006
  • 포항풍력에너지연구소에서는 에너지 관리공단의 지원으로 2004년부터 풍력터빈 KBP-2000M에 사용될 발전기를 개발해 오고 있다. KBP-2000M에 사용되는 발전기는 기어비가 24인 기어박스를 가진 가변속도형식의 발전기이다. 발전기의 직경은 1.87m 이고 축 방향의 길이는 1.288m 로 영구자석을 사용하여 여자하는 형식으로 설계되었다. 이러한 설계는 풍력발전기에서 요구하는 주요 요구조건인 고효율, 고 신뢰성을 만족시키기 위해서 매우 중요하다 이 보고에서는 발전기의 물리설계에서 얻어진 사양을 기준으로 하여 열 해석에서 얻어진 열 손실을 이용하여 냉각시스템 설계를 하였으며 펌프 및 라디에이터 선정에 관해서 논의한다.

  • PDF

Evaporation Heat Transfer and Pressure Drop of R-404A at Low Flow Rates in 9.5 mm O.D. Smooth and Microfin Tubes (낮은 유량에서 외경 9.5 mm 평활관과 마이크로핀관 내 R-404A 증발 열전달 및 압력 손실)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.27-36
    • /
    • 2018
  • A significant amount of studies were performed on evaporation heat transfer and pressure drop in microfin tubes. Most studies, however, focused on the refrigerants used in air-conditioners or heat pumps, and very limited information is available on R-404A, which is used in low temperature refrigeration. In this study, the evaporation heat transfer and pressure drop characteristics of R-404A in a 9.5 mm O.D. microfin tube were investigated for the mass flux range from $80kg/m^2s$ and $200kg/m^2s$. A smooth tube of the same outer dimeter was also tested for comparison. The results showed that the heat transfer enhancement ratio of the microfin tube increased with increasing mass flux and the heat flux decreased. The relative contribution of the convective heat transfer and the heat flux on total heat transfer was attributed to the observed trend. The pressure drops of the microfin tube were slightly (maximum 28%) larger than those of the smooth tube. Existing correlations do not adequately predict the measured heat transfer coefficients of pressure drops, probably due to the test range of the present study, which is outside of the existing correlations.

Performance Improvement of the Hydrostatic Piston Shoe Bearing of an EHA-Piston Pump under Boundary Friction Conditions (EHA 펌프용 피스톤 슈 정압베어링의 경계 마찰 성능 개선)

  • Hong, Y.S.;Kwon, Y.C.;Kim, C.H.;Lee, S.L.;Kim, B.K.;Moon, J.S.;Kim, J.H.
    • Journal of Drive and Control
    • /
    • v.11 no.2
    • /
    • pp.30-35
    • /
    • 2014
  • The pumps of electro-hydrostatic actuators operate most frequently in boundary lubrication speed range, as they compensate for the position control errors as a control element. When conventional swash plate type piston pumps are applied to electro-hydrostatic actuators, the frictional power losses as well as the wear rate of sliding components, such as piston shoes can increase drastically under the boundary friction condition. In this paper, the power losses of the piston shoes were investigated which were engendered by a frictional solid-to-solid contact and leakage flow rate of their hydrostatic bearing. In order to reduce them, DLC-coating was applied to the swash plate and the ball joint of pistons along with its effects were demonstrated. In addition, it was also shown that the wear rate of the piston shoes could be markedly reduced using the DLC-coated swash plate.

A Study on Integrated Air-conditioning System for Electric Vehicle Based 1-ton Class Commercial Vehicle (전기차 기반의 1톤급 상용차용 통합공조 시스템에 관한 연구)

  • Baek, Soo-Whang;Kim, Chul-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.2
    • /
    • pp.361-368
    • /
    • 2019
  • This paper is a study on integrated air-conditioning system for 1-ton class commercial vehicle based on electric vehicle. In the case of an electric commercial vehicle, since the opening and closing of the door is frequently performed in order to get in and out of the cargo, the heat loss largely occurs. Therefore, the heating and cooling load is required to be larger than the electric vehicle. As a result, the energy consumed by the heating and cooling system is larger than the passenger electric car in order to satisfy the heat comfort required by passengers. In order to overcome these disadvantages, we performed research using an efficient integrated air conditioning system. Finally, the design and analysis of a heat pump system for heating and a electrical compressor for cooling need to be proceed to develop a high-efficiency air conditioning system for improving the commerciality of 1 ton-class electric trucks and expanding the industrial ecosystem in the electric truck sector.

A Study on the Difference in Ballasting Time Arising from the Installation of an Ultraviolet Ballast Water Management System on Existing Ships (현존선에 자외선 평형수처리장치 설치로 인한 평형수 처리시간 변화에 관한 연구)

  • Seo, Kil-Cheon;Lee, Kyoung-Woo;Rho, Beom-Seok;Cho, Ik-Soon;Lee, Won-Ju;Pham, Van Chien;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.5
    • /
    • pp.576-585
    • /
    • 2020
  • This study quantitatively investigated the increase in ballasting time through numerical calculations when an ultraviolet (UV) ballast water management system (BWMS) is installed on an existing vessel. The calculation results indicate that the ballasting time of a gas carrier having 55,000 dead weight tonnage was 2.152 hours without installation of the UV BWMS and implementation of a flow control function. Ballasting time increased by 14.2% after installing the UV BWMS, and it increased by 20.4% with both its installation and implementation of a flow control function. If actual conditions are taken into account, ballasting time after installing the UV BWMS is estimated to increase by at least 30% compared with current ballasting time. Therefore, when concerned parties select a UV type BWMS, it is advisable for them to minimize ship operation losses from an increase in ballasting time by considering the capacity of the actual ballast pumps on board and the flow energy loss of the UV BWMS. Additionally, it is recommended that a BWMS with larger capacity, larger pipes, and pipes with inside coatings be used to minimize the increase in ballasting time after installation of the BWMS.

Evaluation the Impact of Installing a Isolation Valve on Condensate System of Nuclear Power Plan (원자력발전소 복수기 수실 차단밸브 설치 영향 평가)

  • Lee, Sun-Ki
    • Journal of Industrial Convergence
    • /
    • v.18 no.4
    • /
    • pp.15-21
    • /
    • 2020
  • Because there are no isolation valves in condensate system of nuclear power plants, circulating water pump was shutdown for the condenser repair. When circulating water pump was shutdown, power plant output decreased about 45%. These output decreasing can minimize by establishing isolation valves. In this paper, evaluated effect to flow conditions change of condensate system, structural integrity of system, condenser pressure of in case of establish isolation valves to condensate system. Results of the evaluation, the flow rate due to the installation of the isolation valve decreased 0.3% when the valve was fully opened and 4.5% when fully closed. In addition, it was found that the vacuum degree of the condenser decreased with decreasing flow rate, but the integrity of the system was maintained.

An experimental study on the improving noise characteristic of hydraulic power unit (유압동력 발생장치의 소음특성 개선을 위한 실험적 연구)

  • Lee, Gi Chun;Lee, Yong Bum
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.6
    • /
    • pp.638-643
    • /
    • 2013
  • Nowadays, the hydraulic power unit (HPU) has been increased its working pressure and enlarged its capacity in order to improve the performance of the hydraulic system, but it produces noise leveled around 110dB(A) during operation. Recently, due to the reinforcement of industrial safety regulations and the requirement of improving work environment, a separated HPU room is installed at outside or underground of the building as to reduce the noise from HPU, but there are also problems of power loss owing its fluid friction of pipe system and of deficient accessibility during its failure accident. In this study, experiment is performed to improve the noise characteristics with installing a soundproof chamber to minimize the power loss and exclude effectively the high leveled noise, which is generated during the power conversion of HPU.