• Title/Summary/Keyword: 펄스에코

Search Result 85, Processing Time 0.024 seconds

Artifacts Improvement by using the Echo Planar Imaging and Pre-Saturation Pulse Band techniques of Reduced Field-Of-View in Breast Magnetic Resonance Imaging Examination (유방 자기공명영상검사에서 감소된 영상영역의 에코평면영상기법과 사전포화기법 사용에 의한 인공물 개선)

  • Lee, Jaeheun;Kim, Hyunjin;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.307-314
    • /
    • 2015
  • This study was conducted in reducing the involuntary motion artifacts because of lungs and heart movements as well as the aliasing artifacts generated during the use of the reduced-FOV EPI technique while performing breast MRI. Performed on a total of 38 obesity female subjects who visited the clinic for pre-examination before surgery within the period from August 1 to November 30, 2014. The 3.0T MRI scanner equipped with a breast scanning coil. Qualitative and quantitative analyses were each used for the evaluation of the acquired images while an Paired T-test and Wilcoxon rank test were performed to check the statistical significance. The variation ratio rose by 15.69% with the additional application of a pre-saturation pulse in the lesion, by 13.72% near the lesion, and 20.63% in the fat and the contrast-to-noise ratio rose by 10.58% in and near the lesion and by 12.03% in the lesion and fat, respectively. there were increases of 22.05% and 21.42% at 0 and 1000 respectively in qulitative evaluation and growth of 16.10% in apparent diffusion coefficient. it showed a statistically significant result(p<0.05) in signal to noise ratio, contrast to noise ratio, diffusion slope coefficient and apparent diffusion coefficient. The involuntary movements artifacts that occur in the phase encoding direction and the aliasing artifacts are considered to be reduced to obtain the best image in the additional use of the pre-saturation pulse as DWI is acquired.

Effect of a Bonding Layer between Electrodes on the Performance of a λ/4-Mode PVDF Ultrasound Transducer (λ/4 모드 PVDF 초음파 트랜스듀서에 있어서 전극 사이의 접합층이 성능에 미치는 영향)

  • Cao, Yonggang;Ha, Kanglyeol;Kim, Moojoon;Kim, Jungsoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.2
    • /
    • pp.102-110
    • /
    • 2014
  • The effect of a bonding layer on the performance of a quarter-wave (${\lambda}/4$) mode PVDF ultrasound transducer having not only a piezoelectric layer but also a non-piezoelectric layer between two electrodes was analyzed. The equivalent circuit of a transmission line model by Kikuchi et al.[Sound of IEICE, 55-A, 331-338 (1981)] was introduced for the analysis. The validity of the model was confirmed by comparison with a KLM model for three postulated adhesion cases of a $80{\mu}m$ thick piezoelectric PVDF film to a copper (Cu) backer. The pulse-echo responses of five PVDF transducers, each fabricated with a different thickness ($5{\mu}m{\sim}20{\mu}m$) of the bonding layer, were measured and the results were compared with those by simulation. The two results were in good agreement with each other and it was noted that the effect of the bonding layer on the performance of the transducer could be analyzed by the Kikuchi model. In detail, the $20{\mu}m$ bonding layer decreased the center frequency and the bandwidth by about 19.7 % and 25.0 %, respectively, and increased the insertion loss by 57.2 %.

Crack Size Determination Through Neural Network Using Back Scattered Ultrasonic Signal (저면산란 초음파 신호 및 신경회로망을 이용한 균열크기 결정)

  • Lee, Jun-Hyeon;Choe, Sang-U
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.1 s.173
    • /
    • pp.52-61
    • /
    • 2000
  • The role of quantitative nondestructive evaluation of defects is becoming more important to assure the reliability and the safety of structure, which can eventually be used for residual life evaluation of structure on the basis of fracture mechanics approach. Although ultrasonic technique is one of the most widely used techniques for application of practical field test among the various nondestructive evaluation technique, there are still some problems to be solved in effective extraction and classification of ultrasonic signal from their noisy ultrasonic waveforms. Therefore, crack size determination through a neural network based on the back-propagation algorithm using back-scattered ultrasonic signals is established in this study. For this purpose, aluminum plate containing vertical or inclined surface breaking crack with different crack length was used to receive the back-scattered ultrasonic signals by pulse echo method. Some features extracted from these signals and sizes of cracks were used to train neural network and the neural network's output of the crack size are compared with the true answer.

An Analysis of Pulse Length Effect on Underwater Simulated Target Strength Estimated Model (수중 모의표적 강도예측 모델의 펄스길이 효과 고찰)

  • 김부일;박명호;권우현
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.2
    • /
    • pp.44-51
    • /
    • 2001
  • This Paper the practical echo signal synthesis model to predict the target strength and signal shape of a submarine for a valuable tool to active sonar engineer. It is based on UTAHID (Underwater TArget by Highlight Distribution) model which is relocated highlight points along to external hull for aspect angle, and synthesized echo signal by modified grouping highlights to internal scatter cloud. Proposed model is analyzed target strength characteristics on various incident pulse length, and synthesis signal signature, target time spreading loss, echo elongation effect and so on. Thus it can be efficiently used in various real systems related to underwater target echo signal synthesis, that is, active sonar, acoustic countermeasure and surveillance system.

  • PDF

Measurements of Ultrasonic Velocity and Attenuation by Signal Processing Techniques in Time and Frequency Domains (시간 및 주파수 영역에서의 신호 처리 기술에 의한 초음파 속도와 감쇠의 측정)

  • Jang, Young-Su;Kim, Jin-Ho;Jeong, Hyun-Jo;Nam, Young-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.2
    • /
    • pp.118-128
    • /
    • 1999
  • There are many ultrasonic measurement methods that are used in nondestructive testing applications. Some typical applications include material property determination, microstructural characterization. and flaw detection. Ultrasonic parameters such as velocity and attenuation are most commonly required in these applications. The accuracy and repeatability of testing results are dependent on both the hardware used to generate and receive the ultrasonic waves and on the analysis software for calculating these parameters. In this study, five analysis algorithms were implemented on a computer for measuring wave speed in a pulse echo. immersion testing configuration. In velocity measurements comparisons were made between the overlap. cross-correlation. Fourier transform. Hilbert transform, wavelet transform algorithms. Velocity measurement was applied to an isotropic steel sample using the five analysis algorithms. Frequency-dependent phase/group velocity and attenuation were also measured using the Fourier transform and wavelet transform algorithms on a composite laminate containing voids.

  • PDF

MR Imaging of Slow-flow Using a Flow Phantom (유동모형을 이용한 저속유동의 자기공명영상)

  • Dae-Cheol Cheong;Kyung-Jae Jung;Young-Hwan Lee;Nak-Kwan Sung;Duck-Soo Chung;Ok-Dong Kim;Jong-Ki Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.2
    • /
    • pp.116-122
    • /
    • 2001
  • Purpose : To find sensitivity of MRI imaging methods to slow flow phantom study was performed with conventional Spin-Echo, gradient echo based Phase Contrast, fast GRASS, and heavily T2-weighted Fast Spin Echo pulse sequences. Materials and Methods : A siphon driven flow phantom was constructed with a ventriculo-peritoneal shunt catheter and a GE phantom to achieve continuous variable flow. Four different pulse sequences including Spin-Echo, Phase Contrast, GRASS and Heavily T2-weighted Fast Spin Echo were evaluated to depict slow flow in the range from 0.08 ml/min to 1.7 ml/min and to compare signal intensities between static fluid and flowing fluid. Results : In the slow flow above 0.17 ml/min conventional Spin-Echo showed superior apparent contrast between static and flowing fluid while GRASS was more sensitive to the very slow flow below 0.17 ml/mim. It was not accurate to calculate flow and velocity below 0.1 ml/min with a modified PC imaging. Conclusion : Four different MR pulse sequences demonstrated different sensitivity to the range of slow flow from 0.08 ml/min to 1.7 ml/min. This finding may be clinically useful to measure CSF shunt flow or detecting CSF collection and thrombosis.

  • PDF

Visibility Enhancement of the Ultrasonic Signal Reflected from Adhesive Layers (접착층에서 반사된 초음파 신호의 가시도 개선)

  • Shin, Jin Seob;Lee, Jeong-Ihll
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.6
    • /
    • pp.153-157
    • /
    • 2008
  • Recently, electronic devices is produced by multilayer structure, therefore analysis for hidden layers is important nondestructive inspection. This paper presents visibility enhancement methods for the ultrasonic multiple echoes reflected from adhesive layer in the multilayers using digital signal processing. The reflected signals from the multilayers come out interval of the peaks in the power cepstrum. In the experiment, the adhesive layers of settled thickness using epoxy were formed. The reflected signals from the multilayer is detected by pulse-echo method and power cepstrum is processed for enhancement of visibility.

  • PDF

Logic design of the Flaw Evaluation in the Rolling stock axle for Phassed Array ultrasonic inspection method (위상배열 초음파 탐상방식에 의한 차측 결함평가용 논리설계)

  • Kim, Hi-Yooung;Lee, Hung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.98-105
    • /
    • 2008
  • 철도차량 차축의 초음파 탐상은 기존 펄스-에코방식을 사용하여 A-Stan으로 영상화하여 결함평가가 이루어 졌다. 하지만 이 방법은 작업자의 판단에 의존하므로 신뢰성이 멀어졌다. 위상배열 초음파 탐상 검사는 단일 탐촉자에 여러개의 진동자를 배열하여 여러 각도에서 탐상이 가능하므로 차축처럼 종류 및 모양이 다양한 구조물의 탐상에 효과적이다. 또한 C-Scan방식으로 영상화 하므로써 작업자가 결함을 판단하는데 있어서 객관적인 평가방법이다. 이 논문에서는 위상배열 초음파 탐상 검사에 대하여 설명하고 차축결함평가를 위한 자동화된 설비의 논리설계를 분석하고 그 실험의 방법과 결과론 고찰하고자 한다.

  • PDF

Detection of Tool Wear by Using the Ultrasonic In-Process Sensor (초음파 인프로세스 센서를 이용한 공구마멸 검출)

  • Kang, H.S.;Hwang, J.;Ko, B.J.;Chung, E.S.
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.3
    • /
    • pp.55-60
    • /
    • 2001
  • A technique on the detection of tool wear based on the ultrasonic pulse-echo method in turning process is presented. The change in amount of the reflected energy from nose and flank of the tool can be related to the level of tool wear and mechanical integrity of the tool, that is, there exists an excellent correlation between the ultrasonic measurement and tool wear. As a results, the method is very useful for the prediction of cutting tool life and the determination of tool exchange period.

  • PDF

A Study on Suppression of Ultrasonic Background Noise Signal using wavelet Transform (Wavelet변환을 이용한 초음파 잡음신호의 제거에 관한 연구)

  • 박익근
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.1
    • /
    • pp.135-141
    • /
    • 1999
  • Recently, advance signal analysis which is called "Time-Frequency Analysis" has been developed. Wavelet and Wigner Distribution are used to the method. Wavelet transform(WT) is applied to time-frequency analysis of waveforms obtained by an ultrasonic pulse-echo technique. The Gabor function is adopted as the analyzing wavelet. Wavelet analysis method is an attractive technique for evolution of material characterization evoluation. In this paper, the feasibility of suppression of ultrasonic background noise signal using WT has been presented. These results suggest that ultrasonic background noise ginal can be suppressed and enhanced even for SNR of 20.8 dB. This property of the WT is extremely useful for the detecting flaw echos embedded in background noise.und noise.

  • PDF