• Title/Summary/Keyword: 파라메터 측정기

Search Result 6, Processing Time 0.023 seconds

A New PMU (parametric measurement unit) Design with Differential Difference Amplifier (차동 차이 증폭기를 이용한 새로운 파라메터 측정기 (PMU) 설계)

  • An, Kyung-Chan;Kang, Hee-Jin;Park, Chang-Bum;Lim, Shin-Il
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.21 no.1
    • /
    • pp.61-70
    • /
    • 2016
  • This paper describes a new PMU(parametric measurement unit) design technique for automatic test equipment(ATE). Only one DDA(differential difference amplifier) is used to force the test signals to DUT(device under test), while conventional design uses two or more amplifiers to force test signals. Since the proposed technique does not need extra amplifiers in feedback path, the proposed PMU inherently guarantees stable operation. Moreover, to measure the response signals from DUT, proposed technique also adopted only one DDA amplifier as an IA(instrument amplifier), while conventional IA uses 3 amplifiers and several resistors. The DDA adopted two rail-to-rail differential input stages to handle full-range differential signals. Gain enhancement technique is used in folded-cascode type DDA to get open loop gain of 100 dB. Proposed PMU design enables accurate and stable operation with smaller hardware and lower power consumption. This PMU is implemented with 0.18 um CMOS process and supply voltage is 1.8 V. Input ranges for each force mode are 0.25~1.55 V at voltage force and 0.9~0.935 V at current force mode.

Estimation Technique of Power Transmission Line Parameter by Phasor Measurement Units (송전선로 파라메터 정밀 예측을 위한 페이저 측정기의 응용)

  • Cho, Ki-Seon;Park, Jong-Bae;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.193-195
    • /
    • 2003
  • This paper presents an approach to estimate the power transmission line parameter by phasor measurement units(PMUs), which are synchronized to 1 pps signal of GPS. Existing approaches to estimate power transmission line parameter, are mainly off-line ones, based on faults or switching events on other neighboring lines. In this paper, to obtain static and dynamic properties of power transmission line parameter in service, the prototype of pmu-based Transmission Line Parameter Monitoring System (TLPMS) is proposed. Also, an technique to estimate parameters of transmission line described as 2-port network model and the soundness of estimated parameters are addressed.

  • PDF

A Development of Ship Block Leveling System based on the Axiomatic Design (공리적 설계 기반 선체 블록 레벨링 시스템 개발)

  • Noh, Jackyou;Lim, Nam-Won;Oh, Jung-Keun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.2
    • /
    • pp.207-214
    • /
    • 2015
  • In this paper the independence axiom, one of two principal axioms of axiomatic design theory, is applied to the leveling system development as an design criteria. After functional requirements and corresponding design parameters constitute an initial design matrix for the leveling system, sequence, which is compatible with the independence axiom, of the design parameters of the design matrix is determined and independent components of block leveling system are revealed. As a result of axiomatic design, system configuration related to the design sequence is developed. In order to verify and validate the developed block leveling system, test with real hull block leveling work in site by using total station which is used to acquire three dimensional coordinate of target point is performed. Comparison with measured data and output data from the block leveling system shows the system accuracy is under 1 mm so that the developed system is verified and validated to be used in site.

Meaurement Algorithms for EDGE Terminal Performance Test (EDGE 단말기 성능 테스트를 위한 측정 알고리즘)

  • Kang, Sung-Jin;Hong, Dae-Ki;Kim, Nam-Yong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2719-2730
    • /
    • 2009
  • In this paper, we implement the measurement functionality for performance measurements of EDGE (Enhanced Data Rates for GSM Evolution) terminal by using software. Generally speaking, the receiving algorithms in normal MODEM cannot be used directly to a measurement system due to the lack of accuracy. Therefore, we propose a new receiver algorithm for precise EDGE signal measurements. In the proposed algorithm, 2-stage (coarse stage, fine stage) parameters estimation (symbol-timing, frequency offset, carrier phase) scheme is used. To improve the estimation accuracy, we increase the number of the received signal samples by interpolation. The proposed EDGE signal measurement algorithm can be used for verifying the hardware measurement system, and also can be used for the commercial systems through software optimization.

Physical and Mechanical Characteristics of Subgrade Soil using Nondestructive and Penetration Tests (비파괴시험과 관입시험에 의한 노상토의 물리·역학적 특성)

  • Kim, Kyu-Sun;Kim, Dong-Hee;Fratta, Dante;Lee, Woojin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1C
    • /
    • pp.19-27
    • /
    • 2011
  • This paper evaluates the applicability of wave-based nondestructive methodologies and a penetration test for compaction quality measurements during road construction. To evaluate the physical and mechanical properties of compacted subgrade soil layers, soil stiffness gauge (SSG), time domain reflectometry (TDR), and miniature electro-mechanical systems (MEMS) accelerometers were used to nondestructively evaluate the soil response during and after compaction and dynamic cone penetrometer (DCP) profiles were used to evaluate the soil shear strength after compaction was completed. At the field site, two types of soils were compacted with four different compaction equipments and energies. Field testing results indicate that soil parameters evaluated by different testing methods, which are SSG, TDR, MEMS accelerometer, and DCP, are highly correlated. In addition, it is shown that the physical and mechanical tests deployed in this study can be used as alternative methods to the conventional compaction quality evaluation methods when assessing the overall quality and the engineering response of compacted lifts.

A Fault Detection System Design for Boiler-Turbine Control System of Thermal Power Pant (화력발전소 보일러-터빈 제어시스템의 고장검출시스템 설계)

  • Yoo, Seog-Hwan
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.6
    • /
    • pp.615-620
    • /
    • 2015
  • This paper deals with a fault detection system design for a boiler-turbine control system of thermal power plant. We described the nonlinear properties of the boiler-turbine dynamics as a T-S fuzzy system with time varying measurable parameters. We design a residual generator using an observer based fault detection filter. In order to identify the faulted output sensor, an approximate inverse system is connected to the outport of the fault detection filter. We demonstrate the efficiency of the suggested design method via computer simulations.