• Title/Summary/Keyword: 특성방사선

Search Result 1,723, Processing Time 0.027 seconds

Effect of the Radiation Crosslinking and Heating on the Heat Resistance of Polyvinyl Alcohol Hydrogels (PVA 하이드로겔의 내열특성에 방사선 가교와 열처리가 미치는 효과)

  • Park, Kyoung Ran;Nho, Young Chang
    • Applied Chemistry for Engineering
    • /
    • v.16 no.3
    • /
    • pp.354-360
    • /
    • 2005
  • Polyvinyl alcohol (PVA) hydrogels were prepared by the irradiation and heating. Irradiation and heating processes were carried out to improve the heat resistance of PVA hydrogels at high temperature. The physical properties such as gel content, degree of swelling and gel strength for the synthesized hydrogels were examined. The structure variations were investigated using the following techniques: differential scanning calorimetry (DSC) and X-ray diffraction (XRD). Gel content and gel strength of the hydrogels were higher when the two steps of irradiation followed by heat treatment were used rather than only with the irradiation. The hydrogels prepared by the irradiation and the two steps had good heat resistance at high temperature.

Study on the Chemical and Radiation Crosslinking of Poly(vinyl alcohol) Hydrogels for an Improvement of Heat Resistance (내열특성 개선을 위한 폴리(비닐 알코올) 수화젤의 화학 가교와 방사선 가교에 관한 연구)

  • Park, Kyoung-Ran;Nho, Young-Chang
    • Polymer(Korea)
    • /
    • v.29 no.1
    • /
    • pp.91-95
    • /
    • 2005
  • The PVA hydrogels were prepared by the chemical and irradiation method to improve the heat resistance of these hydrogels at the high temperature. The physical properties such as the gel content, the degree of swelling and the gel strength for the synthesized hydrogels were examined. Gel content increased as the chemical reaction time and the irradiation dose increased, and gel content of the hydrogels were higher when the two-steps of chemical and irradiation method were used rather than only the chemical method. Gel strength increased as the chemical reaction time increased, and as the irradiation dose decreased. The hydrogels prepared by the chemical reaction for 5 hours and the two-steps had the heat resistance at the high temperature.

Fabrication and characteristics of Hybrid-type radiation detector using $HgI_2$ (혼합형 구조를 적용한 $HgI_2$ 기반의 방사선 센서 제작 및 특성)

  • Jang, K.Y.;Kang, H.G.;Lee, G.H.;Kim, S.Y.;Park, J.K.;Choi, H.K.;Nam, S.H.;Lim, J.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.460-463
    • /
    • 2004
  • 본 논문은 고에너지 방사선 검출을 위한 흔합형 구조의 방사선 센서를 제작, 반응 특성을 평가하였다. 먼저, 스크린 인쇄법을 이용하여 형광체 필름을 제작하였으며, 발광스펙트럼(PL, Photoluminescence) 및 잔광 시간(decay time) 측정을 통하여 형광체의 발광 특성을 조사하였다. 제작된 혼합구조의 방사선 센서는 $2{\mu}m$ 두께의 $HgI_2$$150{\mu}m$ 두께의 형광체 필름으로 제작되었으며, 면적은 $2\;cm\;{\times}\;2\;cm$이다. 방사선에 대한 전기적 검출 신호의 특성을 조사하기 위해 인가전압에 따른 암전류 및 방사선민감도, 선량에 따른 검출신호를 측정하였다. 측정결과, 제작된 $HgI_2$ 필름은 방사선에 의해 형광체에서 방출된 가시광 파장을 잘 흡수하였으며, 진단영역의 저에너지 방사선에 의해 직접 전기적 신호를 발생시켜 높은 방사선 민감도를 보였다. 뿐만 아니라, 인가전압에 대해 $10\;pA/mm^2$이하의 낮은 암전류를 가졌으며, 넓은 조사선량에서 우수한 선형성을 보였다.

  • PDF

방사선 조사가 신선 돈육의 특성에 미치는 영향

  • 이윤진;이경애
    • Proceedings of the Korean Society of Food and Cookery Science Conference
    • /
    • 2003.10a
    • /
    • pp.79-79
    • /
    • 2003
  • 돈육은 상업적 조사가 허용되어 있는 대표적 식품으로 FDA는 신선육과 냉동육의 최대조사량을 각각 4.5 kGy, 7 kGy로 규정하고 있다. 돈육에 방사선을 조사하면 수분이 이온화되어 생성된 자유 라디칼이 돈육성분과 반응하게 되어 돈육의 외관, 텍스쳐 등에 변화를 일으킨다. 돈육의 색깔, 냄새 등은 신선 돈육의 구매여부를 결정하는 중요한 특성으로 방사선 조사에 의한 육류의 품질 특성 변화는 조사 돈육의 소비에 많은 영향을 미칠 것으로 생각된다. (중략)

  • PDF

A Study On Radiation Detection Using CMOS Image Sensor (CMOS 이미지 센서를 사용한 방사선 측정에 관한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.19 no.2
    • /
    • pp.193-200
    • /
    • 2015
  • In this paper, we propose the radiation measuring algorithm and the device composition using CMOS image sensor. The radiation measuring algorithm using CMOS image sensor is based on the radiation particle distinguishing algorithm projected to the CMOS image sensor and accumulated and average number of pixels of the radiation particles projected to dozens of images per second with CMOS image sensor. The radiation particle distinguishing algorithm projected to the CMOS image sensor measures the radiation particle images by dividing them into R, G and B and adjusting the threshold value that distinguishes light intensity and background from the particle of each image. The radiation measuring algorithm measures radiation with accumulated and average number of radiation particles projected to dozens of images per second with CMOS image sensor according to the preset cycle. The hardware devices to verify the suggested algorithm consists of CMOS image sensor and image signal processor part, control part, power circuit part and display part. The test result of radiation measurement using the suggested CMOS image sensor is as follows. First, using the low-cost CMOS image sensor to measure radiation particles generated similar characteristics to that from measurement with expensive GM Tube. Second, using the low-cost CMOS image sensor to measure radiation presented largely similar characteristics to the linear characteristics of expensive GM Tube.

Acquisition of Monochromatic X-ray Using Multilayer Mirror (다층박막 거울을 이용한 단색 엑스선 획득)

  • Chon, Kwon-Su
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.179-184
    • /
    • 2010
  • A hard X-ray microscope system for obtaining images of nano-spatial resolution has been widely studied and requires monochromatic X-ray. A multilayer mirror of 84% reflectivity was designed to acquire tungsten characteristic X-ray of 8.4 keV from the white beam generated from an X-ray tube, and the C/W multilayer mirror of $50{\times}50\;mm$ size and 5.65 nm d-spacing was fabricated by the ion-beam sputtering system. The C/W multilayer had a uniformity of 99.5%, and the structure of the multilayer mirror was verified by a TEM image. The obtainable x-ray reflectivity for the C/W multilayer mirror at 8.4 keV was estimated from measuring the X-ray reflectivity using the copper characteristic X-ray of 8.05 keV. Monochromatic X-ray of 8.4 keV was generated by combining a X-ray tube, and the reflectivity and monochromaticity were 77.1% and 0.21 keV, respectively. Monochromatic X-ray generated from the combination of an X-ray tube and an C/W multilayer mirror has enough potential to use X-ray source for hard X-ray microscope system of laboratory size. If the C/W multilayer mirror of d-spacing of a few nanometers can be fabricated, monochromatic X-ray corresponded to 17.5 keV, molybdenum characteristic X-ray, can be obtained and applied to mammography in the medical application.

Polygonal Model Analysis on Occupational Exposure Record of Radiation Workers by Work Field (업종별 방사선작업종사자 피폭 기록 다각형 모델 분석 연구)

  • Je-Wan Park;Ji-Young Han;Yong-Min Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.277-284
    • /
    • 2023
  • Since the radiological risk is different depending on the working environment, protection measures and policies must be developed through analysis of the field area environment. Evaluating the characteristics of the field area that uses radiation should be conducted through comparative analysis with other industries, not just the numerical value of the field area. In this study, evaluation factors were derived from exposure records by the department to compare radiation occupational exposure records by sector. And then, we developed a polygonal model for comparative analysis and applied them to eight work fields through ten evaluation factors. Based on the occupational exposure record in 2020, a polygonal model was applied to compare and evaluate the characteristics of the radiation work area. Through this, the usefulness of the polygonal model was confirmed, and protection policy measures for the industry were proposed.

Analysis of Radiation Fusion Shielding Performance of Ytterbium Oxide, a Radiation Impermeable Substance (방사선 불투과성 물질 산화이테르븀(Ytterbium oxide)의 방사선 융합 차폐성능 분석)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.4
    • /
    • pp.87-94
    • /
    • 2021
  • While the shielding substances of radiation shields in medical institutions are beginning to be replaced by environmentally friendly materials, radiation protection according to the shielding properties of environmentally friendly substances is becoming an important factor rather than the existing lead shielding properties. Tungsten and barium sulfate are representative shielding materials similar to lead, and are made in sheets or fiber form with eco-friendly materials. Ytterbium is an impermeable material used as a fluorine compound in the dental radiation field. This study aims to evaluate the shielding performance in the x-ray shielding area by comparing the shielding properties of ytterbium by energy band and that of existing eco-friendly materials. When three types of shielding sheets were fabricated and tested under the same process conditions, the shielding performance of the medical radiation area was about 5 % difference from tungsten. Furthermore, shielding performance was superior to barium sulfate. In the cross-sectional structure of the shielding sheet, there was a disadvantage that the arrangement of particles was not uniform. Ytterbium oxide showed sufficient potential as a medical radiation shielding material, and it is thought that it can improve the shielding performance by controlling the particle arrangement structure and particle size.

Study on Knowledge and Safety Management of Radiation Workers (방사선작업종사자의 방사선 지식정도와 안전관리에 대한 연구)

  • Kim, Wook;Choi, Nam-Gil;Han, Jae-Bok;Song, Jong-Nam
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.4
    • /
    • pp.243-248
    • /
    • 2014
  • This study has been carried out to find out current status of understanding radiation safety expertise by workers under the present training scheme and to minimize radiation risks at work as well as to refurbish training systems for mitigation of uneasiness of the people at large in near future. Questionnaire survey asking 30 items was carried out during 3 months from May to July, 2013. The number of the overall respondents were about 500. Overall scores of hath degree of the basic knowledge and of the attitude related with radiation safety could he procured through analysis of the questionnaire data. Results were as followings: The workers of the higher academic level, the larger of the accumulated training time and the worker's personal antecedents, the more accredited license holders showed the larger scores of the basic knowledge of radiation as well as the attitude related with the radiation safety. The group having higher basic knowledge also showed the higher score in attitude related with radiation safety. The overall scores obtained from the radiation workers in industrial sector were relatively lower, in general, than those of the other sectors. These results suggest that the training program might better be separately implemented. A specific training program implementation might be desirable particularly for the workers in industrial sectors so as not only to reduce radiation risks of workers but also to mitigate the uneasiness arising among the people at large.