• Title/Summary/Keyword: 투수성 단열

Search Result 44, Processing Time 0.028 seconds

Program Development to Evaluate Permeability Tensor of Fractured Media Using Borehole Televiewer and BIPS Images and an Assessment of Feasibility of the Program on Field Sites (시추공 텔리뷰어 및 BIPS의 영상자료 해석을 통한 파쇄매질의 투수율텐서 계산 프로그램 개발 및 현장 적용성 평가)

  • 구민호;이동우;원경식
    • The Journal of Engineering Geology
    • /
    • v.9 no.3
    • /
    • pp.187-206
    • /
    • 1999
  • A computer program to numerically predict the permeability tensor of fractured rocks is developed using information on discontinuities which Borehole Televiewer and Borehole Image Processing System (BIPS) provide. It uses orientation and thickness of a large number of discontinuities as input data, and calculates relative values of the 9 elements consisting of the permeability tensor by the formulation based on the EPM model, which regards a fractured rock as a homogeneous, anisotropic porous medium. In order to assess feasibility of the program on field sites, the numerically calculated tensor was obtained using BIPS logs and compared to the results of pumping test conducted in the boreholes of the study area. The degree of horizontal anisotropy and the direction of maximum horizontal permeability are 2.8 and $N77^{\circ}CE$, respectively, determined from the pumping test data, while 3.0 and $N63^{\circ}CE$ from the numerical analysis by the developed program. Disagreement between two analyses, especially for the principal direction of anisotropy, seems to be caused by problems in analyzing the pumping test data, in applicability of the EPM model and the cubic law, and in simplified relationship between the crack size and aperture. Aside from these problems, consideration of hydraulic parameters characterizing roughness of cracks and infilling materials seems to be required to improve feasibility of the proposed program. Three-dimensional assessment of its feasibility on field sites can be accomplished by conducting a series of cross-hole packer tests consisting of an injecting well and a monitoring well at close distance.

  • PDF

Hydrogeology and Vulnerability of Groundwater Contamination of a Mountainous Area in Kangwon Province (강원도 흥호리 지역 암반대수층의 수리지질 및 지하수 오염취약성 예비조사)

  • 이진용;이강근;정형재;배광옥
    • The Journal of Engineering Geology
    • /
    • v.10 no.1
    • /
    • pp.27-38
    • /
    • 2000
  • We hydrogeologically studied a mountainous area and its vulnerability to groundwater contamination. Groundwater flow and recharge occur mainly through a network of fractures in this areaTransmissivity and storativity obtained from slug, slug interference, and pumping tests range from 3.2$\times$10$^{-3}$ to 2.0$\times$10$^{-2}$$m^2$/min and 1.3$\times$10$^{-7}$ to 9.15$\times$10$^{-4}$, respectively. The groundwater was contaminated bylivestock activities in the upgradient. The groundwater in the downgradient residential area wasthreatened by the upgradient livestock activities.

  • PDF

Characterization of a groundwater system by subsurface hydrogeological investigation data (지하공동굴착 시 수리지질조사 자료를 이용한 저장공동 심도의 지하수체계 특성 연구)

  • 조성일;김천수;김경수;송무영;전한석
    • The Journal of Engineering Geology
    • /
    • v.14 no.1
    • /
    • pp.93-104
    • /
    • 2004
  • This paper intended to assess the hydro-structure characteristics of volcanic rocks based on the hydrogeological data obtained from the underground storage cavern during construction. The variation of groundwater levels was periodically measured from the 28 surface monitoring holes(NX size) and the hydraulic pressures and injection rates were daily monitored from the water curtain holes(95 horizontal holes and 63 vertical holes). The hydraulic interference tests were performed in whole water curtain holes. The distribution patterns of hydraulic pressure are closely related to the dip angles of fracture intersected to the water curtain holes. Three domains can be grouped by the distribution of hydraulic pressures in the horizontal water curtain holes. The initial hydraulic pressures measured immediately after drilling of water crutain holes are high in ascending order of the cavern C-2, C-1, and C-3. The priliminary hydrochemical data also indicate that the portions of the deep groundwater composition is relatively great in the cavern C-3 area. Some of the horizontal water curtain holes in the cavern C-3 show a steady higher groundwater pressure with the composition of shallow groundwater indicating the outer boundary as constant hydraulic boundary. The water curtain holes in the cavern C-2 is characterized as low initial hydraulic pressure and less injection rates, suggesting poor hydraulic connectivity to a shallow groundwater system. The results of the study can help to understand a hydraulic compartment concept in a fracture hydro-geology and be utilized during the surface investigation for a groundwater system.

A Study on the Applicability of the Hydraulic Test Method Performed at an underground Research Facility in Crystalline Rock (결정질 암반내 지하연구시설에서 수행한 현장수리시험법 적용성 연구)

  • Park, Kyung-Woo;Ko, Nak-Yeol;Ji, Sung-Hoon
    • Economic and Environmental Geology
    • /
    • v.53 no.2
    • /
    • pp.121-131
    • /
    • 2020
  • In this paper, the transmissivities obtained from the pulse test, the slug test and the constant head test were compared each other to assess an applicability and a reliability of the hydrogeological test method, which are commonly used to derive the hydrogeological properties of a crystalline rock at un underground research facility. When comparing the results of the pulse test and the slug test, the transmissivities were very similar in the entire test section of the medium. However, there was a little discrepancy in the results in the areas where the permeability is relatively high. The results of the constant head test on the same section showed the lower transmissivity than the results of the pulse test and the slug test on the highly permeable section. This difference in permeability was considered to be due to the difference in the radius of the hydraulic effect applied in each hydraulic test. When the heterogenetic distribution of fracture affects the hydrogeological properties on crystalline rock, it is believed that the hydrogeological characteristics can be explained through a constant head test or a constant flow rate test with a large hydraulic effective radius, as well as a pulse and a slug test that can identify hydrogeological properties in a relatively short time.

Estimation of Conductivity Tensor of Fractured Rocks from Single-hole Packer test (단정 주입시험 결과를 이용한 단열암반의 수리전도도 분석)

  • 장근무;이은용;김창락;이찬구;김현주
    • The Journal of Engineering Geology
    • /
    • v.10 no.1
    • /
    • pp.13-25
    • /
    • 2000
  • A three-dimensional discrete fracture network model based on probabilistic characteristics of fracture geometry and transmissivity was designed to calculate the conductivity tensor and to estimate theanisotropy of conductivity. The conductivities, $K_p$, obtained from the numerical simulation of single-holepacker test corresponded well to those from the field tests. From this, it can be concluded that thefracture network model designed in this study can represent hydraulic characteristics of in-situ fractured rock mass. Block-scale conductivities, $K_b$, estimated from the modelling of steady-state flow through the REV-scale block were ranged between the arithmetic mean and harmonic mean of theconductivity estimates from packer tests. The conductivity along north-south direction was 1.4 timesgreater than that along the east-west direction. It was concluded that the anisotropy of conductivitywas insignificant. It was also found that there was a little correlation between $K_b$ and $K_p$. This would be to that the conductivities from the packer test simulation was strongly dependent on thetransmissivity and the number of fractures within the packer test intervals.

  • PDF

A comparative study on characteristics of waterlevel responses to rainfall in the two aquifer systems (강우에 대한 지하수위 반응양상 비교분석 : 강원도 원주지역과 경기도 의왕지역)

  • 이진용;이강근
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.1
    • /
    • pp.3-14
    • /
    • 2002
  • We analyzed hydrologic time-series data obtained from a fractured aquifer in Wonju and a porous shallow aquifer in Uiwang area. Auto-correlation, spectral density, and cross-correlation functions were used for the analyses. Water level at a shallow well in Wonju was weakly auto-correlated and it was sensitive to direct infiltration from rainfall through soil zone while that at a well screened in the fractured zone showed a relative stability to an outer stress (rainfall), which was derived from a delayed transmission of recharge stress through a fracture network from a remote area. Characteristics of time-series data in Uiwang area were similar to those in the fractured zone in Wonju. This was caused by a regional recharge from a distant area rather than a direct infiltration. This study demonstrated a usefulness of time series analyses for identification of recharge mechanism.

A Study on the Groundwater Flow in Fractured-Porous Media by Flow Resistance Theory (단열-다공암반에서 유동저항 이론을 이용한 지하수 유동 평가에 관한 연구)

  • Han Ji-Woong;Hwang Yong-Soo;Kang Chul-Hyung
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.231-238
    • /
    • 2005
  • On the basis of flow resistance theory the conceptual model and related mathematical descriptions is proposed for resistance modeling of groundwater flow in CPM(continuum Porous medium), DFN(discrete fracture network) and fractured-porous medium. The proposed model is developed on the basis of finite volume method assuming steady-state, constant density groundwater flow. The basic approach of the method is to evaluate inter-block flow resistance values for a staggered grid arrangement, i.e. fluxes are stored at cell walls and scalars at cell centers. The balance of forces, i.e. the Darcy law, is utilized for each control volume centered around the point where the velocity component is stored. The transmissivity (or permeability) at the interface is assumed to be the harmonic average of neighboring blocks. Flow resistance theory was utilized to relate the fluxes between the grid blocks with residual pressures. The flow within porous medium is described by three dimensional equations and that within an individual fracture is described by a two dimensional equivalent of the flow equations for a porous medium. Newly proposed models would contribute to develop flow simulation techniques with various matrix characteristics.

  • PDF

A Numerical evaluation of Constant Head Injection Test (수치 모사를 이용한 정압주입시험)

  • Park, Kyung-Woo;Kim, Kyung-Su;Koh, Yong-Kwon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1918-1923
    • /
    • 2009
  • 결정질 암반에서 지하수의 수리적 특성을 파악하기 위해 수행되고 있는 수리시험 방법은 정률법, 정압법, 순간주입(회복)법 등 세 가지로 구분할 수 있다. 본 연구에서 다루는 정압주입시험 (Constant Head Injection Test, CHIT)은 위의 정압법의 한 종류로 토목공학, 지질공학 분야에서 대상 구간의 투수계수 추정을 위해 널리 쓰이는 수리 시험이며, 이는 단일 패커나 이중패커를 이용하여 시험 구간을 격리하고, 격리된 구간에 일정한 압력으로 물을 주입하여 주입되는 물의 양을 파악함으로써, 시험 구간의 수리전도도(Hydraulic conductivity)를 산출하는 전통적인 수리시험이다. 본 연구에서는 수치실험을 통해 시험 구간 및 주입 압력의 크기 등 인위적인 요인에 의해 도출되는 투수계수가 어떻게 달라지는지에 대해 평가해 보았다. 일반적으로 단열 암반에서 수행한 정압주입시험의 해석에 있어 매질을 균질, 등방성 다공질이라는 가정으로 구간별 투수량계수를 산출하기 때문에, 다공성 매질의 지하수 유동을 모사하는 MODFLOW를 수치모사 코드로서 이용하였다. 시험구간의 크기 및 주입압력에 대한 민감도 분석 결과, 시험구간의 크기에 상관없이 수치모의에서 입력한 수리전도도 값에 비해 낮은 수리전도도 값이 산출되었으며, 주입 압력이 클수록 산출되는 수리전도도 값이 매질의 수리전도도 값과 차이가 났다. 민감도 분석 결과 현장수리시험에서 정압 주입시험에 의한 구간별 수리전도도 산출함에 있어 시험구간의 크기와 주입 압력 값에 대하여 고려해야 한다고 판단된다.

  • PDF

Numerical Simulation of Groundwater Flow in Feterogenetic Rockmass of Unsaturated Condition (암반의 불균질성을 고려한 불포화대 지하수 유동 평가)

  • Ha, Jaechul;Lee, Jeong Hwan;Cheong, Jae-yeol;Jung, Haeryong
    • The Journal of Engineering Geology
    • /
    • v.26 no.1
    • /
    • pp.87-99
    • /
    • 2016
  • We present the results of two-dimensional numerical simulations predicting the flow of groundwater in a fractured unsaturated zone. We applied the k-field distribution of permeability derived from discrete fracture network (DFN) modeling as the hydraulic properties of a model domain. To model an unsaturated zone, we set the depth from the ground surface to the underground aquifer. The rate of water infiltration into the unsaturated zone was divided into two parts, an artificial structure surface and unsaturated soil zone. The movement of groundwater through the unsaturated zone was simulated with particular emphasis on contaminant transport. It was clearly observed that the contaminants dissolved in groundwater transported vertically from the ground surface to the saturated zone.

Estimation of the Effective Hydraulic Conductivity in the Granite Area as an Equivalent Continuum Medium (등연속체매질로서의 화강암지역의 유효수리전도도 산출)

  • 김경수;김천수;배대석
    • The Journal of Engineering Geology
    • /
    • v.12 no.3
    • /
    • pp.319-332
    • /
    • 2002
  • This study is focused on the characterization of an effective hydraulic conductivity in each hydrogeologic unit assumed as an equivalent continuum medium in the granitic area. Four boreholes of 3" diameter were installed and a Multi-packer system was facilitated in the selected borehole. Various in-situ tests including the fracture logging, constant injection and fall-off tests, slug and pulse tests were carried out. A hydrogeologic unit was defined into the upper and lower zones based on the variation of fracture properties and hydraulic conductivities. The difference of the result obtained by the various hydraulic tests and the effective characterization techniques on rock mass permeability are also discussed. The effective hydraulic conductivity of the upper unit was measured by two times(5.27E-10 m/s~7.57E-10 m/s) that of the lower unit(2.45E-10 m/s~6.81E-10 m/s)through the constant injection and fall-off tests.