• Title/Summary/Keyword: 투수계수저하

Search Result 62, Processing Time 0.023 seconds

Analysis of an Actual Slope Failure in the Residual Soil by Suction Stress Based Effective Stress (흡수응력에 기반한 유효응력에 의한 실제 잔류토 사면 붕괴의 해석)

  • Oh, Seboong;Lu, Ning;Park, Young Mog;Lee, Junsuk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.3C
    • /
    • pp.113-120
    • /
    • 2012
  • An actual slope failure was analyzed in residual soils at Jinju. Due to rainfall infiltration, the safety factor decreases in the unsaturated layers, since the effective stress and shear strength decrease. In this study, the effective stress is based on suction stress using soil water retention curve. Unsaturated properties were evaluated on soil water retention curve, hydraulic conductivity and shear strength with samples from the site. After infiltration analysis of unsaturated flow under the actual rainfall, the distribution of pore water pressure could be calculated in the slope layers. In the stress field of finite elements, an elastic analysis calculated total stress distribution in the layers and also shear stresses on the slip surface using elastic model. On the slip surface, suction stress and effective stress evaluated the shear strength. As a result, the factor of safety was calculated due to rainfall, which could simulate the actual slope failure. In particular, it was found that the suction stress increases and both the effective stress and the shear strength decrease simultaneously on the slip surface.

A Study on the Engineering Properties of Micro Fine Hybrid Silicate Grout Materials (마이크로 복합실리카 그라우트재의 공학적 특성에 관한 연구)

  • Chun, Byung-Sik;Kim, Jin-Chun;Choi, Young-Chul;Jung, Jong-Ju;Yoon, Nam-Sik;Shin, Sang-Jae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.2 no.1
    • /
    • pp.67-79
    • /
    • 2001
  • The objective of this study is to determine the engineering properties of micro fine hybrid silicate grout materials that were developed recently. In this study, MSG-N type was mainly used as grout materials, and the chemical components, grain size distribution, mineral characteristics were analyzed. Moreover, the properties of active silica and ordinary portland cement acting as coagulating agent were analyzed and compared with each other. To determine the engineering properties, the bleeding test, viscosity test, coagulation test, examination with naked eye, photographing by using SEM, uniaxial compression test and in-situ application test for reclaimed ground were carried out. A series of test results showed that the strength of micro fine hybrid silicate grout materials was about twice that of ordinary sodium silicate grout materials, and alkali leakage decreased dramatically when MSG method was utilized. Especially, based on the evaluation of the application of the MSG method to field, this method would be very effective in reducing coefficient of permeability due to its excelent permeability.

  • PDF

Influence of Mechanical Properties and Pore Structure on the Scaling Resistance of Concretes (콘크리트의 역학적 성능 및 공극구조가 스케일링 저항성에 미치는 영향)

  • Lee, Seung-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.111-118
    • /
    • 2016
  • The scaling of concrete caused by the combined effects of frost and deicing salt is one of the principle causes of damage to transportation infrastructure in cold-climate regions. In this study, to evaluate the factors affecting scaling resistance of concrete, the relationship between the properties of concrete, such as the mechanical properties and pore structure, and scaling resistance was examined experimentally. The test results showed that the scaling resistance was strongly dependent on the absorption properties of concrete, but not on the compressive strength. Furthermore, it is believed that both the spacing factor and specific surface of the air voids was not a good parameter for evaluating the scaling resistance of concrete. SGC concrete was less durable than OPC and SFC concrete with respect to the scaling resistance in the scope of the present study.

Mineralogical and Physico-chemical Properties of Sludge Produced During Artificial Sand Processing (국내 화강암류를 이용한 일부 인공쇄석사 제조과정에서 발생되는 슬러지의 광물.물리화학적 특성)

  • Yoo, Jang-Han;Kim, Yong-Ug
    • Journal of the Mineralogical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.303-311
    • /
    • 2007
  • The consumption of artificially crushed sands exceeds more than 30 percent of the domestic sand supply in South Korea, and its rate is still increasing. For the manufacture of crushed sand granites and granitic gneisses are preferred, fine fractions (i.e. sludge, particles finer than 63 microns) are removed by use of flocculation agents, and its amount occupy about 15 wt%. The sludges consist of quartz, feldspars, micas, chlorite/vermiculite, kaolinites, smectites and occasionally calcite. Among the clay minerals micas are usually predominant, and $14{\AA}$ minerals, kaolinites and smectites are rather scarce. Jurassic granites usually contain more kaolinites and smectites than those of Cretaceous to Tertiary granites, probably due to longer geologic ages. On the other hand, sludge from Precambrian gneiss does not contain kaolinites and smectites. Chemical analyses for the granites and their sludges show rather clear differences in most of major chemical components. Except for $SiO_2,\;Na_2O\;and\;K_2O$, all other components represent rather clear increase. Decrease of $SiO_2$ content is attributed to the relative decrease of quartz in the sludges. And the $Na_2O decrease is caused by a relatively stronger weathering property of albite compared to Ca plagioclase. The $K_2O$ content shows rather small differences throughout the whole samples. The increases of $Al_2O_3$ and other major components resulted from weathering processes and most of colored components are also concentrated in the sludges. Particle size analyses reveal that the sludges are categorized as sandy loams in a sand-silt-clay triangular diagram. The sludge is now classified as industrial waste because of its impermeability, and this result was also confirmed by rather higher hydraulic conductivities. For the environmental problems, and accomplishing effective sand manufacture, more fresh rocks with little weathering products must be chosen.

Characterization of Area Installing Combined Geothermal Systems : Hydrogeological Properties of Aquifer (복합지열시스템에 대한 부지특성화: 대수층의 수리지질학적 특성)

  • Mok, Jong-Koo;Park, Yu-Chul;Park, Youngyun;Kim, Seung-Kyum;Oh, Jeong-Seok;Seonwoo, Eun-Mi
    • The Journal of Engineering Geology
    • /
    • v.27 no.3
    • /
    • pp.293-304
    • /
    • 2017
  • This study was performed in order to hydrogeological analysis of aquifer, which is a necessary part for evaluating the efficiency of the combined well and open-closed loops geothermal (CWG) systems. CWG systems have been proposed for the effective utilization of geothermal energy by combining open loop geothermal systems and closed loop geothermal systems. Small aperture CWG systems and large aperture CWG systems were installed at a green house land with water curtain facilities in Chungju City. Aquifer tests include pumping tests and step-drawdown tests were conducted to analyse hydrogeological characteristics of aquifer in the study area. The transmissivity was estimated in the range of $13.49{\sim}58.99cm^2/sec$, and the storativity was estimated in the range of $1.13{\times}10^{-5}{\sim}5.20{\times}10^{-3}$. The geochemical analysis showed $Ca^{2+}$ ion and ${HCO_3}^-$ ion were dominant in groundwater. The Langelier Saturation Index and the Ryznar Stability Index showed low scaling potential of groundwater. In the analysis of vertical water temperature change, the geothermal gradient was estimated as $2.1^{\circ}C/100m$, which indicated the aquifer was enough for geothermal systems. In conclusion, groundwater is rich, can stably use geothermal heat, and it is less likely to cause deterioration of thermal energy efficiency by precipitation of carbonate minerals in study area. Therefore, the study area is suitable for installation of the combined geothermal system.

A Study on the Durability Improvement by Controlling the Deterioration of Underground Concrete Structures (지하 콘크리트구조물의 열화 억제에 의한 내구성 증진에 관한 연구)

  • 천병식;최춘식;정원우
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.3
    • /
    • pp.23-31
    • /
    • 2004
  • Normally, coating is used for protecting reinforced concrete. For this purpose, both organic and inorganic coatings are used. The advantages of inorganic coatings are lower absorption of UV, non-burning etc. On the other hand, organic coatings have the advantage of low permeability of $CO_2, SO_2$ and water. Organic coatings provide better protection for reinforced concrete. However, organic coatings such as epoxy, urethane and acryl reduce long-term adhesive strength by the difference of their thermal expansion coefficients and elastic modules from those of concrete, and the formed coating cover of these is blistered by poor breathing. Also, when organic coatings are applied to the wet surface of concrete, they have a problem with adhesion. In this study, a new coating material for protecting concrete was hybridized with polymer and ceramics. And tests were carried out on its physical and durable characteristics, and safety characteristic on elution. All results were compared with organic coating materials and epoxies and showed that the performance of the developed coating material was not inferior to that of other organic coatings in protecting concrete. On the other hand, safety characteristic on elution was superior to epoxies which were used in this study. So, the developed coating material was considered as a suitable protecting coating material which have advantages of inorganic and organic coatings for protecting underground concrete structures, especially in contact with water.

Study on Permeability, Optimum Yield and Long-term Stability in Alluvial Well with Filter Layer Change (충적우물에서 필터층 변화에 따른 투수특성, 적정양수량 및 장기적 안정성에 대한 연구)

  • Song, Jae-Yong;Lee, Sang-Moo;Choi, Yong-Soo;Kim, Ki-Joon;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.28 no.1
    • /
    • pp.101-115
    • /
    • 2018
  • This study was carried out to evaluate the effects of various filter conditions on unconfined aquifer (alluvial aquifer). We made model test device which has filter layer, pumping well and observation well which consist of sand layer and gravel layer to test. Step drawdown test and long term pumping tests were carried out using the device. The permeability characteristics of each test group were confirmed and the optimal yield was calculated. As a result of comparing the optimal yield of double filter and single filter in sand, dual-filter SD-300 was valued at 216.8 % higher final optimal yield than single-filter SS-300. Comparing the dual filter SD-300 and the single filter SS-100 with a thin filter layer, dual-filter SD-300 was valued at 709.2% higher final optimal yield than single-filter SS-300. As a result of analysis of optimal yield change over time, It was confirmed that the ratio of optimal yield of single filter and dual filter increase over time. In order to evaluate the long-term change in water intake efficiency, we considered the point at which the initial optimal yield was reduced by 50%. The dual filter SD-300 is about 351.1% higher than SS-300, which is the same thickness filter, and about 579.0% higher than SS-100. From these results, Assuming that the point at which the initial quantity of water intake is reduced to 50% is the well life, double filters are expected to increase their lifespan by about 3.5 times over single filters of the same thickness and by about 5.8 times over typical single filter. These results can be used to design wells to river bank filtration or filtered seawater. In addition, it is possible to clarify the effect of the double filter through the comparison with the future field test results.

An Experimental Study on Filtration Efficiency of Sand Filter Layers to TSS and COD in Non-point Source Pollutant (분산형 빗물 저류조용 모래 여과층을 적용한 도심지 비점오염원의 TSS와 COD 정화효율에 대한 실험적 연구)

  • Ahn, Jaeyoon;Lee, Dongseop;Han, Shinin;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1477-1488
    • /
    • 2014
  • Prevalent construction of impermeable pavements in urban areas causes diverse water-related environmental issues, such as lowering ground water levels and shortage of water supply for the living. In order to resolve such problems, a rainwater reservoir can be an effective and useful solution. The rainwater reservoir facilitates the hydrologic cycle in urban areas by temporarily retaining precipitation-runoff within a shallow subsurface layer for later use in a dry season. However, in order to use the stored water of precipitation-runoff, non-point source pollutants mostly retained in initial rainfall should be removed before being stored in the reservoir. Therefore, the purification system to filter out the non-point source pollutants is essential for the rainwater reservoir. The conventional soil filtration technology is well known to be able to capture non-point source pollutants in a economical and efficient way. This study adopted a sand filter layer (SFL) as a non-point source pollutant removal system in the rainwater reservoir, and conducted a series of lab-scale chamber tests and field tests to evaluate the pollutant removal efficiency and applicability of SFL. During the laboratory chamber experiments, three types of SFL with the different grain size characteristics were compared in the chamber with a dimension of $20cm{\times}30cm{\times}60cm$. To evaluate performance of the reservoir systems, the concentration of the polluted water in terms of TSS (Total Suspended Solids) and COD (Chemical Oxygen Demand) were measured and compared. In addition, a reduction in hydraulic conductivity of SFL due to pollutant clogging was indirectly estimated. The optimum SFL selected through the laboratory chamber experiments was verified on the in-situ rainwater reservoir for field applicability.

Study on the Characteristics of Shear Strength on the Weathered Granite Soil Slope in Accordance with the Rainfall (강우에 따른 화강암질 풍화토 사면의 전단강도 특성에 관한 연구)

  • Shim Tae-Sup;Kim Sun-Hak;Ki Wan-Seo;Joo Seung-Wan
    • The Journal of Engineering Geology
    • /
    • v.14 no.4 s.41
    • /
    • pp.349-360
    • /
    • 2004
  • This study calculated the pore water pressure, the depth of seepage, the constant of the strength in accordance with the slope inclination and the rainfall intensity over the slope built by the weathered granite soil (SP, SM). And, the change of the shear strength in accordance with the rainfall has been compared and analyzed by applying the shear strength formula of the unsaturated soil. As a result, the rainfall intensity is stronger and the slope inclination is gentler the seepage speed in accordance with the rainfall became faster proportionally. As a result of comparing and analyzing both the theoretical value of Lumb and the actual value of the model, it can be said that the actual value is faster. Since SM shows the bigger shear strength than SP, it can also be said that as the granules increase, the coefficient of permeability becomes smaller; and as the seepage rate became smaller, it affects the seepage speed. Likewise, the shear strength within the slope displays the smallest shear strength at the inclination of 1:1.5 the reason of its decrease turned out that it was due to the increase of the pore water pressure.

An Introduction to the DECOVALEX-2019 Task G: EDZ Evolution - Reliability, Feasibility, and Significance of Measurements of Conductivity and Transmissivity of the Rock Mass (DECOVALEX-2019 Task G 소개: EDZ Evolution - 굴착손상영역 평가를 위한 수리전도도 및 투수량계수 측정의 신뢰도, 적합성 및 중요성)

  • Kwon, Saeha;Min, Ki-Bok
    • Tunnel and Underground Space
    • /
    • v.30 no.4
    • /
    • pp.306-319
    • /
    • 2020
  • Characterizations of Excavation Damage Zone (EDZ), which is hydro-mechanical degrading the host rock, are the important issues on the geological repository for the spent nuclear fuel. In the DECOVALEX 2019 project, Task G aimed to model the fractured rock numerically, describe the hydro-mechanical behavior of EDZ, and predict the change of the hydraulic factor during the lifetime of the geological repository. Task G prepared two-dimensional fractured rock model to compare the characteristics of each simulation tools in Work Package 1, validated the extended three-dimensional model using the TAS04 in-situ interference tests from Äspö Hard Rock Laboratory in Work Package 2, and applied the thermal and glacial loads to monitor the long-term hydro-mechanical response on the fractured rock in Work Package 3. Each modelling team adopted both Finite Element Method (FEM) and Discrete Element Method (DEM) to simulate the hydro-mechanical behavior of the fracture rock, and added the various approaches to describe the EDZ and fracture geometry which are appropriate to each simulation method. Therefore, this research can introduce a variety of numerical approaches and considerations to model the geological repository for the spent nuclear fuel in the crystalline fractured rock.