• Title/Summary/Keyword: 토탈스테이션

Search Result 60, Processing Time 0.028 seconds

Electric Power Line Dips Measurement Using Drone-based Photogrammetric Techniques (드론 기반 사진측량기법을 활용한 고압 송전선의 처짐량 측정)

  • Kim, Yu Jong;Oh, Jae Hong;Lee, Chang No
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.35 no.6
    • /
    • pp.453-460
    • /
    • 2017
  • High voltage power transmission lines have been to keep the proper dip for maintenance. Powerline dips at a random point are conventionally measured by the direct or indirect observation but it is not only unsafe but labor-intensive. Therefore in this study we applied the photogrammetric technique to remotely measure the powerline dips. Since it is not easy to extract conjugate points from linear powerlines, we exploited the epipolar lines acrossing the powerlines for 3D mapping of the powerlines and dip measurements. The vertical mapping accuracy estimated at two field-surveyed power line points was 15~16cm that are within 5% of deflection at the points and less than 3% of the powerline dip.

An experimental study on discharge measurements according to the change of traverse direction sideline angle (횡단방향 측선각도 변화에 따른 유량측정성과에 대한 실험 연구)

  • Lee, Jae-Hyug;Seok, Su-Won;Shim, Eun-Jeung;Kim, Sung-Hoon;Kim, Tae-Woong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.330-334
    • /
    • 2011
  • 자연하천의 유량값은 일반적으로 횡단면의 면적과 이를 통과하는 유속의 곱으로 산정된다. 유량측정 방법은 하천의 형태와 저 평수기 및 홍수기의 수위에 따라 도섭법, 교량법, 부자법 및 보트를 이용한 ADVM 측정법 등 다양한 방법으로 실시된다. 그러나 현장 여건에 따라 흐름에 직각이 아닌 사교에서 측정이 이루어지는 경우에는 단면적의 오차를 포함할 가능성이 크기 때문에 횡단면의 측선 각도에 따라 각보정을 실시해야 한다. 현재 사교에서 유량 측정을 실시하는 경우, 흐름의 직각을 기준으로 처짐각을 측량하여 각 측선에 $cos{\theta}$를 적용하여 단면적을 보정하고 있는데, 이 처짐의 정도가 유량의 참값에서 어느 정도의 영향을 미치는지에 대한 검토가 요구된다. 본 연구에서는 한강수계 왕숙천에 위치한 퇴계원 지점에서 실시간 수위에 따른 유속을 측정하였으며, 횡단면에 직각인 측선을 기준값으로 제시하고, 처짐각의 정도를 $10^{\circ}$, $20^{\circ}$, $30^{\circ}$, $40^{\circ}$, $50^{\circ}$까지 늘려 산정된 유량값을 기준값과 비교 분석하였다. 본 연구에 쓰인 측정기기는 Price AA 유속계이고, 측정방법으로는 유량의 흐름 방향을 기준하여 직각으로 수면에서 0.6d 지점의 유량측정방법(1점법)을 적용하였다. 그 결과 유량의 흐름 방향을 기준하여 직각인 경우 $1.39m^3/s$의 유량에서 보정 전 각 $10^{\circ}$의 유량 $1.36m^3/s$, $30^{\circ}$의 유량 $1.49m^3/s$, $50^{\circ}$의 유량 $2.25m^3/s$로 각이 클수록 단면적이 크게 나타나며 유량 역시도 과대 산정됨을 알 수 있었다. 따라서 도섭법을 이용한 유량측정이나 사교에서의 교량법 등을 적용하여 유량측정을 실시할 경우 유량의 흐름방향을 기준으로 직각으로 유량측정을 실시하여 유량을 산정하되 부득이한 경우로 사교에서의 측정이 이루어 졌을 시 흐름 방향을 기준으로 각도를 측정하여 크게 나타나는 단면적에 처짐각을 보정하여 유량을 산정함이 오차를 줄일 수 있으며, 신뢰성 있는 유량자료 생산의 방법이 라 할 수 있겠다.

  • PDF

Monitoring of Long-Term Behavior of The Continuous IPC Girder Bridge (IPC거더 연속교의 장기거동 모니터링)

  • Lee, Hong-Woo;Ahn, Jeong-Seang;Kim, Kyoung-Won;Yu, Sang-Hui
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.349-352
    • /
    • 2008
  • IPC girder is more prestressed and has smaller sectional area than the conventional PSC-I type girder due to incremental prestressing along the construction process. The continuous IPC girder bridge may have problems in serviceability and stresses at internal supports because it is very flexible. In this paper, The long-term behavior of the continuous IPC girder bridge is studied through long-term structural analysis and monitoring the deflections. The long-term behavior is monitored right before the introduction of 2nd prestressing that is the construction process different from the conventional PSC-I type girder bridge. The total station of high-precision was used in measuring the deflections. According to the monitoring result so far, the continuous IPC girder bridges does not show remarkable long-term behavior like severe camber or deflection and the measured deflections are very similar to the results of long-term structural analysis.

  • PDF

Levee Maintenance Using Point Cloud Data Obtained from a Mobile Mapping System (모바일 매핑시스템을 이용한 제방 유지보수에 관한 연구)

  • Lee, Jisang;Hong, Seunghwan;Park, Il suk;Mohammad, Gholami Farkoushi;Kim, Chulhwan;Sohn, Hong-Gyoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.4
    • /
    • pp.469-475
    • /
    • 2021
  • In order to effectively maintain and manage river facilities, on going data collection of associated objects is important. However, the existing data acquisition methods of using a total station, a global navigation satellite system, or a terrestrial laser scanner have limitations in terms of cost/time/manpower when acquiring spatial information data on river facilities distributed over a wide and long area, unlike general facilities. In contrast, a mobile mapping system (MMS), which acquires data while moving its platform, acquires precise spatial information data for a large area in a short time, so it is suitable for use in the maintenance of linear facilities around rivers. As a result of applying a MMS to a research area of 4 km, 184,646,099 points were acquired during a 20-minute data acquisition period, and 378 cross-sections were extracted. By comparing this with computer-drawn river plans, it was confirmed that efficient levee management using a MMS is possible.

A Study on Applicability Evaluation of digital Photogrammetry for Settlement Measurement of Soil Contaminated with Heavy Metals (중금속으로 오염된 지반의 침하계측을 위한 수치사진측량의 적용성 평가)

  • Han, Jung-Geun;Park, Jeong-Jun;You, Seung-Kyong;Yun, Jung-Mann;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.4
    • /
    • pp.85-93
    • /
    • 2020
  • This study describes the results of laboratory model test on settlement of soil contaminated with heavy metals, in order to evaluate the applicability of VMS to the measurement of gound settlements generated during the purification of contaminated soil. The measurement results for settlement of contaminated soil were compared using a 3D-Visual Monitoring System (VMS) based on digital photogrammetry and a total station. The test result showed that the settlement of the soil contaminated with heavy metals occurred a lot in the experimental condition in which the hydrophilic filter was applied. The minimum and maximum error ranges of VMS were calculated as ±0.36mm and ±0.87mm, respectively, and the error of VMS was satisfied in all experimental conditions. The average error rate of VMS was lower in the hydrophilic filter condition than in the hydrophobic filter condition. Therefore, it was evaluated that VMS can be applied to measure the settlement of contaminated soil.

Development of Automatic Displacement Measuring System Using 3D Digital Photogrammetry Image and Its Application (수치사진영상을 이용한 자동 변위계측시스템의 개발과 적용)

  • Han, Jung-Geun;Kim, Young-Seok;Cho, Sam-Duk;Kwak, Ki-Seok;Hong, Ki-Kwon
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.5
    • /
    • pp.53-62
    • /
    • 2007
  • Recently, for the stabilization estimation of structures, many automatic measuring instruments with expensiveness and high accuracy have been developed and utilized. However, the existing manual measuring systems are almost impossible to measure the real-time for the whole surface of large-scale structures and an automatic measuring system has disadvantages with demanding enormous expense. In this study, 3D digital visual monitoring system was developed by using digital photogrammetry technique. To confirm application of developed system, it was applied to the measurement of the wall displacement of concrete surface and displacement measurement of reinforced-soil wall block. Then, the result of the test was compared with measuring value of total station. Based on the results of the comparison, the application of visual monitoring system was evaluated. The results show that the developed visual monitoring system could be available in displacement measure of structures.

Analysis of 3D Accuracy According to Determination of Calibration Initial Value in Close-Range Digital Photogrammetry Using VLBI Antenna and Mobile Phone Camera (VLBI 안테나와 모바일폰 카메라를 활용한 근접수치사진측량의 캘리브레이션 초기값 결정에 따른 3차원 정확도 분석)

  • Kim, Hyuk Gi;Yun, Hong Sik;Cho, Jae Myoung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.33 no.1
    • /
    • pp.31-43
    • /
    • 2015
  • This study had been aimed to conduct the camera calibration on VLBI antenna in the Space Geodetic Observation Center of Sejong City with a low-cost digital camera, which embedded in a mobile phone to determine the three-dimension position coordinates of the VLBI antenna, based on stereo images. The initial values for the camera calibration have been obtained by utilizing the Direct Linear Transformation algorithm and the commercial digital photogrammetry system, PhotoModeler $Scanner^{(R)}$ ver. 6.0, respectively. The accuracy of camera calibration results was compared with that the camera calibration results, acquired by a bundle adjustment with nonlinear collinearity condition equation. Although two methods showed significant differences in the initial value, the final calibration demonstrated the consistent results whichever methods had been performed for obtaining the initial value. Furthermore, those three-dimensional coordinates of feature points of the VLBI antenna were respectively calculated using the camera calibration by the two methods to be compared with the reference coordinates obtained from a total station. In fact, both methods have resulted out a same standard deviation of $X=0.004{\pm}0.010m$, $Y=0.001{\pm}0.015m$, $Z=0.009{\pm}0.017m$, that of showing a high degree of accuracy in centimeters. From the result, we can conclude that a mobile phone camera opens up the way for a variety of image processing studies, such as 3D reconstruction from images captured.

Deformation Measurements of Dam using Terrestrial Laser Scanner (지상레이저스캐너를 이용한 댐의 변위관측)

  • Park, Sae-Hoon;Choi, Duk-Hwa;Han, Dong-Yeob
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.1
    • /
    • pp.645-655
    • /
    • 2009
  • Deformations of the dam have been monitored by control points buried in the upper and lower dam of Samrangjin pumped storage power plant. The horizontal and vertical deformation observations performed in 1997, 2002, 2007 are to identity movements of the dam body by comparing and analyzing control points. For that reason, it was difficult to analyze movements of the dam in detail. Therefore, this research has observed surface of the dam using terrestrial laser scanner and estimate movements of the dam by comparing and analyzing scanned and designed surfaces of the dam since building completion. Vertical deformation of upper dam took place in the middle of ridge of dam, maximum cross section, up to 1.5m. In the middle and middle bottom of the downstream slope, vertical deformation was produced 0.75m around SP4-2 point and 0.5m around SP4-4 point. The maximum subsidence of vertical deformation in the lower dam took place in the middle of ridge of dam and upper part of upstream slope and subsidence was analyzed from -0.4 to -1.0m respectively. The result of this research can be used as initial observation to analyze whole movement of the dam in the future.

The Construction of 3D Spatial Imagery Information of Dam reservoir using LiDAR and Multi Beam Echo Sounder (LiDAR와 MBES를 이용한 댐 저수지 3차원 공간영상정보 구축)

  • Lee, Geun-Sang;Choi, Yun-Woong
    • Spatial Information Research
    • /
    • v.18 no.3
    • /
    • pp.1-11
    • /
    • 2010
  • Recently, the construction of three dimensional spatial information of Dam reservoir area is very important part in Dam management work such as sediment survey, but it is difficult to acquire detailed terrain data because totalstation and single beam echo sounder are applied to terrain survey. This study presented method to construct detailed terrain data of Dam reservoir area using LiDAR and multi beam echo sounder. First, LiDAR survey was carried out in land zone and calibration process was applied by ground control point. And also the DEM of land zone was constructed by using algorithm, which eliminated building and vegetation class. As the result of validation of LiDAR DEM using GPS terrain survey, it was possible to construct three dimensional terrain data that was satisfied with the tolerance error of LiDAR, which was the standard error of LiDAR DEM showed as 0.108m. Also multi beam echo sounder was applied to the survey of water zone and it could construct spatial information that was satisfied with bathymetry surveying tolerance error of International Hydrographic Organization by validation with terrain survey data. And LiDAR and multi beam echo sounder data were integrated and it was possible to construct three dimensional spatial imagery information that can be applied to Dam management work such as the estimation of sediment amounts or the monitoring of terrain change by linking with high resolution orthophoto.

Application of Smartphone Camera Calibration for Close-Range Digital Photogrammetry (근접수치사진측량을 위한 스마트폰 카메라 검보정)

  • Yun, MyungHyun;Yu, Yeon;Choi, Chuluong;Park, Jinwoo
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.1
    • /
    • pp.149-160
    • /
    • 2014
  • Recently studies on application development and utilization using sensors and devices embedded in smartphones have flourished at home and abroad. This study aimed to analyze the accuracy of the images of smartphone to determine three-dimension position of close objects prior to the development of photogrammetric system applying smartphone and evaluate the feasibility to use. First of all, camera calibration was conducted on autofocus and infinite focus. Regarding camera calibration distortion model with balance system and unbalance system was used for the decision of lens distortion coefficient, the results of calibration on 16 types of projects showed that all cases were in RMS error by less than 1 mm from bundle adjustment. Also in terms of autofocus and infinite focus on S and S2 model, the pattern of distorted curve was almost the same, so it could be judged that change in distortion pattern according to focus mode is very little. The result comparison according to autofocus and infinite focus and the result comparison according to a software used for multi-image processing showed that all cases were in standard deviation less than ${\pm}3$ mm. It is judged that there is little result difference between focus mode and determination of three-dimension position by distortion model. Lastly the checkpoint performance by total station was fixed as most probable value and the checkpoint performance determined by each project was fixed as observed value to calculate statistics on residual of individual methods. The result showed that all projects had relatively large errors in the direction of Y, the direction of object distance compared to the direction of X and Z. Like above, in terms of accuracy for determination of three-dimension position for a close object, the feasibility to use smartphone camera would be enough.