• Title/Summary/Keyword: 탐사율

Search Result 331, Processing Time 0.029 seconds

Improving the Detection of the Water Mains Underground Facilities (상수도 지하시설물 탐사 개선에 관한 연구)

  • Kim, Jae-Myeong;Lee, Byung-Woon;Choi, Yun-Soo;Yoon, Ha-Su
    • Spatial Information Research
    • /
    • v.18 no.4
    • /
    • pp.23-32
    • /
    • 2010
  • Water mains underground facilities are essential components to make up urban infrastructure. In order to manage these water mains underground facilities systematically and scientifically, GIS (Geographic Information System) had been constructed. For the sake of construction of GIS for water mains underground facilities, an exact underground detection and the construction of DB (Data Base) for buried water mains underground facilities should be preceded. In this study, in order to find out the ways to improve exact detection rate of data, the statistical analysis for the causes of detection raw degradation was done, and standardization methods of detection through a case study were suggested, When water mains underground facilities were measured, the detection of non-metallic water pipes was not carried out. The reason was that the results of detection was uncertain and detection was difficult because the assessment of public measurements was vulnerable. Moreover, due to the absence of standardized operating regulations for detection, systematic surveys weren't conducted. In this study, methods to standardize works over the detection of water mains underground facilities were presented so that we can improve the detection rate when we are doing that. As the proposals to improve detection rate, effective performance assessment over non-metallic pipes were presented, and related issues to supplement work regulations of public survey were described systematically.

A study on Improving the Accuracy Detection of the Water Mains Underground Facilities (상수도 지하시설물 탐사정확도 제고방안 -서울시 상수도 GIS사례를 중심으로-)

  • Lee, Byung-Woon;Choi, Yun-Soo;Cha, Seong-Yeol;Yoon, Ha-Su;Song, Hyun-Kun
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2010.09a
    • /
    • pp.344-345
    • /
    • 2010
  • 도시 인프라를 구성하는 필수적 요소인 상수도 시설물을 체계적이고 과학적으로 관리하고자 상수도 GIS를 구축하였으나 그 동안 구축된 상수도 지하시설물에 대한 위치정확도가 높지 않아 정확도 개선사업이 필요하게 되었다. 이에, 본 연구에서는 통계적인 자료를 통하여 탐사율 저하원인을 분석하고 서울시 상수도 GIS의 사례를 조사함으로써 탐사에 대한 표준화 방안과 함께 탐사율 제고를 위한 정책 제안사항을 제시하였다. 이로써, 체계적인 탐사를 통하여 탐사율을 향상시킬 수 있을 것으로 판단된다.

  • PDF

A Vertical Gravity Gradient Survey for Shallow Density Mapping (수직 중력 변화율 탐사 적용 사례)

  • Park, Yeong-Sue;Rim, Hyoung-Rae;Lim, Mu-Taek;Koo, Sung-Bon;Lee, Young-Chal
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.161-166
    • /
    • 2006
  • Vertical gravity gradient measurement offers greater structural resolution and detectability than gravity alone. Practical difficulties of field measurement of vertical gravity gradient have raised questions of its accuracy and utility. But, modern automated gravimeter of $1\;{\mu}Gal$ sensitivity makes it easier to measure vertical gradient with required accuracy. It is particularly effective to engineering and environmental problems which target shallow subsurface structure. This paper attempts to apply the vertical gravity gradient technique to high resolution density mapping. The method was generally reviewed and numerical inverse modeling was executed for comparing with conventional gravity. And actual vertical gravity gradient data surveyed overt karstic cavity area at Muan was analysed and interpreted.

  • PDF

Land-cover features analysis using reflectance of satellite images (인공위성영상자료의 분광반사율 특성을 이용한 고창지역의 토지피복현황분석)

  • Lee Sung-Soon;Chi Kwnag-Hoon
    • Proceedings of the KSRS Conference
    • /
    • 2006.03a
    • /
    • pp.283-286
    • /
    • 2006
  • 인공위성 영상자료를 이용하는 원격탐사는 지질, 환경, 지형도제작 등 다양한 분야에서 연구되고 있다. 특히 다중 및 초분광영상자료는 태양을 에너지원으로 하여 지표면 전자기파의 반응을 영상화하는 다중 및 초분광영상자료의 활용을 위해 분광반사율정보가 더욱 활발하게 이용될 것으로 기대된다. 본 연구에서는 고창지역에 대해 주기적으로 실시하고 있는 분광반사율 및 USGS 분광라이브러리 성과를 이용하여 다중파장대 위성영상자료인 ASTER와 분광반사율을 이용한 위성영상의 활용가능성 및 검보정의 가능성을 제시 하고자 한다.

  • PDF

Detection of the Pipe Leak for Water Distribution System Using Ground Penetrating Radar (GPR을 이용한 상수관로의 누수 탐사)

  • Park, In-Chan;Cho, Won-Cheol
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1271-1274
    • /
    • 2006
  • 지하레이다(Ground Penetrating Radar, GPR)를 이용하여 지표하의 상수관로를 지표에서 송신안테나와 수신안테나를 이용해서 손쉽게 측정하게 된다. 송신안테나는 지표하에 전자기파를 송신하고 지하 매질을 투과한 파가 수신안테나에 도달하는 시간을 측정하여 지표하 매질의 특성을 파악할 수 있다. 수신파의 도달시간은 지표하 매질의 특성에 따라서 변화하며, 이를 통해 지표하 매질과 매질 깊이 등을 파악할 수 있다. 일반적으로 상수관로를 매설할 경우 관로 주변의 토양은 균등하게 되므로 기 매설된 상수관로 주변에 누수가 발생하게 되면, 관로 주변의 토양은 포화상태이거나 수압으로 인해서 공동이 형성될 경우가 많다. 이때 반사에너지의 유전율 증가 혹은 감소 특성으로 인해서 주변 매질과는 매우 상이한 결과를 보이게 된다. GPR탐사는 단순히 반사된 신호진폭의 크기를 나타내며 이러한 반사에너지의 크기에 관계되는 것은 매설물의 유전율이 주위 지반이 갖는 유전율과의 차이에서 기인하기 때문이다. 탐사 대상 상수관로에 대한 정보를 확보하여 GPR 탐사를 수행한 결과 관로 탐사를 위한 GPR의 결과는 매우 유용하게 사용될 것으로 판단되며, 이를 바탕으로 누수 발생 이력이 있는 다양한 관로주변 조건을 대상으로 탐사를 실시할 경우 상수관망시스템의 효율적인 관리 및 보수에 매우 유용한 방법이 될 수 있을 것으로 판단된다.

  • PDF

A Study on Applicability of Water Pipe Detecting Using GPR (상수관로 탐사에 대한 지중레이더의 적용가능성에 관한 연구)

  • Lee, Won-Jong;Lim, Sung-Min;Choi, Yun-Soo;Min, Kwan-Sik
    • Journal of Cadastre & Land InformatiX
    • /
    • v.45 no.2
    • /
    • pp.131-147
    • /
    • 2015
  • In modern society, as to the underground urban infrastructure facilities(communication electricity water and sewage gas etc.) were contained many risks because of excavating. The exact position of underground facilities and the attribute information should be built in order to prevent accidents. As the result of analyzing the public surveying results from 2004 to 2009, it shows that low detecting rate of water pipeline which is only 52.4%, because the exploration of electromagnetic induction only detect metal pipeline and positioning survey only detect new pipeline before burying. Therefore development and verification of the correct and efficient exploration techniques are needed to improve the detecting rate. In this study, determined based on the location measurement results for the non-metal pipes and metal pipes before burial. It was compared with values that obtained through the ground penetrating radar and electromagnetic induction detecting. As a result, detecting rate of the concrete section showed a 100%, unpaved section showed a 94.7%, asphalt section showed 60%. So it confirmed the applicability of the ground penetrating radar at underground facilities detecting.

살내유적지 발굴조사 : 2. 지구물리학적 고찰

  • 김성욱;김인수;이현재;최은경;이성주
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.134-139
    • /
    • 2002
  • 살내 유적지의 발굴조사에서 지질물리학에 기초한 연구방법과 적용성을 검토하고자 발굴과 아울러 지구물리탐사를 실시하였다. 심도에 따라 구분한 전기비저항에서 토양 구성물질의 차이에 의한 전기비저항의 변화와 퇴적물의 공급방향을 유추할 수 있다. 지하레이더탐사의 반사단면에서 퇴적층의 분급과 입도에 따라 구분되는 층리의 경계를 규명할 수 있는데, 실트의 구성비가 높은 지층들의 반사면은 측방 연장성이 좋은 반면 자갈의 구성비가 높은 지층의 반사면들은 불규칙한 기복을 보여준다. 지층 반사면의 형태로부터 고환경의 정보를 획득할 수 있는데, 살래유적지의 경우 문화층은 세립의 실트와 모래와 우세한 지층에 해당하며 층서에서 자갈층의 반복과 지층 경사는 퇴적물의 공급에 관련되는 고수계의 위치와 하천의 지속적으로 범람하는 환경을 지시한다. 주거 유적지의 대자율탐사에서 유적지 경계부의 토양은 주변에 비해 낮은 대자율을 가진다. 대자율 이상대를 형성하는 토양은 주거지 내부에 한정되며 이들은 황색계열의 토색으로 소성에 의한 것으로 추정된다.

  • PDF

충적층하부 대규모 파쇄대의 파악을 위한 물리탐사

  • 황학수;문창규;박윤성;염병우
    • Proceedings of the KSEG Conference
    • /
    • 2002.04a
    • /
    • pp.285-290
    • /
    • 2002
  • 조사지역은 전라남도 함평군 함평읍으로부터 남쪽으로 엄다면 화양리, 학야리, 성천리 일대에 발달한 충적층으로서. 이 지역에는 남서-북동방향으로 광주단층이 통과하고 있는 것으로 추정된다. 충적층 하부에 발달한 단층을 포함한 대규모 파쇄대 파악에는 지표지질조사로서 한계가 있다. 따라서 이 연구에서는 물리탐사방법을 적용하여 충적층 하부의 대규모 파쇄대의 방향과 연장성을 파악하고자 하였으며, 사용된 물리탐사법은 전기비저항 2차원탐사, 전자탐사 그리고 자력탐사이다. 전기비저항 탐사결과 충적층 내에서 남북방향의 연장성을 갖는 전기비저항 이상대가 파악되었으나, 자력탐사와 전자탐사의 측정자료에는 이 이상대에대한 반응을 관찰할 수 없었다. 이는 전자탐사의 경우, 가탐심도가 매우 작은 EM31을 사용하였고, 또한 자력탐사는 주변 지질매체 간의 대자율 차이가 없는 것에 기인한 것으로 판단된다. 따라서 향후 지하심부의 탐사를 위해 전자탐사법중 TEM 탐사를 실시할 계획이며, 또한 낮은 전기비저항 이상대의 연장성을 정확히 파악하기 위하여 기 측정된 전기비저항 탐사 측선 사이를 탐사할 예정이다.

  • PDF

A Study on the Error Rate of Non-destructive Rebar Detection Under Different Environmental Factors (환경적 요인에 따른 비파괴 철근 탐사의 오차율에 관한 연구)

  • Kang, Beom-Ju;Kim, Young-Hwan;Kim, Young-Min;Park, Kyung-Han;Oh, Hong-Seob
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.506-513
    • /
    • 2021
  • The durability and safety of reinforced concrete structures significantly depend on the reinforcement conditions, concrete cover thickness, cracks, and concrete strength. There are two ways to accurately determine the information on reinforcing bars embedded in concrete - the local destructive method and the non-destructive rebar detection test. In general, the non-destructive rebar detection tests, such as the electromagnetic wave radar method, electromagnetic induction method, and radiation method, are adopted to avoid damage to the structural elements. The moisture content and temperature of concrete affect the dielectric constant, which is the electrical property of concrete, and cause interference in the non-destructive rebar detection test results. Therefore, in this study, the effects of the electromagnetic wave radar method and electromagnetic induction method have been analyzed according to the temperature and surface moisture content of concrete. Due to the technological advancement and development of equipment, the average error rate was less than 5% in the specimens at 24℃, irrespective of their operating principles. Among the tested methods, the electromagnetic induction method showed very high accuracy. The electromagnetic wave radar method indicated a relatively small error rate in the dry state than in the wet state, and exhibited a relatively high error rate at high temperatures. It was confirmed that the error could be reduced by applying the electromagnetic wave radar method when the temperature of the probe was low and in a dry state, and by using the electromagnetic induction method when the probe was in a wet state or at a high temperature.