• Title/Summary/Keyword: 탄소막전극

Search Result 60, Processing Time 0.031 seconds

CO Tolerance Improvement of MEA Using Metal Thin Film by Sputtering Method in PEM Fuel Cell (스퍼터링 공정으로 제조된 금속박막을 이용한 고분자전해질 연료전지 막-전극접합체의 일산화탄소에 대한 내구성 연구)

  • Cho, Yong-Hun;Yoo, Sung-Jong;Cho, Yoon-Hwan;Park, Hyun-Seo;Sung, Yung-Eun
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.279-282
    • /
    • 2007
  • When reformer for fuel cell is used, CO in hydrogen gas leads to a seriously decreased membrane electrode assembly (MEA) performance by catalyst poisoning. The effect of CO on performance of modified MEA by sputtering method is studied in this paper. The experimental results show that sputtered Pt and Ru thin film improve a single cell performance of MEA and sputtered metal thin film has a CO tolerance. The air injection process on anode show improved CO tolerance test result. Moreover, Pt, Ru and PtRu thin film by sputtering had influence on the CO tolerance with air injection process.

Carbon nano-tube as the Counter electrode for Dye-sensitized Solar cell (탄소나노튜브 상대전극을 이용한 염료감응형 태양전지)

  • Koo, Bo-Kun;Lee, Dong-Yoon;Kim, Hyun-Ju;Lee, Won-Jae;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.691-694
    • /
    • 2004
  • 염료감응형 태양전지는 다공질 $TiO_2$ 전극막, 광감응형 염료, 전해질, 상대전극으로 구성된, 전기화학적 원리를 응용한 신형태양전지이다. 염료감응형 태양전지의 상대전극으로 주로 Pt가 사용되고 있는데 본 연구에서는 탄소나노튜브를 사용하여 상대전극으로서의 가능성을 조사하였다. 제조된 탄소나노튜브 상대전극은 cyclic voltammetry와 Impedance spectroscopy을 이용하여 전기화학적 특성을 측정하였다. 또한 탄소 나노튜브 상대 전극이 태양전지의 효율 및 그 특성에 미치는 영향을 알아보기 위하여 단위 셀 태양전지를 제조하여 단파장 하에서의 광전특성을 측정하고, 이를 바탕으로 탄소나노튜브의 상대전극으로서의 가능성을 제시하였다.

  • PDF

A Study of Small Radiation Dosimeter by Using Microfilm and Carbon Elecrtode (마이크로필름과 탄소막 전극을 이용한 소형방사선측정기 개발에 관한 연구)

  • 신교철;윤형근
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.59-62
    • /
    • 2004
  • We developed very small parallel plate radiation detector by using our existing experience of mating radiation dosimeter and capability of analyzing characteristics of dosimeter. The radiation detector was consisted of microfilm and carbon electrode. The detector was parallel plate type of all-filled ionization chamber. The ionization chamber had been fabricated using an acrylic plate for the air cavity and carbon coated microfilm for electrical configuration. The alr gap between two electrodes was 0.48 mm. The diameters of collect electrode and guard electrode were 3.3 mm, 5 mm respectively. The diameter of high voltage electrode was 5 mm. Nominal sensitive volume of the chamber was 0.016 ㎤. The major parameters of the chamber characteristics such as leakage current, reproducibility, dose rate effect, and polarity effect were measured. The experimental results were as followings. Leakage current was 0.1 pA. Standard deviation of reproducibility was less than 0.1%. Dose rate effect was less than 1.5%. Polarity effect was less than 2.4%. These data were comparable to those of commercially available dosimetric system for QA-purpose. As the result, we found that the radiation detector consisting of the ionization chamber, microfilm and carbon electrode, was satisfactory for the purpose of the small field dosimetry in size and characteristics. In the future, We will try to refine the dosimeter for use in very small volume.

  • PDF

Studies on the Anodic Oxidation Behavior of Methanol and L-Ascorbic Acid by Using Glassy Carbon Electrodes Modified with Inorganic-Metal Polymeric Films (무기 금속 고분자 막을 도포시킨 유리질 탄소전극을 이용한 메탄올과 L-ascorbic acid의 양극 산화 거동에 관한 연구)

  • Yoo, Kwang-Sik;Woo, Sang-Beom
    • Analytical Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.347-352
    • /
    • 1998
  • A study was carried out on the elelctrochemical characteristics of chemically modified electrodes (CMEs) by cyclic voltammetry. Fabrication of CMEs was made by coating with mixed valence (mv) inorganic-metal polymeric films on the glassy carbon electrode surface by potential cycling. Anodic oxidation behavior of methanol and L-ascorbic acid was studied by using CMEs working electrode. Deposition of films such as mv ruthenium oxo/ruthenium cyanide film (mv Ru-O/CN-Ru), mv ruthenium oxo/ferrocyanide film (mv Ru-O/$Fe(CN)_6$), and mv ruthenium oxo/ruthenium cyanide/Rhodium film (mv Ru-O/CN-Ru/Rh) was obtained to coat by scan rate of 50 mV/sec within the specified potential range (-0.5V ~ +1.2V). Film thickness was controlled by the repeat of the potential cycling. Anodic oxidation behavior of methanol was as follow. Calibration graph by using mv Ru-O/CN-Ru film showed linearly from 10 mM to 80 mM MeOH with slope factor of $-7.552{\mu}A/cm^2$. Although slope factor by using mv Ru-O/$Fe(CN)_6$ film was $-5.13{\mu}A/cm^2$, yet linear range of calibration graph could be extended from 10 mM to 100 mM MeOH. Anodic oxidation behavior of L-ascorbic acid was studied by mv Ru-O/CN-Ru film on the glassy carbon electrode and the glassy carbon electrode with Rh film, Glassy carbon electrode modified with Ru polymeric film was showed better sensitivity than the Rh-glassy carbon modified electrode (mv Ru-O/CN-Ru/Rh). Calibration graph was linear from 0.1 mM to 5 mM L-ascorbic acid by using glassy carbon electrode modified with Ru polymeric film. Solpe factor and relative coefficient are $-84.78{\mu}A/mM$ and 0.998, respectively.

  • PDF

A study on Stripping Voltammetric Determination of Ag(I) by Poly(3-methylthiophene) Conducting Polymer Film Electrode Containing 18-crown-6 (18-crown-6을 포함하는 poly(3-methylthiophene) 전도성 고분자 막전극에 의한 Ag(I)의 벗김 전압-전류법적 정량에 관한 연구)

  • Lee, Ihn Chong;Sohn, Jeong-In;Kim, Kuk Gin
    • Analytical Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.181-186
    • /
    • 1994
  • Using poly(3-methylthiophene) conducting polymer film electrodes, feasiblity for Ag determination by stripping voltammetry has been studied. Ag ions accumulated by complexation with 18-crown-6, which are existing on the surface of the polymer film electrode, migrate inside of polymer film through potential scanning within limited potential range, and then are reduced and oxidized on the glassy carbon substrate. Therefore, the polymer film must have proper thickness and porosity for easy penetration of Ag ions. On the basis of these experimental results, $5.0{\times}10^{-6}M$ Ag(I) in aqueous solution could be determined.

  • PDF

Electrochemical Properties of Porous Carbon Electrode as a Function of Internal Electrolyte Concentration (전극 내부의 전해질 농도 변화에 따른 다공성 탄소전극의 전기화학적 특성)

  • Park, Byeong-Hee;Choi, Jae-Hwan
    • Applied Chemistry for Engineering
    • /
    • v.20 no.6
    • /
    • pp.700-704
    • /
    • 2009
  • The electrochemical properties of porous carbon electrodes as a function of their internal electrolyte concentration were investigated. Cyclic voltammetry, chronoamperometry, and impedance spectroscopic analysis were conducted for carbon electrodes equilibrated with 0.01, 0.05, 0.1, and 0.5 M KCl solution and covered with a cation-exchange membrane. The specific capacitance of the electrodes increased as the internal electrolyte concentration increased, due to a decrease in charging resistance. Experimental results indicated that the salt removal efficiency of the membrane capacitive deionization process could be enhanced by increasing the internal electrolyte concentration, even for an influent with a low salt concentration.

Electrochemical Characteristics of the MFCs using the Ceramic Membrane as a Separator (세라믹막을 이용한 미생물연료전지의 전기화학적 특성 연구)

  • Lim, Ji-Young;Park, Dae-Seok;Kim, Jin-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5728-5735
    • /
    • 2015
  • This study attempts to verify the applicability of ceramic membrane as a separator by comparing the power generation characteristics in single-chamber MFCs using ceramic membranes to those in the MFCs using nafion membrane. The generated power in MFCs by using acetate as a substrate was more stable than that by using formate, propionate and butyrate, respectively. It was shown that the generated power by using formate substrate in MFCs was unstable and a little higher than that by using acetate, and the power generated by using propionate and butyrate were lower than that by using acetate. In order to find out the Pt catalyst effect, it was compared the power generated in MFCs using Pt-coated carbon cloth as electrode to that power using normal carbon cloth. The power generated in MFCs using Pt-coated carbon cloth as electrode was 1.2 times higher than that using normal carbon cloth. The Pt-coated carbon cloth was about 5 times more expensive than normal carbon cloth. It is suggested that both power generation efficiency and cost together should be considered in selecting electrodes of MFCs. It was found that the ceramic membrane was superior to nafion membrane by comparing to the power generation characteristics obtained. It was shown that average voltage values were $523.67mV{\pm}49.41mV$ by using synthetic wastewater, in MFCs of ceramic membrane as a separator. While average voltage values were $424.09mV{\pm}79.95mV$ by using synthetic wastewater, in MFCs of nafion membrane as a separator. The organic removal efficiency, 41.7% by using ceramic membrane was a little bit higher than 40.8% by using nafion membrane. This research implies ceramic membrane can be a valid alternative to nafion membrane as a separator when considering the power generation and the efficiency of organics removal.

Asher 처리를 통한 Polyimide 표면 최적화

  • Kim, Sang-Seop;Choe, Pyeong-Ho;Choe, Byeong-Deok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.278-278
    • /
    • 2012
  • 최근 폴리이미드(Polyimide) 고분자 물질을 기판으로 하는 플렉시블 전자소자 구현에 관한 연구가 활발히 진행 되고 있다. 폴리이미드는 수분 흡수율이 1% 이하인 소수성 물질로서 폴리이미드 기판 위 전극 형성에 있어 전극 물질이 분리되는 현상이 발생하게 된다. 따라서 본 연구에서는 소수성의 표면 성질을 갖는 폴리이미드 기판의 Asher 처리를 통한 표면 최적화에 대한 실험을 진행하였다. 유리기판 위에 액상 폴리이미드를 ${\sim}10{\mu}m$ 두께로 Spin coating 한 후 $120^{\circ}C$ hot plate에서의 soft bake와 $200^{\circ}C$, $320^{\circ}C$의 furnace에서의 단계적 cure 과정을 통해 표면의 defect을 최소화하였다. Microwave Asher 장비를 이용하여 폴리이미드 막에 10초, 15초, 20초 동안 asher 처리를 한 후 Atomic Force Microscopy (AFM) 장비로 시간에 따른 폴리이미드 기판 표면의 변화를 확인하였다. AFM 확인 결과 10 초의 공정 조건에서 가장 우수한 표면 morphology를 보였으며, 이는 표면의 탄소와 이물질을 제거하기 위해 사용되는 asher 처리 시간이 상대적으로 증가함에 따라 폴리이미드 막의 탄소 성분이 제거 되면서 표면의 형상이 최적화 이상으로 변화하기 때문이다. 본 실험은 폴리이미드를 기반으로 하는 플렉시블 전자소자 구현에 있어 전극 및 소자 제작에 크게 기여할 것으로 판단된다.

  • PDF

Determination of Cr(Ⅵ) by Glassy Carbon and Platinum Electrodes Modified With Polypyrrole Film (폴리피롤 막으로 변성시킨 유리질 탄소 및 백금 전극에서 Cr(Ⅵ) 이온의 정량)

  • Yoo, Kwang Sik;Woo, Sang Beom;Jyoung, Jy Young
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.4
    • /
    • pp.407-411
    • /
    • 1999
  • Studies have been carried out on the fabrication of PPy/GC and PPy/Pt electrode modified with polypyrrole film and determination of Cr(VI) by using 3-electrode system with modified electrodes. Modified electrodes were able to easily fabricated by cyclic voltammetry scanned from +1.0V to -1.0V(vs. Ag/AgCl) at 50 mV/sec. Film thickness could be controlled at same condition by the number of cycling up to 26 times. Reduction behaviour of Cr(VI) at PPy/GC electrode could be seen at wide potential ranges from +0.6V to -0.5V(vs. Ag/AgCl), and maximum reduction peak potential of the ion was observed at -0.25V(vs.Ag/AgCl). Calibration graph at its potential was linear from 0.1 ppm to 80.O ppm. Slope factor and relative coefficient were 1.75 mA/ppm and 0.998, respectively. Reduction behaviour of Cr(VI) at PPy/Pt electrode was similar to PPy/GC electrode, Calibration graph was linear from l.0 ppm to 60.0 ppm. Slope factor and relative coefficient were 0.5mA/ppm and 0.923, respectively. But PPy/GC modified electrode had about 3 times higher sensitivity than PPy/Pt modified electrode. Reduction behaviour of Cu(II), As(IlI), Pb(II), and Cd(II) couldn't be seen at PPy/GC electrode,Its metals had not lnterfered with Cr (VI) determination.

  • PDF

Performance Study of Membrane Capacitive Deionization (MCDI) Cell Constructed with Nafion and Aminated Polyphenylene Oxide (APPO) (Nafion과 Aminated Polyphenylene Oxide (APPO)를 적용한 막 축전식 탈염 공정의 성능 연구)

  • Kim, Ji Su;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.30 no.5
    • /
    • pp.350-358
    • /
    • 2020
  • A membrane capacitive deionization (MCDI) cell is constructed by applying thin layer of a cation exchange membrane (Nafion) on cathode and an anion exchange membrane (aminated polyphenylene oxide, APPO) on anode. Compared to CDI cell without CEM and AEM coating, MCDI exhibits enhanced salt removal efficiency. When Nafion and APPO are used as CEM and AEM, optimized salt removal performance as high as 82.1% is observed when 1.2 V is applied for 3 min during absorption process and -1.0 V is applied for 1 min during desorption.