• Title/Summary/Keyword: 타워 구조물

Search Result 64, Processing Time 0.028 seconds

Modal Property Estimation of Tapered Cantilever Pipe-type Cracked Beam (테이퍼 캔틸레버 원형강관 균열보의 모드특성 추정)

  • Lee, Jong Won;Kim, Sang Ryul;Kim, Bong Ki
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.5
    • /
    • pp.361-368
    • /
    • 2014
  • Modal properties for tapered cantilever pipe-type beam is identified by applying the boundary conditions to a general solution for tapered beam. A bending stiffness for cracked beam is constructed based on an energy method for tapered cantilever thin-walled pipe, which has a through-the-thickness crack, subjected to bending. Then the natural frequencies and mode shapes of a tapered cantilever thin-walled cracked pipe are identified. It can be found that the phenomenon of the bending stiffness distribution along the beam length of the cracked beam is quite reasonable, the natural frequencies are decreased as the crack sizes are increased, and the mode shapes are changed due to the crack. This results may be used to the vibration-based crack identification for the tapered cantilever pipe-type tower structures.

An Experimental Evaluation on Flexural Performance of Light-Weight Void Composite Floor using GFRP (GFRP를 이용한 경량합성바닥의 휨성능에 대한 실험적 평가)

  • Ryu, Jae-Ho;Park, Se-Ho;Ju, Young-Kyu;Kim, Sang-Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.1
    • /
    • pp.125-135
    • /
    • 2011
  • To obtain a lower story height with a long span and better fire resistance, a new composite floor system using GFRP (glass-fiber-reinforced plastics) was proposed. This floor system consists of asymmetric steel with a web opening, a hollow core ball, concrete, and GFRP. To evaluate the flexural performance of the new composite floor system, an experiment was conducted. The test parameters were the presence of GFRP, the void ratio in relation to the hollow core balls, and the web opening. The test results showed that the resistance and stiffness of the specimen with GFRP were 10% higher than those of the reference specimen, and that fully composite action was accomplished up to the yielding point. After the attainment of the yield strength, the ductility of the specimen was reduced due to the stress concentration around the web openings. The slip between the concrete and steel beam, however, was small. Thus, in the design of the proposed new floor systems, it is desirable that the calculated resistance be reduced by 15%, for safety.

Development of a Health Monitoring System for Critical Parts of Wind Turbine Towers and Foundation Structures (풍력발전기 타워 및 기초 취약부 건전성 모니터링 시스템 개발)

  • Jaehun Jeong;Moonok Kim;Jongho Park;Seok-Young Jeong
    • Journal of Wind Energy
    • /
    • v.15 no.2
    • /
    • pp.23-36
    • /
    • 2024
  • In this study, a health monitoring system was developed for the two most vulnerable parts of a wind tower support structure: the connection between steel towers (L-Flange) and the concrete foundation-steel tower connection. To select assessment parameters for health monitoring, detailed FEM analysis was conducted using the ABAQUS program. Additionally, a testbed was established near the Jeju Woljeongri wind turbine farm to evaluate the applicability of measurement data by installing sensors. Through computational analysis and relevant criteria review, we defined limits for measurement parameters by vulnerable section. We categorized the structural safety evaluation into four stages: normal, caution, warning, and danger, and selected management criteria for each stage. From this, an algorithm to evaluate safety was developed, and a visualized monitoring platform based on the established critical parts monitoring system was developed.

A Study on a Nonlinear Cable Finite Element (非線形 케이블 有限要素에 관한 硏究)

  • 장승필;박정일
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.1 no.1
    • /
    • pp.93-101
    • /
    • 1989
  • A geometrically nonlinear cable finite element is presented to use in the static or dynamic modeling of offshore and onshore structures such as guyed tower, tension leg platform or mooring buoy, submarine cable, cable-stayed bridge, suspension bridge, cable roof and so on. The cable finite element is derived directly from the compatibility equations and flexibility matrix of elastic catenary cable theory for the arbitary plane loading and geome try. A general and virsatile computer program has been developed to perform the analyses of cable member itself or cable guyed or suspened structures, in which Newmark-$\beta$ method is used to obtain a time domain solution and Newton-Raphson iteration method is used to solve the nonlinear system of compatibility equations of cable and algebraic static or dynamic equations at each time step. The results from the static and dynamic analysis of a cable member by the computer program are summarized and presented.

  • PDF

Proposal for Research Model of Agricultural and Fishery Farm Tower (수직형 농축수산 팜의 연구 모델 제안)

  • Young-Su Lee;Seung-Jung Shin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.3
    • /
    • pp.69-76
    • /
    • 2024
  • This dissertation developed a five-story vertical livestock and fisheries farm (palm tower) model for sustainable food production in cities. It proposes to integrate marine farms, livestock raising, and pesticide-free automated crop farms to efficiently use resources and minimize environmental impact. Based on circular economy principles, the model can recycle the output of each part into resources from the other, increasing the efficiency of the system, utilizing idle space in the city, and promoting job creation and community participation. It can also contribute to reducing the carbon footprint of food production and improving food safety. In addition, the study explores how advanced agricultural technologies can be integrated into urban structures to address global food security challenges. This model presents potential solutions to the food crisis caused by climate change and population growth, and suggests a direction for the development of urban agriculture. Future research should address the technical and policy challenges for practical implementation.

Study on Behavior Characteristics of L-Type Flange Bolt Connection for Supporting Structures of Wind Turbines (풍력터빈 지지구조물 L형 플랜지 볼트 접합부의 거동 특성에 관한 연구)

  • Jung, Dae-Jin;Hong, Kwan-Young;Choi, Ik-Chang
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.5
    • /
    • pp.279-286
    • /
    • 2021
  • In this study, we investigated the behavior characteristics of the L-type flange bolt connection, which is used to connect upper and lower flanges having L-type ring sections, by bolts. This connection is mainly used in domestic wind turbine structures, wherein it is a vital component as any imperfection could cause the collapse of the entire structural system. Therefore, understanding the behavior characteristics of the L-type flange bolt connection is imperative. In this study, the connection's response to external force was simulated using finite element (FE) analysis and the FE model was idealized to behave as a single L-type bolt flange. The variation in the bolt tension and the L-type flange stress were analyzed to understand the behavior characteristics of the connection. Moreover, the bolt-load function models proposed by Petersen, Schmidt/Neuper and VDI 2230, theoretically expressing a relation between bolt tension and external force, were compared to evaluate the suitability of the FE analysis and analyze the significant behavior characteristics of the connection. Furthermore, the changes in the bolt-load curve due to the variations in the partial dimensions of the L-type flange bolt connection were analyzed.

Behavior Characteristics of Shear Connector for Composite Behavior of Steel Composite Columns (강합성 부재의 합성거동을 위한 전단 연결재의 거동 특성)

  • Won, Deok Hee;Han, Taek Hee;Kim, Seungjun;Lee, Jung Hwa;Kang, Young Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1993-1999
    • /
    • 2013
  • Steel composite structures have been studied in various areas such as bridges, high rise buildings, and wind towers. They show excellent structural performance through overcoming of the weaknesses of steel and concrete. Although various methods were already developed to achieve full composite behavior between steel and concrete in flexural members, the number of studies regarding composite columns is quite limited. If slip occurs between concrete and steel under external loads, the performance of the composite column would be reduced significantly. Connection methods ensuring full composite action between steel and concrete must be suggested. This paper investigated about structural behavior of shear studs through a series of experimental tests. Extensive parameters were also performed to understand the effects of the diameter of stud, space of stud and height of concrete. The present study provides fundamental bases for further development of design method of shear studs in composite columns.

Alternative Design of Mega Structural Members of a Super-tall Building using 800MPa Grade High-performance Steel Plate (800MPa급 고성능 강재 적용한 초고층 메가 부재 대안설계)

  • Cho, So Hoon;Kim, Do Hwan;Kim, Jin Won;Lee, Seung Eun;Kim, Jin Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.4
    • /
    • pp.299-309
    • /
    • 2014
  • HSA800 is a new high strength steel (HSS) plate for building structures developed by POSCO and RIST in 2011. It has upper and lower bounds for yield ($F_y$) and tensile ($F_u$) strength as of 650-770MPa and 800-950MPa, respectively, with yield ratio ($F_y/F_u$) limit as of 0.85 which make steel quality more reliable and enhance the seismic resistance of structures. As made by TMCP, it has a good weldability without increasing carbon percentage. The objective of this study is to provide alternative design of mega-structural members of the Lotte World Tower (555m, 123 story), a first super-tall building in Korea, using HSS considering structural safety, constructability, and cost-effectiveness. Steel outrigger trusses, belt-trusses and steel exterior columns were selected and analyzed to evaluate the structural performance between original and alternative designs using HSS. The results show that HSS can be applied to the members which do not affect lateral stiffness of a building and, in this study, approximately 1100tons of steel were saved. It implies that HSS can save overall construction costs - manufacturing, delivery, and erection costs - by reducing mega structural member size. HSA800 was very first applied to the Lotte World Tower based on the results of this study.

Bearing Capacity of a Monopod Bucket Foundation for Offshore Wind Towers - Centrifuge and Numerical Modeling (해상풍력 모노포드 버켓기초의 지지력 거동 - 원심모형실험 및 수치해석)

  • Kim, Dong-Joon;Choo, Yun Wook;Kim, Surin;Kim, Jae-Hyun;Choi, Ho-Young;Kim, Dong-Soo;Lee, Man-Soo;Park, Yung-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.4
    • /
    • pp.23-32
    • /
    • 2013
  • In order to evaluate the bearing capacity behaviour of a monopod suction bucket foundation for an offshore wind tower at the western sea of Korea, a centrifuge load test and numerical analyses were performed. The monopod bucket foundation was designed to be installed in a silty sand layer. The model soil was prepared to simulate a target site by using soil samples having similar properties and controlling relative density. In-flight miniature cone penetration test and bender element array were used to confirm that the model soil had represented the target site conditions. The load - rotation curve of the centrifuge load test was analysed. A series of numerical analyses were performed to validate the experimental conditions. Self-weight of the model, distance to the boundary and elastic modulus of the soil layer were varied to study their effects on the load - rotation curves.

Pile and adjacent ground behaviors depending on horizontal offset between pile and tunnel subjected to horizontally loaded single pile (수평하중을 받는 단일 말뚝 하부 터널굴착 시 말뚝-터널 수평이격거리에 따른 말뚝 및 인접 지반 거동)

  • Ahn, Ho-Yeon;Oh, Dong-Wook;Lee, Yong-Joo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.5
    • /
    • pp.685-703
    • /
    • 2017
  • Recently, as the number of high-rise building and earthquake occurrence are increasing, it is more important to consider horizontal load such as wind and seismic loads, earth pressure, for the pile foundation. Also, development of underground space in urban areas is more demanded to meet various problem induced by growing population. Many studies on pile subjected to horizontal load have been conducted by many researchers. However, research regarding interactive behavior on pile subjected to horizontal load with tunnel are rare, so far. In this study, therefore, study on the behaviors of ground and horizontal and vertical loads applied to single pile was carried out using laboratory model test and numerical analysis. The pile axial force and ground deformation were investigated according to offset between pile and tunnel (0.0D, 1.0D, 2.0D: D = tunnel diameter). At the same time, close range photogrammetry was used to measure displacement of underground due to tunnelling during laboratory model test. The results from numerical analysis were compared to that from laboratory model test.