• Title/Summary/Keyword: 콘크리트 코어

Search Result 149, Processing Time 0.023 seconds

Development of Forms for Cold Weather Concrete by Combination of Insulation (단열재 조합에 의한 한중콘크리트용 거푸집 개발)

  • Han, Cheon-Goo;Oh, Seon-Kyo;Sin, Dong-An;Kim, Kyoung-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.3
    • /
    • pp.392-399
    • /
    • 2003
  • This paper discusses the validities of insulating curing of cold weather concreting at early stage by applying insulation forms. Tests were carried out using modified insulating form combining existing insulating form and various other insulations in order to develop improved insulation form. Temperature history of concrete using various insulating forms and insulation was measured to determine most effective combination of insulting form. According to results, as for the wall form, under the curing temperature of $-10^{\circ}C$, the temperature of concrete using Euro form drops sharply before 24 hours and lasts below $0^{\circ}C$ for 7 hours. The temperature of concrete using the form combining Polypropylene panel, styrofoam and plywood panel keep above $0^{\circ}C$. And, it is confirmed that the form mentioned above has a favorable effects on enhancing strength development of concrete and the cost to make the forms shows more reasonable than that of existing forms. However, as for the combination methods of insulation form for slab, which is composed of insulating form at the bottom of slab and various surface curing materials at the top of slab, in case of exposed condition at the top of slab, temperature history of concrete goes below $0^{\circ}C$ after 10 hours. In case of the combination of vinyl sheet and curing blanket, it drops below $0^{\circ}C$ after 42 hours. However, in case of the combination of vinyl, styrofoam and curing blanket, it does not go below $0^{\circ}C$ until 55 hours. Accordingly, compared to the case of exposure and the combination of vinyl and curing blanket, it indicates that the combination mentioned above has more effective insulating performance.

Estimation of Long-term Aging Compressive Strength Through Non-Destructive Testing of Concrete Structure Using Mineral Admixtures (혼화재를 사용한 콘크리트 구조체의 비파괴 시험에 의한 장기재령 압축강도 추정)

  • Kim, Jeong-Sup;Shin, Yong-Seok;Lee, Chang-Hyun;Lee, Seung-Jung;Kim, Kwang-Seok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.5
    • /
    • pp.426-434
    • /
    • 2011
  • Recently, the use of mineral admixtures in concrete has been studied in many laboratories, and been applied in the field. But the non-destructive testing equation proposed in Japan for normal strength concrete has been used to determine compressive strength, because there has been a lack of systematic research on the compressive strength of concrete using mineral admixtures. For this reason, it is essential to suggest a non-destructive testing equation to estimate the compressive strength of concrete using mineral admixtures. Therefore, this study made a cylindrical specimen and core tube specimen of concrete using a mineral admixture, and suggested a strength estimation of long-term age (4 years) through non-destructive and destructive tests. The results of the research are as follows. Comparing error rates between conventional suggested equations and this estimated equation shows some differences by age, but the error rate of this study was reduced to 0.3 %~115.0 % compared to conventional equations by re-bound hammering, 0.2 %~22.8 % by the ultrasound velocity method and 0.5 %~102.3 % by complex method. Accordingly, it is judged to be suitable for assessing the compressive strength of concretes using mineral admixtures.

Analysis of Correlation between Freeze-Thaw Damage on Concrete and Chloride Penetration Acceleration Effect Using Surface Rebound Value (표면반발경도 활용 콘크리트 동해손상과 염분 침투 가속효과의 상관관계 분석)

  • Park, Ji-Sun;Lee, Jong-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.148-156
    • /
    • 2022
  • Although most domestic concrete structures are simultaneously exposed to freeze-thaw and chloride environments, concrete durability in the field is evaluated by each single action, and the evaluation of chloride-caused damage of concrete requires additional indoor experimental analysis of chloride contents by coring samples from structures in the field. However, in Korea, policies to strengthen facility maintenance, such as 「Special Act on the Safety Control and Maintenance of Establishments」 and 「Framework Act on Sustainable Infrastructure Management」, have been established and implemented since 2018 and facilities subject to safety inspection management by the government and local governments increases, the effective simplification technology for the inspection and diagnosis of concrete structure is needed. Therefore, this study attempted to evaluate the possibility of determining the acceleration chloride penetration of freeze-thaw damaged concrete by using the surface rebound value. For this purpose, concrete specimens already having freeze-thaw damage by exposure to the freeze-thaw acceleration environment were immersed in chloride water. After that, the acceleration relationship of chloride penetration according to freeze-thaw damage was analyzed using the amount of chloride contents in concrete.

Productivity Analysis of Reinforced Concrete Works and Tower Crane Working Ratio for High-rise Apartment Buildings (초고층 공동주택 RC 공사의 생산성 및 타워크레인 가동율 분석)

  • Kwon, Jihun;Huh, Youngki
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.1
    • /
    • pp.55-62
    • /
    • 2021
  • The productivity of rebar-work and form-work was analyzed with data collected from an actual high-rise construction project, and the actual utilization rates of three tower cranes were also investigated. It was found that the average productivity of the form-work increased from 12.00~8.71(㎡/man·day) in the underground and above-ground/lower-floor to 11.94~20.73(㎡/man·day) in the standard floor. Comparing the productivity of core area to outer, the former was found to be about 11% higher. Moreover, the rebar-work productivity of the outer area(1.12 ton/man·day) was approximately 9.6% higher than that of the core area for the standard floor. The average utilization rates of three TC were surveyed to be about 63.49%, and it was revealed that rainy weather(6.1%), strong winds(6.1%), holidays(17.8%), TC lifting work(5.8%), and other failures and repairs(0.07%) were the causes of non-operation. These research results are expected to be beneficial data in planning and managing the process of high-rise RC construction works in the future.

Evaluation of Minimum Spiral Reinforcement Ratio of Circular RC Columns (철근콘크리트 원형기둥의 나선철근 최소철근비에 대한 평가)

  • Kim, Young-Seek;Kim, Hyeong-Gook;Park, Cheon-Beom;Kim, Sang-Woo;Kim, Kil-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.1-9
    • /
    • 2017
  • Spiral reinforcement in a circular column plays an effective role in the ductile behavior of a column through position fixing and buckling restraining of the longitudinal reinforcement, and confining core-concrete. Each country has suggested the minimum volumetric ratio of spiral reinforcement in order to secure the ductility of concrete columns. The minimum volumetric ratio of spiral reinforcement suggested by ACI 318-14 and the national concrete structure design standard was developed based on the theory of Richard et al. (1928); furthermore it has been used until now. However, their theory cannot consider the effects of high strength concrete and high strength reinforcement, and arrangement condition of the spiral reinforcement. In this study, a modified minimum volumetric ratio equation is suggested, which is required to improve the ductility of reinforced concrete circular columns and to recover their stress. The modified minimum volumetric ratio equation suggested here considers the effect of the compressive strength of concrete, the yield strength of spiral reinforcement, the cross sectional area of columns, the pitch of spiral reinforcements and the diameter of spiral reinforcement. In this paper, the validity of the minimum volumetric ratios from ACI 318-14 and this study was investigated and compared based on the results of uniaxial compression experiment for specimens in which the material strength and the spiral reinforcements ratio were used as variables. In the end of the study, the modification method for the suggested equation was examined.

Early Frost Damage and Diagnose of Damage Depth Due to Early Frost Damage of the Concrete According to the Thickness of Members (부재 두께 변화에 따른 콘크리트의 초기동해 특성 분석 및 깊이진단)

  • Kim, Tae-Woo;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.2
    • /
    • pp.131-138
    • /
    • 2019
  • Recently, there are many structures exposed to severe outdoor environments, which results in rapid degradation of durability of the concrete structures. there can be rapid deterioration of the concrete structures from early frost damage due to the insufficient curing in low outdoor temperature condition. The objective of this study is to investigate the effect of thickness change conditions and binding material on early frost damage depth of the concrete exposed to cold weather in winter, and is to clearly assess damage depth of the concrete structure due to early frost damage. Specimens with 300x300x(150, 200, 250, 300mm) were prepared. OPC and OPC+FA+BS were adopted for binders. Test results indicate that the depth of the early frost damage was deeper with the decrease of thickness of members. The brightness of specimens were reduced when the member thickness was thinner. When determining the depth of early frost damage, it can be distinguished into dark color and relatively bright color when dried for approximately 30 minutes in the indoors of $20^{\circ}C$ in temperature and 60% in relative humidity after submerging in water for 24 hours. The dark colored part can be determined easily when measured with vernier calipers.

The Application of Post-tensioned Slab System to Tall Buildings (초고층 건축물의 포스트텐션 슬래브 시스템 적용)

  • Chung, Kwang-Ryang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.879-882
    • /
    • 2008
  • The market of Korea of post-tension system for building is growing up since 2000 and many engineers and construction companies show interest in it. This paper introduces the structure system and construction of post-tension tall buildings including recent trend in the industry of post-tension system for buildings in Korea and the point to be considered when design post-tensioned tall building. Park Polis is composed of two towers of 39 stories with a level to the top of the roof +144m and is currently under construction at Ulsan in Korea. This building designed as the unbonded post-tension floor system and will be the tallest and first high-rise post-tensioned building in Korea. The structural system is composed of the flat slabs, perimeter columns and core walls. At first, this building had designed as regular RC flat slab with perimeter beams. However, floor structure system was reconsidered because the construction company wants to improve efficiency of construction. As a result, the floor system of PARK POLIS re-designed as PT flat slab.

  • PDF

Suggestion of the Prediction Model for Material Properties and Creep of 60~80MPa Grade High Strength Concrete (설계기준강도 60~80MPa급 고강도콘크리트의 재료 특성 및 크리프 예측모델식 제안)

  • Moon, Hyung-Jae;Koo, Kyung-Mo;Kim, Hong-Seop;Seok, Won-Kyun;Lee, Byeong-Goo;Kim, Gyu-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.6
    • /
    • pp.517-525
    • /
    • 2018
  • The construction of super tall building which structure is RC and must be certainly considered on column shortening estimation and construction reflected concrete creep has been increased. Regarding the Fck 60~80MPa grade high strength concrete applied in the domestic super tall building project, the mechanical properties and creep deflection according to curing conditions(Drying creep/Basic creep) were reviewed in this research. Results of compressive strength and elastic modulus under sealed curing condition were 5% higher than unsealed condition and difference of results according to the curing condition was increased over time. Autogenous and drying shrinkage tendency showed adversely in the case of high strength concrete. Additionally, creep modulus under unseal curing condition was evaluated 2~3 times higher than sealed condition. Modified model of ACI-209 based on test result was applied to estimate long period shortening of vertical members(such as Core Wall/Mega Column) exactly, it is designed to modify and suggest the optimal creep model based on various data accumulated during construction, in the future.

Visualization of Self-Healing Function of Protective Coating for Concrete (콘크리트 보호코팅재의 자기치유 기능의 시각화)

  • Kim, Dong-Min;Choi, Ju-Young;Jin, Seung-Won;Nam, Kyeong-Nam;Park, Hyeong-Joo;Chung, Chan-Moon
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.10
    • /
    • pp.87-93
    • /
    • 2019
  • Microcapsules were prepared by using a mixture of linseed oil and a small amount of fluorescent fluid as a core material. Self-healing protective coatings were prepared by applying coating formulations containing varying amounts of microcapsules on mortar surface. After scratch or crack was generated in the coating, when the damaged region was exposed to ultraviolet light (${\lambda}=365nm$), it was observed that fluorescence emission area increased with increasing microcapsule loading. In the cases of the self-healing coatings having 20wt% or more microcapsule loading, the damaged region was almost filled with the healing agent. In water sorptivity test, the self-healing coating having 20wt% or more microcapsule loading showed a healing efficiency of about 85%. The fluorescence emission from the damaged region was easily observed at a distance of 3 m. The self-healing protective coating is expected to be useful to confirm its self-healing function with the eye.

A Study on the Controller of Core-Drill for Concrete-Wall (콘크리트벽 천공용 코어드릴의 제어기에 관한 연구)

  • Kim, J.S.;Lee, H.G.;Nam, S.B.;Ma, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.191-193
    • /
    • 2006
  • We use electric drill for cutting wood. In electric drills, there is the core-drill that bores concrete-wall. The core-drill is used in construction or remodeling areas. Therefore we require safety in working with the core-drill. In this paper, new controller of core-drill for concrete-wall is proposed. Experimental results show the validity of the proposed controller.

  • PDF