• Title/Summary/Keyword: 콘크리트 양생

Search Result 741, Processing Time 0.025 seconds

Evaluation of Field Application on the Prediction Method of Early-age Strength of Early Concrete for Construction Work Period Reduction (공기단축 조강콘크리트의 조기강도 예측기술의 현장적용성 평가)

  • Lee, Woong-Jong;Keum, Kyoung-Hun;Lee, Jae-Hyun;Jung, Yang-Hee;Kim, Yong-Ro
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.443-444
    • /
    • 2010
  • In this study, It is confirmed the validity for determination of the form removal time, utilizing prediction expression for early-stage strength which depended on the variation of curing history for early strength concrete which be passible to construction work period reduction, in apartment.

  • PDF

Real-time Curing Monitoring of High Strength-Concrete using Piezoelectric Sensors (압전센서를 이용한 고강도 콘크리트 양생의 상시 모니터링)

  • Kim, Dong-Jin;Jang, Ha-Joo;Kim, Joo-Won;Kim, Tae-Hun;Park, Seung-Hee
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.441-442
    • /
    • 2010
  • Recently, it is a trend to construct high rise buildings or wide-span bridges by using High Strength Concrete (HSC). But the HSC is going to be susceptible to brittle fractures if it has not taken enough curing process. Therefore, this study proposes a real-time online monitoring technology using piezoelectric sensors for more reliable and economical monitoring of the curing process of the HSC.

  • PDF

An Experimental Study of Precast Concrete Alters Cement Types of High-Strength Concrete (시멘트종류를 변화시킨 프리캐스트 고강도 콘크리트의 실험적 연구 - 압축강도특성을 중심으로 -)

  • Park, Heung-Lee;Ki, Jun-Do;Kim, Sung-Jin;Lee, Hoi-Keun;Park, Byung-Keun;Jung, Jang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.65-68
    • /
    • 2009
  • Recently, as architectural concrete structures become high-rise and megastructured, concrete become high-strengthened and, by ensuring products of more stability, and rationalization of construction are required.large cross-sectional precast concrete members such as columns show large temperature increase in manufacturing process not only by external heating but also by concrete itself's hydration heating. Therefore, it is expected that specimen for management to predict strength and compression strength of precast concrete member shows different strength characteristics. Concerning this, in order to suggest strength characteristics of high strength mass concrete suitable for precast concrete application, this study comprises the inclusive investigations on the relations between core strength and the strength characteristics per member cross-section dimensional value and per water-bonding material ratio value.

  • PDF

Study on the Optimal Mix Proportions of Lightweight Foam Concrete for Substitution of ALC (ALC 대체를 위한 선발포 경량기포콘크리트의 최적배합 선정 연구)

  • Choi, Sun-Mi;Kim, Beom-Soo;Kim, Jin-Man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.199-200
    • /
    • 2023
  • This paper presents a study on the selection of optimal mix proportions for producing lightweight pre-foam concrete as a substitute for Autoclaved Lightweight Concrete (ALC) without the accelerated curing. The study was conducted using a rapid hardening binder made from by-products of the steel industry as the primary raw material. The experimental results established the optimal mix proportions, which included retarder content, water/binder ratio, foam content, and fiber inclusion amount, for the production of lightweight foam concrete. The optimal mix proportion was determined to have a retarder content at the minimum amount required to secure the working time, W/B of 35%, a foam content limited to 65% or less, and a fiber inclusion amount of 0.05% or less.

  • PDF

Application of High Strength Concrete with 40MPa Compressive Strength to the Concrete Bridge Piers (설계강도 40MPa 고강도 콘크리트를 적용한 교량 교각 구조물의 시험시공)

  • Cheong, Hai-Moon;Ahn, Tae-Song;Kwon, Young-Rak;Whang, Jae-Hui;Suh, Bong-Young;Shim, Gi-Sul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.159-160
    • /
    • 2009
  • The application of 40MPa high strength concrete was accepted as a goal for improving durability and reducing column's section in concrete bridge piers. As a result of applying 40MPa high strength concrete, it could be achieved that column diameter and coping height were reduced into 0.6m, 0.4m, respectively. And crack by heat evolution of hydration did not generate, because of a careful quality and curing control of high strength concrete.

  • PDF

Diffusion Characteristics for Chloride Ion of Concrete Subjected to Sulfate Attack (황산염 침투를 받은 콘크리트의 염소이온 확산특성)

  • Park, Jae-Im;Bae, Su-Ho;Yu, Jae-Won;Lee, Kwang-Myong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.213-214
    • /
    • 2010
  • An objective of this experimental research is to investigate the diffusion characteristics for chloride ion of concrete subjected to sulfate attack. For this purpose, concretes with three types of cement such as ordinary portland cement(OPC), binary blended cement(BBC), and ternary blended cement(TBC) containing mineral admixtures were made for water-binder ratios of 32% and 43%. The concrete specimens were immersed in sulfate solution for 365 days, and then the resistance against chloride ion penetration of them were estimated by using NT BUILD 492. It was observed from the test results that the resistance to chloride ion penetration of concrete subjected to sulfate attack was greatly decreased than that of standard curing concrete under the same age.

  • PDF

Chloride Diffusion Coefficient Evaluation in 1 Year-Cured OPC Concrete under Loading Conditions and Cold Joint (하중조건과 콜드조인트를 고려한 1년 양생된 OPC 콘크리트의 염화물 확산계수 평가)

  • Oh, Kyeong-Seok;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.21-29
    • /
    • 2017
  • Cold joint caused by construction delay is vulnerable to shear stress and it allows more rapid chloride penetration and diffusion. In the paper, investigation of chloride diffusion coefficient is performed for 1-year cured concrete considering compressive and tensile loading level and cold joint. The results are compared with the previous results in 91-day cured concrete. In the 1-year cured concrete without loading, 10.7% and 10.5% of diffusion reduction are evaluated for those in 91-day cured concrete, respectively. The reduction ratios are almost similar however the result in cold joint concrete shows much higher values. The results in 1-year cured concrete under 30% and 60% of compressive loading show reduction of chloride diffusion by 10.9% and 5.8% compared with 91-day cured results, which is caused by steady hydration of cement particles, so called, time effect. In the case of tensile loading, the differences in results are not significant regardless of time effect and cold joint since micro cracks which is weak point of concrete is much dominant despite of long term curing.

A Study on the Development of Strength Prediction Model and Strength Control for Construction Field by Maturity Method (적산온도 방법에 의한 강도예측모델 개발 및 건설생산현장에서의 강도관리에 관한 연구)

  • Kim, Moo-Han;Jang, Jong-Ho;Nam, Jae-Hyun;Khil, Bae-Su;Kang, Suk-Pyo
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.87-94
    • /
    • 2003
  • Construction plan and strength control have limitations in construction production field because it is difficult to predict the form removal strength and development of specified concrete strength. However, we can have reasonable construction plan and strength control if prediction of concrete strength is available. In this study, firstly, the newly proposed strength prediction model with maturity method was compared with the logistic model to test the adaptability. Secondly, the determination of time of form removal was verified through the new strength prediction model. As the results, it is found that investigation of the activation energy that are used to calculate equivalent age is necessary, and new strength prediction model was proved to be more accurate in the strength prediction than logistic model in the early age. Moreover, the use of new model was more reasonable because it has low SSE and high decisive factor. If we adopt new strength prediction model at construction field, we can expect the reduced period of work through the reduced time of form removal.

Lateral Behavior of Abutment Piles in Full Integral Bridge During 7 Days in Response to Hydration Heat and Drying Shrinkage (수화열과 건조수축에 의한 7일간의 완전 일체식 교량 교대 말뚝기초의 횡방향 거동)

  • ;;;;Thomas A. Bolte
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.127-149
    • /
    • 2003
  • The bridge tested was 3 spans 90m-long PSC beam concrete bridge with a stub-type abutment which had a skew of 60$^{\circ}$ about the axis of bridge. A cement concrete was placed at the superstructural slab of the bridge. Inclinometers and straingauges were installed at piles as well. During 7 days-curing of superstructural slab, the pile behavior in response to hydration heat and drying shrinkage of the slab was monitored. Then monitored values were compared with the horizontal movement obtained from the HACOM program and the calculated lateral behavior obtained from the nonlinear p-y curves of pile. As a result, lateral behavior of H-piles by the field measurement occurred due to the influence of hydration heat and drying shrinkage obtained during curing of superstructural concrete. The lateral displacements by hydration heat and drying shrinkage were 2.2mmand 1.4mm respectively. It was observed as well that the inflection point of lateral displacement of pile was shown at 1.3m down from footing base. It means that the horizontal movement of stub abutment did not behave as the fixed head condition of a pile but behave as a similar condition. The measured bending stress did not show the same behavior as the fixed head condition of pile but showed a similar condition. The increment of maximum bending stress obtained from the nonlinear p-y curves of pile was about 300(kgf/$\textrm{km}^2$) and was 2 times larger than measured values regardless of installation places of straingauges. Meanwhile, lateral load, maximum lateral displacement, maximum bending stress and maximum bending moment of pile showed a linear behavior as curing of superstructural concrete slab.

Crack and Time Effect on Chloride Diffusion Coefficient in Nuclear Power Plant Concrete with 1 Year Curing Period (1년 양생된 고강도 원전 콘크리트의 염화물 확산에 대한 균열 및 시간효과)

  • Chun, Ju-Hyun;Ryu, Hwa-Sung;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.83-90
    • /
    • 2017
  • Concrete structure for nuclear power plant is mass concrete structure with large wall depth and easily permits cracking in early age due to hydration heat and drying shrinkage. It always needs cooling water so that usually located near to sea shore. The crack on concrete surface permits rapid chloride intrusion and also causes more rapid corrosion in the steel. In the study, the effect of age and crack width on chloride diffusion is evaluated for the concrete for nuclear power plant with 6000 psi strength. For the work, various crack widths with 0.0~1.4 mm are induced and accelerated diffusion test is performed for concrete with 56 days, 180days, and 365 days. With increasing crack width over 1.0mm, diffusion coefficient is enlarged to 2.7~3.1 times and significant reduction of diffusion is evaluated due to age effect. Furthermore, apparent diffusion coefficient and surface chloride content are evaluated for the concrete with various crack width exposed to atmospheric zone with salt spraying at the age of 180 days. The results are also analyzed with those from accelerated diffusion test.