• Title/Summary/Keyword: 콘크리트 공동

Search Result 229, Processing Time 0.021 seconds

A Study on the Performance Evaluation of Waterproof Sealant Materials for the Exterior Wall of PC Apartment House (PC 공동주택 외벽용 방수 실란트 자재의 성능 평가 연구)

  • Ko, Hyo-Jin;Kim, Yong-Ro
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.221-222
    • /
    • 2023
  • In this study, the performance evaluation of waterproof sealant materials applied to the outer wall of PC apartment houses was conducted. The sealant for PC members must have resistance to movement, and since it is exposed to outside air, weather resistance and water resistance are required.

  • PDF

A Study of Crack Shape Analysis based on Properties of Member in Apartment Exterior Wall (부재속성에 따른 균열 형상 분석에 관한 연구 - 공동주택 외벽 균열을 중심으로 -)

  • Kim, Man-Jang
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.3
    • /
    • pp.143-151
    • /
    • 2015
  • The Crack, occurred in the concrete structure, is a major cause of function deterioration such as strength, durability and waterproof. Therefore the need for crack reduction will continue as long as there is concrete structure. But, it is not easy to reduce or prevent crack cause of impact factor of it. There are so many factors of crack such as material, construction and maintenance environment, and structure, and these are acting in combination. So, this study derives a correlation between the cracks and members through reviewing member crack occurred. And member's attribute, related crack, is analyzed by it. It consider that the basic attribute of member is similar when its requirements are similar. Through this study, therefore, foundation of countermeasure of crack will be provided by prediction of crack shape through member's attribute.

Evaluation on the Behaviors of Precast Concrete Beam-Column Connections for Apartments (공동주택용 프리캐스트 콘크리트 보-기둥 연결부의 거동분석)

  • Song, Hyung-Soo;Yu, Sung-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.5 s.95
    • /
    • pp.657-666
    • /
    • 2006
  • The precast concrete beam-column connectors to retrofit an apartment building were investigated experimentally. Five precast concrete beam-column connectors were considered to develop a modified model which was adapted to domestic construction conditions from the DDC(dywidag ductile connection) of Germany. Special H-shape steel hardware was used to decrease the width of column and beams for the construction of external frames in apartments. It was found that the DDC had high joint strength and ductility, however failed in inclined shear crackings in the columns. The modified one showed better behaviors in tests because they did not show critical column crackings at failure. The test result of modified one with grouting was compared to that of the one without grouting within the duct. The one with grouting showed higher strength and ductility in failure than that without grouting.

A Study on the Expansion Joint of Concrete Lining and Duct in a Tunnel (터널 콘크리트 라이닝 및 공동구 신축이음 설치방안에 관한 연구)

  • Son, Moorak;Park, Yangheum;Park, Yunjae;Kim, Jaegyoun;Yoon, Jongcheol
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.3
    • /
    • pp.39-50
    • /
    • 2015
  • The installation of the expansion joints in a tunnel concrete lining and duct would minimize the cracking at the location of structural shape and stiffness change, differential settlement, big temperature change, and so on. However, it is difficult to determine the required spacing of the expansion joint in a tunnel concrete lining and duct quantitatively because the spacing is influenced by temperature change, structure construction condition, ground-structure interaction, and etc. Nevertheless, a highway specification (Korea Expressway Corporation, 2012) or a road design manual (Ministry of Land, Transport and Maritime Affairs, 2010) specifies that the expansion joint spacing in a tunnel concrete lining should be installed uniformly smaller than 25 m from the tunnel portals to 50 m inside of a tunnel and elsewhre 20-60 m in a tunnel (because there is no specifcation for a duct it is assumed that a duct follows the specfication of lining). This specification results in several construction and economic problems in relation with a tunnel construction. Accordingly, in order to minimize the problems, this study analyzed both domestic and foreign design standards and specifications. In addition, field test, theoretical and numerical analyses were carried out in relation to the expansion joint in a tunnel lining and duct. The purpose of this study is to reestabilish a criterion for installing the expansion joint in a tunnel concrete lining and duct.

Exterior Wall Formwork System (외벽 거푸집 시스템(구의 아크로리버 현장 사례를 중심으로))

  • 김동진;김욱종;신동호;이도범
    • Magazine of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.21-26
    • /
    • 2002
  • 구의 아크로리버 현장은 서울의 동쪽에 위치한 지하 5층, 지상 37층과 지상 22/26/29층 2개 동의 업무/판매시설 및 공동주택을 신축하는 주상복합형 프로젝트로서 주변에 강변시외버스터미널과 테크노마트가 바로 인접하여 평소 유동인구가 매우 많은 곳에 위치해 있다. (그림 1)은 구의 아크로리버의 조감도이며, 공사개요는 (표 1)과 같다.(중략)

A Study on the Effect of the Shrinkage Strip on Shrinkage and Thermal Change of Concrete in the Underground Parking Structure (공동주택 지하주차장의 건조수축 및 온도영향에 대한 수축대의 효과 연구)

  • 김록배;김욱종;이도범;이운세
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.827-832
    • /
    • 2001
  • Shrinkage during the curing and drying of concrete is unavoidable and results in many cracks. Shrinkage strips reduce effectively shrinkage stresses and minimize shrinkage cracks by being left open for a certain time during construction to allow a significant part of the shrinkage to occur without inducing stresses. This study verifies the effectiveness of shrinkage strips and provides the guide for construction of such strips.

  • PDF

Vibration Analysis Study of Heavy Weight Impact Source in an Apartment Building (공동주택의 중량충격원에 의한 진동해석 연구)

  • Yun Jin Ho;Park Il Sun;Noh Sam-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.191-194
    • /
    • 2005
  • Recently the heavy weight impact noise transmitted slab vibration has been recognized as an important issue. The aim of this study is to find the path of vibration transmission, comparing the numerical analysis with the field test results. Additionally the effect of stiffening beam element under slab, as a method to increase the stiffness of slab, will be shown concerning natural frequencies.

  • PDF

Evaluation of Field Application on the Prediction Method of Early-age Strength of Early Concrete for Construction Work Period Reduction (공기단축 조강콘크리트의 조기강도 예측기술의 현장적용성 평가)

  • Lee, Woong-Jong;Keum, Kyoung-Hun;Lee, Jae-Hyun;Jung, Yang-Hee;Kim, Yong-Ro
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.443-444
    • /
    • 2010
  • In this study, It is confirmed the validity for determination of the form removal time, utilizing prediction expression for early-stage strength which depended on the variation of curing history for early strength concrete which be passible to construction work period reduction, in apartment.

  • PDF

Radar Imaging of Concrete Specimens with Improved Resolution Using Expanded Frequency Bandwidth (주파수 대역 확장을 이용한 콘크리트 시편의 레이더 영상 분해능 향상)

  • 임홍철;이주희
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.13-21
    • /
    • 2002
  • Frequency bandwidth has been combined to determine adequate frequency bandwidth which is necessary for nondestructive testing when using inverse synthetic aperture radar(ISAR). For imaging inside of concrete specimens using radar, the principles of radar and signal processing are discussed. Experimental data obtained from radar measurement of three different concrete specimens at two different frequency bandwidths of 2∼3.4 GHz, 3.4∼5.8 GHz and these two frequencies are combined to obtain improved imagery. A signal processing scheme has been implemented to visualize inside concrete specimens. The influence of frequency bandwidth was analyzed in nondestructive testing by changing frequency bandwidth for concrete specimen.

Numerical Analysis on the Crack Control of Concrete Lining Reinforced by Composite Fibers (복합섬유보강 콘크리트 라이닝 부재의 균열제어를 위한 수치해석적 연구)

  • Yang, Woo-Shik
    • Journal of the Korean Geosynthetics Society
    • /
    • v.9 no.2
    • /
    • pp.41-50
    • /
    • 2010
  • The concrete lining of a tunnel constructed by NATM used to be regarded as facing material which does not support any load from the surrounding ground. But the recent appraisal of the decrepit tunnels revealed that rockbolts and shotcrete deteriorate with time resulting in loss of supporting capability. Consequently, concrete lining has to support part of the load which used to be supported by rockbolts and shotcrete, and thus should be regarded as the final supporting structure in a tunnel. One of the common, and perhaps the most serious problem in concrete lining is the longitudinal cracks taking place at the tunnel crown. The longitudinal cracks, mostly related to the construction procedures, can be developed by many reasons such as the lack of thickness, wrong materials, bad curing environment, and excessive external forces. Many efforts has been made to control and suppress these cracks but efficient and economic way is yet to be found. For efficient crack control in concrete lining, reinforcement by composite fibers, which is the mixture of steel fiber and nylon fiber, is suggested in this study.

  • PDF