• Title/Summary/Keyword: 컴퓨터 방사선

Search Result 431, Processing Time 0.033 seconds

Combined X-ray CT/SPECT System with a Common CZT Detector (CZT검출기를 이용한 CT/SPECT 조합영상시스템)

  • 권수일
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.229-233
    • /
    • 2002
  • We have tested a combined CT/SPECT system with a single CZT detector for x-ray and gamma-ray medical imaging. The size of detector is 10$\times$10$\times$5 ㎣, and the anodes are pixellated as a 4$\times$4 array with a pixel dimension of $1.5\times$1.5 $\textrm{mm}^2$. The cathode was coated with a continuous Au-plated. We have characterized the system performance by scanning a radiographic resolution phantom and the Hoffman Brain phantom. Pulse counting electronics with very short shaping time (50 ㎱) are used to satisfy high photon rates in x-ray imaging, and response linearity up to 3$\times$10$^{5}$ counts per second per detector element is achieved. Energy resolution of 10.4% and 5.3% FWHM at Tc-99m 140 keV peak are obtained for the 50 ㎱ and 2 $mutextrm{s}$ shaping times, respectively. The spatial resolutions of CT and SPECT are about 1mm and 9mm, respectively. Photopeak efficiency of detector systems are 41.0% for 50㎱ and 72.5% for 2 $mutextrm{s}$ shaping time.

  • PDF

Accelerating Medical Image Processing on Integrated GPU Using OpenCL (OpenCL을 이용한 내장형 GPU에서의 의학영상처리 가속화)

  • Kim, Beom-Jun;Shin, Byeong-seok
    • Journal of the Korea Computer Graphics Society
    • /
    • v.23 no.2
    • /
    • pp.1-10
    • /
    • 2017
  • A variety of filters are applied to improve the quality of noise and low resolution medical images. This is necessary to reduce the radiation dose of the patient and to improve the utilization of the conventional spherical imaging equipment. In the conventional method, it is common to perform filtering using the CPU of the PC. However, it is difficult to produce results in real time by applying various calculations and filters to high-resolution human images using only the CPU performance of a PC used in a hospital. In this paper, we analyze the structure and performance of Intel integrated GPU in CPU and propose a method to perform image filtering using OpenCL parallel processing function. By applying complex filters with high computational complexity to medical images, high quality images can be generated in real time.

A Case of Lung Involvement Showing Multiple Lung Cysts in Primary Sjögren's Syndrome (다발성 폐 낭종을 보인 쇼그렌 증후군의 폐 침범 1예)

  • Kim, Ji Yon;Hwang, Hyun Gyu;Choi, Jae Sung;Seo, Ki Hyun;Kim, Yong Hoon;Oh, Mee Hye;Na, Ju Ock
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.3
    • /
    • pp.230-235
    • /
    • 2008
  • We described herein the first case of primary $Sj{\ddot{o}}gren^{\prime}s$ syndrome in Korea which presented with multiple cysts caused by only peribronchiolar lymphocytic infiltration, a rare pulmonary manifestation in $Sj{\ddot{o}}gren^{\prime}s$ syndrome, and was confirmed by surgical lung biopsy. A brief review of the literature has been included.

Implant-supported fixed prosthesis restoration of fully edentulous patient using computer-guided implant surgery and immediate loading: A case report (Computer guided implant surgery와 immediate loading을 활용한 무치악 환자의 전악 임플란트 고정성 보철물 수복 증례)

  • Hyeon-Me Sung;Kyoung-Hee Sul;Sun-Woo Kang;Jung-Han Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.131-139
    • /
    • 2024
  • In a edentulous patient, various methods can be employed for prosthetic treatment using implants, such as implant-supported fixed prostheses, overdentures, hybrid prostheses, and implant assisted removable partial denture. In this case, in a patient with moderate to severe chronic periodontitis requiring full arch extractions, implants were strategically placed using computer-guided surgery. In the maxilla, due to inadequate bone quality and quantity leading to insufficient initial stability, delayed loading was implemented, and interim prosthesis was used during the osseointegration period. In the mandible, stable initial stability was achieved, allowing for immediate loading to reduce patient discomfort. Primary stability is considered the most crucial factor for obtaining immediate loading, so a thorough clinical and radiological evaluation of the remaining alveolar bone quantity and quality must be conducted before surgery.

A Dosimetric Evaluation of Large Pendulous Breast Irradiation in Prone Position (Large Pendulous Breast 환자의 방사선 치료에 있어서 엎드린 자세의 유용성 평가)

  • Hong, Chae-Seon;Ju, Sang-Gyu;Park, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.37-43
    • /
    • 2008
  • Purpose: To evaluate dosimetry results of three different techniques for whole breast irradiation after conservative surgery of large pendulous breast patient. Materials and Methods: Planning computed tomography (CT) scans for three techniques were performed on a GE Hi-speed advantage CT scanner in the supine (SP), supine with breast supporting Device (SD) and prone position on a custom prone mattress (PP). Computed tomography images were acquired at 5 mm thickness. The clinical target volumes (CTV), ipsilateral lung and heart were delineated to evaluate the dose statistic, and all techniques were planned with the tangential photon beams (Pinnacle$^3$, Philips Medical System, USA). The prescribed dose was 50 Gy delivered in 25 fractions. To evaluate the dose coverage for CTV, we analysed percent volume of CTV receiving minimum of 95%, 100%, 105%, and 110% of prescription dose ($V_{95}$, $V_{100}$, $V_{105}$, and $V_{110}$) and minimal dose covering 95% ($D_{95}$) of CTV. The dosimetric comparison for heart and ipsilateral lung was analysed using the minimal dose covering 5% of each organs ($D_5$) and the volume that received >18 Gy for the heart and >20 Gy for the ipsilateral lung. Results: Target volume coverage ($V_{95}$ and $V_{100}$) was not significantly different for all technique. The V105 was lower for PP (1.2% vs. 4.4% for SP, 11.1% for SD). Minimal dose covering 95% ($D_{95}$) of target was 47.5 Gy, 47.7 Gy and 48 Gy for SP, SD and PP. The volume of ipsilateral lung received >20 Gy was 21.7%, 11.6% and 4.9% for SP, SD and PP. The volume of heart received >18 Gy was 17.0%, 16.1% and 9.8% for SP, SD and PP. Conclusion: Prone positioning of patient for large pendulous breast irradiation enables improving dose uniformity with minimal heart and lung doses.

  • PDF

Analysis of disease mechanism of subacute necrotizing lymphadenitis in children (소아 아급성 괴사성 림프절염의 임상적, 방사선학적, 면역조직화학적 소견)

  • Kim, Hyun Jung;Yeom, Jung Suk;Park, Ji Suk;Park, Eun Sil;Seo, Ji Hyun;Lim, Jae Young;Park, Chan Hoo;Woo, Hyang Ok;Cho, Jae Min;Lee, Jeong Hee;Youn, Hee Shang
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.11
    • /
    • pp.1198-1204
    • /
    • 2008
  • Purpose : The cause of subacute necrotizing lymphadenitis, a rare disease in children, has not been completely clarified. This study was aimed to investigate the disease mechanism by examining clinical, radiologic, and immunohistochemical findings in children diagnosed with subacute necrotizing lymphadenitis after an excisional biopsy. Methods : We examined 19 lymph node tissue specimens from 17 children diagnosed with subacute necrotizing lymphadenitis at Gyeongsang National University Hospital from March, 1998 to July, 2006. A retrospective survey of the medical records was performed. CT findings were analyzed. Immunohistochemical staining was done on tissues obtained by excisional biopsy from all patients. Results : The patient's age ranged from 5 to 19 years (average age :11.8 years). The main symptoms included a neck mass (17/19), pain in the mass (6/17), and fever (12/19). The palpable lymph nodes were mostly cervical in location; the maximum diameter, which was measured radiologically, was less than 3 cm in all 10 cases. The masses were pathologically divided into proliferative, necrotic, and xanthomatous types. With immunohistochemical staining the masses were divided into lesion (L), perilesion (PL), and necrosis (N). The CD8 staining was stronger than the CD4 staining for all regions in three types. The CD4 staining intensity was mainly increased in the perilesion, and CD8 was mainly increased in the lesion. Conclusion : We compared the radiologic findings, clinical symptoms, and pathology to help understand the cause of disease in patients with subacute necrotizing lymphadenitis.

Bladder And Rectum Dose Define 3D Treatment Planning for Cervix Cancer Brachtherapy Comparison of Dose-Volume Histograms for Organ Contour and Organ Wall Contour (자궁경부암의 고선량률 근접치료시 장기묘사 방법에 따른 직장과 방광의 선량비교 분석)

  • Kim, Jong-Won;Kim, Dae-Hyun;Choi, Joon-Yong;Won, Yeong-Jin
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.327-333
    • /
    • 2012
  • Purpose: To analyze the correlation between dose volume histograms(DVH) based on organ outer wall contour and organ wall delineation for bladder and rectum, and to compare the doses to these organs with the absorbed doses at the bladder and rectum. Material and methods: Individual CT based brachytherapy treatment planning was performed in 13 patients with cervical cancer as part of a prospective comparative trial. The external contours and the organ walls were delineated for the bladder and rectum in order to compute the corresponding dose volume histograms. The minimum dose in 0.1 $cm^3$, 1 $cm^3$, 2 $cm^3$, 5 $cm^3$, 10 $cm^3$ volumes receiving the highest dose were compared with the absorbed dose at the rectum and bladder reference point. Results: The bladder and rectal doses derived from organ outer wall contour and computed for volumes of 2 $cm^3$, provided a good estimate for the doses computed for the organ wall contour only. This correspondence was no longer true when large volumes were considered. Conclusion: For clinical applications, when volumes smaller than 5 $cm^2$ are considered, the dose-volume histograms computed from external organ contours for the bladder and rectum can be used instead of dose -volume histograms computed for the organ walls only. External organ contours are indeed easier to obtain. The dose at the ICRU rectum reference point provides a good estimate of the rectal dose computed for volumes smaller than 2 $cm^2$ only for a midline position of the rectum. The ICRU bladder reference point provides a good estimate of the dose computed for the bladder wall only in cases of appropriate balloon position.

A Study to Apply the Neural Networks for Improvement of X-Ray Chest Image (흉부 X-Ray 영상개선을 위한 신경망 적용에 관한 연구)

  • Lee, Ju-Won;Lee, Han-Wook;Lee, Jong-Hoe;Shin, Tae-Min;Kim Young-Il;Lee, Gun-Ki
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.1
    • /
    • pp.49-55
    • /
    • 2000
  • Recently, X-ray chest rediography is showing a tendency to take an image of digital radiography so as to diagnose the pathology of chest in a usual. When the radiologist observes the chest image derived from digital radiography system on the monitor, he feels difficult to find out the pathological pattern because the quality of chest radiography is unequal. It takes amount of time to adjust the proper image for diagnosis. Therefore, we propose the method of the chest image equalization using neural networks and provide the compared result with histogram equalization method.

  • PDF

Construction of the TLD Readout System Using the Personal Computer and Its Characteristics (PC를 이용한 TLD 판독장치의 제작과 특성조사)

  • U, Hong;Kang, Hee-Dong;Kim, Do-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.342-349
    • /
    • 1998
  • A multipurpose TLD readout system for radiation dosimetry and thermoluminescence study is constructed and its characteristics are investigated. The thermoluminescent lights are measured by a PM tube and the current-to-frequency converter. TLDs are heated by platinum heater and the heating rate is linearly varied. Measurement of the glow curve and control of the whole system have been done by a personal computer equipped with an interface board. The automatic gain control can be done by the control software. The lower detection limit of the system is about $10\;{\mu}Gy$ and dose response is linear.

  • PDF

Comparison of Image reformation Using Personal Computer with Dentascan Program (CT scan의 다평면 재구성을 하는 Dentascan 프로그램과 개인용 컴퓨터를 이용한 영상재형성과의 비교에 관한 연구)

  • KIM Eun Kyung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.7-16
    • /
    • 1997
  • This study was performed to demonstrate the method of image reformation for dental implants, using a personal computer with inexpensive softwares and to compare the images reformatted using the above method with those using Dentascan software. CT axial slices of 5 mandibles of 5 volunteers from GE Highspeed Advantage(GE Medical systems, U.S.A.) were used. Personal computer used for image reformation was PowerWave 6041120 (Power Computing Co, U.S.A.) and softwares used were Osiris (Univ. Hospital of Geneva, Switzerland) and Import ACCESS V1.H Designed Access Co., U.S.A.) for importing CT images and NIH Image 1.58 (NIH, U.S.A.) for image processing. Seven images were selected among the serial reconstructed cross-sectional images produced by Dentascan(DS group). Seven resliced cross-sectional images at the same position were obtained at the personal computer(PC group). Regression analysis of the measurements of PC group was done against those of DS group. Measurements of the bone height and width at the reformed cross-sectional images using Mac-compatible computer were highly correlated with those using workstation with Dentascan software(height : r²=0.999, p<0.001, width : r²=0.991, p<0.001). So, it is considered that we can use a personal computer with inexpensive softwares for the dental implant planning, instead of the expensive software and workstation.

  • PDF