• Title/Summary/Keyword: 컴퓨터 단층 영상

Search Result 377, Processing Time 0.03 seconds

Bilateral Persistent Sciatic Arteries Complicated with Aneurysmal Dilatation and Thrombotic Occlusion: A Case Report (동맥류와 혈전성 폐색이 동반된 양측 잔류좌골동맥: 증례 보고)

  • Seo Jin Jang;Yoonhee Han;Jae Hyun Kwon
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1517-1522
    • /
    • 2020
  • Persistent sciatic artery (PSA), a rare congenital vascular anomaly, increases susceptibility to aneurysms and accounts for 40-61% of the cases. Here, we describe a case of PSA in a 70-yearold man with a history of alcoholic liver cirrhosis. Bilateral complete PSAs were detected incidentally on computed tomography angiography during evaluation for spontaneous intramuscular bleeding in the thigh due to cirrhosis-related coagulopathy. Selective angiography of the left PSA revealed aneurysmal dilatation and thrombotic occlusion of the PSA, which was partially removed with aspiration thrombectomy. Intramuscular bleeding was succesfully managed with empirical embolization of the deep femoral artery.

Usefulness of Corticomedullary-Phase CT Urography in Patients with Suspected Acute Renal Colic Visiting the Emergency Department (응급실을 방문하는 급성신산통이 의심되는 환자에서 요로조영술 컴퓨터단층촬영의 피질-수질기의 유용성)

  • Seokyoung Lee;Yang Shin Park;Bitna Park;Jongmee Lee;Jae Woong Choi;Kyeong Ah Kim;Chang Hee Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.4
    • /
    • pp.923-933
    • /
    • 2023
  • Purpose To evaluate the sensitivity of corticomedullary-phase imaging for detecting urinary stones in patients with renal colic who visited the emergency department. Materials and Methods This retrospective study included 253 patients with suspected renal colic from two tertiary hospitals in South Korea, who visited the emergency department and underwent CT urography. Two radiologists blinded to the clinical history independently reviewed the corticomedullary-phase images. The sensitivity for identifying urinary stones were evaluated for each reviewer. After the initial evaluation, the images were re-evaluated based on patient history. The sensitivity of re-evaluation were recorded. Results Of 253 patients, 150 (59%) had urinary stones. Among them, significant stones were observed in 138 patients (92%), and obstructive changes on CT in 124 patients (82.7%). For identifying significant urinary stones, the sensitivity was 98.6% (136/138) for both the reviewers. For identifying significant urinary stones with urinary obstruction, the sensitivity was 99.2% (123/124) for reviewer 1, and 100% (124/124) for reviewer 2. The sensitivity for identifying significant stones increased from 98.6% to 100% for reviewer 1, and from 98.6% to 99.3% for reviewer 2 in the re-evaluation session. Conclusion The corticomedullary-phase CT urography was sensitive for diagnosing urolithiasis in patients with acute renal colic who visited the emergency department.

A study on the 3-D standard value of mandible for the diagnosis of facial asymmetry (안면비대칭 진단을 위한 하악골 3차원영상 계측기준치에 관한 연구)

  • Ahn, Jeong-Soon;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.35 no.2 s.109
    • /
    • pp.91-105
    • /
    • 2005
  • For af accurate diagnosis and treatment planning of facial asymmetry, the use of 3-dimensional (3-D) image is indispensable. The purpose of this study was to get standard data for the 3-D analysis of facial asymmetry Computerized tomography (CT) was taken in the 60 normal occlusion individuals (30 male. 30 female) who did not have any apparent facial asymmetry. The acquired 2D CT DICOM data were input on a computer, and the reformatted 3-D images were created using a 3-D image software. Twenty three measurements were established in order to evaluate asymmetry; 15 ;omear measurements (6 for ramus length. 1 for condylar neck length, and 8 for mandibular body length) and 8 angular measurements (4 for gonial angle. 2 for frontal ramal inclination. and 2 for lateral ramal inclination) The right aid left difference of each measurement was calculated and analyzed. It is suggested that the right and left differences of the measurements obtained from the study could be used as references for the diagnosis of facial asymmetric patients.

A Study on the Appropriate Reconstruction of the CBCT Images of Mandibular Canals (CBCT 영상에서 구치부의 하악관 형태에 따른 재구성 방법 연구)

  • Jeong, Cheon-Soo;Mo, Eun-Hee;Lee, Gee-Heun;Han, Beom-Hee;Kim, Seung-Chul;Kim, Jung-Sam;Lim, Cheong-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.369-375
    • /
    • 2011
  • In dental radiography, panoramic views cause distortion and thus may bring about inaccurate results in the process of quantitative analysis. In this connection, there has recently been an increasing use of cone beam computed tomography (CBCT) that is known to provide high-resolution images and positional information. In this study, a dental computed tomography unit, 'DCT-90-P IMPLAGRAPHY (Vatech, Korea)', was applied to 20 patients for 24 seconds respectively, with a tube voltage of 85kVp and a tube current of 7mA. The data of CBCT were three-dimensionally reconstructed by use of a computer program, and were histomorphometrically analyzed. The results showed that the diameter of mandibular canal is less distorted at a certain inclination of the mandibular body. The image tends to seem more distended in proportion to the distance between the subject and film. Also, the image tends to be affected according as it is out of focus. In conclusion, it requires that the image should be reconstructed in light of anatomic position and structure.

Usefulness of MRI 3D Image Reconstruction Techniques for the Diagnosis and Treatment of Femoral Acetabular Impingement Syndrome(Cam type) (대퇴 골두 충돌 증후군(Cam type)의 진단과 치료를 위한 자기공명 3D 영상 재구성 기법의 유용성)

  • Kwak, Yeong-Gon;Kim, Chong-Yeal;Cho, Yeong-Gi
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.313-321
    • /
    • 2015
  • To minimize CT examination for Hip FAI diagnosis and operation plan. also, whether the MRI 3D images can replace Hip Clock face image was evaluated when performing Hip FAI MRI by using additional 3D image. This study analyzed Hip MRI and 3D Hip CT images of 31 patients in this hospital. For the purpose of evaluating the images, one orthopedic surgeon and one radiology specialist reconstructed Clock face, at MR and CT modality, by superior 12 o'clock, labrum front 3 o'clock, and the other side 9 o'clock, centering on Hip joint articular transverse ligament 6 o'clock. Afterwards, by the Likert Scale 5 point scale (independent t-test p<0.005), this study evaluated the check-up of A. retinacular vessel, B. head neck junction at 11 o'clock, A. Epiphyseal line, B. Cam lesion at 12 o'clock, and Cam lesion, Posterior Cam lesion at 1,2,3 and 4 o'clock. As for the verification of reliability among observers, this study verified coincidence by Cohen's weighted Kappa verification. As a result of Likert scale for the purpose of qualitative evaluation about the image, 11 o'clock A. retinacular vessel MR average was $3.69{\pm}1.0$ and CT average was $2.8{\pm}0.78$. B. head neck juncton didn't have a difference between two observers (p <0.416). 12 o'clock A. Epiphyseal line MR average was $3.54{\pm}1.00$ and CT average was $4.5{\pm}0.62$(p<0.000). B. Cam lesion didn't have a difference between two observers (p <0.532). 1,2,3,4 Cam lesion and Posterior Cam lesion were not statistically significant (p <0.656, p <0.658). As a result of weighted Kappa verification, 11 o'clock A.retinacular vessel CT K value was 0.663 and the lowest conformity. As a result of coincidence evaluation on respective item, a very high result was drawn, and two observers showed high reliability.

A comparison of canal centering abilities of four root canal instrument systems using X-ray micro-computed tomography (방사선 미세컴퓨터단층촬영을 이용한 네 종류 file systems의 중심유지능에 관한 비교)

  • Ko, Hye-Suk;You, Heyon-Mee;Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.61-68
    • /
    • 2007
  • The purpose of this study was to compare the centering abilities of four root canal instrument systems and the amounts of dentin removed after root canal shaping using them. The mesial canals of twenty extracted mandibular first molars having $10-20^{\circ}$ curvature were scanned using X-ray micro-computed tomography (XMCT)-scanner before root canals were instrumented. They were divided into four groups (n = 10 per group). In Group 1, root canals were instrumented by the step-back technique with stainless steel K-Flexofile after coronal flaring. The remainders were instrumented by the crown-down technique with Profile (Group 2), ProTaper (Group 3) or K3 system (Group 4). All canals were prepared up to size 25 at the end-point of preparation and scanned again. Scanned images were processed to reconstruct three-dimensional images using three-dimensional image software and the changes of total canal volume were measured. Pre-and post-operative cross-sectional images of 1, 3, 5, and 7 mm from the apical foramen were com pared. For each level, centering ratio were calculated using Adobe Photoshop 6.0 and image software program. ProTaper and K3 systems have a tendency to remove more dentin than the other file systems. In all groups, the lowest value of centering ratio at 3 mm level was observed. And except at 3 mm level, ProTaper system made canals less centered than the other systems (p < 0.05).

New maxillary anterior ridge classification according to ideal implant restorative position determined by CAT (전산화단층영상을 이용한 이상적 임플란트 수복 위치에 따른 상악 전치부 치조제의 새로운 분류)

  • Park, Young-Sang;Cho, Sang-Choon;Kim, Kyoung-Nam;Kim, Kwang-Mahn;Choi, Seong-Ho;Moon, Hong-Seok;Lee, Yong-Keun
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.sup2
    • /
    • pp.385-396
    • /
    • 2007
  • This study proposed a new classification system for maxillary anterior alveolar ridge deformities based on CAT-scan implant simulation as a useful concept in order to more precisely predict treatment outcomes and the necessity for ridge augmentation prior to implant placement. The results indicate that a high number of cases in the maxillary anterior area would require augmentation procedures in order to achieve ideal implant placement and restoration.

Preparation of Gold Coated Liposomes for CT Contrast Medium (CT 조영을 위한 금 코팅 리포솜의 제조)

  • Wee, Tae In;Jeon, Ye Won;Cho, Young Jae;Cho, Sung Keun;Ha, Jeung;Lee, Jeong Won;Cho, Sun Hang;Han, Hee Dong;Shin, Byung Cheol
    • Journal of the Korean Chemical Society
    • /
    • v.57 no.5
    • /
    • pp.634-639
    • /
    • 2013
  • The use of medical imaging has been increased for diagnosis of cancer or vessel disease. Among the medical imaging, computed tomography (CT) is one of the popular methods, however, which should need administration of contrast medium. Therefore, we developed gold coated liposomes (GCL) as a contrast medium. To coat gold on the liposomal surface, positive charged liposomes was prepared and then negative $Au^-$ can coat on the liposomal surface by electronic interaction. The size of GCL was $154.8{\pm}9.2$ nm and surface charge was $27{\pm}3.2$ mV, respectively. The morphology of GCL was confirmed by electron microscopy (SEM) and transmission electron microscopy (TEM). The coating efficiency of gold was 18%. Chemical procedure for gold coating on liposomal surface was not toxic for cell cytotoxicity by MTT assay. Finally, we demonstrated attractive CT image for GCL. Taken together, the GCL would be useful for various vessel related disease as a contrast medium.

Efficient Determination of Iteration Number for Algebraic Reconstruction Technique in CT (CT의 대수적재구성기법에서 효율적인 반복 횟수 결정)

  • Joon-Min, Gil;Kwon Su, Chon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.141-148
    • /
    • 2023
  • The algebraic reconstruction technique is one of the reconstruction methods in CT and shows good image quality against noise-dominant conditions. The number of iteration is one of the key factors determining the execution time for the algebraic reconstruction technique. However, there are some rules for determining the number of iterations that result in more than a few hundred iterations. Thus, the rules are difficult to apply in practice. In this study, we proposed a method to determine the number of iterations for practical applications. The reconstructed image quality shows slow convergence as the number of iterations increases. Image quality 𝜖 < 0.001 was used to determine the optimal number of iteration. The Shepp-Logan head phantom was used to obtain noise-free projection and projections with noise for 360, 720, and 1440 views were obtained using Geant4 Monte Carlo simulation that has the same geometry dimension as a clinic CT system. Images reconstructed by around 10 iterations within the stop condition showed good quality. The method for determining the iteration number is an efficient way of replacing the best image-quality-based method, which brings over a few hundred iterations.

Omental Torsion and Infarction Secondary to Omental Hernia in the Right Inguinal Canal (오른쪽 서혜부 탈장에 의해 이차적으로 발생한 대망의 염전 및 경색)

  • Yu Hyun Lee;Jae Hoon Lim;Heon-Kyun Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.4
    • /
    • pp.1003-1007
    • /
    • 2020
  • Omental torsion secondary to inguinal hernia has rarely been reported as a cause of acute abdominal pain. However, in our case, omental infarction due to prolonged inguinal hernia-associated omental torsion led to the formation of a large omental mass with marginal fibrosis, and the patient presented with chronic abdominal pain. A 74-year-old man presented with complaints of lower abdominal pain for 1 month; subsequently, bilateral inguinal hernias were identified through inguinal ultrasonography. CT scans revealed that the greater omentum was trapped within the right inguinal canal, leading to omental torsion. The greater omentum, distal to the pedicle, appeared as a 30 cm-sized oblong fibrofatty mass in the right lower abdomen and pelvic cavity. Laparoscopic omentectomy with hernia repair was successfully performed.