• Title/Summary/Keyword: 카테터 삽입

Search Result 68, Processing Time 0.033 seconds

Safety and Efficacy of Peripherally Inserted Central Catheters in Terminally Ill Cancer Patients: Single Institute Experience

  • Park, Kwonoh;Lim, Hyoung Gun;Hong, Ji Yeon;Song, Hunho
    • Journal of Hospice and Palliative Care
    • /
    • v.17 no.3
    • /
    • pp.179-184
    • /
    • 2014
  • Purpose: We investigated the safety and efficacy of peripherally inserted central catheters (PICCs) in terminally ill cancer patients. Methods: A retrospective review was conducted on patients who underwent PICC at the hospice-palliative division of KEPCO (Korea Electric Power Corporation) Medical Center between January 2013 and December 2013. All PICCs were inserted by an interventional radiologist. Results: A total of 30 terminally ill cancer patients received the PICC procedure during the study period. Including one patient who had had two PICC insertions during the period, we analyzed a total of 31 episodes of catheterization and 571 PICC days. The median catheter life span was 14.0 days (range, 1~90 days). In 25 cases, catheters were maintained until the intended time (discharge, transfer, or death), while they were removed prematurely in six other cases (19%; 10.5/1000 PICC days). Thus, the catheter maintenance success rate was 81%. Of those six premature PICC removal cases, self-removal due to delirium occurred in four cases (13%; 7.0/1000 PICC days), and catheter-related blood stream infection and thrombosis were reported in one case, each (3%; 1.8/1000 PICC days). Complication cases totaled eight (26%; 14.1/1000 PICC days). The time to complication development ranged from two to 14 days and the median was seven days. There was no PICC complication-related death. Conclusion: Considering characteristics of terminally ill cancer patients, such as a poor general condition, vulnerability to trivial damage, and a limited period of survival, PICC could be a safe intravenous procedure.

Technical and Clinical Considerations for Successful Management of Postoperative Bowel Perforation by Percutaneous Foley Catheter Placement (경피적 폴리 카테터 삽입을 이용하여 수술 후 장 누출을 성공적으로 관리하기 위한 기술적 및 임상적 요인들)

  • So young Cho;Jung Suk Oh;Hae Giu Lee;Byung Gil Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1389-1396
    • /
    • 2020
  • Purpose The aim of this study was to analyze several technical and clinical factors associated with the successful management of postoperative leakage by percutaneous Foley catheter placement. Materials and Methods Thirty-two patients were included in this retrospective study. Postoperative gastrointestinal leakage was diagnosed by computed tomography (CT) and the patients underwent percutaneous Foley catheter placement into the leakage site through Jackson-Pratt tubes or imaging-guided methods. Clinical success was defined as successful Foley catheter removal without symptom recurrence within 1 week and the risk factors for clinical failure were analyzed. Results In all patients, percutaneous Foley catheter placement was successfully achieved without complications. Foley catheter was placed at a median of 10 days (range, 1-68) after the confirmation of leakage on CT. Clinical success was achieved in 26 of the 32 patients (81%). Systemic comorbidity (p < 0.001) and failed oral intake (p = 0.015) were the statistically significant risk factors for clinical failure. Conclusion Percutaneous Foley catheter placement can be considered an effective approach for the management of postoperative bowel leakage. The presence of systemic comorbidity and successful oral diet after Foley catheter placement are significant factors for successful clinical recovery.

Guidelines for Determining Length of Tunneled Dialysis Catheter (터널식 투석관의 길이 결정 가이드라인)

  • Park, Ho-Sung;Kim, Jae-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.241-248
    • /
    • 2022
  • A guideline for determining the optimal catheter length according to the patient's physique during tunnel-type dialysis catheter insertion used in renal failure patients is presented, and the maintenance of the function of the dialysis catheter is evaluated. From October 1, 2015 to February 31, 2016, a total of 110 (male : female = 73 : 37) patients who underwent tunnel-type dialysis catheterization performed at our hospital were treated without using guidelines. The group was divided into A group, and the group treated using the guideline into B group. Results were analyzed statistically using SPSS 20.0. As a result of the dialysis catheter insertion procedure according to the use of guidelines, the function maintenance rate of group A was 81.8%, and the function maintenance rate of group B was 96.3%. In the case of tunnel dialysis catheter procedure, the function maintenance effect was statistically significant in the group treated using the guideline compared to the group not using it (p<0.05). It can be said that it is more effective when information on the patient's underlying disease is reflected in addition to the use of guidelines.

Pain Reduction Effects of Lidocaine Gel for Urethral Catheterization : A Systematic Review and Meta-Analysis (요도 카테터 삽입술에서 리도카인 윤활제의 통증 감소 효과 : 체계적 문헌고찰과 메타분석)

  • Hong, Hyun-Jung;Kim, Ga-Eun;Lee, Ha-Nee;Lee, A-Reum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.438-448
    • /
    • 2017
  • This study was a systematic review and meta-analysis that evaluated the results of research on the pain reduction effects of lidocaine gel for urethral catheterization in adults. A literature search was conducted using seven electronic databases, gray literature and other resources based on the guidelines of Preferred Reporting Items for Systematic review and Meta-Analysis (PRISMA). A Risk of Bias (RoB) tool was applied to assess the quality of selected studies. Data were analyzed using the RevMan 5.3.-program. Sixteen randomized controlled trials involving 1904 adults were included. RoB was not observed in the funnel plot. Overall, lidocaine gel was effective for pain reduction during urethral catheterization (Standard Mean Difference[SMD] -0.96;95% CI: -1.43, -0.49). To explore the cause of heterogeneity (I2=95%, p<.001), subgroup analysis was conducted according to three catheter types (urinary catheter, flexible cystoscopy, and rigid cystoscopy) and the SMDs were -0.88 (95% CI:-1.51, -0.26), -0.31 (95% CI:-0.63, 0.01), and -1.93 (95% CI:-2.88, -0.97), respectively. A significant pain reduction effect was observed regardless of gender in urinary catheterization. However, in rigid cystoscopy, a significant pain reduction effect was observed only in male subjects. Pain reduction effects were observed when 10~11ml lidocaine gel was used during rigid cystoscopy and when lubrication was used during urinary catheterization, irrespective of application time. These findings suggest that lidocaine gel is a useful anesthetic lubricant for urinary catheterization and rigid cystoscopy in male adults.

Insertion Path Extraction of Catheter for Coronary Angiography (관상동맥 조영술을 위한 카테터 삽입 경로 추출)

  • Kim, Sung-Hu;Lee, Ju-Won;Kim, Joo-Ho;Lee, Han-Wook;Jung, Won-Geun;Lee, Gun-Ki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.4
    • /
    • pp.951-956
    • /
    • 2011
  • Coronary angiography technology is usually used for examining or treating coronary artery stenosis. Especially, when a cardiologist inserts catheter into the heart blood vessel, the catheter path detection system is needed because the cardiologist has difficulty in not damaging vessel. Recently, to reduce this difficulty, many searchers have been working for the various image processing technologies, such as vessel edge detection, optimal threshold method, etc. However the results of these searches are showing different performances depend on the contrast and quality of images. Therefore, this study for the coronary angiography suggests a novel algorithm to avoid these problems. The suggested algorithm consists of multi-sampling, interpolation, threshold method, and fault points elimination. To evaluate the performance of the proposed method, we used several angiographic images in experimentation, and we found that the proposed method is effective for detecting the catheter insertion path.

Findings of an Intravenous Catheter Fragment in the Vein Using the 3D Image Reformations of MDCT (정맥내의 IV 카테터 조각의 3D MDCT 재구성 영상)

  • Kweon, Dae-Cheol;Yoo, Beong-Gyu;Yang, Sung-Hwan;Kim, Jeong-Goo
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.167-172
    • /
    • 2006
  • Catheter fragment and embolism are both potentially serious complications associated with the use of an intravenous (IV) catheter for contrast media bolus injection, and may be followed by serious or lethal sequelae. Though catheter fragment is a rare complication of IV catheter insertion, especially in peripheral veins, CT can be used to detect residual fragment. This study demonstrates the utility of MDCT to localize a small, subtle peripheral venous catheter, which can be easily reformatted of MDCT reformations. Various 3D techniques such as MPR and MIP, volume rendering, and shaded-surface displays are currently available for reconstructing MDCT data. Advances in MDCT technology contribute substantially to the detection and accurate localization of smaller IV catheter fragment.

  • PDF

Feasibility and Safety of a Technique Intended to Place the Catheter Tip in the Right Atrium without Abutment Against the Cardiac Wall during Implantation of the Totally Implantable Venous Access Port (완전이식형 정맥 접근 포트 삽입 시 카테터 팁을 심벽에 닿지 않고 우심방 내 위치시키는 방법의 타당성과 안전성)

  • Hyejin Park;Tae-Seok Seo;Myung Gyu Song;Woo Jin Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.161-170
    • /
    • 2024
  • Purpose To assess the safety and feasibility of intentionally positioning the catheter tip in the right atrium (RA) without an abutment during implantation of a totally implantable venous access port (TIVAP). Materials and Methods We enrolled 330 patients who had undergone TIVAP implantation between January and December 2016 and postoperative chest CT. The TIVAP was placed using the single-incision technique to access the axillary vein directly from the incision line. To position the catheter tip in the RA without abutment, blood return was checked before cutting. Catheter length and complications were evaluated by retrospectively reviewing medical images and records. Results All patients achieved successful catheter tip positioning without abutment or dysfunction. The median tip position was 15.3 mm distal to the cavoatrial junction (CAJ) on fluoroscopy and 6 mm distal to the CAJ on CT. Catheter tips migrated a median of 10.4 mm cephalically on CT compared to fluoroscopy. Thromboses were detected in the RA and superior vena cava in one patient each. Conclusion Intentional catheter tip positioning in the RA without abutment is a safe and feasible technique with a low incidence of thrombosis and no observed dysfunction.

Placement of a Subclavian Tunneled Hemodialysis Catheter with the Patient's Arm Raised May Reduce the Risk of Complications: Two Cases Report (쇄골하정맥을 통한 매립혈액투석카테터 삽입시 상지 거상법의 유용성: 2예 보고)

  • Jimin Yoo;Dong Jae Shim;Doyoung Kim;Seung Hwan Baek;Chang Suk Park;Jeong Whee Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.477-482
    • /
    • 2023
  • The subclavian vein is an uncommon route for tunneled hemodialysis catheter (tHDC) placement because of its potency for future dialysis access. However, when favored access routes have been exhausted because of repeated catheterization or limited life expectancy, the subclavian vein can be used for urgent hemodialysis. A subclavian catheterization has a technical problem. The subclavian vein often forms a right angle with the vena cava, and advancing stiff peel-away sheath can cause a vascular injury. However, raising the patient's arm can alter the position of the guidewire and, therefore, change the angle of the vein favorable for tHDC placement. Herein, we report two patients who underwent subclavian catheterization; one experienced an injury to the superior vena cava after undergoing the conventional procedure, whereas the other patient with raised arm during the catheterization procedure had safe catheter placement.

Blood Flow Characteristics due to Catheter Insertion in the Eccentric Stenosed Coronary Artery (편심협착부가 있는 관상동맥내 카테터삽입에 따른 혈액유동특성)

  • Roh Hyung-Woon;Suh Sang-Ho;Kwon Hyuk-Moon;Lee Byung-Kwon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.707-708
    • /
    • 2002
  • Catheters are used to measure translesional pressure gradients in the stenosed coronary arteries. Catheter insertions during coronary angioplasty cause flow obstructions. A narrowed flow cross section with catheter present effectively introduced a tighter stenosis than the enlarged residual stenoses after balloon angiplasty. In general, the form of stenoses are no uniform. Sometimes, these are occurred the irregularly eccentricity If the analyses are conducted for uniform stenosed artery, the results will be underestimated. Thus, in this study, three dimensional computer simulations are conducted to investigate the flow blockage effects due to the catheter insertion during the coronary angioplasty. The results for the eccentric stenosed artery are compared with those of the concentric stenosed artery.

  • PDF