• Title/Summary/Keyword: 침실

Search Result 132, Processing Time 0.032 seconds

The Amount of House Mite Allergens & Dusts According to Environmental Factors of Patients With Allergic Rhinitis (알레르기성비염 환자 침실의 환경적 특성에 따른 집먼지 진드기 항원량과 먼지량)

  • Moon Jung Soon;Choi Soon Ock
    • Journal of Korean Public Health Nursing
    • /
    • v.10 no.2
    • /
    • pp.51-60
    • /
    • 1996
  • This study was conducted to provide basic knowledges of effective environmental control of patients with allergic rhinitis. From July to October 1995, 58 dust samples Were drawn from the bedrooms of patients with allergic rhinitis who were registerd at an allergy clinic of a hospital. Those samples were examined for the amount of house mite allergens & dusts. The data were analysed by using ANOVA and Pearson correiation coefficients. The results were as follows : 1. As for the amount of house mite allergens in terms of environmental factors, the amount of house mite allergens of using washing water temperature of bedding above than $55^{\circ}C$ was significantly lower than that of below $54^{\circ}C$. Other environmental factors such as type of house, area of bed room floor, bed in bedroom, bedroom cleaning by vacuum cleaner, days after bedding washing, relative humidity of bedroom were relate to the amount of house mite allergens. 2. As for the amount of dusts in terms of environmental factors, the amount of dusts of days of days after bedding washing more than 15 days was significantly lower than thant of less than 15days. Other environmental factors such as type of house, area of bedroom floor, bed in bedroom, bedroom cleaning by vacuum cleaner, was hing water taemperature of bedding, relative humidity of bedroom were not relate to the amount of dusts. 3. There was a significant positive correlation between the amount of house mite allergens and the amount of dusts. It may be conclusively said. the amount of dusts and house mite allergens were closely associated with the washing temperature and days after washing of bedding. Hence. intensive instruction for the methods of bedding washing was needs of the patients with allergic rhinitis.

  • PDF

Improvement of Sleep Quality Using Color Histogram (컬러 히스토그램을 활용한 수면의 질 향상)

  • Shin, Seong-Yoon;Shin, Kwang-Seong;Rhee, Yamg-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.6
    • /
    • pp.1283-1288
    • /
    • 2011
  • In this paper we collect data concerning sleep environments in a bedroom and analyze the relationship between the collected condition data and sleep. In addition, this paper detects scene changes from the subjects in a sleeping state and presents the physical conditions, reactions during sleep, and physical sensations and stimuli. To detect scene changes in image sequences, we used color histogram for the difference between the preceding frame and the current frame. In addition, to extract the tossing and turning for different situations, the subjects were instructed to enter the level of fatigue, the level of drinking, and the level of stomach emptiness. For the sleep experiment system, we used the H-MOTE2420 Sensor composed of temperature, humidity, and light sensors. This paper is intended to provide the best sleep environment that enhances sleep quality, thus inducing people today to get regular and comfortable sleep.

Enhancement of Sleep Environment Using Sensor (센서를 이용한 수면환경 개선)

  • Shin, Seong-Yoon;Shin, Kwang-Seong;Rhee, Yang-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.11
    • /
    • pp.2485-2490
    • /
    • 2010
  • In this paper, gather the sleep environment data of bedroom to sleeping and analyze the relationship between the obtained conditional data and the sleep. Based on this, system provide the optimal sleep environment of individual person by extracting the simulation model. The experiments of system was using H-MOTE2420 sensor composed of temperature/humidity sensor and ambient light sensors. We use difference image method in motion extraction from video for extraction of tossing and turning. In addition, it was entered such as ratio of fatigue, ratio of drinking, ratio of empty stomach as the information of weight can affect to sleep. Resultingly of experience, we can extract the optimal sleep environment. From now on, we will try to enhance to help to lead more pleasant daily life providing proper indoor environment changes depending on the situation even a partial of organic living environments such as eating and work as well as special sleep circumstances.

Effect of Ondol on physiological Responses during Sleep (I) -On the focus of Bedclimate in Autumn and Winter- (온돌환경이 수면시의 생리반응에 미치는 영향(제1보) -가을, 겨울철 수면시 침실내 온열환경과 침상기후-)

  • Lee, Sun-Won;Gwon, Su-Ae;Choe, Jeong-Hwa
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.4
    • /
    • pp.697-706
    • /
    • 1996
  • The actual conditions of bed climate are investigated depending on the regions and housing styles used on ondol in autumn and winter. Sixty healthy men and women (30 of them live in apartmrnt and 30 of them live in detached house, 20 of them live in Wonju, 20 of them live in Wonju, 20 of them live in Cheongju and 20 of them live in Pusan) The results are as follows: 1) No significant differences was shown between the seasons of bedclothes thickness. 2) In the autumn, the temperature and humidity of bedroom, on the mattress, inside the bedquilt, and inside the sleep-wear were higher than those in the winter. The temperature of ondol floor and under the mattress in winter were higher than those in the autumn. 3) The differences of the temperature and humidity of bedroom, the bed climate, and the clothing microclimate were significant by the regions and housing styles in both seasons. In both seasons, the temperature of bedroom, on the mattress, inside sleep-wear in the apartment were higher than those in the detached house. 4) The differences of subjective sensation on the bedroom conditions were not significant by the sextons, the regions, and the housing styles. Most subjects perceived that the conditions of bedroom were somehow hot and dry, but comfortable.

  • PDF

A Study on the Characteristics of the Floor Plan in Luxurious Row-Houses (고급연립주택의 평면구성 특성에 관한 연구)

  • 라윤주;오혜경
    • Archives of design research
    • /
    • v.14 no.4
    • /
    • pp.209-216
    • /
    • 2001
  • The purpose of this study was to find out the characteristics of the floor plans of luxurious row-houses. The examined objects were 135 floor plans with the individual exclusive space of 50 pyung or more which collected from the solicitations for sale or the magazines of architecture, housing, or interiors. The major findings were summarized as follows: First, it is revealed that as the floor size become bigger, the appropriate additional spaces such as second family room, lounge hobbyroom and Atelier are formed instead of increasing room size. Second, it is revealed that the L- DK type was the most common in LDK system. Third, it is revealed that the master's zone composed generalized layout of 4 sections such as bedroom, sittingroom, bathroom, dressingroom. Fourth, it is revealed that the multifunctional room exist as a individual space located next to the kitchen. It used to be a post of rear balcony.

  • PDF

Comparison of Five Pollutant Levels between Inside and Outside Homes (主要 汚染物質에 대한 家庭에서의 室內外 濃度比較)

  • 金潤信
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.3 no.2
    • /
    • pp.27-32
    • /
    • 1987
  • As part of an air pollution epidemiological study of asthmatics residing in the Houston area, an air monitoring system provided data on the indoor and outdoor measurements of major pollutant gases sampled at selected residences during May ~ October 1981. Continuously monitored pollutant gases included sulfur dioxide ($SO_2$), nitrogen dioxide($NO_2$), nitric oxide(NO), carbon monoxide(CO), and ozone($O_3$). Outdoor levels for each pollutant were compared with their indoor levels(bedroom, kitchen, living room). Mean concentrations of each pollutant in the kitchen, and living room exceeded the mean levels outside except for ozone, while average bedroom levels for all gases except for $O_3$ and $NO_2$ were found higher than the corresponding outside levels. Indoor/ outdoor ratios for $SO_2$, NO, and CO were 1.8 ~ 2.7 times the outdoor levels, but indoor/ outdoor ratios for $NO_2$ and $O_3$ were 0.99 and 0.06, respectively. The impact of several important household characteristics (type of cooking fuel and cigarette smoking) on the indoor levels for these gases is evaluated.

  • PDF

Enhancement of Sleep Environment Using Sensor and User Information (센서와 사용자 정보를 이용한 수면 환경 개선)

  • Shin, Seong-Yoon;Rhee, Yang-Won
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.1
    • /
    • pp.47-52
    • /
    • 2011
  • This paper collect sleep environment data of bedroom to sleeping, and analyzing the relationship between conditions with obtained data and sleep. We provide the optimal sleep environment of individual by extracting the simulation model based on it. The experiments was using temperature/humidity sensor(SHT11) and ambient light sensors(GL5507). For extraction of tossing and turning, we use difference image method in motion extraction from video. In addition, the information of weight can affect to sleep, it was entered such as ratio of fatigue, drinking, empty stomach. As a result, we are able to extract the optimal sleep environment. The future, we will try to improve to help to lead more pleasant daily life providing proper indoor environment changes depending on the situation even a partial of organic ubiquitous living environments such as eating, work ete. as well as certain sleep circumstances.

A Study on Space Requirement and Planning for Various Size of Apartments, Recently Built in Metropolitan Area (최근 입주된 수도권 아파트 거주자를 대상으로 본 규모별 실 구성 요구 분석)

  • Oh, Hye-Kyung;Ham, Min-Jung
    • Journal of the Korean housing association
    • /
    • v.19 no.5
    • /
    • pp.19-27
    • /
    • 2008
  • The purpose of this study was to suggest optimum guidelines apartment rooms by conducing survey among residence whose apartment floor size is between $66-198m^2$ and whose apartment is less than 3 years old. The effective numbers of survey questionnaire turned in was 226 and the survey analysis has been made by using of SPSS WIN 12.0. The results and conclusion of the studies are as follows; (1) $66{\sim}98m^2$ : The recommended numbers of bedroom is 2 and 3. The size of maser bedroom needs to be decreased whereas the size of living room be increased. (2) $99-131m^2$: The recommended numbers of bedroom is 3 and 4. The size of maser bedroom and maser bathroom needs to be decreased whereas the size of living room, 2nd bedroom, kitchen and dining room needs to be increased. (3) $132-164m^2$: The recommended numbers of bedroom is 3 and 4. The size of maser bedroom and bathroom needs to be decreased whereas the size of dress room, kitchen and dining room, and 2nd bedroom needs to be increased. (4) $165-197m^2$: The recommended numbers of bedroom is 3 and 4. The size of maser bedroom and maser bathroom needs to be decreased and the size of dressroom and kitchen /dinning room needs to be increased. (5) $198m^2$ and above: the recommended numbers of bedroom is 3,4 and 5. The size of dressroom needs to be increased. It is revealed that the number of bedroom doesn't need to be increased as the size of apartment is increased. Larger space is required for the public space for the family and dressroom. And smaller space is required for the maser bedroom and master bathroom.

A Comparative Study on The Barrier Free Dwelling Guidelines of Domestic and Foreign Countries -Focused on Entrance, Bedroom and living room (무장애 주택설계에 관한 국내외 국가표준의 비교 연구 -현관, 침실, 거실을 중심으로)

  • Lee, Ho Sung;Choi, Chan-Hwan;Lee, Teuk-Koo
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.16 no.1
    • /
    • pp.65-75
    • /
    • 2010
  • This is a comparative study mainly on foreign countries' domestic standards and laws on barrier free housing construction that can be applied to the dwelling of elderly friendly apartment housing. Eight countries - the United States, Germany, Canada, Switzerland, the United Kingdom, Australia, Japan, and China - were reviewed as foreign cases. The analyzed subjects were design standards only for the disabled and the aged. To compare barrier-free guides of the eight countries, each barrier-free guide on three space units (entrance, bedroom, living room) was divided into 11 design items and 36 design factors. The comparative analysis on foreign cases was based on the design guide according to Korea's KS P 1509 (principle and recommendation for designing dimension of dwelling in consideration of the elderly). Some factors -if with dimensions- were compared by means of the skewness of distribution. In the analysis result, there were not only common standards for the nine countries such as a dimension of the space for wheelchair movement but also different standards such as heights of outlets and horizontal lengths of bathtub grab bars. The detailed analysis shows that it is urgently necessary to prepare new domestic national design standards for 8 factors that foreign countries already have. It is also needed to immediately prepare dimension standards for the design factors, which have no detailed dimensions but only national guides, in consideration for anthropometric dimension.

A study on Daylighting inducement within bedroom of Elderly care facility by light shelf attaching method for Therapeutic environment - By Dynamic Daylight Simulation Using Weather Data - (치유환경을 위한 광선반 부착방법에 따른 노인요양시설 침실 내 자연채광 유입 환경 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Cho, Ju-Young;Lee, Ki-Ho;Yun, Young-Il;Lee, Hyo-Won
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.71-79
    • /
    • 2011
  • There are high recognitions on the importance of comforts in Elderly living environment, but the circumstance is that studies on seniors facility space itself are approached only in planning level, and studies on lighting environment which is significantly associated with the comfort in the indoor environment of seniors where they actually spend the majority of their time are not that active. This study was intended to deduce cozy bedroom environment to which existing elderly care facility can be improved by using light shelf the lighting system with the advantage of being able to serve both as building sun visor and lighting window simultaneously in order to analyze the interior environment of bedroom space of elderly care facility the indoor space where the aged spend the majority of their life and examine the directions for the improvement of existing building lighting system through remodeling and renovation. In this study, lighting performance analysis was done in a way that the windows of the bedroom unit in existing facility were set in southbound direction based on two standard types and were put under initial simulation with the use of Autodesk Revit 2011, and after the simulation results were converted to Green Building Studio gbXML file to be used in ECOTECT, Daylight Autonomy a dynamic simulation and static natural lighting simulation the existing method of calculating daylight factors were deduced through Ecotect Analysis 2011. In conclusion, exiting standard model was found in such a condition that the daylight factors for both type A and type B were above 5% the proper standard value, and required improvement. In case light shelf the natural lighting system was attached, the daylight factor was improved to proper standard value for type A, and also was improved above existing facility for type B.