• Title/Summary/Keyword: 치과기공용 연마기

Search Result 7, Processing Time 0.023 seconds

Prevention of Candida albicans infection in dental polishing lathe by chlorhexidine (클로르헥시딘을 이용한 치과기공용 연마기 캔디다균의 감염방지)

  • Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.274-279
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate the transmission of candida in denture by dental polishing lathe. Materials and Methods: Maxillary complete dentures made from the same model were infected with Candida albicans. Polishing wheels were keep in various chlorhexidine solution and distilled water for an hour. The infected dentures were polished by prepared dental polishing lathe with sterile pumice and distilled water. And then sterile maxillary complete dentures were polished with same method. Polishing surface was wiped with a cotton swab and the sample was regrown for checking Candida albicans. Results: All polishing wheel with chlorhexidine resist fungal infection. But the polishing wheel with distilled water is infected with Candida albicans. Conclusion: A chlorhexidine is highly efficient in fungal infection prevention on dental polishing lathe.

Study of transmission of Candida albicans in denture by dental polishing lathe (의치에서 치과기공용 연마기를 통한 캔디다균의 전염성에 대한 연구)

  • Lee, Gi-Ho;Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.3
    • /
    • pp.199-205
    • /
    • 2014
  • Purpose: The purpose of this study was to evaluate the transmission of candida in denture by dental polishing lathe. Materials and Methods: Maxillary complete dentures made from the same model were infected with Candida albicans. The infected dentures were polished by dental polishing lathe with sterile pumice and distilled water. And then sterile maxillary complete dentures were polished with same method. Polishing surface was wiped with a cotton swab and the sample was checked for Candida albicans. The polishing wheel at room temperature was checked for Candida albicans every 24 hours for 3 days. Results: A considerable number of Candida was found on the polished sterile dentures. And the Candida albicans in polishing wheel was detected at up to two days. Conclusion: An anti-infection measure is urgently needed when dental polishing lathe is used for denture polishing, because of the possibility of fungal infection.

Surface roughness and $Candida$ $albicans$ adhesion to flexible denture base according to various polishing methods (연마방법에 따른 탄성의치의 표면거칠기와 $Candida$ $albicans$의 부착율 변화)

  • Oh, Ju-Won;Seo, Jae-Min;Ahn, Seung-Keun;Park, Ju-Mi;Kang, Cheol-Kyun;Song, Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.106-111
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the effect of 3 chairside polishing methods and laboratory polishing methods on surface roughness and $C.$ $albicans$ adhesion of polyamide denture base. Materials and methods: Using contact profilometer, the surface of polyamide specimens ($25{\times}15{\times}2mm$) was studied after conventional polishing without finishing and after chiarside polishing with 2 chiarside polishing kits and chairside-pumice polishing following finishing with tungsten carbide bur. To evaluate the adhesion of $C.$ $albicans$, $C.$ $albicans$ suspension was overlayed on the test specimen. And the specimens were incubated for 2 hours. Imprint culture method was achieved and counted the colony on the agar plate. Polished polyamide were evaluated using a scanning electron microscope. The statistics were conducted using one-way ANOVA and in case of difference, Scheffe test and Tamhane's T2 test were used. Results: Surface roughness (Ra) of surfaces polished with 2 chairside polishing kits had higher than conventional polishing and pumice polishing. The highest roughness value was $0.32{\pm}0.10{\mu}m$, and the lowest was $0.02{\pm}0.00{\mu}m$. The adhesion of $C.$ $albicans$ on the specimens polished with chairside polishing group and pumice polishing group were increased than conventional polishing group ($P$<.01). Conclusion: Conventional laboratory polishing was found to produce the smoothest surface and the lowest adhesion of $C.$ $albicans$. Two groups polished with Chairside polishing kits were similar with respect to surface roughness. Surface of the specimen polished with pumice is significantly smoother than 2 chairside polishing groups, but the result of $C.$ $albicans$ adhesion is that group polished with pumice was similar with 2 chairside polishing groups ($P$>.01).

Observations of surface roughness of Co-Cr alloys according to grinding time of dental barrel finishing (치과용 바렐연마기의 연마시간에 따른 Co-Cr 합금의 표면거칠기 관찰)

  • Ko, Hyeon-Jeong;Park, Yu-Jin;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.43 no.3
    • /
    • pp.93-98
    • /
    • 2021
  • Purpose: The aim of this study was to observe the surface roughness and surface topography of cobalt-chrome (Co-Cr) alloys with grinding time in dental barrel finishing. Methods: This study involved two types of Co-Cr alloys. Specimens were manufactured with the dimensions 10×10×2 mm. Each specimen was cast according to the manufacturer's instructions. The cast alloys were polished for 35 minutes at intervals of five minutes in an automatic barrel finishing. Specimens were imaged with a three-dimensional optical microscope to measure surface roughness. Results: BC specimens and GM specimens had the highest roughness (Ra) values in the ungrained control group, and the lowest Ra values were measured 20 minutes after grinding. Conclusion: The best conditions for grinding Co-Cr alloy using a dental barrel finishing were a weight ratio of polishing media, water, and compound of 150 g:200 g:5 g, and a rotation speed of 450 rpm. Grinding time to obtain appropriate surface roughness should be limited to 15 to 30 minutes.

Observation of surface roughness on three types of resin based on grinding time of dental automatic barrel finishing (치과용 자동바렐연마기의 연마시간에 따른 3종 레진의 표면거칠기 관찰)

  • Jung, An-Na;Ko, Hyeon-Jeong;Park, Yu-Jin
    • Journal of Technologic Dentistry
    • /
    • v.43 no.2
    • /
    • pp.56-61
    • /
    • 2021
  • Purpose: This study aimed to produce resin prosthetics using a dental automatic barrel finishing. Surface roughness and surface topography of resins were observed according to the grinding time of the dental automatic barrel finishing. Methods: This study was performed with thermopolymer, autopolymer, and photopolymer resins. The dimensions of the specimen were 10×10×2 mm. Each specimen was polymerized according to the manufacturer's instructions. The polymerized resin was honed for 30 minutes at 5-min intervals in a dental automatic barrel finishing. The specimen was observed using a three-dimensional (3D) optical microscope, and the surface roughness was measured. Results: After the polishing with the dental automatic barrel finishing, the heat-cured (HC) specimen showed the highest and lowest values of Ra after 10 and 15 minutes, respectively. The self-cured (SC) specimen showed the highest and lowest values of Ra after 10 and 25 minutes, respectively. Finally, the 3D specimen showed the highest and lowest values of Ra after 5 and 20 minutes, respectively. Conclusion: After measuring the surface roughness of the three types of resins according to the grinding time of the dental automatic barrel finishing, the lowest Ra values for the HC, SC, and 3D specimens were measured after 15, 25, and 20 minutes, respectively. Therefore, we concluded that a limit on the grinding time of the resin using a dental automatic barrel finishing is needed.

Review on factors affecting the optical properties of dental zirconia (치과용 지르코니아의 광학적 성질에 영향을 미치는 요소에 대한 문헌고찰)

  • Park, Chan-Ho;Ko, Kyung-Ho;Park, Chan-Jin;Cho, Lee-Ra;Huh, Yoon-Hyuk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.177-185
    • /
    • 2021
  • Clinical applications of translucent zirconia as well as traditional zirconia (3 mol% yttria stabilized tetragonal zirconia polycrystal, 3Y-TZP) are increasing. For this reason, studies on factors affecting the optical properties of dental zirconia have been continuously reported. The optical effect of dental zirconia may vary depending on the yttria content, the thickness of the prosthesis, the sintering process, polishing, glazing and cementation in laboratory and clinical procedures. Increasing the yttria concentration can reduce the masking effect. Translucency decreases as the thickness of the restoration increases, but the required thickness may vary depending on the properties of the zirconia block. The high-speed sintering method can shorten the manufacturing time, but in some cases, the translucency of the prosthesis may decrease. In addition, the optical properties can be affected by the surface roughness of zirconia and the polishing process. The use of an appropriate colored cement can help with the masking effect of zirconia and can be useful for color matching for more esthetic results.

Surface Characteristics of Dental Casting Palladium Alloy for Replacement of Gold Alloy (금대체를 위한 치과주조용 파라듐 합금의 표면특성)

  • Park, Seon-Yeong;Hwang, In-Jo;Yu, Ji-Min;Park, Min-Gyu;Im, Sang-Gyu;Bae, Ho-Seong;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.196-196
    • /
    • 2016
  • 치과나 기공소로부터 높은 원가로 인한 재료선택에 어려움을 겪고 있어 귀금속 금합금의 물성을 가질 수 있도록 하면서 가격급등으로 인한 문제 해결하기 위한 비귀금속 합금으로 대체가 필요하기에 이에 따른 연구가 이루어져 국산 제품의 상품화를 위해 파라듐을 이용하여 적합한 새로운 합금을 개발하는 것이 필요하다. 치과용 골드합금은 미국치과의사 협회의 구정에 의하면 1형부터 4형까지 분류하고 있으며 3형에 해당하는 강도와 기계적인 특성을 갖도록 파라듐으로 대체하는 연구가 진행중이거나 시판되고 있다. 따라서 본 연구에서는 2형, 3형 및 4형을 대체가능하도록 팔라듐을 기반으로 한 새로운 합금을 설계하고 합금의 성분원 소인 Au(1~5), Pd(20~25), Ag(70~75), In(1.5) 및 Zn(2)등으로 조성을 변화시켜 측량 후 합금을 제조하기 위하여 아르곤 분위기하의 진공아크용해로를 이용하여 용해하였다. 정량된 금속을 진공아크 용해로에 장입하고 용해는 균질한 합금이 되도록 최소한 6회 이상 용융을 실시하며 합금성분의 손실이 발행하지 않도록 보정을 하였다. 합금의 미세조직 관찰을 위하여 샘플을 고속 다이아몬드 정밀 절단기(Acculom-5, STRUERS, Denmark)를 이용하여 절단한 후 2000 grit의 Sic 연마지에서 단계적으로 $0.3{\mu}m$ 알루미나 분말까지 연마한 후 초음파 세척을 하였다. 준비한 시편은 KCN과 $(NH_4)_2S_2O_8$을 1:1로 혼합한 부식액으로 에칭한 후 OM과 SEM을 이용하여 조직을 관찰하였으며 각 샘플의 성분변화는 EDS 분석을 통해 확인하고 결정구조는 XRD를 사용하여 분석하였다. 경도시험은 비커스경도시험기를 이용하여 5kg의 하중을 30초간 작동시켜 압흔을 연결된 micron으로 평균값을 측정하였다. 각 시편의 부식거동은 POTENTIOSTAT(Model PARSTAT 2273, EG&G, USA)을 이용하여 구강 내환경화 유사한 $36.5{\pm}1^{\circ}C$의 0.9% NaCl에서 실시하였다. 인가전위는 -1500mV에서 1000mV까지 1.67 mV/min의 주사속도로 인가하여 시험을 수행하였으며 분극곡선으로부터 부식전위와 부식전류밀도 및 부동태영역의 전류밀도로 금속의 용출거동을 조사하였으며 부식이 끝난 시편은 FE-SEM과 EDS를 사용하여 조사하였다. 기계적인 특성은 Pd-Ag에 3wt%의 Au를 첨가한 합금이 Pd-Ag에 1.5wt%합금을 첨가한 경우에 비하여 기계적인 특성이 증가하고 내식성이 크게 증가하였다. 이들 합금에 Cu를 11wt%를 첨가한 경우는 비커스경도가 200이상으로 높게 나타났지만 내식성이 크게 감소하였다.

  • PDF