• Title/Summary/Keyword: 측정학

Search Result 18,851, Processing Time 0.039 seconds

Comparison of Gap Pressure in Opening Wedge High Tibial Osteotomy versus Compressive Strength of Allogenous Wedge Bone Blocks (경골 근위부 개방 절골술 시 개방부 압력과 동종 쐐기 골편의 최대압축하중 비교)

  • Yoon, Kyoung Ho;Kim, Jung Suk;Kwon, Yoo Beom;Kim, Eung Ju;Lee, Myeong-Kyu;Kim, Sang-Gyun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.2
    • /
    • pp.127-134
    • /
    • 2020
  • Purpose: The aims of this study were (1) to investigate the relationship between the characteristics of allogenic bone block and the compressive strength of an allogenic bone block measured by biomechanical experiments, and (2) to compare the maximum pressure load of allogenic bone block with the gap pressure measured at the high tibial opening osteotomy. Materials and Methods: Ten patients who provided informed consent for gap pressure measurements during opening wedge high tibial osteotomy (OWHTO) were included. The gap pressures were measured at 1 mm intervals while opening the osteotomy site from 8 mm to 14 mm. Seventeen U-shaped allogenous wedge bone blocks were made from the femur, tibia, and humerus. The height, width, cross-sectional area, and cortex thickness of the bone blocks were measured, along with the maximum compressive load just before breakage. The relationship between these characteristics and the maximum pressure load of the bone blocks was evaluated. The gap pressures measured in OWHTO were compared with the maximum pressure loads of the allogenous wedge bone blocks to evaluate the possibility of inserting allogenous wedge bone blocks into the osteotomy site without a distractor in OWHTO. Results: The OWHTO gap pressure increased with increasing osteotomy site opening. The mean gap pressure, which occurred at a 14-mm opening, was 282±93 N; the maximum pressure was 427 N. The maximum pressure load of the allografts was 13,379±6,469 N (minimum, 5,868; maximum, 29,130 N) and was correlated significantly with the cortical bone thickness (correlation coefficient=0.693, p=0.002) and cross-sectional area (correlation coefficient=0.826, p<0.001). Depending on the sterilization method, the maximum pressure loads for the bone blocks were 13,406±5,928 N for freeze-dried and 13,348±7,449 N for fresh frozen. The maximum compressive load of the allogenous wedge bone blocks was 13.7-times greater than that in OWHTO opened to 14 mm (5,868 N vs. 427 N). Conclusion: The compressive strength of allogenous wedge bone blocks was sufficiently greater than the gap pressure in OWHTO. Therefore, allogenous wedge bone blocks can be inserted safely into the osteotomy site without a distractor.

제약폐수 활성슬러지 공정에서 슬러지의 생물학적 활성 측정

  • Mun, Sun-Sik;Lee, Sang-Hun;Choe, Gwang-Geun;Lee, Sang-Hun;Mun, Hong-Man;Lee, Jin-Won
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.533-536
    • /
    • 2001
  • In this study, biological activity in activated sludge process for pharmaceutical wastewater was analyzed by using respirometer. For various amounts of BOD loadings. oxygen uptake rate was measured and kinetic paramelers were evaluated. By repetition of experiments, optimal operating conditions (eg. MLSS. BOD loadings. oxygen concentration, etc) were decided for the enhancement of activated sludge process.

  • PDF

Observation of Vertical Profiles of Ozone in Northern-part of Seoul Metropolitan area (서울시 북부지역의 오존 연직분포 측정)

  • 이종범;장명도;남창진;김민영;이민환;여인학
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.160-161
    • /
    • 2000
  • 오존농도는 낮동안 일출이 시작되면서 광화학반응을 통하여 생성되고 일몰 후 점차 감소되어 야간에는 오존농도가 점차 파괴된다. 역전층 상부의 오존농도는 오존의 저수지 역할을 하여 연직적인 오존농도 분포에 영향을 미친다. 따라서 서울시 오존의 생성 및 소멸에 관련된 정확한 원인을 밝히는 데에는 혼합층고도 및 역전층의 발달과정에 따른 오존농도의 연직분포를 고찰하여 오존농도의 거동을 시ㆍ공간적으로 파악할 필요가 있다. 특히 서울시에서 방학동 주변지역의 오존 농도는 해마다 높게 측정되고 있는데, 이 지역에 대한 자세한 연구가 필요하다. 본 연구에서는 오존농도 연직분포와 기상측정을 하였다. (중략)

  • PDF

압입속도의 변화에 따른 탄성계수와 경도의 오차 연구

  • Lee, Gyu-Yeong;Lee, Chan-Bin;Kim, Su-In;Lee, Chang-U
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.182-182
    • /
    • 2010
  • 나노 소재의 물성을 측정하기 위하여 대부분의 연구 구룹에서는 크게 두 가지 분석 기법인 분광학을 이용한 분석과 나노트라이볼로지를 이용한 분석을 사용하고 있다. 분광학을 이용한 분석에는 NMR, IR, Raman, SEM, TEM 등이 대표적이라 할 수 있고, 나노트라이볼로지를 이용한 분석에는 AFM, EFM, KFM, Nano-indenter 등의 탐침을 이용한 측정 기법이 대표적이다. Nano-indenter는 물질의 탄성 및 경도를 측정 할 수 있으며 이를 통해 물질의 특성을 연구하는데에 사용된다. 그러나 이런 Nano-indenter의 압입 실험에서는 그 결과값이 압입 조건 등의 통제변수의 함수가 될 것이다. 이를 확인하고 변화값의 parameter를 추출하기 위하여 본 실험에서는 이런 압입 조건 중 Load - Hold - Unload force의 속도 및 시간을 변화시켜 물질의 탄성계수와 경도가 어떻게 변하는지에 대한 역학관계를 연구하였다.

  • PDF

History of Evaluation of sound and noise in passenger cars (승용차의 내부소음평가에 대한 연구사고찰)

  • Schick, August
    • Science of Emotion and Sensibility
    • /
    • v.1 no.2
    • /
    • pp.133-147
    • /
    • 1998
  • 이 글은 영구의 자동차내부 소음연구와 보버르트(Bobbert)의 첫 번재 독일어로 쓰인 연구를 다루고 있다. 승용차내부소음은 높은 적외파음향(infra sound)으로 특징지어 진다. 그런 까닭으로 그러한 종류의 소음을 A-평가계측(A-rated measurement)으로 그 영향을 파알하는 것은 한계가 있다. 자동차음향공학은 특히 인공청각(artificial head)기술의 발전, 소리의 합성적 제조 및 다양한 자동차 내부 음색(timbre)에 대한 일본연구가들 (하쉬모토, 쿠와노, 남바)에 의해 상당산 성취를 경험하였다. 위의 연구들은 무엇보다도 의미분별기법(Semantic Differentials)과 다차원측정방법(Multidimen-sional Scaling)을 사용하고 있다. 그러한 기법의 사용은 심리측정방법을 심리음향학(Psycho-acoustics), 특히 츠뷔커학파(Zwicker school)의 심리음향학 방법론과 결합한 것으로 볼 수 있다.

  • PDF

Estimation of Measurement Uncertainty in Evaluation of Tensile Properties (인장 물성 측정 불확도 평가)

  • Huh, Y.H.;Lee, H.M.;Kim, D.J.;Park, J.S.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.1
    • /
    • pp.73-78
    • /
    • 2010
  • Estimation of tensile properties measurement uncertainty of material was carried out. Sources of uncertainty affecting the measurement of tensile properties were classified and analyzed. The models for uncertainty evaluation of measurands to be determined from tensile test, such as elastic modulus, yield strength and tensile strength, were suggested and derived from the mathematical relations, corresponding to the respective measurands, and the measuring quantities by calculating each sensitivity coefficient of the quantities. Based on these models, the uncertainty of the tensile properties was evaluated from the experimental data of SUS316LN determined according to ISO 6892.

The Measurement of Refractive Index by using Michelson Interferometer with Rotating Sample (Michelson 간섭계를 이용한 굴절률 측정)

  • Kang, Kab Jung;Cha, Jung Won;Kim, Chung-Sik;Kim, Jung Nam
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.73-79
    • /
    • 1999
  • The main purpose of this paper is to construct and analyze the Michelson interferometer with rotating sample in order to measure refractive index of solid plate. The theoretical equation and experimental method was proposed in this work. The measured refractive indexes by this system are $n_{6328}$=1.5159 in BK7 and $n_{6328}$=1.4528 in fused silica. These values make a differences by 0.001 in BK7 and 0.003 in fused silica from those of reference. As a result, Michelson interferometer with rotating sample is very advantageous method to find refractive index of plate sample.

  • PDF

Range Alignment Measurement for Satellite Antenna by Using Theodolite System (데오드라이트 시스템을 이용한 위성 안테나 레인지 얼라인먼트 측정)

  • Park, Hong-Cheol;Son, Yeong-Seon;Yun, Yong-Sik
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.6
    • /
    • pp.134-141
    • /
    • 2004
  • The three-dimensional precision measurement technology for industrial product of middle and/or large scale has been developed. Theodolite measurement system which is one of the technology is widely used in aerospace industry. This paper describes a range alignment method of parabolic antenna to RF probe in the near field range by using the theodolite system, The range alignments of the Ku-band and Ka-band antennas have been accomplished within the requirements, ${\pm}1mm\;and\;{\pm}0.05^{\circ}$.

Room Acoustic Measurement System Using Impulse Response (임펄스응답을 이용한 실내음향 측정 시스템)

    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.63-67
    • /
    • 1999
  • Recently, a method of measuring impulse response is widely used for a room acoustic evaluation instead of measuring reverberation time by white noise excitation. Comparing with the traditional reverberation time measurement, this method has many advantages such as good repeatability and the ability to extract various room acoustic parameters at one measurement. In this study, the author developed a measuring system that can extract mono-aural room acoustic parameters from an impulse response measured with MLS (Maximum Length Sequence) signal excitation. These room acoustic parameters include reverberation times(EDT, RT), speech intelligibilities(C50, C80, D, U50, U80, AI) and sound strength(G). This paper introduces the configuration of the developed measuring system, test results and discussions for the measurements at several rooms.

  • PDF

Calibration Techniques for Low-Level Current Measurement in the Characteristic Analysis System for Semiconductor Devices (저전류 측정을 위한 반도체 소자 특성 분석 시스템에서의 보상 기법)

  • Choi, In-Kyu;Park, Jong-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.111-117
    • /
    • 2002
  • In this paper, we proposed calibration techniques to improve measurement accuracy in the characteristic analysis system for semiconductor devices. Systematic errors can be reduced using proposed calibration techniques. Also, error current reduction procedures including leakage current and offset current are proposed to measure low-level current in pA level. Calibration parameters are calculated and stored by microprocessor using least-square fitting with measured sample data. During measurement time microprocessor corrects measured data using stored calibration parameters. Experimental results show that current measurement error above nA level is less than 0.02%. And they also show that current measurement in pA level can be performed with about 0.2% accuracy.