• Title/Summary/Keyword: 최적운전곡선

Search Result 28, Processing Time 0.029 seconds

Development and Optimal Operation of an Electro-Hydraulic Controlled Rig Type CVT (전자유압제어식 리그형 CVT 개발과 최적운전)

  • Kim, K.W.;Kwon, H.B.;Kim, H.S.;Eun, T.;Park, C.I.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2181-2190
    • /
    • 1993
  • An electro-hydraulic controlled rig type CVT(Continuously Variable Transmission) system was developed and its performance tests were carried out for the optimal operation. A CVT map was suggested based on the speed ration-axial force-torque relationship which was derived from the metal belt CVT mechanics. Also, a real time control and operation software was developed for the electro-hydraulic CVT system. By using the software and the CVT map, the control system was designed for the CVT speed ratio control with various drive modes. The electro-hydraulic CVT system developed in this study showed that the optimal operation algorithm could be obtained for the best fuel economy or the maximum power mode.

Operating Range Expansion of a Closed-Loop Stepping Motor by Optimal Lead Angle Control (초적 Lead Angle 제어에 의한 폐루프 스테핑 전동기의 운전영역 확대)

  • 우광준;이종언;이현창
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.3
    • /
    • pp.80-87
    • /
    • 1995
  • In this paper, we design the microcontroller-based optimal lead angle control system on the basis of the presented maximum average torque formula of the permanent-type stepping motor with respect to the inductance. We confirm that optimal lead angle enlarges the operating range twice as much and increases the torque over all of the operating range in the case of presented formula as well as experimental results.

  • PDF

Design of Heat Pump Renewable Energy System Using Wastewater with a Heat Source (폐수열 히트펌프 재생에너지 시스템 설계)

  • Choo, Yeon-Gyu;Kim, Bong-Gi;Kim, Sung-Du
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.787-790
    • /
    • 2011
  • 본 연구에서는 페수열 회수 보일러에서 버려지는 페수열을 재생하여 에너지를 재활용하기 위하여 퍼지제어 알고리즘을 사용한 지능제어기를 설계하고자 한다. 폐수유입온도의 변화와 폐수유입량의 변화를 파라미터로 하여 컴프레서의 정속운전 대수와 토출온수온도의 특성곡선을 전문가의 지식으로부터 얻을 수 있다. 폐수열 회수 보일러에 유입되는 폐수부하에 따른 컴프레서의 정속운전 대수를 최소화 하기위해 폐수유입온도와 유입량의 변화를 측정하여 최적의 정속운전 대수 및 인버터 운전량을 실시간으로 결정하는 지능제어기를 설계하여 페수열 부하의 변동을 실시간으로 추정하여 최소의 컴프레서 운전대수 및 조작량을 제어함으로써 에너지 효율과 경제성을 극대화할 수 있다.

  • PDF

Analysis on Driving Performance of Linear Induction Motor for Maglev System by Finite Element Method (유한요소법을 이용한 자기부상용 선형유도기의 운전 특성 분석법)

  • Kim, Ki-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4469-4474
    • /
    • 2014
  • This paper proposes a novel analysis method on the driving performance of LIM (linear induction motor) by FEM (finite element method). First, a linear model was converted with a rotation model to perform the dynamic analysis for a long time. Through the FEM model, the slip parameter for the control algorithm could be induced effectively. The LIM for the traction system was performed at a constant V/f in the region of constant torque, and a constant V and variable f in the region of constant power. Several slip characteristic curves according to the voltage and frequency were calculated by FEM in advance. The driving performance was then induced by interpolating the slip characteristic curves according to the load of the vehicle.

Modeling of the Optimal Operation Pattern for Energy Saving of The Trains (전동열차의 운행에너지 절감을 위한 최적 운행 패턴 모델링)

  • Kim, Jung-Hyun;Lee, Se-Hoon;Jun, Sang-Pyo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.12
    • /
    • pp.187-196
    • /
    • 2014
  • In this paper, Minimize driving energy for operation within a defined distance yeokgan fixed time-resolved and determine the nature of the train is traveling, and to model mathematically. Urban rail car cruise in general by the PID controller is used instead of automatically tracking a target value while traveling in energy consumption to be minimized by using optimal control model railroad charyangreul was designed under real operating conditions the same. The actual track conditions apply to the minimum value or a separate listing of cars around the track facility without a driving energy of the automatic operation and to reduce the driving energy. Therefore, actual route chosen straight line 8 / gradient segment / curve for the measured data analysis, such as sections within the city-minute drive each section and presented how the trains to save energy, depending on the pattern of the train station in the region.

The operation properties of DBD reactors in air pressure with varying the capacitance of reactors (정전 용량변화에 따른 대기압 DBD 반응기의 동작 특성 연구)

  • 박봉경;김윤환;장봉철;조정현;김곤호
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.4
    • /
    • pp.440-448
    • /
    • 2001
  • The operation properties of DBD plasma reactors were observed by using 20 kV square pulse at the cylindrical and planar type of reactors in the condition of air pressure. The optimum operation frequency $f_0$ which optimizes the efficiency of operation was found as such $f_0\proptoexp(-C)$ when the current-voltage curve and charge-voltage curve were observed. Using these properties the dissipated power was evaluated. The dissipated power at the optimum frequency of operation was varied as the value of capacitance which is dependent on the structure and the dielectric material of the reactor, and had the maximum value at the specific value of capacitance. With these value of capacitance, DBD reactors which has a high level of efficiency can be formed.

  • PDF

Study on Engine-CVT Consolidated Control(I) -Development of Consolidated Control Algorithm (엔진-CVT 통합제어에 관한 연구(I) -통합제어 알고리즘 개발)

  • 김달철;김현수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.5
    • /
    • pp.86-96
    • /
    • 1997
  • In this paper, engine-CVT consolidated control algorithm was developed. Engine -CVT control strategy suggested uses throttle control based on power difference and CVT ratio control based in CVT ratio map. Simulation results showed that the larger the rate of CVT ratio, the better the engine performance in the optimal operation line. Also, it was found that the engine performance where the magnitude of the acceleration changes abruptly depends on the magnitude of the rate of CVT ratio. Comparing the results of CVT control only without engine control, the engine-CVT control algorithm suggested in this work showed better performance demonstrating that the consolidated control algorithm should be required for the engine optimal operation.

  • PDF

Fuzzy Control of Speed Ratio for Electro-Hydraulic Rig Type CVT (전자 유압식 리그형 CVT의 변속비 퍼지제어)

  • Kim, S.H.;Kim, K.W.;Kim, H.S.;Eun, T.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.3
    • /
    • pp.63-73
    • /
    • 1993
  • In this paper, fuzzy control algorithm for the speed ratio control of the electro-hydraulic rig type continuously variable transmission(CVT) was proposed and the CVT performance tests were carried out for the optimal operation of the engine simulator. The experimental results for the constant throttle and the acceleration modes showed that the engine can be run on the optimum operating line, representing the power and economy mode, by the fuzzy control of the CVT speed ratio. Comparing the PID control with the fuzzy control, it was found that the fuzzy control showed better performance with the faster rising time and smaller steady state error. The result of this study can be used as basic design materials for developing the transmission control unit of the CVT.

  • PDF

Study on Engine-CVT Consolidated Control(II)-Experimental Study (엔진-CVT 통합제어에 관한 연구(II)-실험적 연구)

  • 김달철;김현수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.6
    • /
    • pp.111-119
    • /
    • 1997
  • In this paper, engine-CVT consolidated control performance were investigated experimentally. Engine-CVT consolidated control was composed of engine throttle control based on power difference and CVT ratio control based on CVT ratio map. Experimental results showed that engine optimal operation was obtained while satisfying the driver's desire, i. e., following the given drive mode by engine-CVT consolidated control. Also, it was found that engine performance is subjected to inertia of the powertrain where the magnitude of acceleration changes abruptyly. Comparing with the results of CVT only control, the results of engine-CVT consolidated control showed better performance. Therefore, in order to meet the driver's desire as well as keeping the engine optimal operation, the engine-CVT consolidated control could be suggested as an integral solution.

  • PDF