• Title/Summary/Keyword: 최대하중 한계상태

Search Result 28, Processing Time 0.02 seconds

A Study on the Static and Dynamic Characteristics of Raised Girder Bridges (양각 거더교의 정적·동적특성에 관한 연구)

  • Ji-Yeon Lee;Sung Kim;Sung-Jin Park
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.851-858
    • /
    • 2023
  • Purpose: A study was conducted to ensure the structural safety of a raised girder bridge with improved cross-sectional efficiency compared to the conventional PSC girder. For this purpose, the cross-sectional specifications such as girder length, height, and width were determined, the arrangement of the tendons was designed, and the practical performance of the raised girder under static and dynamic loads was verified. Method: The static performance experiment examined the serviceability limit state by measuring behavioral responses such as deflection and cracking to primary and secondary static loads. In addition, the dynamic load loading experiment measured the acceleration and displacement behavior response over time to calculate the natural frequency and damping ratio to examine the usability limit state. Result: As a result of the static performance test, the deflection value based on the maximum applied load showed stable behavior, and the crack width measured at the maximum applied load level was very small, satisfying the serviceability limit state. In addition, a natural frequency exceeding the natural frequency calculated during the design of the dynamic loading experiment was found, and a damping ratio that satisfies the current regulations was found to be secured.

A Study on Development of Structural Health Monitoring System for Steel Beams Using Strain Gauges (변형률계를 이용한 강재보의 건전도 평가 시스템 개발에 관한 연구)

  • Hahn, Hyun Gyu;Ahn, Hyung Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.99-109
    • /
    • 2012
  • This study aimed to develop a Structural Health Monitoring System for steel beams in the manner of suggesting and verifying a theoretical formula for displacement estimation using strain gauges, and estimating the loading points and magnitude. According to the results of this study, it was found that when a load of 160kN (56% of the yield load) was applied, the error rate of the deflection obtained with a strain gauge at the point of maximum deflection compared to the deflection measured with a displacement meter was within 2%, and that the estimates of the magnitude and points of load application also showed the error rate of not more than 1%. This suggests that the displacement and load of steel beams can be measured with strain gauges and further, it will enable more cost-effective sensor designing without displacement meter or load cell. The Structural Health Monitoring System program implemented in Lab VIEW gave graded warnings whenever the measured data exceeds the specified range (strength limit state, serviceability limit state, yield strain), and both the serviceability limit state and strength limit state could be simultaneously monitored with strain gauge alone.

Inelastic Design of Continuous-Span Composite Plate Girder Bridges by LRFD Method (비탄성 설계법에 의한 플레이트 거더 연속교의 LRFD 설계)

  • Cho, Eun Young;Shin, Dong Ku
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.4
    • /
    • pp.469-481
    • /
    • 2008
  • The inelastic design of the three-span continuous composite plate girder with consideration of moment redistribution over the interior pier is performed using the LRFD method. The design of the girder section, based on the inelastic method, is compared with that by the conventional elastic design. The length of the center span for the three-span continuous bridge ranges from 40m to 70m and the relative ratio of the span length is assumed to be 4:5:4. Although the AASHTO- LRFD specifications are applied in the design of the composite girder, the recently proposed new design live load is used. After determining the maximum positive and negative sections by the elastic design for various limit states, the amount of moment redistributed to the maximum positive moment section is calculated. With the increased design moment due to moment redistribution from the interior pier, the maximum positive section designed by the elastic method is checked for the strength limit state and the service limit state. The maximum negative moment section is redesigned by reducing the size of the steel girder relative to the section designed by the elastic method and the new section is checked for the service limit state. Based on the design results for the five bridges considered in this study, it is estimated that about 23% of steel can be saved in the interior pier section if it is designed by the inelastic method compared with that designed by the elastic method.

Quantitative Damage Index of RC Columns with Non-seismic Details (비내진상세를 가지는 철근콘크리트 기둥의 정량적 손상도 평가 기준)

  • Kim, Kyung-Min;Oh, Sang-Hoon;Choi, Kwang-Yong;Lee, Jung-Han;Park, Byung-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.11-20
    • /
    • 2013
  • In this paper, the quantitative damage index for reinforced concrete (RC) columns with non-seismic details were presented. They are necessary to carry out the postearthquake safety evaluation of RC buildings under 5 stories without seismic details. The static cyclic test of the RC frame sub-assemblage that was an one span and actual-sized was first conducted. The specimen collapsed by the shear failure after flexural yielding of a column, lots of cracks on the surfaces of columns and beam-column joints and the cover concrete splitting at the bottom of columns occurred. The damage levels of these kinds of columns with non-seismic details were classified to five based on the load-displacement relationship by the test result. The residual story drift ratios and crack widths were then adapted as the quantitative index to evaluate the damage limit states because those values were comparatively easy to measure right after earthquakes. The highest one among the residual story drift ratios under the similar maximum story drift ratio decided on the residual story drift ratio of each damage limit state. On the other hand, the lowest and average ones among the respective residual shear and flexural widths under the similar maximum story drift ratio decided on the residual shear and flexural widths of each damage limit state, respectively. These values for each damage limit state resulted in being smaller than those by the international damage evaluation guidelines that are for seismically designed members under the same deformations.

Earth Pressure on a Rigid wall due to Loads Condition and Distance (상재하중의 크기와 이격거리에 따른 강성벽체의 토압분포)

  • Oh, Bun-Jin;Lee, Sang-Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.12
    • /
    • pp.51-60
    • /
    • 2010
  • Earth pressure due to gravity generally increases linearly with the depth, but the distribution of earth pressure due to surface load depends on the loading condition, the ground condition, and the boundary condition. In this study, the earth pressure on a rigid wall due to the vertical surface load was measured in experiments. Rigid wall was built in the model test box, and it was filled with homogeneous sandy ground (width 30 cm, height 88 cm, length 110 cm). Rigid wall was composed of 8 segments, which were tested on the two load cells. In the tests, we observed the distribution of the earth pressure on the rigid wall depending on the vertical surface load and it's location. According to the test results, the lateral earth pressure due to the vertical surface load showed its maximum value at a constant depth and decreased with the depth, to the negligible value at the critical depth. The critical depth and the depth at which lateral earth pressure reaches its maximum were not decided by the magnitude of the vertical surface load. They were dependant on the distance from the rigid wall.

A Study on the ALFD Design of Rolled Beams (압연형교의 ALFD설계에 관한 연구)

  • Chung, Kyung-Hee;Kim, Jin-Sung;Yang, Seung-Ie
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.4
    • /
    • pp.91-97
    • /
    • 2003
  • The maximum moment may occur at interior supports of continuous bridges. If the bigger moment is applied on them, a local yielding at interior supports may occur. They may show plastic behaviors, and the moment will be redistributed. The strength design, L.F.D., redistributes 10% of the negative moment which is obtained from the elastic analysis. However, A.L.F.D method computes the moment which is redistributed. This moment is called automoment. The moment-rotation curve is needed to find automoment. In this paper moment-rotation curve for compact sections suggested from AASHTO Guide Specifications is used to find automoment. Based on A.L.F.D. limit states specification method, a three-span continuous bridge is designed.

A Numerical Analysis for Stress Concentration of Openings in Offshore Tubular Steel Tower under Design Loading Condition (설계하중조건에 따른 해상풍력 강재타워 출입구에 발생되는 응력집중에 대한 해석적 연구)

  • Reyno, Hannah;Park, Jong-Sup;Kang, Sung-Yong;Kang, Young-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1516-1523
    • /
    • 2015
  • This study investigates the stress concentration factor of a door opening of an offshore tubular steel tower. The tubular steel tower is subjected to eight (8) different load combinations which are deemed to be normal and abnormal operating cases for the ultimate limit state and serviceability limit state. Analytical method using parametric equations and numerical method of finite element are used to analyze the stress components as well as any translations or rotations where the flow of stress is interfered with. A finite element program, ABAQUS, is used for the numerical method analysis. Trends of the stress concentration in the localized area near the opening are studied, and points of interest are defined for comparison among three different cases of tubular steel tower: without door and without reinforcement; without door opening and with reinforcement; and with door opening and with reinforcement. Findings are tabulated and shown in illustrative charts, and conclusions are made.

Estimation of Dynamic Interface Friction Properties of Geosynthetics (토목섬유의 동적 경계면 마찰특성 평가)

  • 김동진;서민우;박준범;박인준
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.265-275
    • /
    • 2003
  • In this study, shaking table tests were conducted to estimate dynamic interface properties between geosynthetics such as geomembrane, geotextile and geosynthetic clay liner. Accelerations of both shaking table and upper box, and relative displacements between geosynthetics under dynamic loading were measured. Also, the influence of normal stress, frequency of excitation and dry/wet conditions were investigated through the analyses of test results. from the test results, it was found that there is a limited acceleration below which dynamic farce can be transmitted between geosynthetics without the loss of horizontal acceleration. Dynamic interface friction angle between geosynthetics could be calculated through the limited acceleration. Relative displacements induced along geosynthetic interfaces under dynamic loading were not consistent depending on the type of interface and test conditions. The maximum slip displacements between geosynthetics are normalized and normalized slip equations were developed for each interface. By using the normalized slip equation, maximum slip displacements for the geosynthetic interface could be predicted for the given base acceleration and frequency of excitation.

Development of Long-Span Steel-Precast Composite Beam for Green Apartment Building (장스팬이 가능한 친환경 공동주택용 철골 프리캐스트 합성보 개발)

  • Yoon, Tae-Ho;Hong, Won-Kee;Park, Seon-Chee;Yune, Dai-Young
    • KIEAE Journal
    • /
    • v.11 no.1
    • /
    • pp.9-14
    • /
    • 2011
  • Currently, the multi-residential apartments used in Korea are mostly bearing wall apartments which don't satisfy consumers for the lack of architectural plan flexibility. And due to remodelling-incompatible, bearing wall apartments have to be reconstructed. It is, thus, necessary to develop multi-residential apartments utilizing composite beam that can replace the conventional bearing wall-type apartment buildings. Composite beams proposed in this paper ensure modification of space and quality control, while the floor heights are maintained at the same floor height as in bearing wall structures. This study analyzes the experimental behavior of composite beams with proper combination of structural steel, reinforced concrete, and precast concrete. By comparing with the theoretical analysis and experimental results, the accuracy of flexural moment capacity and neutral axis was evaluated. The experiments were performed by two simply-supported specimens using loading and unloading. When the analysis results were compared with the experimental results, the flexural moment capacity of the composite beam was shown with an error of approximately -0.5 to 0.1% at the maximum load limit state.

Seismic Performance Evaluation on Bending Deformation of 2-Ply and 3-Ply Bellows Expansion Pipe Joints (2겹 및 3겹 벨로우즈 신축배관이음의 휨 변형에 대한 내진성능평가 )

  • Sung-Wan Kim;Sung-Jin Chang;Dong-Uk Park;Bub-Gyu Jeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.2
    • /
    • pp.33-41
    • /
    • 2023
  • The application of seismic separation joints that can improve the deformation capacity of piping is an effective way to improve seismic performance. Seismic separation joints capable of axial expansion and bending deformation are installed where deformation is expected and used for the purpose of safely protecting the piping. Bellows are flexible and have low stiffness, so they can be used as seismic separation joints because they have excellent ability to respond to relatively large deformation. In this study, the seismic performance and limit state for bending deformation of 2-ply and 3-ply bellows specimens were evaluated. Seismic performance was evaluated by applying an increasing cyclic load to consider low-cycle fatigue due to seismic load. In order to confirm the margin for the limit state of the evaluated seismic performance, an experiment was conducted in which a cyclic loading of constant amplitude was applied. As a result of the experiment, it was confirmed that the bellows specimen was made of stainless steel and had a high elongation, so that the 2-ply bellows specimen had the limit performance of resisting within 3 cycles even at the maximum forced displacement of the 3-ply bellows specimen.