• Title/Summary/Keyword: 촬영 각도

Search Result 1,394, Processing Time 0.028 seconds

A Study on Development of the GPIR system Receiver Using G-Files (G-File을 이용한 GPIR 시스템 수신기 개발)

  • Choi, Sang-Kyoon;Kim, Jae-Saeng
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.3
    • /
    • pp.336-342
    • /
    • 2010
  • GPIR(GPS Position Information Revision) system is a new concept of GPS system which utilizes database containing the location of taking a picture by the existing GPS, an angle between a camera and a subject and the location information of buildings and minimizes the GPS's own margin of error and there by provides the services, such as location-guiding via GPS and way-guiding via navigation in an exact and precision way more than before. GPIR system comprehends the location of taking photos via GPS information saved in G-files, searches database in the direction of taking a photo at a photo-taking position via location information and the photo-taking directional angle. And GPIR system corrects the GPS information searched to the location of a subject, again saves such information in a G-file and is ready for receiving more detailed location of the subject. This study explores into the design and development of a receiver which a GPIR user is able to utilize its system as well as the design of the receiver's prototypes.

Effects of vertical head rotation on the posteroanterior cephalometric measurements (정모두부방사선사진 촬영시 두부의 수직회전에 따른 투사오차)

  • Koh, Eun-Hee;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.33 no.2 s.97
    • /
    • pp.73-84
    • /
    • 2003
  • This study was performed to find out how much projection errors in the cephalometric measurements were made by vertical head rotation in taking posteroanterior cephalograms. 25 adults without any apparent facial asymmetry or severe sagittal skeletal discrepancy were selected and the posteroanterior cephalograms were taken with the head rotated $5^{\circ},\;10^{\circ}$ superior and inferior each to the reference $position(0^{\circ})$. The 7 height, 5 width and 6 angular measurements were taken at each 5 positions. Through the statistical analysis of all measurements taken at each rotated position, folowing results were obtained.1. The projection errors of height measurements were remarkably target than those of width or angular measure nents. f. Among the height measurements, the farther to the rotation axis the measurements were, the larger the projection errors were. 3. Among the width measurements, mandibular width and mandibular width of mandibular first molars showed significant differences between the values taken at each rotated position, while nasal width, maxillary width and intermolar width of maxillary first molars did not. 4. Among the angular measurements, the angle between horizontal reference line and the line that is connected to crista galli and antegonion or maxillare showed significant differences between the values taken at each rotated Position. The above results suggest that it is needed to the effort to keep constant head position for taking the useful posteroanterior cephalogra, because projection errors are caused by vertical head rotation.

Technical Improvement for Spine Radiography by Comparing Scoliotic and Lordotic Angle with Different Positioning Methods (촬영자세별 척추측만각과 척추전만각의 비교 분석에 따른 개선 방안)

  • Jung, Jae-Yeon;Son, Soon-Yong;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.263-269
    • /
    • 2011
  • Since the spine radiography were explained differently at every several hospitals and textbooks. the technique has not been accurately defined and interfered each other. We would like to define the most appropriate positioning for clinical cases, and reference books, by comparing scoliotic angle and lordotic angle. From Mar 2009 to Sep 2011, 85 patient cases were studied, who had not been undergone surgical treatment among spondylopathy patients. Scoliotic angle and lordotic angle were measured, using Cobb's method. We analyzed statistically using t-test(SPSS 18), and evaluated spine general radiography position. Moreover, we researched on the actual condition at 10 university hospitals in Seoul. The results of scoliotic angle measurement, the value at erect position showed 20.98% higher than supine position, and it has statistical significance (p<.01). In lordotic angle measurement, the value at neutral holding position represented 29.3% higher than supine position, and it also has statistical significance(p<.01). The results of clinical survey, supine posine(70.0%) took much higher possession than erect position(30.0%). In conclusion, compare to supine position, erect position shows increased scoliotic and lordotic angle. It was agreed with the importance of clinical erect position radiography, which gravity affects. So clinical radiologist must recognize the difference, and conduct an accurate study.

llumination change robust stereo matching using retinex processing (레티넥스 처리에 기반한 조명 변화 환경에 효과적인 스테레오 매칭 기법)

  • Heo, Yong-Seok;Lee, Kyoung-Mu;Lee, Sang-Uk
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.227-228
    • /
    • 2008
  • 본 논문에서는 조명 변화가 있는 스테레오 이미지에 대하여 레티넥스 알고리즘을 이용하여 효과적으로 3차원 정보를 추출하는 방법을 제안한다. 이미지나 비데오는 영상 취득시 여러 가지 원인에 의하여 조명 변화를 겪게 된다. 이미지나 비데오를 촬영하는 시간 간격 차이, 촬영 각도 차이, 촬영 장치의 변화 등이 그 원인이다. 기존의 스테레오 알고리즘들은 정합하려는 영상들 사이에 컬러 일치성을 가정하고 있으므로, 이러한 조명 변화의 영향을 받는 이미지들에 대해서 3차원 정보를 추출하면 적지 않은 에러가 발생하게 된다. 따라서, 이러한 문제를 해결하기 위하여 레티넥스 기법을 이용하여 이러한 변화에 둔감한 스테레오 정합 기법을 제안한다. 여러 가지 데이터에 대하여 실험을 한 결과, 제안하는 방법이 효과적임을 확인하였다.

  • PDF

Study on the Improvement of Accuracy in a Plain Slope Analysis Using the Bundle Adjustment (번들조정법에 의한 지상시설물 경사면 해석의 정확도 향상에 관한 연구)

  • 유복모;조기성;허두홍
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.7 no.1
    • /
    • pp.59-65
    • /
    • 1989
  • In this study, improvement of accuracy in a plain slope analysis is a main object using the bundle adjustment with changing the convergent angles and the configurations of control points when we can't take convergent case because of poor environment around establishment and cultural assets. From converged photographing using the angle of deviation, it was possible to improve accuracy in a plain slope analysis.

  • PDF

Photo Clustering using Maximal Clique Finding Algorithm and Its Visualized Interface (최대 클리크 찾기 알고리즘을 이용한 사진 클러스터링 방법과 사진 시각화 인터페이스)

  • Ryu, Dong-Sung;Cho, Hwan-Gue
    • Journal of the Korea Computer Graphics Society
    • /
    • v.16 no.4
    • /
    • pp.35-40
    • /
    • 2010
  • Due to the distribution of digital camera, many work for photo management has been studied. However, most work use a sequential grid layout which arranges photos considering one criterion of digital photo. This interface makes users have lots of scrolling and concentrate ability when they manage their photos. In this paper, we propose a clustering method based on a temporal sequence considering their color similarity in detail. First we cluster photos using Cooper's event clustering method. Second, we makes more detailed clusters from each clustered photo set, which are clustered temporal clustering before, using maximal clique finding algorithm of interval graph. Finally, we arrange each detailed dusters on a user screen with their overlap keeping their temporal sequence. In order to evaluate our proposed system, we conducted on user studies based on a simple questionnaire.

Design of Water Surface Hovering Drone for Underwater Stereo Photography (수중 입체촬영을 위한 수면호버링 드론 설계)

  • Kim, Hyeong-Gyun;Kim, Yong-Ho
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.6
    • /
    • pp.7-12
    • /
    • 2019
  • In order to shoot underwater, the photographer must be equipped with shooting equipment and enter into the water. Since the photographer directly enters the water, safety accidents occur frequently due to various obstacles or deep water in the water. The proposed underwater stereo photography technique can solve the safety accident problem caused by the entry of the photographer into the water by using the drone for underwater photographing. In addition, this technique has the advantage of obtaining underwater images at low cost. In this study, the angle of the proposed cam for stereoscopic photography was analyzed and the condition that the proper stereoscopic image can be viewed was defined as the distance from the floor of 18cm to the floor distance of 41.4cm. This provision is proposed to be used to adjust the height of the shooting area descended by the elevation chain of the water surface hovering drones.

The Tangential Projection Method for Checking Existence and Nonexistence of Radius Groove Penetration of Screw after Distal Radius Fracture Operation Used the T-type Plate (T형 금속판을 이용한 요골 원위부 골절 수술 후 나사못의 요골구 관통 유무를 확인하기 위한 접선방향 촬영법)

  • Seo, Sun-Youl;Hong, Ki-Jang;Han, Man-Seok;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.335-340
    • /
    • 2010
  • This paper is about a projection method to check existence of radius groove penetration of screw after distal radius fracture operation using the T-type plate. Angle of Radius groove was analyzed by fifty one CT images that contains patients' wrist and twenty cases of radius specimens. After making radius phantom by plaster, we set the screw so that it penetrated 2.4 mm depth of radius groove. Then, we projected the phantom by X-ray in change of the elevation and supination angle of distal radius by 5 degree interval on 0~30 degree. The average value of groove angle in the wrist CT images was 14.4 degree and the radius specimens was 16.3 degree. Screws penetrating radius groove of the phantom have different lengths according to elevation angle and supination angle. Consequently, in order to confirm existence and nonexistence of radius groove penetration of the screw in tangential projection after distal radius fracture operation using the T-type plate, we recommend 5 degree of elevation angle and 20 degree of supination angle.

Analysis of influence of twisting angle between contacts on arc behavior in spiral type VI by analysing arc photographs and arc voltage (나선형 VI전극 내부에서 아크촬영사진과 아크전압분석을 통한 전극간 비틀림 각도가 아크거동에 미치는 영향 분석)

  • Kim, Byoung-Chul;Park, Jong-Bae;Park, Hongl-Tae;Kang, Seong-Wha;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.151-152
    • /
    • 2008
  • 본 논문에서는 전극간의 비틀림 각도가 아크거동에 미치는 영향을 알아보기 위해 고속카메라를 이용한 아크촬영과 아크전압측정을 동반한 전류차단시험을 실시하였다. 측정결과를 이용한 아크거동 분석결과를 각 모델에 대한 유한요소해석을 통한 로렌츠 힘 계산결과와 결부시켜 비틀림 각도가 아크거동에 미치는 영향을 분석하였다.

  • PDF

Capturing system for wide viewing hologram generation (광시야각 홀로그램 합성을 위한 촬영 시스템)

  • Kim, Youngrok;Sung, Hyunsik;Hong, Keehoon;Choi, kihong;Min, Sung-Wook
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2020.07a
    • /
    • pp.561-562
    • /
    • 2020
  • 기하학적 위상렌즈를 활용한 광시야각 홀로그램 합성을 위한 시스템을 제안하고 설계하여 제작하였다. 광시야각 홀로그램은 실시간 홀로그램 영상을 녹화하는 과정에서 동시에 물체의 다른 파면을 기록할 수 있기 때문에 물체의 3 차원 정보를 일련의 알고리즘을 통해 데이터화 시키는 과정을 가능하게 한다. 본 논문에서는 기하학적 위상렌즈와 편광 이미지 센서를 결합해 비간섭성 광원의 홀로그램을 기록할 수 있는 자가 간섭 디지털 홀로그래피 시스템을 이용하여 관찰하고자 하는 물체의 파면을 다각도에서 기록하는 광시야각 홀로그램 촬영 시스템을 개발하였다.

  • PDF