• Title/Summary/Keyword: 촬영

Search Result 8,327, Processing Time 0.039 seconds

Diagnosis of Fatty Liver Complicated by Simple Obesity in Children: Serum ALT and Its Correlation with Abdominal CT and Liver Biopsy (소아의 단순성 비만증에 의한 지방간의 진단: ALT치와 복부 전산화단층촬영 및 간생검 소견간의 상관관계)

  • Lee, Seong-Hee;Kim, Hwa-Jung;Oh, Jae-Cheol;Han, Hae-Jeong;Kim, Hee-Sup;Tchah, Hann;Park, Ho-Jin;Shin, Mi-Keong;Lee, Min-Jin;Lee, Sang-Chun
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.2 no.2
    • /
    • pp.153-163
    • /
    • 1999
  • Purpose: The purpose of our study is to provide useful information for diagnostic methods of fatty liver by childhood simple obesity and to provide correlation between serum alanine aminotransferase (ALT) for screening test and abdominal computerized tomography (CT) and liver biopsy for confirmative diagnostic methods of fatty liver. Methods: Among 78 obese childrens who visited our hospital, CT was carried out in 26 childrens. Of these, liver biopsy was carried out in 15 childrens who had high obesity index or severe elevated ALT. Based on the level of serum ALT, 26 cases were classified into 3 groups, and compared with physical measurements and degree of fatty infiltration on CT and liver biopsy. Results: 1) Correlation between ALT and physical measurements: Of 26 obese children, ALT was abnormally elevated (>30 IU/L) in 17 cases (67.4%) but there was no significant correlation between ALT and physical measurements (p>0.05). 2) Correlation between degree of fatty infiltration on CT and ALT: Of 26 cases, 13 cases (50%) revealed fatty liver on CT. The degree of fatty liver on CT had significant correlation with elevation of ALT (p<0.05). 3) Correlation between the degree of fatty infiltration on liver biopsy and ALT: Liver biopsy was performed in 15 cases of which 14 cases revealed fatty liver. But one case had normal hepatic histology with severe obesity and normal ALT. Fourteen fatty liver cases on liver biopsy were classified into 3 groups by the degree of fatty infiltration and analysed with obesity index and ALT. The histologic hepatic steatosis had no significant correlation with obesity index (p>0.05), but significant correlation with ALT (p<0.05). 4) Correlation between CT and liver biopsy finding: Both CT and liver biopsy were performed in 15 cases of which 6 cases revealed normal finding on CT and 9 cases manifested fatty liver. There was significant correlation between CT and liver biopsy findings (r=0.6094). Conclusion: The results of our study suggest that abdominal CT and liver biopsy are useful and accurate methods of estimating fatty liver in the childhood obesity. But biochemical abnormalities of routine liver function tests dot not correlate well with severity of the fatty liver and liver injury.

  • PDF

Comparative Analysis of Delivery Management in Various Medical Facilities (의료기관별 분만관리 양상의 비교 분석)

  • Park, Jung-Han;You, Young-Sook;Kim, Jang-Rak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.22 no.4 s.28
    • /
    • pp.555-577
    • /
    • 1989
  • This study was conducted to compare the delivery management including laboratory tests, medication and surgical procedures for the delivery in various medical facilities. Two university hospitals, two general hospitals, three hospitals, two private obstetric clinics, and two midwifery clinics in a large city were selected as they permitted the investigators to abstract the required data from the medical and accounting records. The total number of deliveries occurred at these 11 facilities between 15 January and 15 February, 1989 was 789 among which 606(76.8%) were vaginal deliveries and 183 (23.3%) were C-sections. For the normal vaginal deliveries, CBC, Hb/Hct level, blood typing, VDRL, hepatitis B antigen and antibody, and urinalysis were routinely done except the private clinics and midwifery clinics which did not test for hepatitis B and Hb/Hct level at all. In one university hospital ultrasonography was performed in 71.4% of the mothers and in one general hospital liver function test was done in 76.7% of the mothers. For the C-section, chest X-ray, bleeding/clotting time and liver function test were routinely done in addition to the routine tests for the normal vaginal deliveries. Episiotomy was performed in 97.2% of the vaginal deliveries. The type and duration of fluid infused and antibiotics administered showed a wide variation among the medical facilities. In one university hospital antibiotics was not administered after C-section at all while in the general hospitals and hospitals one or two antibiotics were administered for one week on the average. In one private clinic one pint of whole blood was transfused routinely. A wide variation was observed among the medical facilities in the use of vitamin, hemostatics, oxytocics, antipyreptics, analgesics, anti-inflammatory agents. sedatives. digestives. stool softeners. antihistamines. and diuretics. Mean hospital day for the normal vaginal deliveries of primipara was 2.6 days with little variation except one hospital with 3.5 days. Mean hospital day for the C-section of primipara was 7.5 days and that of multipara was 7.6 days and it ranged between 6.5 days and 9.4 days. Average hospital fee for a normal vaginal delivery without the medical insurance coverage was 182,100 Won for the primipara and 167,300 Won for the multipara. In case of the primipara covered by the medical insurance a mother paid 82,400 Won and a multiparous mother paid 75,600 Won. Average hospital fee for a C-section without the medical insurance was 946,500 Won for the primipara and 753,800 Won for the multipara. In case of the primipara covered by the medical insurance a mother paid 256,200 Won and a multiparous mother paid 253,700 Won. Average hospital fee for a normal vaginal delivery in the university hospitals showed a remarkable difference, 268,000 Won vs 350,000 Won, as well as for the C-section. A wide variation in the laboratory tests performed for a normal vaginal delivery and a C-section as well as in the medication and hospital days brought about a big difference in the hospital fee and some hospitals were practicing the case payment system. Thus, standardization of the medical care to a certain level is warranted for the provision of adequate medical care for delivery.

  • PDF

Evaluation of a colloid gel(Slime) as a body compensator for radiotherapy (Colloid gel(Slime)의 방사선 치료 시 표면 보상체로서의 유용성 평가)

  • Lee, Hun Hee;Kim, Chan Kyu;Song, Kwan Soo;Bang, Mun Kyun;Kang, Dong Yun;Sin, Dong Ho;Lee, Du Heon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.191-199
    • /
    • 2018
  • Purpose : In this study, we evaluated the usefulness of colloid gel(slime) as a compensator for irregular patient surfaces in radiation therapy. Materials and Methods : For this study, colloid gel suitable for treatment was made and four experiments were conducted to evaluate the applicability of radiation therapy. Trilogy(Varian) and CT(SOMATOM, Siemens) were used as treatment equipment and CT equipment. First, the homogeneity according to the composition of colloid gel was measured using EBT3 Film(RIT). Second, the Hounsfield Unit(HU) value of colloid gel was measured and confirmed by CRIS phantom, Eclipse RTP(Eclipse 13.1, Varian) and CT. Third, to measure the deformation and degeneration of colloid gel during the treatment period, it was measured 3 times daily for 2 weeks using an ion chamber(PTW-30013, PTW). The fourth experiment was compared the treatment plan and measured dose distributions using bolus, rice, colloid gel and additional, dose profiles in an environment similar to actual treatment using our own acrylic phantom. Result : First experiment, density of the colloid gel cases 1, 2 and 3 was $1.02g/cm^3$, $0.99g/cm^3$ and $0.96g/cm^3$. When the homogeneity was measured at 6 MV and 9 MeV, case 1 was more homogeneous than the other cases, as 1.55 and 1.98. In the second experiment, the HU values of case 1, 2, 3 were 15 and when the treatment plan was compared with the measured doses, the difference was within 1 % at all 9, 12 MeV and a difference of -1.53 % and -1.56 % within the whole 2 % at 6 MV. In the third experiment, the dose change of colloid gel was measured to be about 1 % for 2 weeks. In the fourth experiment, the dose difference between the treatment plan and EBT3 film was similar for both colloid gel and bolus, rice at 6 MV. But colloid gel showed less dose difference than bolus and rice at 9 MeV. Also, dose profile of colloid gel showed a more uniform dose distribution than the bolus and rice. Conclusion : In this study, the density of colloid gel prepared for radiation therapy was $1.02g/cm^3$ similar to the density of water, and alteration or deformation was not observed during the radiotherapy process. Although we pay attention to the density when manufacturing colloid gel, it is sufficient in that it can deliver the dose uniformly through the compensation of the patient's body surface more than the bolus and rice, and can be manufactured at low cost. Further studies and studies for clinical applications are expected to be applicable to radiation therapy.

  • PDF

Excavation of Kim Jeong-gi and Korean Archeology (창산 김정기의 유적조사와 한국고고학)

  • Lee, Ju-heun
    • Korean Journal of Heritage: History & Science
    • /
    • v.50 no.4
    • /
    • pp.4-19
    • /
    • 2017
  • Kim Jeong-gi (pen-name: Changsan, Mar. 31, 1930 - Aug. 26, 2015) made a major breakthrough in the history of cultural property excavation in Korea: In 1959, he began to develop an interest in cultural heritage after starting work as an employee of the National Museum of Korea. For about thirty years until he retired from the National Research Institute of Cultural Heritage in 1987, he devoted his life to the excavation of our country's historical relics and artifacts and compiled countless data about them. He continued striving to identify the unique value and meaning of our cultural heritage in universities and excavation organizations until he passed away in 2015. Changsan spearheaded all of Korea's monumental archeological excavations and research. He is widely known at home and abroad as a scholar of Korean archeology, particularly in the early years of its existence as an academic discipline. As such, he has had a considerable influence on the development of Korean archeology. Although his multiple activities and roles are meaningful in terms of the country's archaeological history, there are limits to his contributions nevertheless. The Deoksugung Palace period (1955-1972), when the National Museum of Korea was situated in Deoksugung Palace, is considered to be a time of great significance for Korean archeology, as relics with diverse characteristics were researched during this period. Changsan actively participated in archeological surveys of prehistoric shell mounds and dwellings, conducted surveys of historical relics, measured many historical sites, and took charge of photographing and drawing such relics. He put to good use all the excavation techniques that he had learned in Japan, while his countrywide archaeological surveys are highly regarded in terms of academic history as well. What particularly sets his perspectives apart in archaeological terms is the fact that he raised the possibility of underwater tombs in ancient times, and also coined the term "Haemi Culture" as part of a theory of local culture aimed at furthering understanding of Bronze Age cultures in Korea. His input was simply breathtaking. In 1969, the National Research Institute of Cultural Heritage (NRICH) was founded and Changsan was appointed as its head. Despite the many difficulties he faced in running the institute with limited financial and human resources, he gave everything he had to research and field studies of the brilliant cultural heritages that Korea has preserved for so long. Changsan succeeded in restoring Bulguksa Temple, and followed this up with the successful excavation of the Cheonmachong Tomb and the Hwangnamdaechong Tomb in Gyeongju. He then explored the Hwangnyongsa Temple site, Bunhwangsa Temple, and the Mireuksa Temple site in order to systematically evaluate the Buddhist culture and structures of the Three Kingdoms Period. We can safely say that the large excavation projects that he organized and carried out at that time not only laid the foundations for Korean archeology but also made significant contributions to studies in related fields. Above all, in terms of the developmental process of Korean archeology, the achievements he generated with his exceptional passion during the period are almost too numerous to mention, but they include his systematization of various excavation methods, cultivation of archaeologists, popularization of archeological excavations, formalization of survey records, and promotion of data disclosure. On the other hand, although this "Excavation King" devoted himself to excavations, kept precise records, and paid keen attention to every detail, he failed to overcome the limitations of his era in the process of defining the nature of cultural remains and interpreting historical sites and structures. Despite his many roles in Korean archeology, the fact that he left behind a controversy over the identity of the occupant of the Hwangnamdaechong Tomb remains a sore spot in his otherwise perfect reputation.

Evaluating efficiency of application the skin flash for left breast IMRT. (왼쪽 유방암 세기변조방사선 치료시 Skin Flash 적용에 대한 유용성 평가)

  • Lim, Kyoung Dal;Seo, Seok Jin;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.49-63
    • /
    • 2018
  • Purpose : The purpose of this study is investigating the changes of treatment plan and comparing skin dose with or without the skin flash. To investigate optimal applications of the skin flash, the changes of skin dose of each plans by various thicknesses of skin flash were measured and analyzed also. Methods and Material : Anthropomorphic phantom was scanned by CT for this study. The 2 fields hybrid IMRT and the 6 fields static IMRT were generated from the Eclipse (ver. 13.7.16, Varian, USA) RTP system. Additional plans were generated from each IMRT plans by changing skin flash thickness to 0.5 cm, 1.0 cm, 1.5 cm, 2.0 cm and 2.5 cm. MU and maximum doses were measured also. The treatment equipment was 6MV of VitalBeam (Varian Medical System, USA). Measuring device was a metal oxide semiconductor field-effect transistor(MOSFET). Measuring points of skin doses are upper (1), middle (2) and lower (3) positions from center of the left breast of the phantom. Other points of skin doses, artificially moved to medial and lateral sides by 0.5 cm, were also measured. Results : The reference value of 2F-hIMRT was 206.7 cGy at 1, 186.7 cGy at 2, and 222 cGy at 3, and reference values of 6F-sIMRT were measured at 192 cGy at 1, 213 cGy at 2, and 215 cGy at 3. In comparison with these reference values, the first measurement point in 2F-hIMRT was 261.3 cGy with a skin flash 2.0 cm and 2.5 cm, and the highest dose difference was 26.1 %diff. and 5.6 %diff, respectively. The third measurement point was 245.3 cGy and 10.5 %diff at the skin flash 2.5 cm. In the 6F-sIMRT, the highest dose difference was observed at 216.3 cGy and 12.7 %diff. when applying the skin flash 2.0 cm for the first measurement point and the dose difference was the largest at the application point of 2.0 cm, not the skin flash 2.5 cm for each measurement point. In cases of medial 0.5 cm shift points of 2F-hIMRT and 6F-sIMRT without skin flash, the measured value was -75.2 %diff. and -70.1 %diff. at 2F, At -14.8, -12.5, and -21.0 %diff. at the 1st, 2nd and 3rd measurement points, respectively. Generally, both treatment plans showed an increase in total MU, maximum dose and %diff as skin flash thickness increased, except for some results. The difference of skin dose using 0.5 cm thickness of skin flash was lowest lesser than 20 % in every conditions. Conclusion : Minimizing the thickness of skin flash by 0.5 cm is considered most ideal because it makes it possible to keep down MUs and lowering maximum doses. In addition, It was found that MUs, maximum doses and differences of skin doses did not increase infinitely as skin flash thickness increase by. If the error margin caused by PTV or other factors is lesser than 1.0 cm, It is considered that there will be many advantages in with the skin flash technique comparing without it.

  • PDF

Radiation Therapy Using M3 Wax Bolus in Patients with Malignant Scalp Tumors (악성 두피 종양(Scalp) 환자의 M3 Wax Bolus를 이용한 방사선치료)

  • Kwon, Da Eun;Hwang, Ji Hye;Park, In Seo;Yang, Jun Cheol;Kim, Su Jin;You, Ah Young;Won, Young Jinn;Kwon, Kyung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.75-81
    • /
    • 2019
  • Purpose: Helmet type bolus for 3D printer is being manufactured because of the disadvantages of Bolus materials when photon beam is used for the treatment of scalp malignancy. However, PLA, which is a used material, has a higher density than a tissue equivalent material and inconveniences occur when the patient wears PLA. In this study, we try to treat malignant scalp tumors by using M3 wax helmet with 3D printer. Methods and materials: For the modeling of the helmet type M3 wax, the head phantom was photographed by CT, which was acquired with a DICOM file. The part for helmet on the scalp was made with Helmet contour. The M3 Wax helmet was made by dissolving paraffin wax, mixing magnesium oxide and calcium carbonate, solidifying it in a PLA 3D helmet, and then eliminated PLA 3D Helmet of the surface. The treatment plan was based on Intensity-Modulated Radiation Therapy (IMRT) of 10 Portals, and the therapeutic dose was 200 cGy, using Analytical Anisotropic Algorithm (AAA) of Eclipse. Then, the dose was verified by using EBT3 film and Mosfet (Metal Oxide Semiconductor Field Effect Transistor: USA), and the IMRT plan was measured 3 times in 3 parts by reproducing the phantom of the head human model under the same condition with the CT simulation room. Results: The Hounsfield unit (HU) of the bolus measured by CT was $52{\pm}37.1$. The dose of TPS was 186.6 cGy, 193.2 cGy and 190.6 cGy at the M3 Wax bolus measurement points of A, B and C, and the dose measured three times at Mostet was $179.66{\pm}2.62cGy$, $184.33{\pm}1.24cGy$ and $195.33{\pm}1.69cGy$. And the error rates were -3.71 %, -4.59 %, and 2.48 %. The dose measured with EBT3 film was $182.00{\pm}1.63cGy$, $193.66{\pm}2.05cGy$ and $196{\pm}2.16cGy$. The error rates were -2.46 %, 0.23 % and 2.83 %. Conclusions: The thickness of the M3 wax bolus was 2 cm, which could help the treatment plan to be established by easily lowering the dose of the brain part. The maximum error rate of the scalp surface dose was measured within 5 % and generally within 3 %, even in the A, B, C measurements of dosimeters of EBT3 film and Mosfet in the treatment dose verification. The making period of M3 wax bolus is shorter, cheaper than that of 3D printer, can be reused and is very useful for the treatment of scalp malignancies as human tissue equivalent material. Therefore, we think that the use of casting type M3 wax bolus, which will complement the making period and cost of high capacity Bolus and Compensator in 3D printer, will increase later.

Bibliographic Study on 『ChungMinKongKeicho (忠愍公啓草)』 by YI Sun-sin (이순신의 『충민공계초(忠愍公啓草)』에 대한 서지적 고찰)

  • Ro, Seung-Suk
    • Korean Journal of Heritage: History & Science
    • /
    • v.49 no.2
    • /
    • pp.4-19
    • /
    • 2016
  • Jangkei(狀啓) made to the Royal Court by Yi Sun-sin during the Japanese invasions of Korea is handed down under the names of Jangcho(狀草), Keicho(啓草), Keibon(啓本) and others depending on copying patterns of those times and later times as it was copied out by a third person. In particular, "YimjinJangcho(壬辰狀草)" which Yi drew up during his service as the director of the naval forces in Jeolla Jwasooyeong is known as the most popular Jangkei. "ChungMinKongKeicho" which has been re-located recently after loss is a national treasure level cultural property as valuable as "YimjinJangcho" and should be treated as a model of Yi Sun-sin's other Jangkeis by next generations. As of now, however it is not confirmed if it is a totally new book related to Yi Sun-sin or is supplementary to the lost Jangkei, this study decided to ascertain relevant information through a bibliographic discussion on the question. "Chungmin(忠愍)" was the title that was used after the death of Yi Sun-sin, and "ChungMinKongKeicho" was completed when Jangkei was copied in 1662. 12 books that would not be found in YimjinJangcho are included in the book and such books are also present in the Jangkei supplement which has been known lost so far. What should be especially focused on here is that the forms and contents of these (11) photographs that Japanese shot from "ChungMinKongKeicho" in 1928 turned out to be completely identical to those of the original copy. The point that Korean History Compilation Committee added the 12 books to Jangkei as referring to the book as "One Keicho(啓草) partially copied(抄寫) in separation" and that Cho Sung-do categorized the 12 books into a supplement and others can be solid proofs to make the Jangkei supplement called "ChungMinKongKeicho". In terms of "ChungMooKongKeicho", since it consists of 62 books in total, it is not reasonable to see the book as Jangkei supplement which has the extra 12 more books for itself. "ChungMooKongKeibon" in "ChungMooKongYusa" was written with a total of 16 books. In the body, Yidumun is only clearly present, and the three books in the later part are same with the original copy of "ChungMooKongKeicho". "YimjinJangcho" by Korean History Compilation Committee has been the only book in which Yidumun was observed so far but now, it is assumed that the publication date of "ChungMooKongKeibon" goes before that of the former. The counterargument to the opinion that "ChungMinKongKeicho" is the supplement to Jangkei is based on Lee Eun-sang's comment "One page of a log in the Jangkei copy supplement." At first Seol Ui-sik introduced a piece photo of the rough draft of "MoosulIlki" in a drawing form through "Nanjung Ilkicho by Yi Sun-sin" in 1953. Lee Eun-sang also added two pages of the handwritten Yilkicho in the Jangkeichobon supplement to "MoosulIlki" and for the second time, the phrase "One page of a log written during the last 10 days after the Jangkei copy supplement" and "Supplement" were used. Those views are originated from the comment "One photograph of the rough draft of "MoosulIlki"" which Seol Ui-sik introduced without knowledge of the exact source. Lee Eun-sang said, "One page of a log in the Jangkei copy supplement" because Lee mistook "ChungMooKongYusa" for a book related to Jangkei. Since it is the wrong argument different from the actual situation of the original copy, if it has to be corrected, it should be rephrased "One page of a log in ChungMooKongYusa." After all, the source of the counterargument is the mistake because there has never been the Jangkei supplement with one page of a log included. All the Jangkeis other than "YimjinJangcho" can be said as the Jangkei supplements but still, they are separated from the other Jangkeis for the extra 12 more books are present in the commonly-called Jangkei supplement. Due to that reason, the argument on how "ChungMinKongKeicho" with the 12 books added is the popular Jangkei supplement should be considered more reasonable.

Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy (가임기 여성의 방사선 치료 시 난소 선량 평가)

  • Park, Sung Jun;Lee, Yeong Cheol;Kim, Seon Myeong;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.145-153
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the ovarian dose during radiation therapy for breast cancer in women of childbearing age through an experiment. The ovarian dose is evaluated by comparing and analyzing between the calculated dose in the treatment planning system according to the treatment technique and the measured dose using a thermoluminescence dosimeter (TLD). The clinical usefulness of lead (Pb) apron is investigated through dose analysis according to whether or not it is used. Materials and Methods: Rando humanoid phantom was used for measurement, and wedge filter radiation therapy, 3D conformal radiation therapy, and intensity modulated radiation therapy were used as treatment techniques. A treatment plan was established so that 95% of the prescribed dose could be delivered to the right breast of the Rando humanoid phantom 3D image obtained using the CT simulator. TLD was inserted into the surface and depth of the virtual ovary of the Rando hunmanoid phantom and irradiated with radiation. The measurement location was the center of treatment and the point moved 2 cm to the opposite breast from the center of the Rando hunmanoid phantom, 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm from the boundary of the right breast to the center of treatment and downward, and the surface and depth of the right ovary. Measurements were made at a total of 9 central points. In the dose comparison of treatment planning systems, two wedge filter treatment techniques, three-dimensional conformal radiotherapy, and intensity-modulated radiation therapy were established and compared. Treatments were compared, and dose measurements according to the use of lead apron were compared and analyzed in intensity-modulated radiation therapy. The measured value was calculated by averaging three TLD values for each point and converting using the TLD calibration value, which was calculated as the point dose mean value. In order to compare the treatment plan value with the actual measured value, the absolute dose value was measured and compared at each point (%Diff). Results: At Point A, the center of treatment, a maximum of 201.7cGy was obtained in the treatment planning system, and a maximum of 200.6cGy was obtained in the TLD. In all treatment planning systems, 0cGy was calculated from Point G, which is a point 17.5cm downward from the breast interface. As a result of TLD, a maximum of 2.6cGy was obtained at Point G, and a maximum of 0.9cGy was obtained at Point J, which is the ovarian dose, and the absolute dose was 0.3%~1.3%. The difference in dose according to the use of lead aprons was from a maximum of 2.1cGy to a minimum of 0.1cGy, and the %Diff value was 0.1%~1.1%. Conclusion: In the treatment planning system, the difference in dose according to the three treatment plans did not show a significant difference from 0.85% to 2.45%. In the ovary, the difference between the Rando humanoid phantom's treatment planning system and the actual measured dose was within 0.9%, and the actual measured dose was slightly higher. This did not accurately reflect the effect of scattered radiation in the treatment planning system, and it is thought that the dose of scattered radiation and the dose taken by CBCT with TLD inserted were reflected in the actual measurement. In dosimetry according to the with or without a lead apron, when a lead apron was used, the closer the distance from the treatment range, the more effective the shielding was. Although it is not clinically appropriate for pregnancy or artificial insemination during radiotherapy, the dose irradiated to the ovaries during treatment is not expected to significantly affect the reproductive function of women of childbearing age after radiotherapy. However, since women of childbearing age have constant anxiety, it is thought that psychological stability can be promoted by presenting the data from this study.

A Review of Current Status and Placeness on the Yusang-Goksu Ruins in Hwanggak-dong, Geumma, Iksan (익산 금마 황각동 유상곡수 유적 일대의 현황과 장소성에 대한 일고찰)

  • Rho, Jae-Hyun;Han, Min-Soon;Seo, Youn-Mi;Park, Yool-Jin
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.40 no.3
    • /
    • pp.20-35
    • /
    • 2022
  • This study was conducted on the locational results of the 'Yusanggoksu(流觴曲水)' petroglyphs located in Hwanggak-dong(黃閣洞), Shinsong-ri, Geumma-myeon, Iksan-si through literature study, analysis of old maps and aerial photos, field observations, drone photography, elevation surveys, and interviews with residents. It was attempted for the purpose of illuminating and preserving the relics of the domestic Yusanggoksu garden by clarifying the spatiality of this place by tracing the spatiality and examining the possibility of enjoying the Yusanggoksu water system in this place. The conclusion of this study is as follows. The area around Hwanggak-dong, where the Yusanggoksu remains, has been selected as the most beautiful scenic spot in Iksan in various documents. The origin of 'Hwanggak' is considered to be closely related to the nickname of Uijeongbu(議政府). In other words, he paid attention to the relationship with Yanggok, So Se-yang(蘇世讓), who served as Chan-seong Jwa(左贊成). In particular, he paid attention to the relationship with his birthplace, Taeheojeong, a separate book, and Toehyudang, a retreat hall), tombs, and posthumous Confucian academies were distributed in the vicinity. Haseo-dae(荷鋤臺), a wide rock on which a hoe is hung on a rock after field work, seems to express a leisurely rural life and a simple and hermit life, based on the examples of Chinese and Korean poetry. The dark blood on the upper part of the Seobwi Rock with the inscription 'Yusanggoksu', which is the core of this site, is identified as a chailgong(遮日孔) to support the water system, and Ilgan-pavilion and Mojeong(茅亭) nearby are to support the yusanggoksu. It seems to have performed a spatial function for The inscription 'Hwanggak-dong' engraved on the front of Deungzanbawi is the gateway to Hwanggakdongcheon(黃閣洞天) and identified the idealized world existing in the village. Judging from the documentary records of the Iksan-gun 『Chongswaelog(叢瑣錄)』, the rock letters 'Hwanggak-dong' and 'Haseodae' were engraved on March 29, 1901, the 5th year of Gwangmu, the 5th year of the Korean Empire, by Iksan-gun Governor Oh Haeng-mook(吳宖默) and his acquaintance Seokseong Kim In-gil(金寅吉) Confirmed. Also, considering the tense of Lee Bong-gu's 「Hwanggakdongun(黃閣洞韻)」 and So Jin-deok, a descendant of Yanggok, 「Hwanggakdongsihoe(黃閣洞詩會)」, it is presumed that it was related to Goksuyeon(曲水宴) in Hwanggak-dong. It can be inferred that the current affairs meetings were held at least until the early days of Japanese colonial rule. Meanwhile, the maximum width of the current curved waterway was calculated as 11.3m and the transverse slope was 15.0%. If so, it is estimated that the width and extension distance of the curved waterway would have been much longer. Judging from the use of mochun(暮春), drinking and poetry, the tense 'Hwanggakdongsihoe' related to the Yusanggoksu relics in Hwanggak-dong, and the existence of a pavilion presumed to be Yusangjeong(流觴亭) called Ilgan-pavilion in the nearby Yusanggoksu site It is confirmed that it was a space where Yusanggoksuyeon(流觴曲水宴) spread at least until the end of the Joseon Dynasty. Unfortunately, it remains a limitation of the study that it cannot be confirmed due to lack of data on the rock characters of 'Yusanggoksu' and those who enjoyed it before the end of the Joseon Dynasty. This is an area that needs to be elucidated through continuous efforts to find data on this issue in the future.

Evaluating the usefulness of BinkieRTTM (oral positioning stent) for Head and Neck Radiotherapy (두경부암 환자 방사선 치료 시 BinkieRTTM(구강용 고정장치)에 대한 유용성 평가)

  • GyeongJin Lee;SangJun Son;GyeongDal Lim;ChanYong Kim;JeHee Lee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.21-30
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of oral positioning stent, the BinkieRTTM in radiation treatment for head and neck cancer patients in terms of tongue positions reproducibility, tongue doses and material properties. Materials and Methods: 24 cases using BinkieRTTM during radiation treatments were enrolled. The tongue was contoured on planning CT and CBCT images taken every 3 days during treatment, and then the DSC and center of tongue shift values were analyzed to evaluate the reproducibility of the tongue. The tongue dose was compared in terms of dose distribution when using BinkieRTTM and different type of oral stents (mouthpiece, paraffin wax). Randomly selected respective 10 patients were measured tongue doses of initial treatment plan for nasal cavity and unilateral parotid cancer. Finally, In terms of material evaluation, HU and relative electron density were identified in RTPS. Results: As a result of DSC analysis, it was 0.8 ± 0.07, skewness -0.8, kurtosis 0.61, and 95% CI was 0.79~0.82. To analyze the deviation of the central tongue shift during the treatment period, a 95% confidence interval for shift in the LR, SI, and AP directions were indicated, and a one-sample t-test for 0, which is an ideal value in the deviation(n=144). As a result of the t-test, the mean and SD in the LR and SI directions were 0.01 ± 0.14 cm (p→.05), 0.03 ± 0.25 cm (p→.05), and -0.08 ± 0.25 cm (p ←.05) in the AP direction. In the case of unilateral parotid cancer patients, the Dmean to the tongue of patients using BinkieRTTM was 16.92% ± 3.58% compared to the prescribed dose, and 23.99% ± 10.86% of patients with Paraffin Wax, indicating that the tongue dose was relatively lower when using BinkieRTTM (p←.05). On the other hand, among nasal cavity cancer patients, the Dmean of tongue dose for patients who used BinkieRTTM was 4.4% ± 5.6%, and for those who used mouthpiece, 5.9% ± 6.8%, but it was not statistically significant (p→.05). The relative electron density of Paraffin Wax, BinkieRTTM and Putty is 0.94, 0.99, 1.26 and the mass density is 0.95, 0.99 and 1.32 (g/cc), Transmission Factor is 0.99, 0.98, 0.96 respectively. Conclusion: The result of the tongue DSC analysis over the treatment period was about 0.8 and Deviation of the center of tongue shifts were within 0.2 cm, the reproducibility was more likely excellent. In the case of unilateral head and neck cancer patients, it was found that the use of BinkieRTTM rather than Paraffin Wax or Putty can reduce the unnecessary dose irradiated to the tongue. This study might be useful to understand of BinkieRTTM's properties and advantages. And also it could be another considered option as oral stent to keep the reproducibility of tongue and reducing dose during head and neck radiation treatments.