• Title/Summary/Keyword: 촬영계획

Search Result 466, Processing Time 0.026 seconds

Evaluation of the possibility of clinical application by surface dose measurement of ViewRay in MFW treatment (MFW 치료 시 ViewRay의 표면선량 측정에 따른 임상 적용 가능성 평가)

  • Sun, Geo Jun;Son, Sang Jun;Lee, Yang Hoon;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.169-176
    • /
    • 2018
  • Purpose : The purpose of this study is to evaluate clinical applicability of Co-60 ViewRay treatment plan to increase the skin dose in case of high skin dose is required such as Malignant Fungating Wound By measuring the presence / absence of Bolus application and skin dose by the treatment device and comparing it Materials and Methods : Nine inner measuring points of 2.5 cm lattice arrangement and all 13 measuring points including upper and lower left and right measuring points touching the chest and skin were marked. After CT was taken, each treatment plan was formulated through Eclipse and ViewRay-TPS, and a Fixed beam-IMRT treatment plan was formulated so that the left chest V2Gy=95 % is delivered. Before measurement QED detector was calibrated and the QED detector was positioned at the 13 measurement points displayed on Phantom and surface dose of each treatment planner was measured using 5 mm Bolus application using True-beam and View-ray before and after, measure three times and compare each before applying 5 mm Bolus. Results : The surface dose of the Co-60 ViewRay and the linear accelerator appeared at $76.8%{\pm}5.2%$ vs. $67.3{\pm}%7.5%$ and the surface dose after application of 5 mm Bolus was $87.6%{\pm}8.9%$ vs. $80.3%{\pm}10.2%$ It was measured at 10.2 % (p<0.001). Conclusion : As a result of the surface dose measurement of each treatment instrument, Co-60 ViewRay confirmed that the surface dose reached 95.6 % of 6 MV Linac with conventional 5 mm bolus, despite not using Bolus (p<0.001). Also, by utilizing magnetic resonance images for each treatment, it is possible to observe the change in the treatment site without the problem of exposure, it is easy to formulate an adaptive treatment plan and it is easy to secure the skin dose, so the size In the case of Malignant Fungating Wound patients who need fast skin changes and need high skin doses, Co-60 ViewRay is considered to be more useful than linear accelerators.

  • PDF

Usefulness of Abdominal Compressor Using Stereotactic Body Radiotherapy with Hepatocellular Carcinoma Patients (토모테라피를 이용한 간암환자의 정위적 방사선치료시 복부압박장치의 유용성 평가)

  • Woo, Joong-Yeol;Kim, Joo-Ho;Kim, Joon-Won;Baek, Jong-Geal;Park, Kwang-Soon;Lee, Jong-Min;Son, Dong-Min;Lee, Sang-Kyoo;Jeon, Byeong-Chul;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.157-165
    • /
    • 2012
  • Purpose: We evaluated usefulness of abdominal compressor for stereotactic body radiotherapy (SBRT) with unresectable hepatocellular carcinoma (HCC) patients and hepato-biliary cancer and metastatic liver cancer patients. Materials and Methods: From November 2011 to March 2012, we selected HCC patients who gained reduction of diaphragm movement >1 cm through abdominal compressor (diaphragm control, elekta, sweden) for HT (Hi-Art Tomotherapy, USA). We got planning computed tomography (CT) images and 4 dimensional (4D) images through 4D CT (somatom sensation, siemens, germany). The gross tumor volume (GTV) included a gross tumor and margins considering tumor movement. The planning target volume (PTV) included a 5 to 7 mm safety margin around GTV. We classified patients into two groups according to distance between tumor and organs at risk (OAR, stomach, duodenum, bowel). Patients with the distance more than 1 cm are classified as the 1st group and they received SBRT of 4 or 5 fractions. Patients with the distance less than 1 cm are classified as the 2nd group and they received tomotherapy of 20 fractions. Megavoltage computed tomography (MVCT) were performed 4 or 10 fractions. When we verify a MVCT fusion considering priority to liver than bone-technique. We sent MVCT images to Mim_vista (Mimsoftware, ver .5.4. USA) and we re-delineated stomach, duodenum and bowel to bowel_organ and delineated liver. First, we analyzed MVCT images to check the setup variation. Second we compared dose difference between tumor and OAR based on adaptive dose through adaptive planning station and Mim_vista. Results: Average setup variation from MVCT was $-0.66{\pm}1.53$ mm (left-right) $0.39{\pm}4.17$ mm (superior-inferior), $0.71{\pm}1.74$ mm (anterior-posterior), $-0.18{\pm}0.30$ degrees (roll). 1st group ($d{\geq}1$) and 2nd group (d<1) were similar to setup variation. 1st group ($d{\geq}1$) of $V_{diff3%}$ (volume of 3% difference of dose) of GTV through adaptive planing station was $0.78{\pm}0.05%$, PTV was $9.97{\pm}3.62%$, $V_{diff5%}$ was GTV 0.0%, PTV was $2.9{\pm}0.95%$, maximum dose difference rate of bowel_organ was $-6.85{\pm}1.11%$. 2nd Group (d<1) GTV of $V_{diff3%}$ was $1.62{\pm}0.55%$, PTV was $8.61{\pm}2.01%$, $V_{diff5%}$ of GTV was 0.0%, PTV was $5.33{\pm}2.32%$, maximum dose difference rate of bowel_organ was $28.33{\pm}24.41%$. Conclusion: Despite we saw diaphragm movement more than 5 mm with flouroscopy after use an abdominal compressor, average setup_variation from MVCT was less than 5 mm. Therefore, we could estimate the range of setup_error within a 5 mm. Target's dose difference rate of 1st group ($d{\geq}1$) and 2nd group (d<1) were similar, while 1st group ($d{\geq}1$) and 2nd group (d<1)'s bowel_organ's maximum dose difference rate's maximum difference was more than 35%, 1st group ($d{\geq}1$)'s bowel_organ's maximum dose difference rate was smaller than 2nd group (d<1). When applicating SBRT to HCC, abdominal compressor is useful to control diaphragm movement in selected patients with more than 1 cm bowel_organ distance.

  • PDF

Research on LOS Estimation Standard in the Mixed Traffic Street (보차혼용도로에서의 LOS 평가기준 마련에 관한 연구)

  • Kim, Suk-Hui;Kim, Gwan-Jung;Choe, Gi-Ju
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.3 s.89
    • /
    • pp.63-71
    • /
    • 2006
  • There were many theories to suggest the indicators that evaluate stability and reflect the plan in mixed traffic street in all traffic modes This Paper analyzed residential street of Suwon City adopting time-space occupancy index among these indicates. Three survey street. congregated into apartment house. were selected to analyze this and pictured by video camera over one hour. and the length of these street were 76m, 55m, and 34m each, and major street by each region, comparably high in Pedestrians and pass vehicles, were selected. Basic datum to calculate time-space occupancy index and time-space occupancy index per person was gathered through video analysis. i.e Parameters for pedestrians, cars, bicycles, average speed of bicycles, and parking car. There are some limitation to analyze LOS of mixed traffic street in all traffic modes, not pedestrian mall. Therefore this paper presented evaluation standard of LOS. In conclusion. the aim of this paper is to suggest modeling based on guidelines for evaluating LOS of mixed traffic street in all traffic modes. It is estimated that this will be influencing indicates for improving pedestrian environment, and Planning mixed traffic street in future.

A longitudinal study on the interrelationship between the growth change of the gonial ang1e and IMPA. (성장기 아동에 있어 gonial angle의 변화와 IMPA 변화에 관한 누년적 연구)

  • Chung, Chin Su;Ryu, Young-Kyu;Sohn, Byung-Wha;Kim, Young-Joon
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.435-443
    • /
    • 1999
  • This study was undertaken to investigate the growth change of genial angle and interrelationship between the growth change of gonial angle and IMPA in the longitudinal data from 7 years to 15 years. By analyzing the serial lateral cephalograms or 15 males and 19 females of 7 years old to 15 yens old who had no abnomality in growth and development and no history of orthodontic treatment, the following conclusion were obtained. 1. Genial angle gradually decreased with aging in 25 children and in 9 children increased or maintained. 2. There was a tendency that children who decreased genial angle with aging showed gradual increase of IMPA and children who increased or maintained gonial angle with aging showed decrease of IMPA. 3. There was a tendency that regardless of the change of gonial angle, interincisal angle decreased with aging.

  • PDF

The Influences of Lecture Design Using CoRe upon Professor's Teaching Professionalism in College of Science-Engineering (CoRe를 활용한 수업 설계가 이공계열 교수의 수업 전문성에 미치는 영향)

  • Song, Nayoon;Hong, Juyeon;Noh, Taehee;Han, JaeYoung
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.2
    • /
    • pp.84-98
    • /
    • 2020
  • In this study, we analyzed the influences of lecture design using CoRe upon the professor's teaching professionalism in the aspects of pedagogical content knowledge (PCK). The participants are three professors from the college of science-engineering located in Chungcheong-do. After collecting their syllabi, we observed their lecture and conducted the orientation. Afterward, we collected the CoRes which they prepared before the lecture. Then we observed their lecture and conducted semi-structured interviews. This process was carried out twice. We analyzed their syllabi, CoRes, videotaped lectures, field notes, the teaching materials, and interview transcripts. The results revealed that professors not only clarified the learning objectives and the characteristics of students but also reflected them in the lecture. In addition, they established the teaching strategies according to the characteristics of contents in the unit. As they recognized the necessity of understanding students' achievement, they selected the assessment method and applied it in the lecture. In some cases, however, they lacked presenting learning objectives specifically and explained students' misconceptions without inducing new concepts. They also presented a shortage of considering students' prior knowledge. They lacked providing students with an opportunity to participate in lectures, and their assessment method was not effective. Based on the results, we discussed implications to improve teaching professionalism using CoRe.

A Case Study on the Use of Mentoring as a Method of Improving Novice Teachers' Teaching Professionalism in Secondary Science-Gifted Education (중등 과학영재교육에서 초임 교사의 수업 전문성 제고 전략으로써의 멘토링 적용 사례연구)

  • Noh, Tae-Hee;Kang, Seok-Joo;Kang, Hun-Sik
    • Journal of The Korean Association For Science Education
    • /
    • v.32 no.2
    • /
    • pp.331-345
    • /
    • 2012
  • As a case study on the use of mentoring as a method of improving novice teachers' teaching professionalism in secondary science-gifted education, this study investigated the characteristics of mentoring science instructions for science-gifted students at the plan, performance, evaluation, and post-mentoring stages of the classes. One mentor and two mentees were selected, and mentoring in each mentee's instructions was conducted during nine classes over three times. We observed the total classes, and analyzed taped videos, the materials, the transcripts for mentoring and in-depth interviews, and field notes. The analyses of the results indicated that the characteristics of mentoring instructions, at the planning stage of the classes, exhibited the construction of more systematic classes, the escape from the schema that science instructions for science-gifted students were instructions using somewhat difficult experiments and the uses of diverse teaching strategies, the influence of the psychological burdens on developing science-gifted education programs, and the increase of the time preparing the classes. At the performance stage of the classes, the characteristics included the improvement in the quality of the classes, the influence of the psychological burdens on teaching the classes, and the inducements of some confusion on performing them. At the evaluation stage of the classes, the characteristics included the provision of the opportunities in deeply reflecting my own classes, and the provision of the practical power for improving the classes. Finally, the characteristics at the postmentoring stage could be attributed to the increase of mentees' self-confidence about their instructions and some development of mentors' teaching professionalism/mentoring skills.

Determination of Tumor Volume in PET for the Radiation Treatment Planning: Computer Simulation (방사선치료계획을 위한 PET 종양용적 결정 연구: 컴퓨터 모의실험)

  • Yoon Seok Nam;Joh Chul-Woo;Lee Jae Sung
    • Progress in Medical Physics
    • /
    • v.16 no.4
    • /
    • pp.183-191
    • /
    • 2005
  • The utilization of PET has been increased so fast since the usefulness of the PET has been proved in various clinical and research fields. Among the many applications, the PET Is especially useful in oncology and most of the clinical PET scans are peformed for the oncologic examination Including the different diagnosis of malignant and benign tumors and assessment of the treatment effects and recurrent tumors. As the PET-CT scanners are widely available, there is Increasing interest in the application of the PET Images to the radiation treatment planning. Although the CT images are conventionally used for the target volume determination in the radiation treatment planning, there are fundamental limitation In use of only the anatomical information. Therefore, the volume determination of the functionally active tumor region using the PET would be important for the treatment planning. However, the accurate determination of the tumor boundary is not simple in PET due to the relatively low spatial resolution of the currently available PET scanners. In this study, computer simulations were peformed to study the relationship between the lesion size, PET resolution, lesion to background ratio and the threshold of Image Intensity to determine the true tumor volume.

  • PDF

A Study on the Analysis Technique of Sequence Landscaping through the Application and Development of Visual Amount Calculation Program of Landscapes (경관의 시각량 산출 프로그램 개발과 적용을 통한 연속경관 시퀀스 분석기법 연구)

  • Koo, Min-Ah
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.5
    • /
    • pp.12-25
    • /
    • 2016
  • In this study, in order to facilitate analysis in a continuous sequence, including the concept of the landscape experience time, countless frames of a continuous landscape were extracted. The amount of visual elements in each frame was data-converted numerically to take advantage of the quantitative data necessary for landscape planning and design was calculated in the rhythm of the sequence. In Order to shoot video with the flow of the line of sight of experience in landscape districts and landscape control points along the landscape corridor which is a continuous path, each of the corresponding computer motion techniques. This study developed a CRVP Koo computer program to effectively calculate the continuous visual number of specific landscape components by extracting uncounted frames at regular intervals, and after verifying, attempting to apply this to the target site. Through the applied result, it was possible to extract the digitized quantitative rhythm for each component of each landscape, the margin of error is very small when compared with the results of manual in photoshop, it was able to overcome the drawbacks of the manual. Using the rhythm of the derived sequence, and those close to the experience of the landscape, it was possible to achieve quantitative analysis derived from a variety of perspectives as well as was possible to be used as quantitative basis data and analysis technique for landscape planning and design.

A Study on the Analysis of Visibility between a Lunar Orbiter and Ground Stations for Trans-Lunar Trajectory and Mission Orbit (지구-달 전이궤적 및 임무 궤도에서 궤도선과 지상국의 가시성 분석에 관한 연구)

  • Choi, Su-Jin;Kim, In-Kyu;Moon, Sang-Man;Kim, Changkyoon;Rew, Dong-young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.3
    • /
    • pp.218-227
    • /
    • 2016
  • Korean government plans to launch a lunar orbiter and a lander to the Moon by 2020. Before launch these two proves, an experimental lunar orbiter will be launched by 2018 to obtain key space technologies for the lunar exploration. Several payloads equipped in experimental lunar orbiter will monitor the surface of the Moon and will gather science data. Lunar orbiter sends telemetry and receives tele-command from ground using S-band while science data is sent to ground stations using X-band when the visibility is available. Korean deep space network will be mainly used for S and X-band communication with lunar orbiter. Deep Space Network or Universal Space Network can also be used for the S-band during trans-lunar phase when korean deep space network is not available and will be used for the S-band in normal mission orbit as a backup. This paper analyzes a visibility condition based on the combination of various ground antennas and its mask angles according to mission scenario to predict the number of contacts per day and to build an operational scenario for the lunar orbiter.

Esophageal Steno-Obstruction due to Nonesophageal Tumors (비식도 종양에 의한 식도의 협착 및 폐쇄)

  • Oh Yoon Kyeong;Gil Hak Jun;Chung Soo Mi;Yoon Sei Chul;Shinn Kyung Sub;Bahk Yong Whee
    • Radiation Oncology Journal
    • /
    • v.5 no.2
    • /
    • pp.111-117
    • /
    • 1987
  • From March, 1983 to March, 1987, 16 patients with esophageal steno-obstruction due to nonesophageal tumors were treated in the Division of Therapeutic Radiology, Kangnam St. Mary's Hospital, Catholic University Medical College. The patient characteristics, effect of radiotherapy (XRT) on esophageal steno-obstruction and survival were evaluated. The most common primary tumor was lung cancer (14/16) and the middle third of the esophagus was most frequently involved (14/16). Improved clinical response was observed in $80\%$ of the patients who finished the planned courses of XRT. The mean radiation dose evoking the improvement of dysphagia was 2,993 cGy given over a period of 3 to 4 weeks. The Kaplan-Meier estimates of survival at 15 and 30 weeks of follow-up were $60\%$ and $46\%$, respectively. In the completed group who finished the whole planned courses of XRT, survival rates were $77\%\;and\;51\%$, respectively. Four patients were alive over 90 weeks with normal passage of food.

  • PDF