• Title/Summary/Keyword: 초음파 세기

Search Result 90, Processing Time 0.034 seconds

The Evaluation Technique of Surface Region using Backward-Radiated Ultrasound (후방 복사된 초음파를 이용한 표면 지역의 평가 기술)

  • Kwon, S.D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.4
    • /
    • pp.241-250
    • /
    • 1997
  • The velocity dispersion of surface acoustical wave(SAW) of Si layer/mesh Au/Si substrate was measured by the frequency analysis technique of backward radiation at liquid/solid interface. The difference of backward radiation patterns depending on used transducers (2, 5, 10MHz) confirmed that the backward radiation phenomenon was caused by the energy radiation from SAW generated in surface region. An ultrasonic goniometer was constructed to measure continuously the angular dependence of backscattered intensity. The angular dependences of backward radiation(5MHz) were measured for Ni layer/Al substrate specimens that were bonded by epoxy involving different content of Cu powder. It was known that the width and pattern of backward radiation had informations such as the velocity dispersion, bonding quality and structure of surface region.

  • PDF

Sono-electrochemical Determination of Uric Acid (요산의 초음파 전기화학적 정량)

  • Cho Hyung-hwa;Bae Zun-ung
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.4
    • /
    • pp.232-234
    • /
    • 2000
  • Determination of uric acid by electrochemical method using ultrasonic stimulation has been investigated. Effects of sonication power, sonication time, pH of the solution and temperature were studied to obtain the optimal analytical conditions. The stability of the electrode was also examined. The optimal conditions for the sonovoltammetric determination of uric acid were as follows: temperature, $25.0^{\circ}C$ pH 7.0; sonication power, $20W/cm^2$. The calibration curve for the determination of uric acid by sono-LSV was linear over the range of$8.0{\times}10^{-6}\~5.0\times10^{-4}M$ and the limit of detection was $6.5\times10^{-6}M$.

Ultrasonic Backscattering on Painted Rough Surface at near Rayleigh Angle (레일리각 근처에서 도색된 거친 표면으로부터 후방 산란된 초음파)

  • Kwon, Sung-D.;Kwon, Yong-G.;Yoon, Seok-S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • The angular dependence (or profile) of backscattered ultrasound was measured for steel specimens with a range of surface roughness, $1{\sim}71{\mu}m$. Backscattering profiles at or near the Rayleigh angle still showed roughness dependence while the assessment of surface roughness via normal profile became impossible due to the paint layer masking the roughness. The peak amplitude directly radiated at the Rayleigh angle was proportional to the surface roughness, while the averaged peak amplitude radiated from the backward propagating Rayleigh wave, produced by reflection at a corner, was inversely proportional. In the painted specimens, the linearity of direct backward radiation with the roughness was observed even at the roughness of less than three hundredths of a wavelength, and the abnormal multiple bark reflection caused by periodic roughness disappeared.

Effects of sonication on physicochemical properties and pore formation of maize starch (초음파처리가 옥수수전분의 이화학특성과 기공 형성에 미치는 영향)

  • Choi, Eun-Hee;Lee, Jae-Kwon
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.5
    • /
    • pp.507-512
    • /
    • 2017
  • The physicochemical properties of maize starch sonicated at various amplitudes (100, 200, and 300 W) and times (10, 30, and 50 min) were examined. The amount of enzyme-susceptible starch increased marginally after sonication. Sonication increased the amount of oil absorbed in the starch although the degree of oil absorption decreased with an extension of the sonication time, implied that different types and extent of damages occurred. Scanning electron microscopy revealed that ultrasound sonication did not form pores on the surfaces, but caused damages such as depression and erosion. Pasting viscosity of starch decreased with an increase in the severity of sonication conditions because of the weakened polymer network. X-ray diffraction suggested that the crystalline domains in starch were not susceptible to sonication and were more resistance to degradation. Sonicated starch formed more pin-holes on the surfaces in the initial glucoamylase reaction; subsequently, as the reaction proceeded, porous starch with enlarged pores was formed and finally, disrupted granular fragments were observed.

Simulations for Internal Defect Inspection Using Laser Generated Ultrasonic Wave in Ablation Regime (어블레이션 영역 레이저 초음파의 시뮬레이션과 내부결함 검사)

  • Kim, Jin-Gyum;Choi, Sungho;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.3
    • /
    • pp.226-232
    • /
    • 2014
  • In the present study, the characteristics of laser ultrasound in the ablation regime are investigated using simulations and experiments. The laser ultrasonic technique has been recognized as a noncontact method in the field of nondestructive tests (NDTs). In hostile environments (such as hot temperatures), this method has various advantages over the conventional contact ultrasonic method. In particular, in the ablation regime, the laser ultrasonic technique is suitable for inspecting internal defects because of the high amplitude and directivity of the longitudinal wave. In this paper, a simulation model for laser ultrasound in the ablation regime was developed. This model was subsequently applied to a defective specimen using the B-scan method to locate defects. Finally, we performed an experimental test to verify the simulation results. Consequently, the simulation demonstrated good agreement with the experimental test.

Study of Acoustic Streaming at Resonance by Longitudinal Ultrasonic Vibration Using Particle Imaging Velocimetry (입자 영상 유속계를 이용한 초음파 수직진동에 의해 유도된 공진상태에서의 음향유동에 관한 연구)

  • 노병국;이동렬
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.5
    • /
    • pp.340-352
    • /
    • 2004
  • Acoustic streaming induced by the microscopic longitudinal ultrasonic vibration at 28.5 ㎑ is visualized between the quiescent glass plate and ultrasonic vibrator by particle imaging velocimetry(PIV) using laser. To investigate the augmentation of air flow velocity of acoustic streaming. the velocity variations of air streaming between the stationary plate and ultrasonic vibrator are measured in real-time. It is experimentally investigated that the magnitude of the acoustic streaming dependent upon the gap between the ultrasonic vibrator and stationary p1ate results in the variations of the average velocity fields as a outcome of the bulk air flow caused by the ultrasonic vibration. In addition. maximum acoustic streaming velocity exists at resonant gap. 18mm that is one of the resonant gaps (H=18, 24, 30, 36㎜) at which resonance occurs. The variation of the local maximum turbulent intensity with axial direction appear to reveal the value of 8%∼70% dependent upon the gap between the quiescent glass plate and ultrasonic vibrator. Shearstress is also maximized at the center region of the vibrator and the vorticity is also maximum and minimum in the neighborhood of the center of the vibrator at which the local maximum turbulent intensity and shear stress exist.

Development of a Laser-Generated Ultrasonic Inspection System by Using Adaptive Error Correction and Dynamic Stabilizer (적응적 에러 보정과 다이나믹 안정기를 이용한 레이저 유도 초음파 검사 시스템 개발)

  • Park, Seung-Kyu;Baik, Sung-Hoon;Park, Moon-Cheol;Lim, Chang-Hwan;Ra, Sung-Woong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.5
    • /
    • pp.391-399
    • /
    • 2005
  • Laser-generated ultrasonic inspection system is a non-contact scanning inspection device with high spatial resolution and wide bandwidth. The amplitude of laser-generated ultrasound is varied according to the energy of pulse laser and the surface conditions of an object where the CW measuring laser beam is pointing. In this paper, we correct the generating errors by measuring the energy of pulse laser beam and correct the measuring errors by extracting the gain information of laser interferometer at each time. h dynamic stabilizer is developed to stably scan on the surface of an object for an laser-generated ultrasonic inspection system. The developed system generates ultrasound after adaptively finding the maximum gain time of an laser interferometer and processes the signal in real time after digitization with high speed. In this paper, we describe hardware configuration and control algorithm to build a stable laser-generated ultrasonic inspection system. Also, we confirmed through experiments that the proposed correction method for the generating errors and measuring errors is effective to improve the performance of a system.

Improvement of Fouling in Membrane Separation Process for Leachate Treatment using Ultrasound(I) : Analysis of Ultrasonic Parameters (초음파를 이용한 침출수 처리를 위한 막분리 공정의 막힘현상 개선(I) : 초음파의 영향인자 평가)

  • Kim, Seok-Wan;Lim, Jae-Lim;Lee, Jun-Geol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.197-206
    • /
    • 2006
  • This study evaluated the effect of ultrasonic irradiation on improving the flux and cleaning efficiency in membrane process which is widely applied for the treatment of landfill leachate. The experiments on improvement of membrane flux according to the types of membranes(hallowfiber microfiltration, MF and tubular ultrafiltration, UF) were performed with changing frequency($40{\sim}120$ kHz), intensity ($200{\sim}500$ W) and irradiation time of ultrasound as well us operation pressure($0.1{\sim}2.3kg/cm^2$). Membrane was fouled for the first 50 min with primary treated leachate and then the change in flux according to ultrasonic irradiation period was observed for 70 min. Parameters influenced to the recovery ratio corresponding the net flux on pure water and to the enhancement ratio applied after ultrasonic irradiation on the flux were analyzed. In same condition, the flux was improved in proportion to ultrasonic intensity while the improvement of flux was inversely proportional to ultrasonic frequency. The cleaning effect of membrane was delayed and reduced when operation pressure of membrane was high. The recovery ratio and enhancement ratio for $0.1{\mu}m$ MF membrane were 10% and 500%, respectively while those were maximized at $75{\sim}98%\;and\;40{\sim}50%$ for UF membrane for 10,000 and 100,000 MWCO, respectively. In conclusion, it was confirmed that ultrasonic cleaning using mechanical vibration is alternative to water or chemical cleaning for improving membrane flux.

A Study to Recover Si from End-of-Life Solar Cells using Ultrasonic Cleaning Method (초음파 세척법을 이용한 사용 후 태양광 셀로부터 Si 회수 연구)

  • Lee, Dong-Hun;Go, Min-Seok;Wang, Jei-Pil
    • Resources Recycling
    • /
    • v.30 no.5
    • /
    • pp.38-48
    • /
    • 2021
  • In this study, we determine the optimal process conditions for selectively recovering Si from a solar cell surface by removal of impurities (Al, Zn, Ag, etc.). To selectively recover Si from solar cells, leaching is performed using HCl solution and an ultrasonic cleaner. After leaching, the solar cells are washed using distilled water and dried in an oven. Decompression filtration is performed on the HCl solution, and ICP-OES (Inductively Coupled Plasma Optical Emission spectroscopy) full scan analysis is performed on the filtered solution. Furthermore, XRD (X-ray powder diffraction), XRF (X-ray fluorescence), and ICP-OES are performed on the dried solar cells after crushing, and the purity and recovery rate of Si are obtained. In this experiment, the concentration of acid solution, reaction temperature, reaction time, and ultrasonic intensity are considered as variables. The results show that the optimal process conditions for the selective recovery of Si from the solar cells are as follows: the concentration of acid solution = 3 M HCl, reaction temperature = 60℃, reaction time = 120 min, and ultrasonic intensity = 150 W. Further, the Si purity and recovery rate are 99.85 and 99.24%, respectively.

Multi-element Ultrasound Applicator for the Treatment of Cancer in Uterus and Cervix (자궁암 치료용 다채널 초음파 온열치료기)

  • Lee Rena
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.16-23
    • /
    • 2005
  • The objective of this study was to construct multi-element ultrasound applicators for the treatment of gynecologic cancer with high dose rate brachytherapy. For the treatment of uterus, piezo-ceramic crystal transducer (PZT -5A) with outer diameter of 4 mm, wall thickness of 1.3 mm, and length of 24.5 mm was selected. For the treatment of cervix or vagina, it should be possible to insert the applicator into the vagina. Thus, a cylindrical PZT -8 material with outer diameter of 24.5 mm, wall thickness of 1.3 mm, and length of 15.2 mm was selected. The operating frequencies determined by vector impedance measurement were 3.2 MHz for the PZT 5A cylinder (OD=4 mm) and 1.7 MHz for the PZT -8 cylinder (OD: 24.5 mm). The ratios of generated acoustic output power to applied electric power were 33% and 61% for the tandem type crystal and the cylinder type crystal, respectively. The radiated acoustic pressure fields from both transducers were calculated using a Matlab code and measured in water using hydrophone. There was good agreement between measured and calculated acoustic pressure field distribution. For a tandem type transducer, the calculated acoustic pressure field decreased from 0.023 MPa at 10 mm to 0.010 Mpa at 30 mm, the reduction of 57%. For the cylinder type transducer which will be used for the treatment of vagina showed 78% reduction at 15 mm and 66% at 25 mm as compared to values at 5 mm from the surface. Based on the characteristics of the transducers, this study demonstrated the possibility of using the crystals as a heating source. Finally, a 3-element and 4-element prototype applicators were constructed. The 3-element applicator is 75 mm long and 4 mm thick and will be used for the treatment of uterus. The 4-element applicator is 61 mm long and 24.5 mm thick and will be used for the treatment of vagina. Using these applicators, it is possible to generate enough power to increase temperature to therapeutic level.

  • PDF