• Title/Summary/Keyword: 초음파 발생장치

Search Result 153, Processing Time 0.025 seconds

A Study on Improvement of Parking Guidance System to Low-Power Operation for Green Building

  • Lee, Jeong-Jun;Oh, Young-Tae;Lee, Choul-Ki;Yun, Il-Soo;Chung, Sang-Ho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.3
    • /
    • pp.1-8
    • /
    • 2011
  • The parking guidance system can increase driver's convenience with detailed parking information service, but it continuously consumes electrical energy with large amount of sensors, displays and control modules. With the increase of the demand for green and sustainable building design, it becomes a meaningful issue for parking guidance system to reduce operating power. This paper presents the preliminary design and estimated results of a parking guidance system which is optimized to reduce the power consumption mainly on detectors and displays. The system design is based on commercial wireless parking detectors, wireless-loop-detector and earth-magnetic-detector. We have performed system architecture design, communication network design, parking information service scenario planning, battery life regulation and at last operating power estimation. With the 7 years of battery replace cycle, the estimated result for power consumption of designed system was 0.33W/slot, which is 13% of the traditional system's estimation result. The estimated annual maintain cost was similar to the traditional ultrasonic sensor based system's. The low power operable designed system can be expected to reduce CO2 emission.

A Study on the Quality Control of Transvaginal Ultrasound Transducer using ATS-539 Ultrasound Phantom (ATS-539 초음파 팬텀을 이용한 경질 초음파 검사용 탐촉자의 정도관리에 대한 연구)

  • Park, Ji Hye;Heo, Yeong Cheol;Kim, Yon min;Han, Dong Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.463-472
    • /
    • 2021
  • Demand for examinations using transvaginal transducer with high frequencies is increasing to observe pelvic organs in gynecological ultrasound tests. However, the quality control of the replacement probe in clinical trials is not properly implemented and the evaluation criteria have not been established. Therefore, 58 transvaginal transducers and 20 convex transducers were applied to the ATS-539 ultrasound phantom for 20 ultrasound devices currently in clinical use to obtain their respective images and measure them quantitatively and qualitatively. For quantitative measurements, vertical measurement, horizontal measurement, and focal zone and qualitative measurements, dead zone, axial·lateral resolution, sensitivity, functional resolution, gray scale·dynamic range were performed. Quantitative statistical analysis showed significant differences between the two transducers in the lateral measurement and local area (p<0.05). qualitative comparative analysis showed differences in sensitivity and functional resolution. This occurs due to the difference in frequency between transducers and the transducer's injection geometry. Based on the above experiments, the tolerance for horizontal measurement is raised to 10% (±8 mm), the tolerance for sensitivity is observed up to 6 cm deep, which is 12 cm deep,which is the level of the third quartile (75%). The permissible range of functional resolution is up to 6 (12 cm), 6 (12 cm), 11 (11 cm), 9 (9 cm), 6 (6 cm) target, which is the level of the third quartile (75%). It is considered reasonable to adjust the depth of targets in gray scale·dynamic range to measure at a depth of 2 cm, which is 50% of the depth of 4 cm. As above, the criteria for evaluating the quality of transvaginal transducer for use in the past have been proposed and it is expected that this study will be used as a basic data for the production of phantom exclusively for transvaginal transducer in the future.

아크로 증착된 TiN 박막의 특성 연구

  • Jang, Seung-Hyeon;Yang, Ji-Hun;Park, Hye-Seon;Jeong, Jae-In
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.177-177
    • /
    • 2010
  • 티타늄 화합물은 뛰어난 물리적 특성과 인체 무해성을 가지고 있어 생체, 내식 및 내마모 재료 등에 널리 응용되고 있으며, 다양한 색상 구현을 통한 미려한 외관 등 기능성을 위한 표면처리 분야에도 많은 관심을 받고 있다. 이중 질화 티타늄은 금색을 대체할 수 있는 물질로 코팅방법과 기판온도, 바이어스, 질소유량 등과 같은 공정변수 제어를 통해 그 물성을 변화시킬 수 있어 기능적 측면과 함께 미려한 외관처리에 응용이 가능하다. 본 연구에서는 아크(cathodic arc) 코팅 시스템을 이용하여 다양한 조건에서 TiN 박막을 제조하고 그 특성을 평가하였다. 아크 장비는 화합물 박막을 코팅할 수 있는 아크 소스와 시편 홀더, 가스 주입구, 시편 가열장치 그리고 배기 장치로 구성되어 있고, 아크 소스에 장착된 타겟은 99.5%의 Ti 타겟을 사용하였다. 시편과 타겟 간의 거리는 약 31cm이며, 시편은 알코올과 아세톤으로 초음파 세척 된 강판(냉연 강판), 실리콘 웨이퍼를 사용하였다. 시편을 진공용기에 장착하고 ${\sim}10^{-6}$ Torr까지 진공배기를 실시하고, Ar 가스를 진공용기 내로 공급하여 ${\sim}10^{-4}$ Torr에서 시편에 bias (Pulse : 400V)를 인가한 후 아크를 발생시켜 약 5분간 청정을 실시하였다. 플라즈마 청정이 끝나면 시편에 인가된 bias를 차단하고, 질소 유량, 온도, bias, 시간 등의 공정변수에 따라 코팅을 실시하였다. 질소의 유량이 80sccm 일 때, Ti 금속 결정구조가 나타났는데, 이는 질소와 충분하게 반응하지 못한 Ti이 기판에 코팅되어 나타나는 현상으로 판단된다. 색상변화에서는 질소 유량이 증가함에 따라 노란색이 짙어지며, TiN은 시편에 인가되는 bias 전압이 높아질수록 붉은색이 증가하고, 온도에 따른 큰 변화는 관찰되지 않았다. 공정변수에 따른 반사율 변화는 TiN의 경우 질소 가스 유량이 200sccm, bias 150V, 공정 온도 200도에서 반사율이 가장 높았으며, 코팅 시간이 짧을수록 반사율이 높아지는 경향을 나타냈다. 따라서 본 연구에서 얻어진 결과를 외관 코팅 분야에 응용한다면 장식성과 외관의 경도, 내마모성, 내식성의 향상 등 많은 장점을 가질 것으로 예상된다.

  • PDF

Design method of Top-down fog screen (하향식 포그 스크린 설계 방법)

  • Park, Yoenyong;Jung, Moonryul
    • Journal of the Korea Computer Graphics Society
    • /
    • v.25 no.3
    • /
    • pp.31-41
    • /
    • 2019
  • A fog screen consists of tiny water drops and the viewers see the image transmitted through the fog screen. In contrast to ordinary screens, the viewers can see the actors passing through the image on the fog screen on stage. In this paper, we describe methods to build a top-down fog screen where fog particles generated in top space fall by gravity forming a flat vertical screen. We use a fog generation technique in which fog particles come out of the water surface when ultrasound vibrators immersed in water tank vibrate. We describe how fog particles form a flat screen while coming out of the fog passage tunnel, by generating guiding winds beside the fog screen. This technique utilizes the principle that fog particles are generated on the surface of a water tank by an ultrasonic vibrator placed in a water tank. The technique of forming a guiding wind on both sides of the passage exit where the fog comes out and the design and manufacturing method of the fog screen generating device are described so that the generated fog group can maintain one plane.

A Study on portable voice recording prevention device (휴대용 음성 녹음 방지 장치 연구)

  • Kim, Hee-Chul
    • Journal of Digital Convergence
    • /
    • v.19 no.7
    • /
    • pp.209-215
    • /
    • 2021
  • This study is a system development for voice information protection equipment in major meetings and places requiring security. Security performance and stability were secured with information leakage prevention technology through generation of false noise and ultrasonic waves. The cutoff frequency band for blocking the leakage of voice information, which has strong straightness due to the nature of the radio wave to the recording prevention module, blocks the wideband frequency of 20~20,000Hz, and the deception jamming technology is applied to block the leakage of voice information, greatly improving the security. To solve this problem, we developed a system that blocks the recording of a portable smartphone using a battery, and made the installation of a separate device smaller and lighter so that customers do not recognize it. In addition, it is necessary to continuously study measures and countermeasures for efficiently using the output of the anti-recording speaker for long-distance recording prevention.

Study on the Nonlinear Electromagnetic Acoustic Resonance Method for the Evaluation of Hidden Damage in a Metallic Material (금속 재료의 잠닉손상 평가를 위한 비선형 전자기음향공진 기법에 관한 연구)

  • Cho, Seung-Wan;Cho, Seung-Hyun;Park, Choon-Su;Seo, Dae-Cheol;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.4
    • /
    • pp.277-282
    • /
    • 2014
  • Recently, much attention has been paid to nonlinear ultrasonic technology as a potential tool to assess hidden damages that cannot be detected by conventional ultrasonic testing. One nonlinear ultrasonic technique is measurement of the resonance frequency shift, which is based on the hysteresis of the material elasticity. Sophisticated measurement of resonance frequency is required, because the change in resonance frequency is usually quite small. In this investigation, the nonlinear electromagnetic acoustic resonance (NEMAR) method was employed. The NEMAR method uses noncontact electromagnetic acoustic transducers (EMATs) in order to minimize the effect of the transducer on the frequency response of the object. Aluminum plate specimens that underwent three point bending fatigue were tested with a shear wave EMAT. The hysteretic nonlinear parameter ${\alpha}$, a key indicator of damage, was calculated from the resonance frequency shift at several levels of input voltage. The hysteretic nonlinear parameter of a damaged sample was compared to that of an intact one, showing a difference in the values.

Comparisons of Sludge Pre-Treatment Systems : Hydrodynamic vs Ultrasonic Cavitation (수리동력학적 및 초음파 캐비테이션 슬러지 전처리 장치의 비교 연구)

  • Maeng, Jang-Woo;Bae, Jae-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.2
    • /
    • pp.90-95
    • /
    • 2009
  • Sludge pre-treatment utilizing cavitation is one of the commercialized methods at present. Cavitation can be generated by two different methods, sonotrode and hydrodynamic principle, and there has been no direct comparison between the two methods. In this study, solubilization efficiency, changes in sludge size distribution, and the methane production potential after pre-treatment by the two methods were compared. The maximum solubilization efficiency per unit energy input with the two methods was similar, and was 302 mg ${\Delta}SCOD/g$ TS at the energy input of 0.18 kWh/L. Break-up of sludge flocs were dominant during the early period of pre-treatment, while cell disintegration continued through the pre-treatment with the increase in the number of particles with less than 1 ${\mu}m$. BMP test results indicated that the methane potential increased up to 24.3% without differences between the two pre-treatments, and the increase in methane potential did not proportional to energy input. Although the energy efficiency of the two methods was quite similar, hydrodynamic methods might be a better choice for field application considering the operation and maintenance cost, and its potential improvement in energy efficiency.

The Study on the Factors for Detection of Renal Stone on Ultrasound (초음파 검사에서 신장 결석의 검출 요인에 관한 연구)

  • Sim, Hyun-Sun;Jung, Hong-Ryang;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • Purpose: Renal stones are common and typically arise within the collecting system. The renal sinus are contains the collection system, the renal vessels, lymphatcs, fat, and fibrous tissue. Because of the compression of all the large echoes in signal processing, the echo from the renal stone generally cannot be distinguished from large echoes emanating from normal structures of the renal sinus. Use of ultrasonography has been difficult for detecting small renal stone without posterior shadowing and chemical composition of stone. The aim of study was measuring for posterior acoustic shadowing to a stone for various scan parameter and it examines a help in renal stone diagnosis. Material & Methods: The stone was place on sponge examined in a water bath with a 3.5MHz or 7.5MHz transducer(LOGIQ 400, USA). First, tested a variety of gain. Second, tested a variety of dynamic range. Third, tested a variety of focal zone. Fourth, measuring of the echo level for low and high frequency for depth. Results: 1) Average echo level was 98 for low total gain(10 dB) and was 142 for high total gain(40 dB). Posterior acoustic shadowing of renal stone was clear for low gain. 2) Average echo level was 129 for low dynamic range(42 dB) and was 101 for high dynamic range(72 dB). Posterior acoustic shadowing of renal stone was clear for high dynamic range. 3) When stone is in focal zone of transducer, definite posterior acoustic shadow is identified. 4) Stone was clear appeared for high frequency(7.5 MHz) than low frequency(3.5 MHz) and it is not distorted. Conclusion: The demonstration of an posterior acoustic shadow of renal stone dependents on several technical factors such as gain, dynamic range, focus, and frequency. This various factors are a help in renal stone diagnosis.

  • PDF

A Machine-to-machine based Intelligent Walking Assistance System for Visually Impaired Person (시각장애인을 위한 M2M 기반의 지능형 보행보조시스템)

  • Kang, Chang-Soon;Jo, Hwa-Seop;Kim, Byung-Hee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.3B
    • /
    • pp.287-296
    • /
    • 2011
  • The white stick mainly used for visually impaired person has difficulty in providing location information and effective countermeasures for emergency situations encountered during walking as well as detecting floating obstacles on the ground. In this paper, we propose a machine-to-machine based intelligent walking assistance system for safe and convenient walking of the visually impaired. The proposed system consists of a walking assistance stick used by the visually impaired and a server supporting multiple stick users in remote places through mobile communication networks. The stick equipped with ultrasonic sensors, GPS(global positioning system) receiver and vibrator not only detects floating obstacles, but also offers stick users with present location identification utilizing a text-to-voice conversion technology. Besides providing geographic information, the server notifies the emergency locations of users to guardian and aid agency, and it provides log information during walking such as the place, time and the number of accidents. Test results with a developed prototype system have shown that the system properly performs the functions and satisfies overall system performance.

Evaluation of the Effect of Location and Direction of the Scoliotic Curve on Postural Balance of Patients with Idiopathic Scoliosis (특발성 척추측만증 환자의 척추 만곡 위치와 방향이 자세 균형에 미치는 영향성 평가)

  • Jung, Ji-Yong;Kim, Jung-Ja
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.341-348
    • /
    • 2017
  • This study examined the effects of the location and direction of the scolioti curve on postural balance in patients with idiopathic scoliosis. Fifteen subjects were divided into three groups: right thoracic curve group, left lumbar curve group, and double curve group. The dynamic trunk motion (angle variation in the lumbar, thoracolumbar, lower thoracic and upper thoracic region) and plantar pressure distribution (maximum force and peak pressure) were assessed using an ultrasound-based motion analysis system and Emed-at platform system. From the results, it was confirmed that patients with idiopathic scoliosis showed postural imbalance with an increased angle and pressure asymmetry according to the location and direction of the scoliotic curve for dynamic trunk motion and plantar pressure distribution. In addition, there were differences in the postural balance pattern between the single curve and double curve groups. Further studies for developing a rehabilitation training device will be conducted to improve the postural control ability and trunk balance as well as treat scoliosis based on the results of this study.