• Title/Summary/Keyword: 초음파법

Search Result 1,180, Processing Time 0.022 seconds

A Development of Ultrasonic Defect Analysis Program for Composite Motor Case (복합재 연소관의 초음파 결함 분석 프로그램 개발)

  • Kim, Dong-Ryun;Lim, Soo-Yong;Chung, Sang-Ki;Lee, Kyung-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.393-399
    • /
    • 2011
  • A defect analysis program of the composite motor case was developed to apply the ultrasonic signal processing method on basis of the ultrasonic pulse-echo method and the defects of FRP delamination and FRP/Rubber disbond in the composite motor case could be quantitatively measured. The defects detected in the composite motor case were in agreement with the results measured with the computed tomography and video microscope. This paper was described about the development process of the defect analysis program to convert the ultrasonic test data into the C-Scan image.

  • PDF

Design and Implementation of Flaw Image processing System for Automated Ultrasonic Testing System (자동 초음파 검사를 위한 결함 영상 처리 시스템의 설계 및 구현)

  • Kim, Han-Jong;Park, Jong-Hoon;Kim, Chul-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.1
    • /
    • pp.225-232
    • /
    • 2010
  • In this study, an automated ultrasonic testing system and post signal and image processing techniques are developed in order to construct ultrasonic flaw images in weldments. Image processing algorithms are built into the flaw image processing system for the automated ultrasonic testing system. The developed signal and image analysis algorithms addressed in this study include an A-Scan data compression algorithm, ultrasonic image amplification algorithm and B-scan flaw image correction algorithm(SAFT). This flaw image processing system for the automated ultrasonic testing system can be applied to various inspection fields.

Appendix Extraction from Ultrasound Image using ART2 (ART2 알고리즘을 이용한 초음파 영상에서의 충수 추출)

  • Kim, Kwang Baek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.11
    • /
    • pp.2540-2545
    • /
    • 2015
  • In this paper, we propose a novel method to extract appendix from ultrasound image automatically to avoid such subjectivity issue. In the process, we apply a series of image processing algorithms such as Ends_in search stretching for emphasizing brightness contrast and binarization, region labelling, and cubic spline interpolation for extracting lower bound fasicia line that is the base of extracting the appendix. Knowing that the appendix is located at the lower organ area below the bottom fascia line, we conduct a series of image processing techniques to find the fascia line correctly. And then we apply ART2 algorithm to the organ area in order to extract appendix accurately. Through experiment, the effectiveness of the proposed method is verified based on the field experts' evaluations.

Development of Evaluation Method of External Tendon Force by Using the Deriving Ultrasonic Pulse (유도초음파를 이용한 외부 강선의 긴장력 평가기법 개발)

  • Park, Seung-Bum;Hong, Sung-Su;Yoo, Sung-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.6
    • /
    • pp.181-192
    • /
    • 2007
  • In domestic case, there are no results of corresponding researches for measuring external tendon force. The purpose of the present paper is therefore to measure external tendon force by using deriving ultrasonic method. For this purpose, we designed and manufactured wedges and test system, and measured ultrasonic pulse velocity and pulse amplitude. By using measured data, we tried to analyze the characteristics of tendon force, and to derive the relationship between tendon force and ultrasonic pulse velocity, finally to develop the technic of measuring system using ultrasonic pulse velocity. So tendon force-velocity relationship was proposed by equations, and those equations of which errors were 3.92~8.77% will be possible to adapt in-site.

Finite Element Analysis of Ultrasonic Wave Propagation and Scattering (초음파 전파 및 산란 문제의 유한요소 해석)

  • Jeong, Hyun-Jo;Park, Moon-Cheol;Park, Yun-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.4
    • /
    • pp.411-421
    • /
    • 2002
  • The accurate analysis of ultrasonic wave propagation and scattering plays an important role in many aspects of nondestructive evaluation. A numerical analysis makes it possible to perform parametric studies, and in this way the probability of detection and reliability of test results can be improved. In this study, a finite element method was developed for the analysis of ultrasonic fields, the accuracy of results was checked by solving several representative problems. The size of element and the integral time step, which are the critical components for the convergence of numerical results, were determined in a commercial finite element code. Several propagation and scattering problems in 2-D isotropic and anisotropic materials were solved and their results were compared with known analytical or experimental results.

The Study on Scattered Far-Field Analysis of Ultrasonic SH-Wave Using Boundary Element Method (경계요소법을 이용한 SH형 초음파 원거리 산란장 해석에 관한 연구)

  • Lee, Joon-Hyun;Lee, Seo-Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.5
    • /
    • pp.333-339
    • /
    • 1999
  • It is well recognized that ultrasonic technique is one of the most common and reliable nondestructive evaluation techniques for quantitative estimation of defects in structures. For the quantitative and accurate estimation of internal defects. the characteristics of scattered ultrasonic wavefields must be understood. In this study. the scattered near-field and far-field due to a circular cavity embedded in infinite media subjected to incident SH-waves were calculated by the boundary element method. The frequency response of the scattered ultrasonic far-field was transformed into the time-domain signal by obtaining its inverse Fourier transform. It was found that the amplitude of time-domain signal decreases and its time delay increases as the distance between the detecting point of ultrasonic scattered field and the center of internal cavity increases.

  • PDF

Image Magnification using Fuzzy Method for Ultrasound Image of Abdominal Muscles (복부 초음파 영상에서의 퍼지 기법을 이용한 영상 확대)

  • Kim, Kwang-Baek;Lee, Hae-Jung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.4
    • /
    • pp.23-28
    • /
    • 2011
  • Ultrasound images for the abdominal muscles are complicated enough to have difficulty in interpreting their results. For better interpretation, magnifying the original image is necessary but its magnified image could be deteriorated and suffer from information loss. Thus, in this paper, we propose a magnifying method that reduces the gap between the original image and the magnified one in quality using a fuzzy method with weights for its brightness and interpolation. The proposed method extracts information of pixels in magnified image that have most similar characteristics of the original one by applying fuzzy membership function. In the process, the difference in the brightness between pixels of the magnified image and the original one using bilinear interpolation method and the weight value using the interpolation from multiplied values of four pixels are supplied to the fuzzy membership function. In this experiment, the proposed method reduces the cloudy phenomenon appears commonly compared to the bilinear interpolation method among those qualitative issues of image interpretation.

A Basic Study on the Varying Thickness Detection of Steel Plate Using Ultrasonic Velocity Method (초음파 속도법을 활용한 강판의 두께 변화 탐지를 위한 기초연구)

  • Kim, WooSeok;Mun, Seongmo;Kim, Chulmin;Im, Seokbeen
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.146-152
    • /
    • 2020
  • This study was initiated to develop an effective inspection method to detect defects such as corrosion in closed-cell steel members in steel-box girder bridges. The ultrasonic velocity method among various non-destructive method was selected as a rapid and effective method to derive the average propagation velocity in the medium by using the ultrasonic wave velocity method for specimens of different thickness. The regression analysis was performed based on the experimental results, and the results was interpolated to evaluate the prediction accuracy. If the material properties are identical, this ultrasonic velocity method can predict the thickness using the averaged transmitted velocity. In addition, a continuous scanning method moving at 200 mm/s was tested for scanning a wide area of a bridge. The results exhibited that the continuous scanning method was able to effectively scan the different thickness of a bridge.

Synthesis of Ultrasound Contrast Agent: Characteristics and Size Distribution Analysis (초음파 조영제의 합성 및 합성된 초음파 조영제의 특성 분석)

  • Lee, Hak Jong;Yoon, Tae Jong;Yoon, Young Il
    • Ultrasonography
    • /
    • v.32 no.1
    • /
    • pp.59-65
    • /
    • 2013
  • Purpose: The purpose of this study is to establish the methodology regarding synthesis of ultrasound contrast agent imaging, and to evaluate the characteristics of the synthesized ultrasound contrast agents, including size or degradation interval and image quality. Materials and Methods: The ultrasound contrast agent, composed of liposome and SF6, was synthesized from the mixture solution of $21{\mu}mol$ DPPC (1, 2-Dihexadecanoyl-sn-glycero-3-phosphocholine, $C_{40}H_{80}NO_8P$), $9{\mu}mol$ cholesterol, $1.9{\mu}mol$ of DCP (Dihexadecylphosphate, $[CH_3(CH_2)_{15}O]_2P(O)OH$), and chloroform. After evaporation in a warm water bath and drying during a period of 12-24 hours, the contrast agent was synthesized by the sonication process by addition of buffer and SF6 gas. The size of the contrast agent was controlled by use of either extruder or sonication methods. After synthesis of contrast agents, analysis of the size distribution of the bubbles was performed using dynamic light scattering measurement methods. The degradation curve was also evaluated by changes in the number of contrast agents via light microscopy immediate, 12 hours, 24 hours, 36 hours, 48 hours, 60 hours, 72 hours, and 84 hours after synthesis. For evaluation of the role as an US contrast agent, the echogenicity of the synthesized microbubble was compared with commercially available microbubbles (SonoVue, Bracco, Milan, Italy) using a clinical ultrasound machine and phantom. Results: The contrast agents were synthesized successfully using an evaporation-drying-sonication method. The majority of bubbles showed a mean size of 154.2 nanometers, and they showed marked degradation 24 hours after synthesis. ANOVA test revealed a significant difference among SonoVue, synthesized contrast agent, and saline (p < 0.001). Although no significant difference was observed between SonoVue and the synthesized contrast agent, difference in echogenicity was observed between synthesized contrast agent and saline (p < 0.01). Conclusion: We could synthesize ultrasound contrast agents using an evaporation-drying-sonication method. On the basis of these results, many prospective types of research, such as anticancer drug delivery, gene delivery, including siRNA or microRNA, targeted molecular imaging, and targeted therapy can be performed.

Development of Fine Dust Measurement Method based on Ultrasonic Scattering (초음파 산란 기법을 적용한 미세먼지 측정법 개발)

  • Choi, Hajin;Woo, Ukyong;Hong, Jinyoung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.40-48
    • /
    • 2019
  • New concept of fine dust measurement method is suggested based on ultrasonic scattering. These days, fine dust has been social problem in Korea, and many researches has been conducted including the area structural maintenance. Conventional measurement system such as optical scattering and semiconductor has a limit from environmental factors like relative humidity. However, ultrasound is based on mechanical waves, which perturb mechanical properties of medium such as density and elastic constants. Using the advantage, the algorithm for fine dust measurement is derived and evaluated using 2-D finite difference method. The numerical analysis simulates ultrasonic wave propagation inside multiple scattering medium like fine dust in air. Signal processing scheme is also suggested and the results show that the error of the algorithm is around minimum of 0.7 and maximum of 24.9 in the number density unit. It is shown that cross-section of fine dust is a key parameter to improve the accuracy of algorithm.