• Title/Summary/Keyword: 초기발화

Search Result 40, Processing Time 0.022 seconds

Flame and Carbonization Patterns of Animal-Origin Foods Ignited by Overheating (과열에 의해 발화된 동물성 식품의 화염 및 탄화 패턴에 관한 연구)

  • Lee, Jeong-Hun;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.126-131
    • /
    • 2019
  • Real-scale fire tests were performed on animal-origin foods using a gas stove with no overheating prevention device. When the animal-origin foods were ignited, a large quantity of white smoke and steam was generated from them; however, when they became dry and began to carbonize, a dark smoke was generated. Even after the gas stove was overheated for more than 5400 s, mackerel, pollack, chicken, etc., did not ignite. However, pork, beef, and tuna caught fire after 2643 s, 2819 s, and 6492 s of heating, respectively. The flame patterns of animal-origin foods were in the forms of a mixed laminar flow and a turbulent flow, and a halo pattern was produced. A sand glass form of the flame pattern was generated when a kitchen hood was operated, but a triangular flame pattern was produced when the kitchen hood was not operated. When the tuna in the pot was overheated, it spontaneously ignited after 6492 s, with the surface temperature of the kitchen hood rapidly rising to 464.5 ℃. Moreover, the temperature at the back of the pot, which was 6 cm away from the outer surface of the upper part of the pot, was 869 ℃ after 6660 s because of the radiant heat. The flame formed a sand glass pattern on the kitchen wall. When the kitchen hood was not operated, or when the flame grew lower than the height of the ceiling, a triangular pattern was formed.

Radiolysis of Paraffin Encapsulation Wax (파라핀 고화체의 방사선적 가수분해)

  • Kim, Chang-Lak;Lee, Myung-Chan;Park, Won-Jae;Suk, Tae-Won;Burns William G.
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.4
    • /
    • pp.237-243
    • /
    • 1995
  • An estimate is made on the potential generation rate of H: from radiolysis of the Paraffin-wax encapsulant Proposed for the solidified liquid concentrate wasteform. The results show that the radiolytic Production of $H_2$ from paraffin-wax-encapsulated waste is dominated by the radiation energy released from $^{60}Co$. The radiolytic production of $H_2$ will proceed at an initial rate equivalent to aproximately $4.4{\times}10^2cm^3yr^1$ in 200 litre drums that are partly filled with 120 litres of encapsulated waste. The gas production rate will fall to a value of $7.2cm^3yr^1$ after 100 years. The lower flammable limit for $H_2$ in air will be reached in about 25 years and the lower explosive limit for $H_2$ in air would not be reached in 1000years. The timescale in which these safety-related limits are reached is strongly dependent on the level of filling of each waste drum. A reduction of the air space inside each drum would reduce the time required to reach the lower flammable limit.

  • PDF

A Study on how to improve Survey of Fire Safety Management of manufacturing plants (The Medium and Small-sized Manufacturing industry) (제조 사업장의 소방안전관리 실태조사 및 개선방안에 대한 연구 (중소규모 제조사업장 중심으로))

  • Choe, Yeong-Gi;Kim, Byeong-Seok
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.11a
    • /
    • pp.483-497
    • /
    • 2013
  • 현대사회가 발전 할수록 대량산업화와 도시화가 심화되어 건축물의 초고층화 및 대형화가 증가하고 있으며, 안전적인 건축물 보다는 건물 및 제조사업장의 시각적인 디자인에 치우쳐 화재하중이 높은 건축자재의 내 외장재 및 고급스러운 장식물을 사용함으로써 그 위험뿐 만 아니라 화재발생시 대규모 인명 및 재산상의 피해를 가져오게 된다. 그리고 제조사업장화재는 화재로 인한 직접적인 손실 즉 물적 손실은 물론 생산중단으로 인한 간접적인 손실은 실로 측정하기가 어렵다. 지금까지 발생한 제조사업장화재의 발화요인별 분석은 부주의, 전기적, 미상 순으로 인한 화재가 가장 많고 발화열원은 작동기기, 담뱃불(라이터), 마찰 전도 복사등이 주요 원인이 되고 있고 대형화제 취약시설로는 공장 및 창고로 나타나고 있다. 소방방재청의 통계자료를 살펴보면 2012년 화재 발생현황 중 발화요인에 대한 화재별 장소 건수를 검토 한 결과 비주거의 화재발생 16,009건 중 5,758건으로 (36%)부주의이고, 주거에도 화재발생 10,715건 중 5,560건으로 51.9%의 부주의로 가장 높은 것으로 나타났다. 그러므로 제조사업장의 사소한 부주의로 발생하는 화재를 예방하기 위해서는 소방안전관리자의 처우개선과 기업활동규제완화의 겸직 허용을 재검토 하여야 하며, 소방안전관라자의 실무능력 강화를 위한 소방안전관리 실무교육과정을 이론적 교육 보다는 현장 실습위주로 할 필요가 있다. 이를 위해서는 소방안전관리자에 대한 법정 실무교육 횟수를 확대하여 현행 2년에 1회 에서 1년에 1회로 하고, 실무교육에 있어서도 우수송방안전관리 업체를 선정하여 화재예방에 대한 구체적인 업무를 활성화 하고, 문제 발생요소들을 분석하여 실습을 통한 소방안전관리자의 실무교육을 실시해야 할 것이다. 이러한 전문 소방안전관리자로 소방대상물의 소방교육 및 훈련을 성실히 수행 해야 할 것 이다. 한순간의 부주의로 인하여 화재가 발생하면 돌이킬 수 없는 수백명의 생명을 앗아가고, 수백억원대의 재산피해를 줄이기 위해서는 소방안전관리자의 역량을 넓히고 화재예방 업무를 최우선적으로 수행해야 할 것이다. 화재예방을 위해 소방안전관리자의 업무개선 및 전문교육을 활성화 하여 업무능력을 향상 시켜 화재발생시 초기진압에 신속하고 정확하게 대처해야 한다는 것이 전문적인 화재예방 대책 일 것이다.

  • PDF

A Numerical Study on the Effects of Meteorological Conditions on Building Fires Using GIS and a CFD Model (GIS와 전산유체역학 모델을 이용한 기상 조건이 건물 화재에 미치는 영향 연구)

  • Mun, Da-Som;Kim, Min-Ji;Kim, Jae-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.3
    • /
    • pp.395-408
    • /
    • 2021
  • In this study, we investigated the effects of wind speed and direction on building fires using GIS and a CFD model. We conducted numerical simulations for a fire event that occurred at an apartment in Ulsan on October 8, 2020. For realistic simulations, we used the profiles of wind speeds and directions and temperatures predicted by the local data assimilation and prediction system (LDAPS). First, using the realistic boundary conditions, we conducted two numerical simulations (a control run, CNTL, considered the building fire and the other assumed the same conditions as CNTL except for the building fire). Then, we conducted the additional four simulations with the same conditions as CNTL except for the inflow wind speeds and direction. When the ignition point was located on the windward of the building, strong updraft induced by the fire had a wide impact on the building roof and downwind region. The evacuation floor (15th floor) played a role to spread fire to the downwind wall of the building. The weaker the wind speed, the narrower fire spread around the ignition point, but the higher the flame above the building reaches. When the ignition point was located on the downwind wall of the building, the flame didn't spread to the upwind wall of the building. The results showed that wind speed and direction were important for the flow and temperature (or flame) distribution around a firing building.

The Male Muse and the Female Poetic Voice: Early Poems of Sylvia Plath (남성 뮤즈와 여성 시인의 목소리: 실비아 플라스 초기시 연구)

  • Ko, Chan-mi
    • Women's Studies Review
    • /
    • v.26 no.1
    • /
    • pp.207-237
    • /
    • 2009
  • This paper aims to show that Sylvia Plath searched for the female poetic voice, by tracing the aspects of her early poems. This study attempts to demonstrate that Plath disclosed the violence of male-centered literary tradition against women poets although her early poems seem to be written from a male point of view. In her poems, "Snakecharmer", "Full Fathom Five", and "The Colossus", it is particularly found that Plath hoped to be empowered with the poet's voice, which nevertheless resulted almost in silence or babbling. Plath, indeed, devised a strategy in order to show that, for women poets, the patriarchal literary tradition is a destructive power rather than a generative one. Namely, women poets are not able to fully grow out of a male-oriented tradition. On that account, she tried to represent in her early poems herself who sought to be empowered with an authoritative voice, invoking the male muse, but this ended in failure. Plath was skeptical about the way she had desired to find her own voice by relying upon the male muse, and she needed to free herself from that literary tradition.

A Study on the Ignition Delay Effect in the Reduced-Scale Fire by Flame-Resistant Treated Plywood (유사 화재에 대한 방염처리 합판의 착화 지연효과 연구)

  • Lee, Seung-Hyun;Kim, Hwang-Jin;Lee, Sung-Eun;Oh, Kyu-Hyung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.180-187
    • /
    • 2011
  • 본 논문은 다중이용업소와 목조건축물에 자주 사용되는 미송합판에 방염처리를 하여 유사 화재를 구현하고, 그 화염 세기에 따른 방염의 실효성을 실험한 것이다. 방염처리를 하면 화재 시 가연물의 초기착화시간을 지연시켜 화재성장속도를 늦출 수 있고, 원활한 소화활동을 가능하게 해준다. 하지만 어느 정도 화재가 진행되어 화염이 거세지면, 45도 연소시험을 통한 방염기준을 충족하여도 그 성능을 기대하기 어렵다고 한다. 따라서 45도 연소시험 시 사용되는 65mm의 불꽃보다 큰 화염상태(초기착화 이후의 상태)에서 방염처리한 내장재(미송합판)의 방염성능이 유지되는지의 여부를 실제로 입증하고 그 근거를 뒷받침하기 위하여 본 연구를 시작하게 되었다. 실험에서는 화재의 규모(화염의 세기)를 달리하여 각기 다른 종류의 방염제로 방염 처리한 미송합판의 착화 시 화염온도, 복사열 유속 그리고 착화지연시간을 파악하였으며, 45도 연소시험과 관련하여 방염성능을 분석하였다. 45도 연소시험의 경우 실험에 사용한 방염 처리 합판은 방염성능 기준을 만족하는 것으로 나타났으며, 소규모 유사 화재로 직경 10cm 연소용기를 사용한 연소실험에서는 방염 처리한 합판의 착화지연시간이 평균적으로 대규모 유사 화재실험보다 길어 어느 정도는 방염효과를 갖는 것으로 나타났다. 하지만 대규모 유사 화재로 1단위 유류화재 연소용기를 사용한 연소실험의 경우 열방출율이 커 형성된 탄화막이 무분별하게 박리되고 발화가 일어나 착화지연시간의 차이를 구별하기 어려웠기 때문에 방염효과를 기대할 수 없었다.

  • PDF

A Study of the Suppression System based on the Fire Protection System the Korea Cultural Property due to the Forest Fire -About Water Mist System- (산림화재로부터 문화재를 보호하는 소방시설에 관한 연구 -미분무수설비를 중심으로-)

  • Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.44-51
    • /
    • 2007
  • Most of the Korea temples of cultural property are wooden buildings and easy combusted. They are often located in mountain area far away from the city. It is very difficult to approach the fight area. The putting out is very difficult in the initial fire time. And for protecting the cultural property in the long-term continuous fire source there are some restrictions in water source and suppression system. In this paper the initial putting out fire due to the forest fire and the protection of cultural property in the long-term continuous fire source were researched. The improved project about fire control facilities of the Korea cultural property was proposed. In the proposed project the facilities using Water mist which can reduce more loss than existing facilities using water are applied. In view of the topographic position the method of eliminating the energy of combustibles and wall for cutting off the heat in the fire control facilities are also mentioned.

Application of Water Mist System for a Power Transformer Room - Fire Extinguishment(Part 1) (변압기실 화재에 대한 미분무수 소화시스템의 적용 - 소화특성을 중심으로(Part 1))

  • Han Yong-Shik;Choi Byung-Il;Kim Myung-Bae
    • Fire Science and Engineering
    • /
    • v.19 no.4 s.60
    • /
    • pp.32-36
    • /
    • 2005
  • A water mist system was considered as a possible alternative to a gaseous suppression system that can not prevent re-ignition after fire extinguishment for a power transformer room. This study deals with the fire suppression capability of the water mist systems. High-and low-pressure water mist systems were examined to compare efficiency of both systems. The power transformer examined in this study occupied about $7\%$ of a $10m\times10m\times$ transformer room. Full-scale suppression tests were performed for six different fire scenarios: two spray fires, three pool fires and one cascade fire. The fire suppression test results demonstrated that the high-pressure system was superior to the low-pressure system, especially considering oxygen depletion and the ambient temperature distribution.

Survey for Early Detection Techniques of Smoke and Flame using Camera Images (카메라 영상을 이용한 연기 및 화염의 조기 감지 최신 연구 동향)

  • Kang, Sung-Mo;Kim, Jong-Myon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.4
    • /
    • pp.43-52
    • /
    • 2011
  • With the rapid development of technology, skyscrapers are widely spread and they are tightly coupled. If fire occurs in a building, it is easily spread to neighboring buildings, resulting in the large number of victims and property damages. To remove fire disasters, the need for early fire detection techniques is increasing. To detect fire, detecting devices for heat, smoke, and flame have been used widely. However, this paper surveys and presents the latest research which focuses on early smoke and flame detection algorithms and systems with camera's input images. In addition, this paper implements and evaluates the performance of these flame and smoke detection algorithms with several types of movies.

A Study on the Movement focused on Bernard Tschumi's Early Works (Bernard Tschumi의 초기 작품을 중심으로 본 움직임 연구)

  • Suh, Jeong-Yeon
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.1
    • /
    • pp.27-34
    • /
    • 2009
  • Architect Bernard Tschumi had explored a new architectural conception through his own notional devices such as space, event and movement during 1970s. But, among these notions, the concept of movement was ambiguous and difficult to adopt it for architectural design strategy. Because the movements in everyday's behaviour or in dancing art are significantly different from architectural thought. However he had succeeded in coining the creative notion of movement as almost real body's and of living flesh. He invented an acute methodology and bold interpretation for his early experimental works. So, this paper tried to understand and analyse his concept of movement focused on his early works. The results of this paper's discussion are as follows; First, Tschumi's movement concept Is dynamic one operated by desire and can violate space in physical level as well as metaphysical level. Next, the movement performs the role of generator which deforms space or even generate it. Third, his movement can be readable only when you go down and bring it in practice. Also it Is unblocked potentiality, undetermined sequential material and unfinished practice. Fourth, when Tschumi's movement could be thought as walking, this walking movement makes up a story through rhetorical speech acts that are presented by turns and detours.