• Title/Summary/Keyword: 체적 지수

Search Result 119, Processing Time 0.024 seconds

A Study on Prospective Plan Comparison using DVH-index in Tomotherapy Planning (토모 테라피 치료 시 선량 체적 히스토그램 표지자를 이용한 치료계획 비교에 관한 연구)

  • Kim, Joo-Ho;Cho, Jeong-Hee;Lee, Sang-Kyoo;Jeon, Byeong-Chul;Yoon, Jong-Won;Kim, Dong-Wook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.113-122
    • /
    • 2007
  • Purpose: We proposed the method using dose-volume Histogram index to compare prospective plan trials in tomotherapy planning optimization. Materials and Methods: For 3 patients in cranial region, thorax and abdominal region, we acquired computed tomography images with PQ 5000 in each case. Then we delineated target structure and normal organ contour with pinnacle Ver 7.6c, after transferred each data to tomotherapy planning system (hi-art system Ver 2.0), we optimized 3 plan trials in each case that used differ from beam width, pitch, importance. We analyzed 3 plan trials in each region with isodose distribution, dose-volume histogram and dose statistics. Also we verified 3 plan trials with specialized DVH-indexes that is dose homogeneity index in target organ, conformity index around target structure and dose gradient index in non-target structures. Results: We compared with the similarity of results that the one is decide the best plan trial using isodose distribution, dose volume histogram and dose statistics, and the another is using DVH-indexes. They all decided the same plan trial to better result in each case. Conclusion: In some of case, it was appeared a little difference of results that used to DVH-index for comparison of plan trial in tomotherapy by special goal in it. But because DVH-index represented both dose distribution in target structure and high dose risk about normal tissue, it will be reasonable method for comparison of many plan trials before the tomotherapy treatments.

  • PDF

Research on Laminate Design Parameters to Maximize Performance Index of Composite Pressure Vessel (복합재 압력용기의 성능지수 최대화를 위한 적층 설계변수 연구)

  • Jeong, Seungmin;Hwang, Taekyung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.3
    • /
    • pp.21-27
    • /
    • 2018
  • In this paper the laminate design parameters are researched to maximize the performance index of a composite pressure vessel. To maximize the performance index, the three design variables that the thickness of each of helical and hoop layers and the length of hoop layer are considered under the assumption of fixed internal space. To optimize the variables, the response surface method is introduced for construction of the surrogate model and the ANOVA(analysis of variance) is performed to evaluate the effects of the variables. The optimization problem is formulated to maximize performance index under the burst pressure constraint. To verify the effectiveness of the research, numerical analyses are performed for the optimum model.

Analysis of Thermal Response of Rectangular Plates Made of Functionally Graded Materials (경사.기능재료 사각평판의 열적거동 해석)

  • 민준식;강호식;정남희;송오섭
    • Composites Research
    • /
    • v.17 no.5
    • /
    • pp.78-84
    • /
    • 2004
  • In this paper, a study of thermal response of two types of functionally graded materials (FCM) plates composed of $\textrm{Al}_2\textrm{O}_3$ and Ti-6Al-4V is presented. The material properties of the functionally graded plates are assumed to vary continuously through the thickness of the plate according to a power law distribution of the volume fraction of the constituents. It is supposed that the top and bottom surfaces of the plate are heated and kept as constant thermal boundary conditions. The fundamental equations for rectangular plates of FGM are obtained using Hamilton's variational principles. The solution is obtained in terms of Navier Solution. The influence of volume fraction and temperature is studied on the static deflection and natural frequency of FCM plate.

Slope Failure Index System Based on the Behavior Characteristics : SFi-system (거동 특성에 따른 사면 파괴 지수 시스템 : SFi-system)

  • 윤운상;정의진;최재원;김정환;김원영;김춘식
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.2
    • /
    • pp.23-37
    • /
    • 2002
  • Failure of the cut slope is triggered by combination of internal and extemal failure factors. Internal failure factors are related to geological and geometrical conditions of slope itself, and natural and/or artificial loadings on slope can be the external failure factors. Influences of these failure factors show different intensity according to the ground condition and are controlled by behavior characters of the slope. In this study, the soil depth ratio(SR), block size ratio(BR) and rock strength are used as the criteria to divide ground condition based on behavior characteristics. Ground condition of the slope is divided into discontinuous jointed rock mass and continuos soil-like mass, highly fractured rock mass and massive rock mass by the criteria(SR and BR). The SFi-system is a rating system to determine the slope failure index(SFi) by analyzing internal and external factors based on classification of the ground condition. The results of the SFi-system application to the real cut slopes show close relationship between the SFi value and potential or dimension of the failure. Therefore, the SFi-system can be used as a useful tool to predict and analyze the characteristic of the slope failure.

A study on the $PbTiO_3/$-polymer, 0-3 Composite Hydrophone ($PbTiO_3/$-폴리머, 0-3 컴포지트 하이드폰에 관한 연구)

  • 김일호;이성갑;김현재;이영희
    • Electrical & Electronic Materials
    • /
    • v.3 no.1
    • /
    • pp.9-19
    • /
    • 1990
  • 본 연구에서는 산회물 혼합법, 솔-젤법, 공침법등의 세가지 방법으로 PbTiO$_{3}$분말을 제조하여 폴리머와 혼합 O-3 복합재료를 제작한 후, 하이드로폰으로의 응용을 위한 제 특성을 고찰하였다. 비유전상수는 PbTiO$_{3}$의 체적비 증가에 따라 지수함수적으로 증가하였으며 유전손실은 선형적으로 증가하였다. 수정입방체 모델로 부터 계산된 변형계수 n은 M-O, S-G, C-P의 경우 각각 0.724, 0.585, 0.483으로 나타났다. 압전 변형계수 d$_{33}$는 PbTiO$_{3}$의 체적비, 분극전장 및 분극 시간의 증가에 따라 증가하였으며 일정시간 경과후에는 포화값을 나타내었다.다.

  • PDF

Waterhammering on Pump Pipeline Systems (펌프 관로계의 수격현상)

  • 김경엽;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.331-355
    • /
    • 1997
  • 본 연구에서는 에어챔버가 설치된 펌프관로계에서 수격현상에 대한 현장실험을 실시하고, 에어챔버의 입력변수 및 설계인자가 수격현상에 어떠한 영향을 미치는지 수치계산과 실험을 통하여 조사한 후 다음과 같은 결론을 얻었다. (1) 수치계산에 사용된 입력변수중 폴리트로프지수, 오리피스 유량계수, 압력파 전파속도순으로 수격현상에 대한 영향이 크게 나타났으며, 수치계산은 이 변수값이 각각 1.3, 0.7, 1,050m/s일 때 측정된 압력변동 및 공기체적변화를 가장 잘 모사하였다. (2) 에어챔버내 초기공기체적이 증가하면 압축공기의 압력변화율이 작아지기 때문에 수격현상의 주기는 길어지고, 관로내 압력변화는 감소하였다. 측관에 설치한 오리피스 내경을 줄임으로써 상승압은 상당히 완화되었으며, 시간이 지남에 따라 수격작용도 보다 빨리 감쇄되었다. 수치계산결과는 수격현상의 1-2주기까지 측정값과 비교적 잘 일치하였으며, 펌프관로계에 작용하는 최대.최소압력 및 그 발생시간도 합리적으로 예측되었다. (3) 수치계산은 측정된 과도특성 값들을 약 5%이내의 오차로 예측하였으며, 개발된 전산프로그램은 실제 펌프관로계에 대한 수격완화장치를 설계하는데 매우 유용하게 사용될 것으로 판단된다.

  • PDF

Manufacturing of Goami Flakes by using Extrusion Process (압출성형공정을 이용한 고아미 후레이크 제조)

  • Tie, Jin;Lee, Eui-Suk;Hong, Soon-Teak;Ryu, Gi-Hyung
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.2
    • /
    • pp.146-151
    • /
    • 2007
  • Resistant starch (RS) content, paste viscosity, water solubility and absorption index, bulk density, color, compression force, and bowl life of Goami flakes manufactured by extrusion process were determined to evaluate Goami (high fiber rice) as a food material. Various extrusion process conditions included barrel temperature (90, 110, $130^{\circ}C$) and moisture content (50, 55%). RS content in the extruded pellet and defatted flake ranged from $8.00{\sim}8.56%$ and $6.57{\sim}9.53%$ respectively. RS content increased as moisture increased from 50% to 55%. Peak viscosity, trough viscosity, final viscosity, and setback viscosity of the extruded pellet and defatted flake decreased with steeping for 1 hr, and the breakdown viscosity significantly increased. The water solubility and absorption index increased in the flake compared to Goami and extruded pellet. The water solubility index of the extruded pellet was lower than that of Goami, while its water absorption index was higher than Goami. The bulk density of the flake ranged from $0.35{\sim}0.44$ g/mL. The bowl life of the flake was $12.4{\sim}19.4$ min, which was longer than commercial breakfast cereals on the market.

Study of the seroma volume changes in the patients who underwent Accelerated Partial Breast Irradiation (부분유방방사선치료(Accelerated Partial Breast Irradiation) 환자의 장액종(Seroma) 체적 변화에 대한 연구)

  • Kim, Dae Ho;Son, Sang Jun;Mun, Jun Ki;Seo, Seok Jin;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.65-75
    • /
    • 2016
  • Purpose : By analyzing seroma volume changes in the patients who underwent Partial breast radiation therapy after breast conserving surgery, we try to contribute to the improvement of radiotherapy effect. Materials and Methods : Enrolled 20 patients who underwent partial breast radiation therapy by ViewRay MRIdian System were subject. After seeking for the size of the removed sample in the patients during surgery and obtained seroma volume changes on a weekly basis. On the Basis of acquired volume, it was compared with age, term from start of the first treatment after surgery, BMI (body mass index) and the extracted sample size during surgery. And using the ViewRay MRIdian RTP System, the figure was analyzed by PTV(=seroma volume + margin) to obtain a specific volume of the Partial breast radiation therapy. Results : The changes of seroma volume from MR simulation to the first treatment (a week) is 0~5% in 8, 5~10% in 3, 10 to 15% in 2, and 20% or more in 5 people. Two patients(A, B patient) among subjects showed the biggest change. The A patient's 100% of the prescribed dose volume is 213.08 cc, PTV is 181.93 cc, seroma volume is 15.3 cc in initial plan. However, while seroma volume decreased 65.36% to 5.3 cc, 100% of the prescribed dose volume was reduced to 3.4% to 102.43 cc and PTV also did 43.6% to 102.54 cc. In the case of the B patient, seroma volume decreased 42.57% from 20.2 cc to 11.6 cc. Because of that, 100% of the prescribed dose volume decreased 8.1% and PTV also did to 40%. Conclusion : As the period between the first therapy and surgery is shorter, the patient is elder and the size of sample is smaller than 100 cc, the change grow bigger. It is desirable to establish an adaptive plan according to each patient's changes of seroma volume through continuous observation. Because partial breast patients is more sensitive than WBRT patients about dose conformity in accordance with the volume change.

  • PDF

Evaluation of Dose Volume and Radiobiological Indices by the Dose Calculation Grid Size in Nasopharyngeal Cancer VMAT (비 인두암 체적 조절 호형 방사선 치료의 선량 계산 격자 크기에 따른 선량 체적 지수와 방사선 생물학적 지수의 평가)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Shim, Jae-Goo;Park, So-Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.265-272
    • /
    • 2020
  • The purpose of this study was to investigate the dose-volume indices and radiobiological indices according to the change in dose calculation grid size during the planning of nasopharyngeal cancer VMAT treatment. After performing the VMAT treatment plan using the 3.0 mm dose calculation grid size, dose calculation from 1.0 mm to 5.0 mm was performed repeatedly to obtain a dose volume histogram. The dose volume index and radiobiological index were evaluated using the obtained dose volume histogram. The smaller the dose calculation grid size, the smaller the mean dose for CTV and the larger the mean dose for PTV. For OAR of spinal cord, brain stem, lens and parotid gland, the mean dose did not show a significant difference according to the change in dose calculation grid size. The smaller the grid size, the higher the conformity of the dose distribution as the CI of the PTV increases. The CI and HI showed the best results at 3.0 mm. The smaller the dose calculation grid size, the higher the TCP of the PTV. The smaller the dose calculation grid size, the lower the NTCP of lens and parotid. As a result, when performing the nasopharynx cancer VMAT plan, it was found that the dose calculation grid size should be determined in consideration of dose volume index, radiobiological index, and dose calculation time. According to the results of various experiments, it was determined that it is desirable to apply a grid size of 2.0 - 3.0 mm.

Analysis of the Micro-Structural and Mechanical Properties in Human Femoral Head Trabecular Bone with and without Osteoporosis (대퇴골두 해면골의 미세구조 특성과 기계적 특성의 분석)

  • Won Ye-Yeon;Baek Myong-Hyun;Cui WenQuan;Chun KeyoungJin;Kim Man Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.519-523
    • /
    • 2004
  • This study investigates micro-structural and mechanical properties of trabecular bone in human femoral head with and without osteoporosis using Micro-CT and finite element-model. 15 cored trabecular bone specimens with 20min of diameter were obtained from femoral heads with osteoporosis (T-score > -2.5 ) resected for total hip arthroplasty, and 5 specimens were removed from femoral head of cadavers, which has no history of musculoskeletal diseases. A high-resolution micro-CT system was used to scan each specimen to obtain histomorphometry indices. Based on obtained micro-images(pixel size=21.31㎛), a FE-model was created to determine mechanical property indices. While non-osteoporosis group had increases trabecular thickness, bone volume, bone volume fraction, degree of anisotropy and trabecular number compared with those of non-osteoporotic group, the non-osteoporotic group showed decreases in trabecular separation and structure model index. Regarding the mechanical property indices, reaction force, apparent stress and young's modulus were 1ower in osteoporotic group than in non-osteoporotic group. Our data shows salient deteriorations in trabecular micro-structural and mechanical properties in human femoral head with osteoporosis.