• Title/Summary/Keyword: 청력 검사

Search Result 147, Processing Time 0.031 seconds

Phoneme Recognition and Error in Postlingually Deafened Adults with Cochlear Implantation (언어습득 이후 난청 성인 인공와우이식자의 음소 지각과 오류)

  • Choi, A.H.;Heo, S.D.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.3
    • /
    • pp.227-232
    • /
    • 2014
  • The aim of this study was to investigate phoneme recognition in postlingually deafened adults with cochlear implantation. 21-cochlear implantee were participated. They was used cochlear implants more than 1 year. In order to measure consonant performance abilities, subjects were asked for 18 items of Korean consonants in a "aCa" condition with audition alone. The scores ranged from 11 to 86 ($60{\pm}17$)%. The consonant performance abilities correlated with implanted hearing threshold level, significantly (p<.046). This results suggest that consonant performance abilities of postlingual deafened adults cochlear implantee be important for implanted hearing. They had higher correct rates for fricatives and affricatives with distinctive frequency bands than for plosives, liquids & nasals with the same or adjacent frequency bands. All subjects had confusion patterns among the consonants of the same manner of articulation. The reason of consonant confusions was caused that they couldn't recognize different intensities and durations of consonants with the same or adjacent frequency bands.

  • PDF

Clinical Observation on Voice Disorder (음성장애에 대한 임상적고찰)

  • 이종원
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1979.05a
    • /
    • pp.7.2-8
    • /
    • 1979
  • The tests related to air usage are valuable for evaluating phonatory function of clinical cases having glottic incompetence. Measurement of mean air flow rate, maximum phonation time and phonation quotient are important test for voice disorder. Stroboscopy is very useful for clinical evaluation of abnormality in the mode of vocal cord vibration. Author obtained following clinical result from 56 cases of laryngeal disorders in Kurume medical school in Japan. 1) Unilateral laryngeal lesions, are 35 cases (62.5%) and bilateral laryngeal lesions are 21 cases (37.5%). 2) Sex ratio is 39 cases (69.8%) of male and 17 cases (30.2%) of female. 3) In maximum phonation time below 10 seconds are 26 cases (46.4%) and above 10 seconds are 30 cases (53.6%). 4) In phonation quotient below 300 ml/sec are 33cases (58.9%). and above 300ml/sec are 23 cases (41.0%). 5) In mean air flow rate below 300ml/sec are 37 cases (66.1%) and above 300ml/sec are 19 cases (33.9%). 6) Symmetry of vibratory movement of the vocal cord, regularity of vibration, amplitude of vibration, wave on the mucosa and glottic closures are observed by stroboscopic examination. 7) Postoperative voice test and stroboscopic examination revealed good result in compare pre-operation with post-operation.

  • PDF

Changes of Acoustic Reflex Thresholds and Speech-In-Noise Perception Using Personal Listening Device Under Subway Interior Noise (지하철 실내 소음 하에서 음향기기 사용에 따른 음향반사역치와 소음 속 어음인지 변화)

  • Han, Woojae;Chun, Hyungi;Ma, Sunmi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.2
    • /
    • pp.138-145
    • /
    • 2015
  • Although it is well-known that environmental noise can lead to hearing loss in individuals, the true extent of subway noise effects in the general population remains poorly understood. The purpose of the present study is to see changes of acoustic reflex thresholds and speech perception scores when passengers listen to music presented from their personal listening device in the subway. Forty subjects with normal hearing participated being divided into two groups, experimental and control groups. As a baseline, all subjects were measured by acoustic reflex thresholds in five test frequencies and Korean speech perception in noise (KSPIN) test at 0 and -5 dB SNR. In the experiment, the control group read newspaper or magazine in the subway noise, whereas the experimental group listened to music presented from their smartphone under the subway noise through speakers at 73.45 dBA for 60 min. After completing the experiment, two groups also conducted both acoustic reflex thresholds and KSPIN tests in the same condition as the baseline. The results showed that there was a significant difference of correct percent in speech-in-noise test between experimental and control groups and of that between two signal-to-noise ratios, which means the double noise exposure of 60 min might cause some degradation of speech perception when noise increases compared to only subway noise condition that was not statistically significant difference. We concluded that a risk of some degraded speech perception ability would be expected when passengers have a habit of listening to music in the subway noisy situation for a long duration.

Clinical Observation on Hearing Impairment in Diabetes Mellitus Patients (당뇨병 환자의 청각장애에 대한 관찰)

  • 지정민;송재권
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1977.06a
    • /
    • pp.3.3-3
    • /
    • 1977
  • For a year from Jan. 1976 to Dec. 1976, the authors have performed the clinical observation in accordance with audiometric test and clinical findings of 43 cases (male 25: female 18) who were diagnosed of diabetes mellitus in diabetic clinic of our hospital. The results are as follows; 1) Eight of 43 cases reveal hearing impairment, and almostly abrupt drop or descending in hearing types. 2) The incidence of hearing impairment is higher in middle and older age group. 3) Hearing impairment has not related to duration of the disease but blood sugar level and total serum cholesterol level in some extent. 4) The incidence of hearing impairment is higher in cases accompanied by complications such as retinopathy, hypertension, neuropathy etc. 5) In etiology of hearing impairment, multiple factors seem to be concerned.

  • PDF

An Experimental Study on the Fitting of 64 Channel Digital Hearing Aid by In-situ Method (64채널 디지털 보청기의 In-situ에 의한 휘팅 실험 연구)

  • Jarng, Soon-Suck
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.5
    • /
    • pp.273-279
    • /
    • 2012
  • In this thesis, a nonlinear compression fitting method was studied for each frequency channel of a 64 channel digital hearing aid. Unlike conventional fitting formula method done from the result of the hearing loss test, the present fitting method uses the auditory threshold of sound pressure measured near the tympanic membrane while ITE (In-The-Ear) hearing aid is fitted into the user's ear canal. Also, the spectral distribution of the voice sound pressure was used for realizing of output sound pressure compression curves against input sound pressure level. Theoretical research results of FFT-iFFT compression algorithm has been evaluated by experimental gain measurements at each different input sound pressure level 50 dB, 70 dB, 90 dB respectively.

A Study on the Self-voice Suppression Algorithm in a ZigBee CROS Hearing Aid (지그비 크로스 보청기에서의 자기음성 억제 알고리즘 연구)

  • Im, Won-Jin;Goh, Young-Hwan;Jeon, Yu-Yong;Kil, Se-Kee;Yoon, Kwang-Sub;Lee, Sang-Min
    • Journal of IKEEE
    • /
    • v.13 no.3
    • /
    • pp.62-71
    • /
    • 2009
  • In this study, we developed a wireless CROS(contralateral routing of signal) hearing aid for unilateral impaired people. CROS hearing aid takes sound from an ear with poorer hearing and transmit to another ear with better hearing. Generally, the self-voice delivered through the receiver of CROS hearing aid can be very loud. It is hard to perceive target speech because of loud self-voice. To compensate it, a self-voice suppression algorithm has been developed. we performed SDT(speech discrimination test) for evaluation of the self-voice suppression algorithm. One-syllable words was used as test speech and recorded with self-voice at a 1m distance. As the results, SDT score was improved about 11% when the self-voice suppression algorithm was processed. It is verified that the self-voice suppression algorithm helps speech perception at a time to communicate with others.

  • PDF

Hearing Screening Test for High Risk Neonate (고위험군 신생아의 청각 스크린 검사)

  • Soh, Un-Ki;Na, Bak-Ju;Lee, Moo-Sik;Kim, Chul-Woung;Lim, Nam-Gu
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.599-602
    • /
    • 2009
  • 본 연구는 2006년 3월부터 2007년 2월까지 일개 대학병원에서 출생한 고위험군 신생아 121명을 대상으로 청각선별검사인 자동화 유발이음향방사와 확진검사인 청성뇌유발전위검사를 실시하여 임상양상과 청각장애 발생률, 검사소요 시간에 대해 조사하였다. 결과는 다음과 같다. 1. 청각장애발생률은 전체 고위험군 신생아 121명 중 5명의 신생아가 난청으로 조기에 진단되었다. 2. 난청으로 확진 받은 신생아 5명의 관련 질병을 살펴보면 고빌리루빈혈증 2명, 저체중 1명, 구개열 1명, 다운증후군 1명이었다. 3. 난청으로 확진 받은 신생아 5명의 청력손실정도는 양측 고도난청 1명(70dB), 양측 중도난청 2명(55dB), 편측성 난청 2명으로 나타났다. 4. 검사소요 시간은 선별검사인 유발이음향방사 검사를 실시하는 데 소요된 총 시간의 평균은 $107.5{\pm}65.2$초였고, 확진검사인 청성뇌유발전위 검사를 실시하는 데 소요된 총 시간의 평균은 $1,500{\pm}90.1$초가 소요되었다. 5. 연구를 진행하는 도중 11명의 고위험군 신생아가 이사, 연락처 변경, 경제적 사정으로 추적검사에 참여하지 않았다. 신생아 난청은 다른 질병에 비해 발병률이 높은 선천성 질환으로서 모든 신생아를 대상으로 청각검사를 실시하여 난청의 조기진단에 대한 선별검사의 정착이 필요하다고 생각된다.

  • PDF

Health status of children in low socioeconomic conditions (공부방을 이용하는 저소득층 소아들의 건강상태에 대한 조사)

  • Choi, Hee Kyoung;Her, Jeong A;Jang, Seong Hee;Kim, Dal Hyun;Yoon, Kyoung Lim;Ahn, Young Min
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.1
    • /
    • pp.24-28
    • /
    • 2006
  • Purpose : The purpose of this study was to investigate the health status and nutritional condition of children living in a low-income community through anthropometric, laboratory evaluation. Methods : A community-based survey identified children below 15 years living in a low-income community. Their weight, height, visual acuity, hearing level and dental status were measured. Blood sample were obtained on June and July, 2004. Hemoglobin, serum cholesterol, Hepatitis B antigen/antibody, AST and ALT were measured. Results : A total of 285 students(M : F=141 : 144) aged 6 to 14 years were included in this study. The heights and weights in some grades were smaller than controls. The prevalence of obesity was 10.6 percent in males and 10.7 percent in females. The prevalence of abnormal visual acuity, hearing impairments and dental carries were 20.5 percent, 0.3 percent and 69.4 percent. The prevalence of anemia was 10.1 percent. Serum total cholesterol was over 200 mg/dL in 7 percent. They complained of abdominal pain(22.1 percent) and headache(17.1 percent). Hyperthyroidism, cataract, neurofibromatosis, severe atopic dermatitis, ventricular septal defect, strabismus and inguinal hernia were newly diagnosed. Conclusion : Mean heights and weights of children in the low-income community were smaller than controls. The prevalence of abnormal visual acuity, hearing impairment and dental carries were higher than in the 2003 national health survey. Additional research is needed to evaluate the health status of the low-income community.

Acoustic Masking Effect That Can Be Occurred by Speech Contrast Enhancement in Hearing Aids (보청기에서 음성 대비 강조에 의해 발생할 수 있는 마스킹 현상)

  • Jeon, Y.Y.;Yang, D.G.;Bang, D.H.;Kil, S.K.;Lee, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.1 no.1
    • /
    • pp.21-28
    • /
    • 2007
  • In most of hearing aids, amplification algorithms are used to compensate hearing loss, noise and feedback reduction algorithms are used and to increase the perception of speeches contrast enhancement algorithms are used. However, acoustic masking effect is occurred between formants if contrast is enhanced excessively. To confirm the masking effect in speeches, the experiment are composed of 6 tests; test pure tone test, speech reception test, word recognition test, pure tone masking test, formant pure tone masking test and speech masking test, and for objective evaluation, LLR is introduced. As a result of normal hearing subjects and hearing impaired subjects, more making is occurred in hearing impaired subjects than normal hearing subjects when using pure tone, and in the speech masking test, speech reception is also lower in hearing impaired subjects than in normal hearing subjects. This means that acoustic masking effect rather than distortion influences speech perception. So it is required to check the characteristics of masking effect before wearing a hearing aid and to apply this characteristics to fitting curve.

  • PDF

Ototoxic Evaluation of Cis-platinum (Cis-Platinum의 이중독증에 관한 임상적 고찰)

  • 홍원표;정명현;오혜경;이경재
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.17.1-17
    • /
    • 1982
  • In 1965, Rosenberg reported that platinum compounds not only inhibit growth and cell division of E. coli but also has anti-tumor activity. Since then, through animal and clinical experiments by Welsch(1971), Speer(1972), Rossof(1972), Hill(1974), and Wittes(1975), it was proved that Cis-platinum has excellent supressive effects on malignant tumor, especially on head and neck cancer. Accordingly, Cis-platinum is now widely used, sometimes without any other durg, or sometimes with Bleomycin and Methotrexate etc. Inspite of the strong anticancer effect, the use of Cis-platinum is quite often discouraged because of the reports that Cis-platinum causes auditory impairment at high frequencies above the speech range due to inner ear damage and irreversible change in the renal tubules. Since Kohonen et al(1965), Standnicki et al(1974) reported that Cisplatinum has toxic effects at the basal turn of the cochlea using guinea pig, many studies on ototoxicity after infusion of Cis-platinum have been carried out using animals. But the studies on ototoxicity in human beings can hardly be found except in reports by Piel et al(1974) and Hong et al (1979). So the authors did a study which tried to clarify the ototoxic effect by comparing the hearing level after infusion of Cis-plastinum with the hearing level before infusion of Cis-plastinum in 30 patients who was treated with Cis-platinum and admitted to the dept. of otolaryngology of Yonsei University Hospital during 2 years and a half from July. 1979 to March. 1982 and the following results were obtained. 1) The results of auditory evaluation, using the pure tone average, hearing loss of 4kHz and 8kHz, Speech Reception Threshold, PB score, SISI showed that the difference of dosage does not change the hearing level after infusion of Cis-platinum and before infusion of Cis-platinum. 2) Cis-platinum had no effect on the hearing level of patients with conductive hearing loss, or with sensorineural hearing loss, as well as with normal hearing level. 3) The infusion of Cis-platinum did not cause any change in creatinine clearance, creatinine, uric acid, but only one case showed that Cis-platinum caused severe nephrotoxicity. 4) The infusion of Cis-plastinum did not cause any change in hemoglobin, leukocyte count, platelet count and there was no correlation with the amount of infusion. 5) To see the side effect of hydration practiced with the infusion of Cis-platinum, the electrolytes, particularly the K level in the serum was measured. But the results did not show any change. 6) Judging from the results of this study mentioned above, ototoxicity caused by infusion of Cis-platinum can be prevented by sufficient hydration. Also the results might say that the appropriate method of infusion of Cis-platinum might be effective in the patients with head and neck cancer who had sensorineural hearing loss for whom the infusion of Cis-platinum has been absolutely cotraindicated.

  • PDF