• Title/Summary/Keyword: 철근콘크리트구조물

Search Result 1,425, Processing Time 0.025 seconds

A Study on the Permeability through Concrete using RF Wireless Module for Reinforced Concrete Structure (철근콘크리트 구조물에 내제된 RF 무선송수신 모듈의 콘크리트 투과성 실험 연구)

  • Jo, Byung-Wan;Park, Jung-Hoon;Yoon, Kwang-Won;Kim, Heoun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2D
    • /
    • pp.295-302
    • /
    • 2011
  • Ubiquitous is an information communication environment which peoples could connect on network without being conscious of the network and computer condition at anytime and anywhere. Presently, advanced technology, digital cities and eco-friendly cities using Ubiquitous technology are being focused through out the world. As recent information industry and communication technology have developed remarkably, studies on intelligent structures and structural maintenance methods by combining a general idea of connecting all objects on network by interpolating computers which is called Ubiquitous Computing, and USN(Ubiquitous Sensor Network) are being attempted. In this paper, a basic experiment on penetration of RF(Radio Frequency) sensor nodes using an experimental sample setting concrete and reinforcing bar as variables is studied to estimate the possibility of applying wireless sensor networks in structures. The spring of reinforcing bars, concrete thickness, intensity of radio frequency were set up as variables, transmitting and receiving distance were checked vertically and horizontally. Moreover, Spectrum Analyzer was used for checking the magnitude of the frequency used in order to measure the reduction of radio wave exactly. The radio wave reduction was numerically analyzed, and the influence of the wavelength was analysed as well. As a result, the penetration depth in concrete without reinforcing bars was 45cm, and in reinforced concretes which reinforcing bars placed at spacing of 5cm and 15cm, the penetration depth were 37cm and 45cm each. No influence on radio wave penetration depth were found when the spacing of reinforcing bars in the reinforced concrete structures becomes over 15cm.

Seismic Performance Evaluation of Reinforced Concrete Frames Reinforced with Chevron Bracing System (역V형 가새로 보강된 RC 골조의 내진성능평가)

  • Ha, Heonjun;Oh, Keunyeong;Lee, Kangmin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.13-22
    • /
    • 2018
  • In this study, seismic performance of existing RC frames reinforced with steel chevron bracing systems was experimentally evaluated. For this purpose, the unreinforced base specimen and seismically reinforced specimens with steel chevron bracing systems were fabricated and tested. Both strength and stiffness of the reinforced specimens were targeted about 2-3 times larger than the base specimen. Test results showed that the stiffness, strength, and ductility of the reinforced specimens considerably improved than those of unreinforced base specimen. Therefore, the results from this study could offer the basic information on the developing design guideline for the seismic reinforcement of RC frames.

Evaluation on Performance of Surface Protectors for Protecting Reinforced Concrete Structures (철근 콘크리트 구조물을 보호하기 위한 표면 보호재의 성능 평가)

  • An, Young-Ki;Jang, Suk-Hwan;Chung, Young-Jun;Nam, Yong-Hyuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.1
    • /
    • pp.217-223
    • /
    • 2005
  • This study is on the evaluation of three kinds of surface protectors for protecting reinforced concrete against corrosion of reinforcing steel by chloride attack and carbonation. In this study, the test has been carried out on the performance of specimens applied with surface protectors for anti-corrosion and anti-carbonation. The result showed that specimens applied with the three kinds of surface protectors, were excellent in resistance to the corrosion of reinforcing steel and carbonation. Especially the specimen applied with finish coating in conjunction with hydrophobic primer showed great reduction in the corrosion of reinforcing steel and carbonation.

Determination of Structural Capacity Based on Deformation and Bond Strength for RC Structure at Steel Corrosion (변형과 부착강도 기반 철근 부식에 의한 RC구조물의 구조적 성능 평가)

  • Jung Wook Lee;Ki Yong Ann
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.449-457
    • /
    • 2023
  • In this study, the structural limit for concrete was experimentally determined against corrosion of steel. The structural limit was taken as (1) the deformation of concrete at yielding, (2) the maximum pull-out strength and (3) the pull-out strength at the level for uncorroded specimen. Corrosion of steel was accelerated by extracting charges from steel surface to govern degree of steel corrosion. As a result, an increase in the steel diameter resulted in an increase in the corrosion degree to reach the concrete deformation at yielding. Again, an increase in the steel diameter resulted in an increase in the extracted charge to meet the maximum and uncorroded-equivalent level for the bond strength. However, the mass loss was marginally affected by the steel size, reflecting that these parameters could be used to alert the structural limit.

An Experimental Study on Chloride Ions Penetration of Mortar containing Si/Al Hybrid-Inorganic Salt (Si/Al 복합 무기염을 적용한 모르타르의 염소이온침투깊이에 대한 실험적 연구)

  • Khil, Bae-Su;Kim, Do-Su;Kang, Yong-Sik;Kim, Woo-Jae;Choi, Se-Jin;Kim, Sung-Su
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.417-418
    • /
    • 2009
  • As iron corrosion by means of penetration of chlorides resulted in a serious deterioration of seaside and landfill concrete construction, it is urgently necessary for seaside construction to acquire watertightness and resistance for chloride-attack. Hence in this study, Si/Al liquor type hybrid-inorganic salt which was very effective compound for improving resistance for chloride-attack applied to mortar and then evaluated resistance for chloride-attack with curing(7, 14, 28, 56 days).

  • PDF

Investigation of Material Characteristics of Reinforced Concrete Beam After Exposure to Fire Test (화재 실험에 따른 철근 콘크리트 보의 재료특성 연구)

  • Ju, Min-Kwan;Park, Cheol-Woo;Oh, Ji-Hyun;Seo, Sang-Gil;Shim, Jae-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.3
    • /
    • pp.33-41
    • /
    • 2016
  • Concrete is inherently a good fire-resistance material among all other constrcution materials and protects the reinforcing steel inside. This study investigates the material characteristics of concrete and steel bar inside the full scale reinforced concrete(RC) beam exposed to fire test. The fire test specimen was 4 m long and the test was conducted under no loading condition following KS F 2257. Fire source is simulated by ISO 834 and number of thermocouples were installed to measure temperature variation of surfaces and inside of the beam. The measured compressive strength of cored specimen, which was exposed to fire test, was 11 MPa, about 66% lower than the strength before exposure. The yielding strength of steel bar also decreased about 75 MPa, about 17% lower. The measured temperature of protected steel bar was around $649^{\circ}C$, the critical limit, after 4 hour exposure.

Design Equation Suggestion through Parametric Study of Laterally Restrained Concrete Decks with Steel Strap (Steel Strap으로 횡보강된 콘크리트 바닥판의 매개변수해석을 통한 설계식 제안)

  • Kim, Cheol-Hwan;Yi, Seong-Tae;Jo, Byung-Wan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.49-57
    • /
    • 2014
  • A deterioration of typical reinforced concrete (RC) bridge deck is due to the use of calcium chloride, cracks and water penetration inside of the deck slab with steel reinforcement. In order to eliminate the defects of RC decks in terms of material, therefore, the steel-strapped deck system is studied and developed by maximizing the arching effect while the girders are restrained using straps in lateral direction to the bridge. This parametric study was performed to analyze the structural characteristics of steel-strapped deck, and to identify the factors of the thickness, span length and lateral restraint stiffness of deck slab considering the concrete non-linearity. Finally, a design equation, which is adequate to South Korea, is suggested.