• Title/Summary/Keyword: 처짐식

Search Result 152, Processing Time 0.041 seconds

The Determination of Critical Buckling Load Applied to Tapered Columns (일정변단면(一定變斷面) 장주(長柱)의 임계좌굴하중(臨界挫屈荷重)의 결정(決定))

  • Yu, Chul Soo;Sohn, Sung Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.1
    • /
    • pp.93-101
    • /
    • 1984
  • New formulas to determine the critical elastic buckling load of long tapered columns are given. This study is restricted to solid round or rectangular columns with fixed-free ends as often used in highway design. The exact solution of the differential equation of the deflection curve is expressed in terms of Bessel Function and the solution is numerically evaluated using Bisection method by computer. In the F.E.M analysis of columns under their own weight, the stability problem can be resulted in a eigen value problem of conservative system. Approximate solution by the F.E.M is evaluted numerically using Jacobi method and compared with exact solution of the prismatic column to increase the precision. In addition, critical buckling load of the tapered column for every shape factor and ratio of cross-sectional change (Diameter of bottom end/Diameter of upper end) was converted into a comparable expression to critical buckling load of the prismatic column.

  • PDF

Thickness Measure and Characteristic Length for Effective Young's Modulus of Model Ice Plate in the Ice Basin (빙해수조 모형빙판의 두께 계측과 유효탄성계수용 특성길이 연구)

  • Lee, Jae-Hwan;Choi, Bong-Kyun;Lee, Chun-Ju
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.5
    • /
    • pp.353-360
    • /
    • 2014
  • The model ice is created at KRISO (Korea Research Institute for Ships and Ocean Engineering) ice basin where model ship is tested to obtain the necessary data in order to design the ice breaking vessels and ocean structures operating in the northern pole sea area. Through the model ship test, ice breaking, clearing, ice-ship and ice-propeller interaction behavior can be obtained. Since mechanical properties of ice plate are required for the model test, some tests are performed to obtain the properties in this paper. First, ultrasonic devide is used to measure the thickness of the model ice plate and the results show the possibility of using ultrasonic method, yet more sophisticated device or special sensors are required to measure the ice thickness completely. And the defection of ice plate is measured using LVDT to compute the characteristic length of ice plate on the fluid, which is used to get the effective Young's modulus of model ice.

Dynamic Analysis of Prestressed Liquid Storage Tanks Considering Fluid Effect (유체의 영향을 고려한 프리스트레스트 액체저장 탱크의 동적해석)

  • 황철성;백인열
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.4
    • /
    • pp.71-82
    • /
    • 1999
  • An axisymmetric shell element which includes the effects of the meridional and circumferential cable prestresses is developed. The fluid-structure interaction is expressed as added mass effect which is in proportion to the acceleration of the structure in interface surface. The added mass is obtained by using finite element method under the assumption that the fluid is invicid, incompressible and irrotational. It is coded for personal computer by the maximum use of axisymmetic properties and the dynamic analysis are performed under seismic exitations. A ring element makes the characteristics of the axisymmetric shell to be fully utilized. The elgenvalue solutons under the initial prestresses and the internal fluid are well agreed with the exact solutions and references by using under 20 elements. The eigenvalues are decreased along the increasing the height of internal fluid and these effects are dominant under the lower wave numbers. The results of the seismic analysis show that the radial deflection under the meridional prestress is a little larger than that under the circumferential prestress.

  • PDF

Flexural Behavior of Concrete Beams Reinforced with CFRP rebars (CFRP Rebar로 보강한 콘크리트 보의 휨 거동)

  • Lee, Young-Hak;Won, Dong-Min;Kim, Min-Sook;Kim, Hee-Cheul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.43-50
    • /
    • 2010
  • To address the problems caused by the corrosion of steel rebar, active research has recently been carried out on members where fiber-reinforced polymer (FRP) is used in place of rebar. As FRP bar is highly brittle and has a low modulus of elasticity, further research is needed on the evaluation of serviceability, in other words on the deflection of flexural concrete members reinforced with FRP rebars. Taking the reinforcement ratio as a variable, this paper analyzes the flexural capacity of concrete beams reinforced with CFRP rebar. The test results of specimens reinforced with CFRP rebar show an increase in stiffness and resisting force along with an increase in the reinforcement ratio. A reinforcement ratio of about 1.3 is needed for the member reinforced with CFRP rebar to show same section property of a steel member. Through a comparison for the value of an effective moment of inertia, the equation suggested by Bischoff & Scanlon predicted values closest to the actual results.

Closing Step Analysis in Cable-Stayed Bridges to Produce Initial Equilibrium Condition (초기평형상태 구현을 위한 사장교의 폐합단계 해석)

  • Park, Yong Myung;Yun, Jae Sun;Cho, Hyun Jun;Park, Chung Gon
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.2
    • /
    • pp.191-199
    • /
    • 2007
  • This paper presents a closing method for a cable-stayed bridge erected by the free cantilever method to produce the initial equilibrium configuration at the final construction stage. To realize the initial equilibrium condition in cable-stayed bridge by the cantilever method, compatibility conditions for vertical displacements, rotational angles, and axial displacements at the closing section of both side girders should be satisfied. In this paper, it was shown that it can be accomplished by using some applicable loads during construction such as the pull-up force of the derrick crane, some cable tension forces, and jacking force at the pylon. The proposed method was applied to a construction stage analysis of a sample bridge to demonstrate its validity, and it was acknowledged that the tower was considerably affected by the compatibility condition for axial displacement in the closing step.

Applicability Analysis of the FE Analysis Method Based on the Empirical Equation for Near-field Explosions (근거리 폭발에 대한 경험식 기반 유한요소해석 방법의 적용성 분석)

  • Hyun-Seop, Shin;Sung-Wook, Kim;Jae-Heum, Moon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.6
    • /
    • pp.333-342
    • /
    • 2022
  • The blast analysis method entails the use of an empirical equation and application of the pressure-time history curve as an explosive load. Although this method is efficient owing to its simple model and short run time, previous studies indicate that it may not be appropriate for near-field explosions. In this study, we investigated why different results were observed for the analysis method by considering an RC beam under near-field explosion conditions with the scaled distance of 0.4-1.0 as an example. On this basis, we examined the application range of the empirical analysis method by using the finite element analysis program LS-DYNA. The results indicate that the empirical analysis method based on data from far-field explosion tests underestimates the impulse. Thus, the calculated deflection of the RC beam would be smaller than the measured deflection and arbitrary Lagrangian-Eulerian (ALE) analysis result. The ALE analysis method is more suitable for near-field explosion conditions wherein the structural responses are large.

Evaluation Techniques for Residual Structural Performance of a Reinforced Concrete slab under Fire Damage (화재 피해를 입은 철근콘크리트 슬래브의 잔존 구조성능 평가기법)

  • Choi, Kwang-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.588-594
    • /
    • 2020
  • This study proposes non-destructive rebound-hardness and ultrasonic testing methods to more accurately evaluate the residual structural performance of reinforced concrete structures in a fire. Techniques are also proposed to assess the stiffness used in the deflection calculation with natural frequencies obtained by vibration tests. In the compressive strength evaluation using rebound hardness, the residual compressive strength of thick specimens and a larger water/cement (W/C) ratio were shown to be large. The homogeneity of concrete at high temperature compared to ambient temperature conditions was assessed by the velocity of ultrasonic waves that penetrate the concrete, and it followed W/C or thickness of slab makes little different results. To assess the stiffness of fire-damaged slabs and increase in deflection, the natural frequency was measured by vibration tests and incorporated into the equation of the stiffness. The application of this technique to the slab experiment showed that it can be a very reasonable evaluation technique. In addition, to evaluate the residual strength of a member after fire, a test of the strength of a component was carried out during and after heating.

A Study on the Applicability of Partial Post-Tension Slab with Top Anchorage System (상향긴장식 부분PT를 사용한 슬래브의 적용성 분석)

  • Lee, Deuck-Hang;Kim, Kang-Su;Kim, Chang-Hyuk;Kim, Sang-Sik;Kim, Yong-Nam;Chung, Kwang-Ryang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.309-312
    • /
    • 2008
  • Reinforced concrete (RC) structures have been most widely used because of the economic efficiency. However, it is very weak to tensile stresses and difficult to control deflection due to the heavy self-weight of concrete. Although it is generally known that prestressed concrete structures can be the most effective to overcome the demerit of RC structures, its application is very seldom in domestic construction for the difficult onsite circumstances. The post-tension method, which is well fit for buildings that are mostly indeterminate structures and beneficial for monolithic construction, has been introduced to just a few building construction. The application of full PT method into entire spans makes construction engineers feel very difficult due to the lack of current condition in construction fields. Therefore, this study proposed the partially applied PT method as an alternative, which can improve the deflection control of RC structures and reduce the construction difficulty by applying the PT method in a part of span length as needed, and analyzed its characteristics of structural behavior. In this study, the top anchorage was applied to improve the applicability of partial PT method, and the analysis results of slab behavior were compared to the measured values obtained from the post-tensioned slab constructed by the partial PT method.

  • PDF

Bond Strength Evaluation of RC Beams on the Rib Shape of Reinforcing Bars (철근 마디 형상에 따른 RC 휨부재의 부착강도 평가)

  • Hong, Geon-Ho;Kim, Jin-Ah;Choi, Oan-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.393-400
    • /
    • 2011
  • The needs for high strength structural materials have recently increased, because construction and cost efficiencies are demanded by the costumers. But, the use of high strength reinforcing bars requires longer development and splice lengths compared to normal strength bars. This restriction may cause reduction in construction efficiency and require more complicated details. The purpose of this paper is to evaluate the bond strength on the rib shape of reinforcing bars to decrease development and splice lengths of high strength reinforcements. Total of 5 simple beam specimens were tested, and the main test variable was a rib shape of reinforcing bars. Test data was analyzed in the viewpoint of bond strength, load-deflection relationship, and crack pattern. Test results indicated that the bond strength of high relative rib area reinforcing bars increased up to 11% compared to normal strength reinforcements. And the improved rib shape reinforcements, which were formed with high and low height rib, increased the bond strength up to 23% even though the relative rib area was same as the high relative rib area reinforcements. Serviceability performances such as deflection number of cracking, and maximum crack width were similar in all specimens, so it is safe to conclude that the improved rib shape reinforcements can be applied to the structural members.

Creep Behavior of Pultruded Ribbed GFRP Rebar and GFRP Reinforced Concrete Member (인발성형된 이형 GFRP 보강근과 GFRP 보강 콘크리트 부재의 크리프 거동)

  • You, Young-Jun;Park, Young-Hwan;Kim, Hyung-Yeol;Choi, Jin-Won;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.2
    • /
    • pp.187-194
    • /
    • 2013
  • Fiber reinforced polymer (FRP) has been gathering interest from designers and engineers for its possible usage as a replacement reinforcement of a steel reinforcing bar due to its advantageous characteristics such as high tensile strength, non-corrosive material, etc. Since it is manufactured with various contents ratios, fiber types, and shapes without any general specification, test results for concrete members reinforced with these FRP reinforcing bars could not be systematically used. Moreover, since investigations for FRP reinforced members have mainly focused on short-term behavior, the purpose of this study is to evaluate long-term behaviors of glass FRP (GFRP) reinforcing bar and concrete beams reinforced with GFRP. In this paper, test results of tensile and bond performance of GFRP reinforcing bar and creep behavior are presented. In the creep tests, results showed that 100 years of service time can be secured when sustained load level is below 55% of tensile strength of GFRP reinforcing bar. A modification factor of 0.73 used to calculate long-term deflection of GFRP reinforced beams was acquired from the creep tests for GFRP reinforced concrete beams. It is expected that these test results would give more useful information for design of FRP reinforced members.