• Title/Summary/Keyword: 차폐 콘크리트

Search Result 115, Processing Time 0.022 seconds

Shielding Analysis of the Material and Thickness of Syringe Shield on the Radionuclide (방사성 핵종별 주사기 차폐기구의 재질 및 두께에 대한 차폐분석)

  • Cho, Yong-In;Kim, Chang-Soo;Kang, Se-Sik;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.7
    • /
    • pp.282-288
    • /
    • 2015
  • A monte carlo simulation about shielding material and thickness of the syringe shield for radiation shield was performed. As a result of analysis, high atomic number materials such as tungsten, lead and bismuth have the highest shielding effect. However, $^{18}F$, $^{67}Ga$ and $^{111}In$ show high energy distribution in the region with thin shielding thickness. As the thickness of shielding materials increased, the energy distribution decreased due to reduction of ${\gamma}$-ray. In the case of low atomic number materials, they, showed energy distribution from highest to lowest, were barium sulfate, steel, stainless, iron and copper. Aluminum, plastic, concrete and water showed diverse aspect. they showed relatively high energy distribution because of increased ${\gamma}$-ray that penetrate the shield.

A study on the Mechanical Properties of Concrete using Electronic Waste as Fine Aggregate (전자폐기물을 잔골재로 적용한 콘크리트의 역학적 특성에 관한 연구)

  • Kim, Yong-Moo;Choi, So-Yeong;Kim, Il-Sun;Yang, Eun-Ik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.2
    • /
    • pp.90-97
    • /
    • 2018
  • The quantities of electronic waste have been increased rapidly, and was caused variety problems such as environmental pollution or dissipation of resource. So, it needed to development of recycling technology about heavy metal in the electronic waste. Meanwhile, filler material (concrete or mortar) was used for shielding radioactive waste, however, it did not used materials that it is proved radiation shielding performance. So, there is a lack of confidence in the shielding performance. Therefore, in this paper, mechanical properties of concrete was evaluated for the applicability using electronic waste as fine aggregate of filler material. From the test results, compressive and flexural strength and elasticity modulus and the micro pore in the $1{\mu}m$ range was significantly affected by substitution of electronic waste, however, it could be improved the performance by using mineral admixture as binder. So, it is shown that the electronic waste could be applicable as fine aggregate of filler material.

A Study on Calculation of the Thickness of Concrete Protective Barrier of X-ray Radiographic Room (X선촬영실의 콘크리트 방어벽 두께 계산에 관한 연구)

  • Park, Cheol-Seo
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.363-367
    • /
    • 2010
  • In this paper we proposed an easy method to calculate the thickness of primary protective barrier for radiographic equipment. The concrete was selected for the shielding material. The area of protective barrier was divided into a controlled area and a noncontrolled area. For the computation of thickness, the data in NCRP Report 49 and 51 was used. For radiographic equipments whose maximum tubevoltages are 100 and 150 kVp, the thicknesses of concrete were calculated as a function of distance. From the calculated data, four analytical models were acquired by fitting an exponential decay function. From the equations acquired by this study, the thickness of primary protective barrier can be calculated approximately.

The consideration about the shielding effect of LEDITE (LEDITE를 이용한 방사선 차폐시설에 관한 고찰)

  • Min Je-soon;Lee Je-hee;Park heung-deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.11-18
    • /
    • 2003
  • The concrete is usually used to build a radiation therapy facility and the enough concrete thickness for high energy x-ray beam is about 1 meter. But if the space is not enough to build a radiation therapy facility with concrete, the substitute for concrete is needed, and the Ledite can be a good substitute for concrete. In this study, we compared the Ledite with the concrete. The comparing list are the needed shielding thickness, the period of construction and the cost.

  • PDF

An Experimental Study on the Development of Electro Magnetic Pulse Shielding Cement Using Milled Carbon Fiber (저 직경 카본섬유를 사용한 전자기 펄스 차폐 시멘트 개발에 관한 실험적 연구)

  • Min, Tae-Beom
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.4
    • /
    • pp.429-435
    • /
    • 2020
  • In this study, physical properties and EMP shielding performance evaluation of cement paste according to the amount of milled carbon fiber was conducted to develop EMP shielding cement using carbon fiber. The length of the milled carbon fiber used was 100㎛, and it was used as a cement admixture because it showed a powdery form to the naked eye. As a result of the experiment, when 5% of the amount of cement was used, the milled carbon fiber was effective in compressive strength and EMP shielding, and the shielding effect did not increase when used beyond that. As a result of examining the EMP shielding performance according to the thickness of the specimen, the plain without milled carbon fiber had no effect of increasing the shielding rate according to the thickness. The shielding performance of the specimens using the milled carbon fiber increased as the thickness increased. Therefore, in order to increase the EMP shielding rate when comparing and evaluating the performance according to the amount of milled carbon fiber used and the thickness of the specimen, 5% of the milled carbon fiber used is optimal. In addition, the method of increasing the thickness is considered to be effective.

Neutron Shielding Performance of Mortar Containing Synthetic High Polymers and Boron Carbide (합성 고분자 화합물 및 탄화붕소 혼입에 따른 모르타르의 중성자 차폐성능 분석)

  • Min, Ji-Young;Lee, Bin-Na;Lee, Jong-Suk;Lee, Jang-Hwa
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.2
    • /
    • pp.197-204
    • /
    • 2016
  • Concrete walls of neutron generating facilities such as fusion reactors and fission reactors become radioactive by neutron irradiation. Both low-activation and neutron shielding are a critical concern at the dismantling stage after the shutdown of facilities with a requirement of radioactive waste management. To tackle this, two types of additives were investigated in fabricating mortar specimens: synthetic high polymers and boron carbide. It is well known that a hydrogen atom is effective in neutron shielding by an elastic scattering because its mass is almost the same as that of the neutron. And boron is an effective neutron absorber with a big neutron absorption cross section. In this study, the effect of the type, shape, and size of polymers were investigated as well as that of boron carbide. Total 16 mix designs were prepared to reveal the effect of polymers on mechanical properties and neutron shielding performance. The neutron does equivalent of polymers-based mortar for fast neutrons decreased by 36 %, and the count rate of boron carbide-based mortar with regard to thermal neutrons decreased by 90 % compared to conventional mortar. These results showed that a combination of polymers and boron carbide compounds has potential to reduce the thickness of neutron shields as well as radioactive waste from reactors.

Evaluation of Electromagnetic Pulse Shielding Effectiveness and Bonding Performance of Inorganic Paint based on Carbon Material (탄소재료 기반 무기계 도료의 전자파 차폐성능 및 부착성능 평가)

  • Jang, Kyong-Pil;Kim, Sang-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.801-807
    • /
    • 2021
  • In various industrial fields and infrastructure based on electronic components, such as communication equipment, transportation, computer networks, and military equipment, the need for electromagnetic pulse shielding has increased. Two methods for applying electromagnetic pulse shielding are effective. The first is construction using shielding materials, such as shielding concrete, shielding doors, and shielding windows. The other is coating shielding paints on non-shielding structures. Electromagnetic pulse shielding paints are made using conductive materials, such as carbon nanotubes, graphite, carbon black, and carbon fiber. In this paint, electromagnetic pulse shielding performance is added to the commonly used water-based paint. In this study, the shielding effectiveness and bonding performance of paints using conductive graphite and carbon black as shielding materials were evaluated to develop electromagnetic pulse shielding inorganic paints. The shielding effectiveness and bonding performance were evaluated by applying six mixtures composed of different kinds and amounts of shielding material. The mixture of conductive graphite and carbon black at a weight ratio of 1:0.2 was the most effective in shielding as 33.6 dB. Furthermore, the mixture produced using conductive graphite only showed the highest bonding performance of 1.06 MPa.

A Literature Review and Experimental Study of Basic Physical Properties about Electromagnetic Shielding Concrete Development (전자파 차폐용 콘크리트 개발에 관한 문헌조사 및 기초물성 연구)

  • Choi, Hyun-Jun;Choi, Hyun-Kuk;Lim, Sang-Woo;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.41-42
    • /
    • 2016
  • In this study, the basic properties of concrete with entrained materials as shielding material for electromagnetic pulse(EMP) within 10kHz~1GHz were investigated. The concretes of moderate strength were prepared with different entrained materials. The shielding effectiveness will be determined according to MIL-STD-188-125-1 at 28 days of concrete curing. The results of physical properties were all satisfied of setting criteria.

  • PDF

An Experimental Study on Alkali-Silica Reaction due to Neutron Shielding Concrete Containing Borosilicate Glass Powder (붕규산 유리 분말을 혼입한 차폐용 콘크리트의 알칼리 실리카 반응에 의한 팽창 실험)

  • Jang, Bo-Kil;Kim, Ji-Hyun;Chung, Chul-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.160-161
    • /
    • 2015
  • Borosilicate glass can be used for improving neutron shielding of concrete. The well known expansion of borosilicate glass caused by expansion of mortar bar was can cause serious damage to the concrete. In this research, borosilicate glass was powdered to reduce the particle size similar to that of cement, and 20% cement replacement set was reduced expansion rate about 30%. But aggregate replacement set was damaged because of Alkali-Silica Reaction expansion.

  • PDF

A Study on the EMP Shielding and Physical Properties of Concrete using Electric Arc Furnace Oxidizing Slag aggregate (전기로산화슬래그 골재를 사용한 콘크리트의 EMP 차폐 및 물리적 특성에 관한 연구)

  • Min, Tae-Beom;Lee, Min-Seog;Kim, Hyeong-Cheol;Kim, Jae-Young;Choi, Hyun-Kuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.177-178
    • /
    • 2020
  • The EMP slip rate was compared with the general concrete using the electric arc furnace slag as an aggregate. Experimental results show that the shielding rate of concrete specimens using electric arc furnace slag increases. It is considered that the shielding rate is increased due to the high Fe content in the components of the electric arc furnace slag aggregate.

  • PDF