• Title/Summary/Keyword: 차폐 성능

Search Result 263, Processing Time 0.031 seconds

Technical trend of Surface treatment for FPCB (FPCB표면처리와 최신기술개발동향)

  • Kim, Yu-Sang
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.05a
    • /
    • pp.291-292
    • /
    • 2012
  • 플렉시블 (F-PCB, Flexible Printed Circuit Board)은 얇고 유연하며 모바일, 광학, 노트북, 프린터, LCD 등 IT산업전반에 걸쳐 사용되고 있다. 통신기기가 이동용으로 전환되면서 대용량, 고속의 정보 전달이 필요하다. 인접 회로간의 전자파 차폐, 구리성분의 편석방지와 고성능의 회로소재 확보가 요구된다. 본고에서는 최근의 플렉시블 인쇄회로기판의 주석도금의 위스커방지 품질향상을 중심으로 기술하였다.

  • PDF

Performance Evaluation on the Reinforcing Material of Plastic Composites for the Electromagnetic Shielding (전자차폐(電磁遮蔽)를 위한 플라스틱 복합재료용(複合材料用) 강화재(强化材)의 성능평가(性能評價))

  • Kim, Dong-Jin;Murakami, Ri-ichi
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.6 s.165
    • /
    • pp.1048-1054
    • /
    • 1999
  • It is important to study the shielding effectiveness(SE) of reinforcing material of plastic composite materials against the electromagnetic(EM) waves. In this paper, SE of the shielding material of EM waves was investigated with actual experiments. The materials used in this study were made up of film, fiber and powder of conductive materials - Cu, Al, CF etc. Also, The resin film was used as matrix. The experiment was carried out by using a shielding evaluator(Shielding box) TR17302 with an ADVANTEST spectrum analyzer, model R3361C. It was found from the experimental results that copper, aluminum and carbon fiber were good candidates as a shielding material against the EM waves with increasing the SE as the composite was laminated. The characteristics of the SE against the EM waves depended on a mode of preparation of specimen. The effects of interval of wires on the SE were studied when the orientation and the space of Cu wires were changed. The SE strongly depended on the. orientation and the space of the Cu wire. SE decreased as the space of the Cu wires was increasing.

Acoustic Performance of the Multilayered Panel with Helmholtz Resonators (Helmholtz 공명기를 내장한 다층패널의 음향 특성에 관한 연구)

  • Jong-Soo Seo;Jae-Jin Jeon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.29 no.1
    • /
    • pp.123-134
    • /
    • 1992
  • The reduction of the airborne noise level is essential to the comfortability for mien and passengers in ships. In this paper, the acoustic characteristics on the multilayered acoustic panel with the Helmholtz resonator was described analytically and experimentally. The design software based on the Transfer Matrix Analysis(TMA) method for the acoustic enclosing panel was developed. According to the change of the design parameters of the panel, verious transmission losses were obtained using the developed software. As a result, it was verified that the acoustic characteristics of the composite panel was excellent in comparison with the conventional acoustic partitioning structures. This panel can be applicable to the acoustic enclosure system.

  • PDF

Evaluation of Tungsten Blended Filament Shields Made by 3D Printer in Radiography (일반촬영분야에서의 3D 프린터로 제작한 텅스텐 혼합 필라멘트 차폐체의 성능평가)

  • Yoon, Joon;Yoon, Myenog-Seong
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.615-621
    • /
    • 2021
  • In the medical field, radiation provides information for the diagnosis and treatment of diseases. As the use of radiation increases and the risk of exposure increases, interest in radiation protection is also rapidly increasing. Lead shielding material is mainly used, which has a risk of lead poisoning and absorption into the body. Tungsten mixed filament shielding sheets were fabricated with a size of 70 × 70 mm and a thickness of 1, 2, and 4 mm by using a 3D printer. In the general shooting experiment, the thickness of the shielding sheet is 1 ~ 5mm, the tube voltage is 60, 80, 100, 120 kVp and the tube current is 20, 40 mAs. In general photography, Tungsten showed better shielding rate compared to Brass, Copper, and Lead protective tools under all irradiation conditions, and in particular, Tungsten 5 mm showed 100% shielding rate. The 3D-printed tungsten mixed filament shielding is expected to be used as a new shield that can replace the existing lead protection tools as it shows a better shielding rate than the existing lead protection tools in Radiography.

강자성체를 이용한 연속 가변 토크 제어 전달 기구의 개발

  • Seo, Hyo-Jeong;An, Jae-Yeong;Myeong, Jin-Sol;Ju, Jeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.140-140
    • /
    • 2017
  • 4륜 장착 자동차의 토크 전달은 2륜 구동, 4륜 구동 모드를 간단히 전환하는 방식(part time 4WD)과 항시 사륜 구동 모드에서 전후륜의 토크 전달비를 제어하는 방식(AWD, all wheel drive)이 있다. 경제의 발달에 따라서 취미 인구의 확대로 국내에만 180만 명의 R/C car 사용자가 있다. 이 중 2WD-4WD의 전환을 differential lock mechanism으로 구현한 수입산 모델의 가격이 1,000,000원을 호가하지만 가변 제어 방식이 아닌, 정차 후 2-4륜 구동 전환 방식을 적용하고 있으며 상대적으로 내구성이 떨어진다. DC motor의 출력이 늘어나고 배터리의 성능이 좋아진 현재 소형 RC car의 최고 속도는 80 km/h 정도로 빨라졌다. 그러나 마찰 계수가 낮은 노면(실내의 대부분 평활 처리된 복도)에서는 2륜 구동 모드의 활용도가 매우 낮다. 미끄러운 노면에서 후륜 구동 모드로는 oversteer가 발생하여 차량이 스핀하기 쉽고 전륜 구동 모드로는 understeer가 발생하여 제대로 된 코너링이 어렵다. 상시 4륜 구동 모드는 에너지 소모가 크고 전후륜이 tight coupling되어 있는 문제 때문에 일반적인 노면에서 부드러운 코너링이 잘 이루어지지 않는 문제가 있다. 본 연구에서 제안하는 방식은 그림 1와 같이 center shaft의 중간에 영구 자석으로 만들어진 토크 전달용 판이 있고 그 사이에 자계를 차폐할 수 있는 강자성체 셔터를 서보 기구에 연결하여 서보 회전각에 따라서 구동 쪽의 토크가 피구동축으로 전달되는 양을 연속 가변제어할 수 있다. 토크 전달용 판의 차폐 면적에 따른 토크 전달양을 전/후륜 바퀴의 Static torque를 통해 측정하였으며(그림 2), 공중 상태에서 즉 공기저항만을 고려한 상태에서의 RPM 회전수 차이 측정(그림3)을 통해 구동 쪽의 회전수가 피구동축으로 전달되는 양을 측정하여 연속가변 토크 제어 전달 기구의 성능을 확인하였다. 이 기구는 현재 1차적으로는 remote controller의 ch 3(ON/OFF제어 방식)에 연결하여 특정한 양의 토크를 전륜 쪽으로 보낼 수 있도록 구현이 가능하며, ch 2(PID제어 방식)에 연결하여 연속 가변 조절이 가능하도록 구현이 가능하다. 부가적으로 Arduino board를 내장하여 전후륜의 휠센서에서 입력되는 신호를 감지하여 자동적으로 전후륜에 배분되는 토크를 제어할 수 있도록 설계 중에 있다.

  • PDF

Degradation of Pesticides in Wastewater Using Plasma Process Coupled with Photocatalyst (광촉매를 병합한 플라즈마 공정을 이용한 폐수에 함유된 살충제 분해)

  • Jang, Doo Il;Kim, Kil-Seong;Hyun, Young Jin
    • Applied Chemistry for Engineering
    • /
    • v.24 no.1
    • /
    • pp.87-92
    • /
    • 2013
  • Nonthermal plasma hybridized with photocatalysts is proven to be an effective tool to degrade toxic organics in wastewater. In this study, a specially designed dielectric barrier discharge (DBD) plasma system combined with photocatalysts was applied to decompose pestiticides such as dichlorovos, carbofuran and methidathon, which are frequently used in the golf courses and the orange plantations. The degradations of the pesticides in single and coupled systems were evaluated. The single system was used with ozone plasma which consisted of electrons, radicals, ions produced by oxygen gas and air, with and without ultra-violet (UV) irradiation, respectively. The coupled systems utilized the air-derived ozone plasma combined with zinc oxide, titanium dioxide and graphite oxide photocatalyst activated by UV. The graphite oxide was synthesized by a modified Hummer's method and characterized using FTIR spectrometer. It was elucidated that the plasma reaction with graphite oxide (0.01 g/L) brought about almost 100% of degradation degrees for dichlorovos and carbofuran in 60 min, as compared with the performances showed by no catalyst condition. The photocatalyst-hybridized plasma in the presence of UV irradiation was proven to be an effective alternative for degrading pesticides.

A Study on Fabrication of Monolithic Lightweight Composite Electronics Housing for Space Application (우주용 일체형 경량 복합재료 전자장비 하우징 제작에 관한 연구)

  • Jang, Tae Seong;Seo, Jung Ki;Rhee, Juhun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.12
    • /
    • pp.975-986
    • /
    • 2013
  • This paper dealt with the fabrication and performance evaluation of the electronics housing made of lightweight composite materials, aiming at the enhancement of satellite mass savings by replacing conventional aluminum alloy widely used for satellite avionics with lightweight composite material. For this purpose, a fabrication process was designed to overcome low machinability of CFRP and to minimize the post-treatment. The composite housing with grid-stiffened and monolithic frame was made using co-curing method. Its performance was also evaluated regarding endurance, stiffness, thermal conductivity, electrical grounding, EMI protection and radiation shielding. The composite housing can provide the considerable mass savings over the aluminum housing with same dimension.

Isolation valve system design account for water quality failure based on graph theory (그래프이론 기반 수질사고 예방형 상수도 관망 밸브 시스템 설계)

  • Park, Kyeongjin;Lee, Seungyub
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.185-185
    • /
    • 2022
  • 상수도 관망의 운영 단계에서 비정상상황의 발생은 필연적으로 발생하며, 비정상상황 발생 시상수도 관망 내 설치된 제수 밸브의 차폐를 통해 해당 구역의 격리 후 복구를 진행한다. 일반적으로 제수밸브를 통해 격리될 수 있는 최소 구역은 세그먼트로 정의하고, 제수밸브 설치 시 세그먼트의 격리로 인한 상수도 관망의 피해를 줄일 수 있도록 위치를 선정한다. 제수 밸브를 통한 격리 시 상수도 관망의 흐름 경로와 유향, 유속의 변화와 같은 수리적 특성 변화가 불가피하다. 지난 '19년도에 발생했던 3건의 수질 사고가 수리적 특성 변화에서 기인했던 것을 고려할 때, 제수밸브 차폐로 상수도 관망의 부분 격리 시 발생 가능한 수리적 특성 변화에서도 수질 사고가 야기될 가능성이 있다. 기존 제수밸브 위치를 결정한 연구들을 보면, 대부분 제수밸브 위치에 따라 결정된 세그먼트의 격리 시 수압 저감을 고려하여, 격리 시에도 상수도 관망의 성능을 최대한 유지할 수 있도록 결정하는 것이 일반적이다. 다만, 앞서 언급한 것과 같이 격리 시 발생 가능한 수리적 특성 변화로, 수압 저감 외에도 예기치 못한 수질 사고의 발생 원인이 되기도 한다. 이에 따라 제수밸브의 최적위치를 결정할 때 수리적 특성 변화를 고려해야 예지치 못한 2차 피해를 줄일 수 있을 것이다. 이에 본 연구는 그래프이론을 활용하여 격리 전후 관로의 유향 변화를 최소화하도록 제수밸브 최적 위치 결정하는 방법론을 제안한다. 그래프이론은 망의 형태를 가지는 상수도 관망의 연결성을 정량화할 수 있으며, 본 연구에서는 수리학적 거리 인자를 적용하여 격리 시에도 각 수요절점이 최소 경로를 확보할 수 있도록 유도하였다. 해당 방법론은 가상 관망에 적용하여 수리학적 거리 인자에 따른 설계와 기존 상수도 관망 성능 극대화 설계 안을 비교하였다. 또한 수질 사고 위험도 인자를 정의하여 해당 인자에 따른 각 설계 안의 효과를 분석하였다. 본 연구는 향후 수질 사고를 고려한 밸브 시스템의 설계 및 운영에 활용할 수 있을 것으로 기대한다.

  • PDF

Evaluation and Verification of the Attenuation Rate of Lead Sheets by Tube Voltage for Reference to Radiation Shielding Facilities (방사선 방어시설 구축 시 활용 가능한 관전압별 납 시트 차폐율 성능평가 및 실측 검증)

  • Ki-Yoon Lee;Kyung-Hwan Jung;Dong-Hee Han;Jang-Oh Kim;Man-Seok Han;Jong-Won Gil;Cheol-Ha Baek
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.489-495
    • /
    • 2023
  • Radiation shielding facilities are constructed in locations where diagnostic radiation generators are installed, with the aim of preventing exposure for patients and radiation workers. The purpose of this study is seek to compare and validate the trend of attenuation thickness of lead, the primary material in these radiation shielding facilities, at different maximum tube voltages by Monte Carlo simulations and measurement. We employed the Monte Carlo N-Particle 6 simulation code. Within this simulation, we set a lead shielding arrangement, where the distance between the source and the lead sheet was set at 100 cm and the field of view was set at 10 × 10 cm2. Additionally, we varied the tube voltages to encompass 80, 100, 120, and 140 kVp. We calculated energy spectra for each respective tube voltage and applied them in the simulations. Lead thicknesses corresponding to attenuation rates of 50, 70, 90, and 95% were determined for tube voltages of 80, 100, 120, and 140 kVp. For 80 kVp, the calculated thicknesses for these attenuation rates were 0.03, 0.08, 0.21, and 0.33 mm, respectively. For 100 kVp, the values were 0.05, 0.12, 0.30, and 0.50 mm. Similarly, for 120 kVp, they were 0.06, 0.14, 0.38, and 0.56 mm. Lastly, at 140 kVp, the corresponding thicknesses were 0.08, 0.16, 0.42, and 0.61 mm. Measurements were conducted to validate the calculated lead thicknesses. The radiation generator employed was the GE Healthcare Discovery XR 656, and the dosimeter used was the IBA MagicMax. The experimental results showed that at 80 kVp, the attenuation rates for different thicknesses were 43.56, 70.33, 89.85, and 93.05%, respectively. Similarly, at 100 kVp, the rates were 52.49, 72.26, 86.31, and 92.17%. For 120 kVp, the attenuation rates were 48.26, 71.18, 87.30, and 91.56%. Lastly, at 140 kVp, they were measured 50.45, 68.75, 89.95, and 91.65%. Upon comparing the simulation and experimental results, it was confirmed that the differences between the two values were within an average of approximately 3%. These research findings serve to validate the reliability of Monte Carlo simulations and could be employed as fundamental data for future radiation shielding facility construction.