• 제목/요약/키워드: 차음 성능

검색결과 248건 처리시간 0.03초

항공기소음에 노출된 학교 교실 창호 설계에 관한 연구 (A Study on the Window Design of School Class Room Exposed to The Aircraft Noise)

  • 송혁;송민정;박현구;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.710-717
    • /
    • 2003
  • This study aim to find an appropriate window for class rooms to provide proper sound insulation against aircraft noise and to achieve this, measurements were taken of the sound insulation performance of windows with varying thicknesses of inner air space and sound absorption materials in the inner air spaces. As a result of (his study the improvement of the sound insulation performance of windows(single , double and triple window) has been shown through the analysis and the measuring of windows with these characteristics. These results may be applied to the manufacture of window frames and provide data lot the improvement of the sound insulation performance of windows.

  • PDF

차음성능시험에서 시편설치위치에 대한 실험적 고찰 (Investigation for effect of the specimen location on sound transmission loss measurement)

  • 김상렬;강현주;김재승;김현실;김봉기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.1234-1237
    • /
    • 2002
  • When measuring sound transmission loss (STL) in a laboratory, the specimen location in test aperture affects considerably the measuring accuracy through the influence of so-called “tunneling effect” In this paper, for a single panel and a double panel with air cavity, experimental STL evaluations on various specimen locations on test aperture were carried out to explain the phenomenon. It is shown that the difference of STL is more than 2dB especially at the low frequency region and the case of the center-located panel yielded the lower STL than that of flushing with the end of tunnel, which confirms that the tunneling effect plays an important role in STL measurement.

  • PDF

공항 인근 건물(호텔)에서의 벽체구조의 차음성능에 관한 연구 (An experimental study on sound insulation of building elements of the hotel near airport)

  • 이성호;정갑철;양관섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.579-585
    • /
    • 2002
  • This study has measured and evaluated the sound insulation of building elements of the hotel near airport. That measurement was made in both the actual site and laboratory. The differences of sound insulation performance in between granite and double glass were measured. Moreover, the difference of sound insulation was analyzed. For the measurement, this study has tried several methodologies, and analyzed the differences respectively. The results from this analysis were applied to produce a design guides for sound insulation to prevent external noise and to make more silent indoor space which satisfied the standard rate of noise.

  • PDF

차음성능 계측시 터널링 효과에 관한 해석적 연구 (Tunneling Effect on Sound Transmission Loss Measurement)

  • 김봉기;김재승;김현실;강현주;김상렬
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.1228-1233
    • /
    • 2002
  • This study is aimed to evaluate a tunneling effect in association with the measurement of sound transmission loss. Based on the formulation for sound transmission loss of a finite panel in the presence of tunnel, variations of the sound transmission loss with parameters such as the location of panel and tunnel depth are investigated. It can be seen that differences in the sound transmission loss are quite evident below coincidence frequency and the sound transmission loss greatly depends on panel location in the tunnel. In comparison with the case without a tunnel, maximum difference occurs in the case where the panel is placed on the center of the tunnel and the flushing with the end of the tunnel gives the better estimation of transmission loss.

  • PDF

소형 창문의 차음 성능 평가에 관한 실험적 고찰 (An experimental study for the evaluation of airborne sound insulation performance of the small window)

  • 최둘;문순성;구희모;김항;박현구
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.1-1
    • /
    • 2014
  • Side scuttle in the shipboard windows is used in a smaller size in order to prevent damage to the glass. This shipboard windows should have high sound insulation performance (More than $R_w$ 53 dB) according to norsok standards. However, side scuttle having a small size and high sound insulation material is difficult to measure exact result without a suitable filler wall. In this study, the test was conducted according to the number of changes in the small window. As a result, before starting the test should be conducted to the selection of the suitable filler wall or secure a specimen area.

  • PDF

축소잔향실의 저주파수 차음성능평가에 관한 고찰 (Study on evaluation of sound insulation performance of low frequency in a scaled reverberation chamber)

  • 강현주;김봉기;오영근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1376-1378
    • /
    • 2006
  • Numerical and experimental study were carried out to characterize sound fields of low frequency in a scaled reverberation chamber for measurement of sound insulation of panels. By using BEM, lower modes of the chamber are identified and then predicted the effect of diffusers in order to destruct lower modes. Compared results with measurements show reasonable agreements, especially at the first end second modes. Based on numerical prediction, the diffuser are installed in order to improve sound fields to be more diffuse than ever. It is found that the diffuser put in nodal line of the chamber destruct evidently the first mode. Consequently, the measuring error at the low frequency can be relatively reduced compare to the case of without diffuser.

  • PDF

Bottom ash를 이용한 경량판넬의 특성 연구 (A Study on the acoustic characteristic of the Light weight Concrete Panel using bottom ash)

  • 이성호;정갑철;정진연
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1379-1382
    • /
    • 2006
  • Recently, the method of the apartment building design has been changed from wall type structures to moment structures. With like this reason dry walls are used plentifully. Especially, the gypsum board was used from previously plentifully however the weak point of it is difficult to maintain because it weak strength. For the improvement of gypsum board, light weight concrete panel using cement board is used recently. As this study is the research of the series t on the development of non-hearing light weight concrete Panel using bottom ash, the Purpose of this study is to obtain basic data for application in the field. The results are that the structure 1 satisfies domestic standard concerned with sound insulation between households at the laboratory and field test.

  • PDF

벽체 우회전달음 영향요소에 관한 연구 (A Study on the Factor of Flanking Noise in the Wall)

  • 정진연;정갑철
    • 한국소음진동공학회논문집
    • /
    • 제17권2호
    • /
    • pp.143-148
    • /
    • 2007
  • This study examines the influence factor of flanking noise in the wall. Generally, there is the difference of airborne sound isolation between laboratory and field test. The purpose of this study is examing the cause of droping sound insulation performance in the field and searching the method of improving sound insulation performance. First, we measured the sound isolation in the wall at the lab. Then, we measured it in the field and compared them. At the base of these datum, we measured the flanking noise and solid transmission. For the flanking noise in the wall, we used intensive method. So, we found the influence of solid transmission.

저회를 이용한 경량판넬의 특성 연구 (A Study on the Acoustic Characteristic of the Light Weight Concrete Panel Using Bottom Ash)

  • 정갑철;정진연
    • 한국소음진동공학회논문집
    • /
    • 제17권2호
    • /
    • pp.149-154
    • /
    • 2007
  • Recently, the method of the apartment building design is changing from wall type to moment structure. Dry walls are used plentifully. Until now, the gypsum board is used mainly but it has many problems. For improving the problems, the light weight concrete panel using cement board is used recently. The purpose of this study is to obtain basic data for the light weight concrete panel using bottom ash. As a result, some structures satisfies domestic standard concerned with sound insulation between households at the laboratory and field test.

틸팅열차용 화이버 다층재의 차음성능 해석 (Transmission Loss Analysis of the Fiber Sandwich Panels for a Tilting Train)

  • 김석현;백인수;김재철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.2191-2194
    • /
    • 2008
  • This paper investigates the sound insulation performance of the fiber sandwich panels for a tilting train. Due to the high strength and low mass, fiber sandwich panels are widely used for aircraft structures, railway vehicle structures. These fiber sandwich panels show orthotropic behavior because of the fiber's structural characteristics. This orthotropy often reduces the critical frequency and makes negative effect on the sound insulation performance. In this study, transmission loss of the fiber panels is analyzed based on the equivalent orthotropic plate model. An analysis program is developed to calculate the transmission loss of the fiber sandwich panels. Using the program, the coincidence frequency ranges and their effects on the transmission loss are investigated.

  • PDF