• Title/Summary/Keyword: 질량분석기

Search Result 654, Processing Time 0.03 seconds

A Study on the Applicability of Hybrid Mass Damper for the Vibration Control of the Structure under Base Excitation (지반 기진력을 받는 구조물의 진도제어를 위한 Hybrid Mass Damper의 유용성에 관한 연구)

  • 문석준;임채욱;정태영;한성용
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.4
    • /
    • pp.1-8
    • /
    • 2001
  • In this paper, a hybrid mass damper using AC-servomotor was designed and developed in order to reduce vibration levels of a 5-story test structure under base excitation. Control performances of the HMD under random and earthquakes excitations are compared with those of TMD through experimental test. It is confirmed that the HMD is more effective to reduce the vibration levels of the test structure especially for the earthquake excitation which excites more than 2 vibration modes of the structure simultaneously.

  • PDF

Analysis of Chemical Accident-Causing Substances Using a Proton Transfer Reaction-Time of Flight Mass Spectrometer (양자전이 비행시간 질량분석기를 이용한 화학사고 원인물질 분석)

  • Kim, So-Young
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.80-86
    • /
    • 2019
  • In Korea, a total of 556 chemical accidents occurred from 2012 to 2018 caused by adverse reactions of two or more chemicals, which required significant amounts of time to identify the causative chemicals. Rapid analysis is required for effective incident response and probing. In this study, a quantum transition time-of-flight mass spectrometer was used to identify the causative agents of chemical accidents caused by adverse reactions. The analyzer enabled fast real-time analysis without the need for sample collection and pretreatment. Quantitative and qualitative analysis of most volatile organic compounds with high hydrogen affinity was performed to investigate the cause of the chemical accidents. In fact, in the month of 201◯, methanol and toluene were detected as causative agents of the accident using a quantum transition time mass spectrometer, and were also the cause of the reported odor.

Scientific Achievements and Technology Trends of Mass Spectrometers for Space Exploration (우주탐사용 질량분석기들의 과학적 성과와 기술 동향)

  • Ik-Seon Hong;Yu Yi;Jingeun Rhee;Nam-Seok Lee;Sung Won Kang;Seontae Kim;Kyu-Ha Jang;Cheong Rim Choi;Kyoung Wook Min;Jongil Jung
    • Journal of Space Technology and Applications
    • /
    • v.3 no.1
    • /
    • pp.26-43
    • /
    • 2023
  • As Korean first lunar probe, Danuri, succeeded in entering lunar orbit, Korean new space exploration plans such as Mars exploration can be expected. Korean space exploration payload is developed only in a limited field, so there is a need to create a new space exploration payload. In foreign countries, there is a mass spectrometer as a basic equipment for space exploration, and it is a very useful payload that encompasses the exploration of life through the analysis of organic matter as well as the observation of the atmosphere and volatile substances of the exploration target. However, Korea has never developed a mass spectrometer payload for space exploration, so it is necessary to secure technology in preparation for future space exploration. Before that, we look at the scientific achievements of foreign mass spectrometer payloads for space exploration and identify trends.

Pulsed-Delayed Extraction for Resolution Enhancement of Linear Time-of-Flight Mass Spectromenter in Surface-Assisted Laser Desorption/Ionization of Polypropyleneglycol (폴리프로필렌 글리콜의 표면-보조 레이저 탈착/이온화에서 선형 비행시간 질량분석기의 분해능 개선을 위한 시간 지연 추출법의 응용)

  • Kim, Jung Hwan;Kang, Wee Kyung
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.4
    • /
    • pp.328-336
    • /
    • 2000
  • The pulsed-delayed extraction (PDE) in linear time-of-flight mass spectrometer(TOF MS) is characterized on the enhancement of resolution, mass-depth of focus and effect of instrumentahan 2000. The ion signals separate isotopically by up to molecular weight of 2500 in instrumental broadening of 5 ns, which is a good agreement with calculation. The fragmentation paths of PPG can be sug-gested by the isotopica distributions of fragment series produced when PPG desorbed from graphite surface.

  • PDF

Feasibility study of membrane interface for gas chromatograph-mass spectrometry (기체크로마토그래프-질량분석기의 실리콘 분리막 인터페이스의 유용성 연구)

  • Kang, Gil Seon;Lee, Dong Soo;Lee, Hwa Sim;Park, Chang Joon
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.495-501
    • /
    • 2008
  • Agilent 5973 GC-MS instrument was modified so that the capillary direct interface was removed and that a silicone membrane was installed between GC and MS. Feasibility study of the membrane interface GC-MS has been carried out. Vacuum of the mass spectrometer was not affected by the carrier gas flow rate up to $4.7m{\ell}/min$. As the carrier flow rate was increased, peak tailing was reduced and chromatogram peaks appeared earlier. Chromatogram peaks showed better separation and higher sensitivity as the membrane thickness was reduced from $127{\mu}m$ to $75{\mu}m$, and also as the interface temperature was increased. However, the membrane interface GC-MS had drawbacks such as background ions at 73 and 147 m/z and poor peak separation due to peak tailing.

동위원소희석법과 열이온화 질량분석기에 의한 화강암질 대수층내 지하수의 희토류원소 분포도 및 그 의의

  • 이승구;김건한;김용제;성낙훈;아키마사마스다
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.59-62
    • /
    • 2003
  • 동위원소희석법에 의한 열이온화 질량분석법 (ID-TIMS)을 이용하여 지하수내 희토류원소의 함량을 측정하였다. 희토류원소의 분리에는 철공침법과 양이온교환수지에 의한 컬름분리법을 이용하였다. 경희토류(La-Eu)와 Gd, Dy, Er의 경우 수-수십 ppt의 수준에서 1%이내의 오차범위를 측정되어졌으며, 중희토류 중 Yb와 Lu은 정확도가 다소 떨어진 10% 전후에서 측정되었다. 지하수내 함량을 운석으로 규격화한 결과, 경희토류가 부화되었고 중희토류는 결핍되었으며 Eu의 이상은 거의 존재하지 않는다. 특히 경희토류에서는 M-type의 테트라드효과, 중희토류에서는 W-type의 테트라드효과가 관찰되었다. 이는 희토류원소의 수화수와 밀접한 관련이 있는 것으로 사료된다.

  • PDF

Measurement of Oxygen Isotope Ratio in Water Vapor by using Tunable Diode Laser Absorption Spectroscopy(TDLAS) - II (다이오드레이저 흡수분광법을 이용한 수증기의 산소 동위원소 성분비 측정 - II)

  • Jung, Do-Young;Park, Sang-Eon;Kim, Jae-Woo;Ko, Kwang-Hoon;Im, Kwon;Jung, Eui-Chang;Kim, Chul-Joong
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.202-203
    • /
    • 2003
  • 여러 가지 원소의 동위원소 성분 분석은 생물학, 화학, 환경학, 연대학, 기후학 연구에 있어서 중요한 정보를 제공하는 유용한 수단이다. 동위원소 성분비를 측정하는 방법으로는 가스 동위원소 질량분석기를 이용한 방법이 사용되어 왔지만, 최근 다이오드 레이저의 발달과 함께 다이오드레이저 흡수분광법(TDLAS)이 개발되어 사용되고 있다. TDLAS 방법의 경우 질량분석기를 이용하는 방법에서는 측정이 불가능한 동일질량 분자의 동위원소 성분비를 측정할 수 있다. (중략)

  • PDF

Development of Ambient Ionization Mass Spectrometry Imaging for Live Cells and Tissues

  • Kim, Jae-Yeong;Seo, Eun-Seok;Lee, Seon-Yeong;Jeong, Gang-Won;Mun, Dae-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.229.1-229.1
    • /
    • 2015
  • 생체 시료인 세포나 조직을 분석을 위해 임의로 파괴하거나 훼손하지 않은 본래의 상태에서 세포에 존재하는 다양한 생체분자 물질의 질량과 조성을 분석하고 영상화할 수 있는 대기압 표면 질량분석 이미징 기술을 개발했다. 생체 시료의 표면을 질량 분석을 하기 위해서는 대기압 분위기에서 시료에 열적 손상이 없는 조건으로 시편의 이온화 및 탈착 과정이 이루어지게 하기 위해 저온 대기압 탈착/이온화원으로 저온대기압 플라즈마 젯과 펨토초 적외선 레이저를 결합하여 대기압 이온화원을 제작하였다. 기존에 잘 알려진 저온 대기압 플라즈마 젯 소자는 유리관에 방전기체를 흘려주고 전극에 고전압을 인가하는 방식으로 제작했으며, 또 다른 대기압 이온화원으로서 근적외선 대역의 고출력 펨토초 레이저 빔을 현미경용 대물렌즈로 집속하여 생체시료에 조사시켰다. 수백 나노미터에서 수 마이크로미터 수준으로 빔을 집속할 수 있는 펨토초 레이저는 금나노로드의 도움으로 생체 시료를 매우 작은 수준으로 탈착하는 데 주로 사용하며, 수십 마이크로미터에서 수 밀리미터 정도의 크기를 가지는 저온 대기압 플라즈마 젯은 탈착된 물질을 이온화시키는데 사용하여, 이 두 가지 이온화원을 결합하여 이온화원으로 사용한다. 시료에서 발생한 이온을 질량분석기 입구까지 잘 끌고 갈 수 있도록 이온 전달관을 설계하고 보조펌프를 장착 사용한다. 이렇게 자체 개발한 대기압 이온화원을 상용 질량분석기기와 결합하여 대기압 분위기에서 시료의 표면을 질량분석할 수 있는 시스템과 측정 기술을 개발했다. 현미경 스테이지에 정밀 2-D 자동 스캐닝 스테이지를 장착하여 질량분석 정보에 공간 정보를 더할 수 있는 질량분석 이미징 기술 방법을 개발하여 생체 시편의 질량분석 이미징을 얻었다. 수분을 포함하는 생채시료로부터 단백질, 지질, 대사물질을 직접 분리하여 분석하는 이 새로운 질량분석법은 기존의 분석법에 비해 훨씬 더 많은 생체분자 정보를 얻을 수 있으며 공간정보를 더해 영상화할 수 있는 큰 장점이 있다. 대기압 표면 질량분석 기술은 생체시료를 파괴해서 용액화할 필요도 없으며, 진공 챔버에 넣기 위해 필요한 복잡한 전처리 과정 단계를 간략화 할 수 있으며 최종적으로는 살아있는 세포나 생체 조직도 정량 분석이 가능하여 생명과학 및 의료진단 분야에서 응용할 수 있는 분야는 무궁무진할 것이다.

  • PDF