• Title/Summary/Keyword: 진폭스펙트럼

Search Result 162, Processing Time 0.032 seconds

A Study on Maximum Responses of Rotational Shells Subjected to Uneven Settlements by Stochastic Method (부등침하를 받는 회전 쉘의 최대응답 추정에 관한 연구)

  • 정명채
    • Computational Structural Engineering
    • /
    • v.10 no.3
    • /
    • pp.175-184
    • /
    • 1997
  • The objective of this paper is to study arelationship between maximum response and its standard deviation of rotational shells that are subjected to uneven settlements. For this, the ratio, .eta, of the maximum response to standard deviation and it's approximate, .eta./sub apr/, are investigated by stochastic methods. Also, an equation for .eta./sub apr/, that is a function of predominant harmonic number is suggested. The settlements are represented by the Fourier series. Each term in the series contains two coefficients; the amplitude and the phase angle. It is assumed that phase angles are random variables and amplitudes are deterministic. To investigate the characteristics of .eta. and .eta./sub apr/, 100 phase angles for two types of artificial amplitudes spectra are used in the analysis. .eta. and .eta./sub apr/, are almost constant regardless of amplitude type, position of a shell or type of responses; they fall into from 2.0 to 2.5. .eta./sub apr/ is always close to .eta., but tends to be somewhat greater. It may be concluded that a maximum responses of rotational shells subjected to uneven settlements are .eta./sub apr/ (about 2.5) times of its standard deviation. It is considered that this result is used when we design rotational shell structures subjected to differential settlements.

  • PDF

A Study on the Ultrasonic Measurement for Damage Evaluation of Power Plant Bearing (발전용 베어링 손상평가를 위한 초음파 측정 연구)

  • Lee, Sang-Guk
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1727-1732
    • /
    • 2004
  • For the purpose of monitoring by ultrasonic test of the ball bearing conditions in rotating machinery, a system for their diagnosis was developed. ultrasonic technique is used to detect abnormal conditions in the bearing system. And various data such as frequency spectrum, energy and amplitude of ultrasonic signals, and ultrasonic parameters were acquired during experiments with the simulated ball bearing system. Based on the above results and practical application for power plant, algorithms and judgement criteria for diagnosis system was established.

  • PDF

On a pitch detection with spectrum compensation technique of speech signal (스펙트럼 보상에 의한 피치 검출에 관한 연구)

  • Ahn, Jung-Hyun;Bae, Myung-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.401-402
    • /
    • 2006
  • 음성인식, 합성 및 분석과 같은 음성신호처리 분야에 있어서 기본주파수 즉, 피치를 정확히 검출하는 것은 중요하다. 그러나 포만트의 영향과 천이진폭의 영향 때문에 음성신호에서 피치를 정확히 구하는 것은 매우 어렵다. 더구나 노이즈가 포함된 신호에서는 더 더욱 어려워진다. 따라서 본 논문에서는 켑스트럼영역에서 포만트의 영향 을 제거하고 밴드 필터링 한 후 기본 피치 정보를 강조 보상하여 피치주기를 검출하는 방법을 새로이 제안한다.

  • PDF

The Performance Analysis of the Parameter Extracting Technique for the Vibration Monitoring System in High Voltage Motor (고압전동기용 진동 감시 시스템의 계수 추출기법 성능 분석)

  • Park, Jung-Cheul;Lee, Dal-Ho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.5
    • /
    • pp.529-536
    • /
    • 2019
  • In this paper, the signals of the sensor for extracting characteristic parameters of the rotor are collected and the performance of the extraction technique is analyzed. To this end, a vibration test league was developed for conducting model tests to analyze the signal characteristics under normal operation. As a result, it is judged that no change in the measured the raw data amplitude will occur in the acceleration sensor with the unbalanced mass measured from the acceleration sensor. Performing FFT showed a significant increase in amplitude of the rotational frequency of 20 Hz as the unbalanced mass increased. The analysis results according to the change in the unequal mass of the speed sensor also showed a significant increase in the 1X Harmonics component, such as the acceleration sensor. There was no change in the amplitude of the acceleration sensor data when the misalignment occurred, and for the Envelope data, the amplitude of 2X (40 Hz) was increased depending on the degree of misalignment. The velocity sensor at change of misalignment also showed similar results to the acceleration sensor, and the peak was reduced at 600 Hz as the load increased in the frequency spectrum.

Analysis of Low-frequency Reverberation Inshallow Water (천해에서의 저주파 잔향음 분석)

  • 박길선;나정열;최지웅;오선택;박정수
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.94-100
    • /
    • 2001
  • In October 1997, low-frequency reverberation was measured at an experimental site off the west coast of the Jeju island using the explosive charge, Signals Underwater Sound (SUS). Received signals were separated into the noise, the reflection, and the scattering region, and then were analyzed for the spectral and statistical characteristics of each region. In the analysis of the spectrum we verified that each region had a unique frequency band and statistical characteristics as well. The results of this analysis showed that the real and imaginary portions were shown to be both normal distributions in each frequency bin. The reverberation envelope had a Rayleigh distribution and the phase had a uniform distribution.

  • PDF

A Study on the Technique of Spectrum Flattening for Improved Pitch Detection (개선된 피치검출을 위한 스펙트럼 평탄화 기법에 관한 연구)

  • 강은영;배명진;민소연
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.3
    • /
    • pp.310-314
    • /
    • 2002
  • The exact pitch (fundamental frequency) extraction is important in speech signal processing like speech recognition, speech analysis and synthesis. However the exact pitch extraction from speech signal is very difficult due to the effect of formant and transitional amplitude. So in this paper, the pitch is detected after the elimination of formant ingredients by flattening the spectrum in frequency region. The effect of the transition and change of phoneme is low in frequency region. In this paper we proposed the new flattening method of log spectrum and the performance was compared with LPC method and Cepstrum method. The results show the proposed method is better than conventional method.

Characterization of Supercontinuum Generation as a function of Pump Wavelength and Intensity in Photonic Crystal Fiber (광자 결정 광섬유에서 펌프광원의 파장과 입력파워에 따른 초 광대역 광원 발생의 특성)

  • Kim, Jong-Doo;Yee, Ki-Ju;Jeon, Min-Yong;Ahn, Seong-Joon;Choi, Yong-Gyu
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.6
    • /
    • pp.490-493
    • /
    • 2005
  • We have experimentally studied supercontinuum generation in a photonic crystal fiber as a function of pump wavelength and intensity with 100 fs pulsewidth. A supercontinuum over 750 nm spectral width with amplitude variation less than 10 dB has been achieved. It was generated by coupling femtosecond pulses from a mode-locked Ti:Sapphire laser into a 2 m long photonic crystal fiber. Adjusting the parameters of the pump source, it was also possible to control different spectral features of the supercontinuum radiation.

Comparison with 1.5Tesla and 3.0Tesla of Acoustic Noise Spectrum of DWI MR Pulse Sequence (1.5Tesla and 3.0Tesla에서 관류 MR의 소리 스펙트럼 분석)

  • Kweon, Dae Cheol;Choi, Jiwon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.491-496
    • /
    • 2018
  • The purpose of this study is to analyze the noise spectra in DWI (diffusion-weighted imaging) pulse sequences of 1.5 Tesla and 3.0 Tesla MRI, The ACR (American College of Radiology) phantom and noise spectrum were analyzed by FFT (fast Fourier transform) and TFFT (temporal frequency analysis) using WavePad sound editor version 8.13 (NCH software, Greenwood Village, CO, USA). Noise spectra, FFT and TFFT were analyzed for laboratory 1.5Tesla and 3.0Tesla DWI MR pulse sequences. The noise threshold of the frequency amplitude in the FFT and TFFT at 3.0Tesla compared to 1.5Tesla was between 1.5Tesla and -6 dB, and between 3.0Tesla and 0 dB, the DWI pulse sequence for the patient's noise reduction was appropriately MR examination needs to be applied.

Design and Performance Analysis of CPSK Transmitter for RF-CBTC System in ISM Band (RF-CBTC 시스템을 위한 ISM 대역에서의 CPSK 송신기의 설계 및 성능분석)

  • Kim, Seong-Cheol
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.16 no.5
    • /
    • pp.152-161
    • /
    • 2017
  • The CBTC(Communication based Train Control) system employed on 2.4GHz ISM band adopt the IEEE802.11.x standard. Therefor communication time delay, distortion and data losses will be produced. To overcome these problems, CPSK(Continuous Phase shift keying) modulated DS/SS(Direct Sequence Spread Spectrum) transmitter with 908MHz carrier frequency is proposed. Through the eye diagram and scatter diagram the performance is analysed. And the phase noise characteristic of the local oscillator is measured about 60dBc/Hz, this means that the phase noise performance is very good compared to the signal. Reference frequency suppression of the 2nd local oscillator is 50dB below compared to the signal. Through the polarities of the complementary signal equally probable, the line spectrum of the output spectrum is eliminated. The nonlinear effects which introduce the spectral spreading or spectral regeneration is reduced remarkably.

A Study of the Construction in order to 24/25 I-NRZI Modulator Designs for DVCR (DVCR용 24/25 I-NRZI 변조기의 설계를 위한 구조 고찰)

  • Park, Jong-Jin;Kook, Il-Ho;Kim, Eun-Won;Cho, Won-Kyung
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.37 no.1
    • /
    • pp.35-41
    • /
    • 2000
  • This paper considers the consturction of 24/25 I-NRZI (Interleaved - Non Return to Zero Inverse) modulator designs for DVCR (Digital Video Cassette Recorder), and size of validity bit in order to store the amplitude value of square-wave and the standard data ( sine and cosine coefficients) at ROM Table that to acceptable the spectrum standard. The validity bit size of the standard data and the amplitude value of square-wave that to store at ROM Table are affected the size of pilot signal on the output spectrum, and the hardware size of modulator. At the designable 24/25 I-NRZI modulator, we simulated using random pattern (F0,F1,F2) that to verification the output data of the spectrum. Moreover, the resultant of the spectrum analysis, at the optimizing value, is 0.065 on the amplitude value of square-wave, and 3bit on the size of bit in order to store the standared data at ROM Table. In order to verify the hardware of designable 24/25 I-NRZI modulator, we perform to modeling of C-language firstly, and coding to Verilog HDL (Cadence Verilog XL) and synthesized using Synopsys (Library "Samsung KG75") tool as a base of spectrum results. In a foundation of this result, we are considered the size of hardware. In this paper, a considerable 24/25 I-NRZI modulator designable less than 10,000 gates as that is improved consturction as regards the path method of pre-coder etc, and able to application digital camcorders as now practical use.

  • PDF