• Title/Summary/Keyword: 진동허용값

Search Result 34, Processing Time 0.025 seconds

Seismic Evaluation for Strainer in the Primary Cooling System (일차 냉각계통 스트레이너에 대한 내진 건전성 평가)

  • 정철섭
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.3
    • /
    • pp.295-304
    • /
    • 2000
  • To evaluate the structural integrity for the strainer under seismic loading the seismic analysis and design were performed for T-type strainer in accordance with ASME, Section Ⅲ, Class 3(ND). Since there are no specified design requirements for the strainer in ASME Code, the strainer body was analysed according to ND-3500, valve design. Flanged joints connected with PCS piping were designed according to ND-3658.3. And the criteria for the cover flange was governed by the Appendix XI. Both a frequency analysis and an equivalent static seismic analysis of the strainer were carried out using the finite element computer program, ANSYS. The frequency analysis results show the fundamental natural frequency is greater than 33Hz, thus justifying the use of the equivalent static analysis through which membrane and bending stresses are obtained in the critical points near the branch connection area. The results of the seismic evaluation fully satisfied with the structural acceptance criteria of the ASME Code. Accordingly the structural integrity on the strainer body and flanges were proved.

  • PDF

A Slim PZT Actuator for Small form Factor Optical Disk Drives (초소형 광디스크 드라이브용 압전형 액츄에이터 제작)

  • Woosung Yang;Lee, Seung-Yop;Park, Young-Phil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.762-769
    • /
    • 2003
  • 본 연구에서는 적층형 압전소자를 이용하여 초소형 및 슬림형 광디스크 드라이브용 광픽업 구동기를 개발하였다. 최근에 휴대용 정보기기의 급격한 발달로 인해 다양한 형태의 초소형 정보저장기기가 사용되고 있으며 착탈식 형태의 초소형 광디스크를 사용하는 ODD가 개발 중에 있다. 적층 형태의 압전소자와 유연 힌지 형태의 변위 확대기구를 사용하여 구동기의 출력 힘과 허용 변위를 증가시키도록 설계하였다. 압전형 구동기의 동특성을 고려한 모델링과 이론적 해석을 통해 목표 변위와 성능을 만족하도록 설계 변수를 최적화하였고 이를 ANSYS를 이용한 해석과 비교하였다. 상용화된 적층형 압전소자를 이용한 prototype 올 제작하여 실험을 수행하였으며 이론적인 예상 값과 잘 일치함을 보였다. 이와 같은 이론적 해석과 실험 결과를 토대로 높이가 2.5mm이며 15V 에서 $\pm$400$\mu\textrm{m}$의 변위를 갖는 슬림형 및 초소형 ODD에 적합한 압전형 구동기를 설계하였다.

  • PDF

A Vibration Evaluation and Improvement Scheme for Open Test Blasting (노천시험발파의 진동평가와 개선방안)

  • Kim, Eung-Rok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.310-315
    • /
    • 2017
  • Although studies evaluating the effects of the blasting vibration on the adjacent structures from various angles have continued, cases of securing the safety of the adjacent buildings and researching the proper blasting method for the field condition by analyzing the vibration waveform of the measuring field while performing the open pit blasting are poor. Therefore, it is necessary to present a remedy for blasting pattern selection through test blasting that is appropriate for field conditions, and is economical and efficient. In this study, open pit blasting work was conducted based on the separation distance applied according to the standard blasting method by test blasting and the vibration regulation standard in the road expansion construction site to measure the blasting vibration value, and the vibration prediction equation by blasting methods was examined using a regression analysis computer program to calculate K, N, and R of the confidence level 95%. By setting the blasting allowed vibration standard of the test blasting target area to 0.3cm/sec, and the charring weight and blasting method by the separation distances according to the blasting vibration estimation equation of the open pit blasting guideline and the blasting vibration estimation equation of the test blasting were compared/analyzed, it was possible to identify the factors that increased the working expenses. In addition, the measurement and analysis of the adjacent structures during open pit blasting and the blasting vibration were performed after selecting the most adjacent structure to the open pit blasting spot to analyze the problems on the test blasting procedure and analysis method in the open pit blasting design/construction guidelines, which appeared in the process of completing open pit blasting construction, and a remedy is presented.

Output-Only System Identification and Model Updating for Performance Evaluation of Tall Buildings (초고층건물의 성능평가를 위한 응답의존 시스템판별 및 모델향상)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.19-33
    • /
    • 2008
  • Dynamic response measurements from natural excitation were carried out for 25- and 42-story buildings to evaluate their inherent properties, such as natural frequencies, mode shapes and damping ratios. Both are reinforced concrete buildings adopting a core wall, or with shear walls as the major lateral force resisting system, but frames are added in the plan or elevation. In particular, shear walls in a 25-story building are converted to frames from the 4th floor level downwards while maintaining a core wall throughout, resulting in a fairly complex structure. Due to this, along with similar stiffness characteristics in the principal directions, significantly coupled and closely spaced modes of motion are expected in this building, making identification rather difficult. By using various state-of-the-art system identification methods, the modal parameters are extracted, and the results are then compared. Three frequency-domain and four time-domain based operational modal identification methods are considered. Overall, all natural frequencies and damping ratios estimated from the different identification methods showed a greater consistency for both buildings, while mode shapes exhibited some degree of discrepancy, varying from method to method. On the other hand, in comparison with analysis results obtained using the initial finite element(FE) models, test results exhibited a significant difference of about doubled frequencies, at least for the three lower modes in both buildings. To improve the correlation between test and analysis, a few manual schemes of FE model updating based on plausible reasons have been applied, and acceptable results are obtained. The advantages and disadvantages of each identification method used are addressed, and some difficulties that might arise from the updating of FE models, including automatic procedures, for such large structures are carefully discussed.

Evaluation of Wake Galloping for Inclined Parallel Cables by Two-Dimensional Wind Testes Tests (2차원 풍동실험을 통한 평행 경사 실린더의 웨이크 갤로핑 평가)

  • Kim, Sun-Joong;Kim, Ho-Kyung;Lee, Sang-Hoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.6
    • /
    • pp.763-775
    • /
    • 2011
  • The wake galloping phenomenon is evaluated for two cylinders via two-dimensional wind tunnel tests. The two cylinders are deployed parallel to the inclination of the vertical plane, which simulates the inclined stay cables of a cable-stayed bridge. The upstream and downstream displacements of the cylinder are observed with varying center distances between the two cylinders. The effect of structural damping on the mitigation of wake galloping is also investigated. The amplitude of the vibration is very sensitive to center distance between the two cylinders. The maximum amplitudes exceededthe allowable limit of the design guidelines for small center distances of less than or equal to six times the diameter of the cylinder. The overall results conformedto the conventional design practice for the wake galloping of parallel cables. It was found, however, that the increase in the damping was not effective in reducing the amplitude of the vibration in the wake galloping phenomenon.

Paralytic Shellfish Poison of Bivalves in the Korean Waters (한국산(韓國産) 주요(主要) 이매패류(二枚貝類)의 마비성패독(痲痺性貝毒) 독화상황(毒化狀況))

  • Jeon, Joong-Kyun;Yi, Soon Kil;Huh, Hyung Tack
    • 한국해양학회지
    • /
    • v.23 no.3
    • /
    • pp.123-129
    • /
    • 1988
  • The toxicity of bivalves in the Korean waters was investigated during 1987-1988. The toxicity of paralytic shellfish poison (PSP) was found in the sea mussels (Mytilus edulis galloprovincialis, M. corsucus), scallops (Patinopecten yessoensis, Chlamys farreri), tellin (Peronidia venulosa) and venus clam (Ruditapes philippinarum) among the 28 species screened. The toxicity in mussels, scallop (C. farreri) and venus clam was mainly confirmed from the samples collected around Jindong Bay in the southern coast of the peninsula, whereas the toxicities of tellin and scallop (P. yessoensis) were found in the vicinity of Pohang in the east coast. Samples from the west coast showed low levels of toxicity than those from the east arid south coasts. Although it varied with the regions, the toxicity was detected mainly during April to June, exceptionally during May to August in Pohang. The levels of toxicity were generally below the criteria of 4 mouse unit (MU)/g edible portion in foreign countries, with few exceptions.

  • PDF

Field Application Analysis of Cable Tension Measuring Device on Cable-Stayed Bridges (사장교 케이블장력 계측장치의 현장적용성 분석)

  • Lee, Hyun-Chol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.295-311
    • /
    • 2021
  • In this study, an experiment was carried out on the field applicability of tension measuring devices of the cables in cable-stayed bridges. The vibration method was used to estimate the tension of cables of cable-stayed bridge, and the mode characteristics of the cable were analyzed using a cable tension measuring device. GTDL360, NI Module, and 9 Axes Motion Sensorwere applied to estimate the cable tension of five target bridges. Numerical analysis of the five target bridges was conducted to analyze the natural frequency of the cable and cable tension. The estimated tension of the cable based on field measurements and estimated tension of cable by numerical analysis were compared with the estimated tension of the cable based on field measurements. The analysis showed that the measured tension of the cable based on field measurements was within the margin of error. Therefore, it is safe to apply these measuring devices to the site. As a result of comparing and analyzing the values of the acceleration-based cable estimation tension and numerical analysis of the field demonstration bridge, the acceleration-based cable estimation of tension is deemed appropriate within the allowable range. On-site applicability analysis revealed limitations of the measuring devices, such as the installation location of sensors and weather conditions, so continuous follow-up research on smart cable tension measuring systems is expected.

Inelastic Dynamic Analysis of Structure Subjected to Across-Wind Load (풍직각방향 풍하중이 작용하는 구조물의 비탄성 동적 해석)

  • Ju-Won Kim
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.3
    • /
    • pp.185-192
    • /
    • 2023
  • In this study, fluctuating wind velocity for time history analysis is simulated by a single variate, single-dimensional random process using the KBC2022 spectrum about across-wind direction. This study analyzed and obtained the inelastic dynamic response for structures modeled as a single-degree-of-freedom system. It is assumed that the wind response is excellent in the primary mode, the change in vibration owing to plasticization is minor, along-wind vibration and across-wind vibration are independent, and the effect of torsional vibration is small. The numerical results, obtained by the Newmark-𝛽 method, shows the time-history responses and trends of maximum displacements. As a result of analyzing the inelastic dynamic response of the structure with the second stiffness ratio(𝛼) and yield displacement ratio (𝛽) as variables, it is identified that as the yield displacement ratio (𝛽) increases when the second stiffness ratio is constant, the maximum displacement ratio decreases, then reaches a minimum value, and then increases. When the stiffness ratio is greater than 0.5, there is a yield point ratio at which the maximum displacement ratio is less than 1, indicating that the maximum deformation is reduced compared to the elastically designed building even if the inelastic behavior is permitted in the inelastic wind design.

Consideration on Limitations of Square and Cube Root Scaled Distances in Controled Blast Design (제어발파설계에서 자승근 및 삼승근 환산거리 기법의 적용한계에 대한 고찰)

  • Choi, Byung-Hee;Ryu, Chang-Ha;Jeong, Ju-Hwan
    • Explosives and Blasting
    • /
    • v.28 no.1
    • /
    • pp.27-39
    • /
    • 2010
  • Blast design equations based on the concept of scaled distances can be obtained from the statistical analysis on measured peak particle velocity data of ground vibrations. These equations represents the minimum scale distance of various recommendations for safe blasting. Two types of scaled distance widely used in Korea are the square root scaled distance (SRSD) and cube root scaled distance (CRSD). Thus, the design equations have the forms of $D/\sqrt{W}{\geq}30m/kg^{1/2}$ and $D/\sqrt[3]{W}{\geq}60m/kg^{1/3}$ in the cases of SRSD and CRSD, respectively. With these equations and known distance, we can calculate the maximum charge weight per delay that can assure the safety of nearby structures against ground vibrations. The maximum charge weights per delay, however, are in the orders of $W=O(D^2)$ and $W=O(D^3)$ for SRSD and CRSD, respectively. So, compared with SRSD, the maximum charge for CRSD increases without bound especially after the intersection point of these two charge functions despite of the similar goodness of fits. To prevent structural damage that may be caused by the excessive charge in the case of CRSD, we suggest that CRSD be used within a specified distance slightly beyond the intersection point. The exact limit is up to the point, beyond which the charge difference of SRSD and CRSD begins to exceed the maximum difference between the two within the intersection point.

2,500 L/s 급 복합분자펌프의 특성평가 database 구축 및 표준화 기술 개발

  • Kim, Wan-Jung;Go, Mun-Gyu;Jeong, Wan-Seop;Im, Jong-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.167-167
    • /
    • 2011
  • 한국표준과학연구원에서는 국제표준화기구에서 제정한 국제규격(ISO, PNEUROP, DIN, JIS, AVS 등)에 기반을 둔 터보분자펌프의 특성평가시스템을 자체적으로 설계/제작 하였고, 터보분자펌프 1,000 L/s 급의 Database를 구축하였다. 이것을 토대로 특성평가시스템의 신뢰성 확인과 Feedback을 통한 시제품 개발 및 평가지원을 위해 터보분자펌프 2,500L/s 급의 Database를 구축한다. 터보분자펌프의 배기성능을 나타내는 가장 중요한 항목인 배기속도는 분자류 영역에 따라 상이한 가스($N_2$, He)를 사용하여 Throughput method와 Orifice method 두 가지 방법을 병행하여 측정한다. 측정함에 있어서 측정게이지, 유량계 및 Orifice conductance의 불확도에 의하여 배기 속도에 많은 측정오차를 포함하고 있다. 측정 오차를 줄이기 위하여 1% 이상의 안정성과 4%의 오차만을 허용하는 자전 회전자게이지(SRG)와 $10^{-3}$ mbar-L/s 영역까지의 유량 주입범위를 가지는 불확도 ${\pm}$3%의 정적형 유량시스템(CVFM)을 사용하였다. Orifice method의 경우 고진공영역으로 진입할수록 커질 수밖에 없는 배기속도 측정 불확도를 최소화하기 위해 검증된 유량을 이용한 Conductance 값을 제시하여 두 방법에서 얻은 배기속도의 불연속적인 문제를 해결한다. 본 연구에서는 2,500 L/s 급 터보분자펌프는 무거운 기체 $N_2$와 가벼운 기체 He을 사용하여 압축비의 변화와 분자류 영역에 따른 배기속도 변화를 연구하고, 2,500 L/s 급 터보분자펌프의 측정능력을 검증한다. 차후에 배기속도뿐만 아니라 소비전력, 소음, 진동, 온도 등의 특성평가의 전반적인 사항을 평가하여 터보분자펌프 2,500 L/s 급의 database를 완비해간다. 터보분자펌프 특성평가시스템을 사용한 1,000 L/s 급과 2,500 L/s 급 특성 Data를 비교, 분석하여 신뢰성 파악 및 표준화 방안을 개발하고, 고진공펌프 개발 주체와의 feedback 지원 기능의 infra를 구축한다.

  • PDF