• Title/Summary/Keyword: 진동과 풍하중

Search Result 84, Processing Time 0.024 seconds

모서리 절단 효과로 인한 사각주상체의 공기력 특성변화 전산해석

  • Hwang, Gyu-Gwan
    • Proceeding of EDISON Challenge
    • /
    • 2015.03a
    • /
    • pp.553-558
    • /
    • 2015
  • 교량의 주탑, 초고층빌딩과 같이 세장비가 큰 대형구조물의 경우 풍하중에 취약한 특성을 지니고 있어서 바람에 의해 직각 방향으로 발산 진동하는 갤로핑(galloping) 현상이 발생하게 된다. 구조물의 진동을 억제하려는 방안으로 단면 형상에 변화를 주어 공기역학적 불안정성을 감소시키는 방법이 사용되고 있다. 본 논문에서는 Edison_CFD를 이용하여 모서리 절단부의 비율과 받음각에 따른 공기력 특성에 대한 전산해석을 수행하였다.

  • PDF

Excitation System for Simulating Wind-induced Responses of a Building Structure using an Active Tuned Mass Damper (ATMD를 이용한 건축 구조물의 풍응답 구현을 위한 가진시스템)

  • Park, Eun-Churn;Lee, Sang-Hyun;Min, Kyung-Won;Kang, Kyung-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.210-215
    • /
    • 2007
  • In this paper, excitation systems using an active tuned mass damper (ATMD) are presented in order to simulate the wind induced responses of a building structure. The actuator force for the excitation systems is calculated by using the inverse transfer function of a target structural response to the actuator. The analyses results from a 76-story benchmark building problem in which wind load obtained by wind tunnel test is given, indicate that the excitation system installed at a specific floor can approximately embody the structural responses induced by the wind load applied to each floor of the structure. The excitation system designed by the proposed method can be effectively used for evaluating the wind response characteristics of a practical building structure and for obtaining an accurate analytical model of the building under wind load.

  • PDF

Measurement and Analysis of Wind Response of InCheon Bridge (인천대교의 풍응답 계측 및 분석)

  • Kim, Saang-Bum;Im, Duk-Ki;Park, Hyun-Woo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.340-343
    • /
    • 2011
  • 장대 케이블 교량의 풍응답을 계측할 수 있는 무선센서네트워크 기반의 풍응답 계측시스템을 개발하고, 이를 사용하여 인천대교의 시공단계별로 고유진동수, Mode Shape과 같은 Modal Parameters의 변화를 추정하고 보강형에서의 풍압분포와 보강형, 주탑, 케이블의 가속도를 계측하여 내풍 성능을 분석하였다. 개발된 계측 시스템은 인천대교 사장교의 전체 거동을 계측할 수 있도록, 1.5km 범위에 넓게 분포된 최대 55 Nodes에서 최대 1kHz의 동기화된 계측을 수행할 수 있으며, 각 Node별로 3축가속도나 풍압을 측정할 수 있다. 전체 Node에서 가속도를 계측하는 경우에는 최대 165 Channel을 1kHz로 측정할 수 있다. Modal 해석의 경우에, 고가교, 접속교, 사장교 주탑, 보강형, 케이블의 시공 단계별 동특성의 변화를 추정하였으며, 고가교에서는 모드해석을 통해 역추정한 구조계수를 정적재하실험 및 실험실에서의 Mold 시험결과와 비교하였으며 사장교 케이블에서는 케이블 댐퍼의 성능을 분석하였다. 또한 인천대교 보강형에서의 풍압분포를 계측하였으며, 풍압의 공간상관관계를 분석하였고, 풍하중 및 풍진동 특성을 분석하여 가속도 계측 결과와 비교하였다. 계측 및 분석 결과를 바탕으로 장대교량의 내풍성능을 확보하고 향상시키는데 활용할 수 있을 것으로 기대한다.

  • PDF

Evaluation of Shell Geometry of the Natural Draught Cooling Tower using Linear Numerical Analysis (선형 전산해석을 이용한 자연 습식 냉각탑의 기하형상에 대한 평가)

  • Noh, Sam-Young;Lee, Sang-Yun;Heo, Dong-Hyun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.3
    • /
    • pp.97-104
    • /
    • 2012
  • In the design procedure of the cooling tower the form-finding of the shell is the most important process, because the shape of the shell determines the sensitivity of dynamic behaviour of the whole tower against wind excitation. In engineering practice, geometric parameters of the shell are generally determined based on natural frequency analysis. 32 cooling tower shell geometries were selected through variation of the geometric parameters of an existing cooling tower shell. They were evaluated based on the first natural frequency. From the result three representative cooling towers are selected for the analysis of the structural behaviour by means of linear FE-method. As a result, a hyperbolic rotational shell with the small radius overall will yield the shell geometry with a higher first natural frequency and thus a wind-insensitive structure.

3-Dimensional Static and Dynamic Analysis of Soil-Framework Interaction System (지반-골조구조물 상호작용계의 3차원 정.동적 해석)

  • 서상근;장병순
    • Computational Structural Engineering
    • /
    • v.10 no.2
    • /
    • pp.243-254
    • /
    • 1997
  • When dynamic loads such as mechanical load, wind load, and seismic load, which causing a vibration, acts on the body of the 3-D framework resting on soil foundation, it is required to consider the dynamic behavior of soil-space framework interation system. Thus, this study presents the 3-dimensional soil-interaction system analyzed by finite element method using 4-node plate elements with flexibility, 2-node beam elements, and 8-node brick elements for the purpose of idealizing an actual structure into a geometric shape. The objective of this study is the formulation of the equation for a dynamic motion and the development of the finite element program which can analyze the dynamic behavior of soil-space framework interaction system.

  • PDF

Performance Evaluation of Vibration Control of High-rise Buildings Connected by Sky-Bridge (스카이브릿지로 연결된 고층건물의 진동제어 성능평가)

  • Kim, Hyun-Su;Yang, Ah-Ram;Lee, Dong-Guen;Ahn, Sang-Kyung;Oh, Jung-Keun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.4
    • /
    • pp.91-100
    • /
    • 2008
  • In this study, the vibration control performance of high-rise building structures connected by a sky-bridge has been investigated. The philosophy of vibration control using sky-bridges is to allow structures with different dynamic characteristics to exert control forces upon one another through sky-bridges to reduce the overall responses of the system. The the high-rise building structure connected by sky-bridge with 49 and 42 stories was used in this study to investigate the displacement, acceleration, reaction of bearings and stress of sky-bridge by analytical methods. To this end, historical earthquakes, an artificial earthquake and wind force time histories obtained from wind tunnel tests were used. Based on the analytial results, the use of sky-bridge can be effective in reducing the structural responses of high-rise buildings against wind and seismic loads.

  • PDF

Passive Control System for Mitigation of Cable Vibration in Cable-Stayed Bridges (사장교의 케이블 진동저감을 위한 수동 제어시스템)

  • Hwang, Inho;Lee, Jong Seh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5A
    • /
    • pp.881-885
    • /
    • 2006
  • Rain-wind induced cable vibration can cause serious problems in cable-stayed bridges. Externally attached dampers have been used to provide an effective means to suppress the vibration of relatively short stay-cables. For very long stay-cables, however, such damper systems are rendered ineffective, as the dampers need to be attached near the end of cables for aesthetic reasons. This paper investigates a new control system to mitigate the cable vibration. The proposed control system which consists of a laminated rubber bearing and an internal damper may be installed inside of the cable anchorage. A simple analytical model of the cable-damper system is developed first based on the taut string representation of the cable. The response of a cable with the proposed control system is obtained and then compared to those of the cable with and without an external passive damper. The proposed stay-cable vibration control system is shown to perform better than the optimal passive viscous damper, thereby demonstrating its applicability in large cable-stayed bridges for mitigation of rain-wind induced vibration of stay-cables.

Full Scale Measurement on Stay Cables of a Cable Stayed Bridgefor Estimation of Damping Ratios (실교량 계측에 기반한 사장 케이블의 감쇠비 추정)

  • Kim, Saang-Bum;Im, Duk-Ki;Kim, Chang-Hyun;Lee, Jong-Sup
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.421-424
    • /
    • 2009
  • 사장교 케이블의 감쇠비를 추정하기 위하여 실교량 계측을 수행하였다. 사장교 케이블은 감쇠비가 낮고, 고유 진동수가 케이블의 길이에 따라 넓은 범위에 걸쳐 분포하므로, 바람이나 지점 가진에 의하여 과도한 진동이 발생될 수 있다. 케이블 진동 현상의 원인과 발생되고 진행되는 구조는 다양하나, 진동 현상의 가장 중요한 요소는 감쇠비이며, 케이블 진동의 과도한 진동을 감소시키기 위하여, 케이블의 감쇠비를 증가시키는 방법이 널리 사용되고 있다. 사장교 케이블의 다양한 진동 현상에 대한 발생 여부를 판단하고, 케이블 댐퍼와 같은 여러 제진 대책을 설계하고, 설치된 케이블 제진 대책의 성능을 검증하기 위해서는, 케이블의 감쇠비를 추정하는 것이 매우 중요하다. 일반적으로 사용되어져 온 케이블의 감쇠비 추정 방법은 정해진 모드로 자유 진동을 발생시킨 후, 진폭의 감소 추세로부터 Logarithmic Decrement를 계산하여 감쇠비를 구하는 방법이다. 그러나 수백m에 이르는 긴 케이블에서 정해진 모드의 자유 진동을 발생시키는 것은 쉽지 않다. 최근에는 상시 진동으로부터 감쇠비를 추정하는 여러 기법들이 개발되어져 왔으며, Frequency Domain Decomposition Method나 Stochastic Subspace Identification Method 등이 많이 사용되고 있다. 이 논문에서는, 상시진동 기반의 기법들을 사용하여, 사장교 케이블의 감쇠비를 추정하였으며, 추정된 감쇠비의 신뢰도를 높이기 위해, 측정시간을 늘리고, 가진 풍하중의 영향을 반영하여 보정하였다. 또한 추정된 감쇠비를 Buffeting 진동과 와류 진동과 같이 진동 현상과 진폭별로 분석하였다.

  • PDF

Predictive Control of Structural Vibration Subject to Wind Loads (풍하중에 대한 구조진동의 예측제어)

  • 최창근;권대건;이은진
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1996.10a
    • /
    • pp.29-36
    • /
    • 1996
  • A procedure for the predictive control for structural vibration control in building subject to wind loads is presented. The building motions are modeled by the first mode of the response. Wind velocities are generated by the simulation using power spectral density function. Predictive control algorithm is the discrete-time formulation and that is developed as a control strategy that computes the control signal which makes the predicted process output equal to a desired process output. Results on the reduction of the dynamic response and control effectiveness of the algorithm are presented and discussed.

  • PDF

Characteristic of Vibration in Windturbine System (풍력발전시스템의 진동특성)

  • Kim, Jung-Su;Lee, Hyoung-Woo;Park, No-Gill;Kim, Young-Duk;Kim, Soo-Yum;Lee, Dong-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.786-795
    • /
    • 2011
  • This paper described the characteristic of vibration in wind turbine system including gearbox housing, gear drive, blade, generator. Especially, in planetary gear set, planet gears are supported by flexible pin. So, in planet gear, to consider not only torsional movement but also lateral movement. And include housing movement, because wind turbine system is supported by mount. To find out the characteristic of vibration, take the excitation source and study campbell diagram in operating range. Results of campbell diagram, resonances are occurred at 81.2HZ, 104.7Hz by 2nd tooth passing frequency. And resonance are also occurred at 264.5HZ, 377Hz, 424.6Hz by 3th tooth passing frequency. From the result, take vibration reduced measures.