• 제목/요약/키워드: 진공인터럽터

검색결과 26건 처리시간 0.028초

종자계형 진공인터럽터의 개발 (The Development of Axial Magnetic Field Type Vacuum Interrupter)

  • 박홍태;안희일;김성일;이경행
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.231-233
    • /
    • 2001
  • Axial magnetic field(AMF) type electrodes can be increase the interrupting capability of vacuum interrupters. Depending on the design, the principle of the local axial magnetic field arrangement are different. In this paper, a new AMF contact design based on a unipolar field arrangement and its characteristics are introduced. The influence of the unipolar AMF on the arc behavior is described by high-speed video camera. In addition, three-dimensional AMF simulations have been peformed by means of a finite element analysis(FEM) program to analyze the influence of magnetic field distribution on the AMF performance. The high interrupting capability of the unipolar AMF type electrode has been confirmed by three-phase test.

  • PDF

진공인터럽터 외부쉴드가 절연성능에 미치는 영향 분석 (An Analysis of Insulation Performance Result from Shield of Outside Vacuum interrupter)

  • 윤재훈;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.100-100
    • /
    • 2010
  • Because of power consumption increase, global wanning, and limitation of installation, not only high reliability and interruption capability but also compact and light power apparatuses are needed. To improve the insulation performance, the high E field concentration phenomena was considered. Breakdown mechanism in vacuum is different from that in other insulation materials. therefore, It is necessary to understand the electric field distribution and insulation characteristics. This paper discusses the simulation and LI(light impulse) test of the shield of outside vacuum interrupter As a result, FEM simulation and LI test show that improve distribution of electrical field and equi-potential line. due to external shield. in this case, outside shield induced electric field of triple junction point.

  • PDF

진공인터럽터 내부 shield gap에 따른 전계분포해석 (Electric field distribution analysis along shield gap inner vacuum interrupter)

  • 윤재훈;김병철;이승수;임기조;강성화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1368-1369
    • /
    • 2008
  • This paper describes the electric field distribution analysis along a shield form inner vacuum interrupter(VI). The equipotential line and electric field and field vector in a VI are analysed by a finite element method at various shield form. in result, The equipotential line and electric field distribution was affected to VI shield gap. The reason is as it gets distortion of equipotential line done. finally, this paper recognized whether or not affected, and proposed gap with the most suitable shield length and an external insulation.

  • PDF

유한요소해석을 통한 횡자계 방식의 진공인터럽터 전극의 로렌츠 힘 분석 (Analysis of Lorentz force of radial magnetic field type vacuum interrupter using finite element method)

  • 김병철;윤재훈;허준;강성화;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1197-1198
    • /
    • 2008
  • There have been few papers using finite element method(FEM) to analyze arc driving force for spiral type vacuum interrupter electrode up to date while there have been many papers dealing with AMF type electrode by means of FEM. AMF analysis is very important in AMF type electrode because it has proportional relation with effective area which means the area of magnetic flux density above critical magnetic flux density to diffuse arc. In the same manner, arc driving force is an important factor to drive arc by Lorentz force. In this paper two models were calculated and compared by using commercial FEM software Maxwell 3D.

  • PDF

진공회로차단기용 횡자계방식 접점의 충격해석 (Impact Analysis of Spiral type Electrodes in Vacuum Circuit Breaker)

  • 박우진;안길영;오일성;허훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.895-900
    • /
    • 2001
  • It is very important for impact analysis to reflect the dynamic characteristics of materials as well as the static characteristics. As the dynamic behavior of a material is different from the static(or quasi-static) one due to the inertia effect and the stress wave propagation, an adequate experimental technique has to be developed to obtain the dynamic responses for the corresponding level of the strain rate. To determine the dynamic characteristics of materials, the Hopkinson bar (compression type) experiment is carried out. For using dynamic material properties, Johnson-Cook model is applied in impact analysis with explicit finite element method

  • PDF

축자계형 진공인터럽터의 전자계 현상 해석 (Analysis of the Electromagnetic Phenomena in Vacuum Interrupter with Axial Magnetic Field Type)

  • 하성철;서상현
    • 한국전기전자재료학회논문지
    • /
    • 제16권10호
    • /
    • pp.952-957
    • /
    • 2003
  • The purpose of this paper is analyses about in 12kV/50kA vacuum interrupter with an axial magnetic field type electrode system through the studies of electromagnetic phenomena. Vacuum interrupter is important in electric safety part. In this paper, we performed analysis of electric field, magnetic field, current density in AMF electrode using the Maxwell 3D simulation. The current distribution and magnetic field in simple models are analyzed to verify its efficiency and accuracy. In addition the validity of FEM is confirmed by performing the analyses of distribution in current density and magnetic flux density.

유한요소법을 이용한 진공인터럽터 절연설계 기초연구 (The Basic Study on the Insulation Design of Vacuum Interrupter using Finite Element Method)

  • 박치영;안희일;함길호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1635-1637
    • /
    • 1998
  • This paper describes on the basic study for the insulation design of vacuum interrupter using Finite Element Method. For the basic study of insulation design, first, the maximum electric field was calculated on each curvature radius of arc shield and electrode. Second, the maximum electric field was also calculated on applied voltage and end shield with or not. Thus, the maximum electric field calculated have an effect on curvature radius and voltage polarity.

  • PDF

종자계방식 진공인터럽터 개발에 관한 연구 (A Study on the Development of Vacuum Interrupter with Axial Magnetic Field type)

  • 김성일;박홍태;안희일;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.943-945
    • /
    • 2000
  • In this paper described that study on the distribution and characteristics of axial magnetic field by mathematical analysis and experiment for axial magnetic field type vacuum interrupter that important part on vacuum circuit breaker. And, it was shown that inspected results of arc shape at breaking the current by typical axial magnetic field type model and new axial magnetic field type model.

  • PDF

고차단용량 진공인터럽터의 AMF 전극 비교연구 (Comparison of AMF Contacts for High Interrupting Capacity Vacuum Interrupter)

  • 김진수;최명준;류성식;김익모;최영찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1863-1865
    • /
    • 2004
  • As rise the demands for the protcetion of environment and the compactness of equipments, the movement brisks for replacing the circuit breaker of GIS(Gas Insulated Switchgear) to VI(Vacuum Interrupter). For these reason an increase in the interruption capability of VI is required. To satisfy these requirement, the academic and industrial worlds have been studying extensively for AMF(Axial Magnetic Field) contact, which is effective in interrupting large current over tens of kA, and introduced many kind of AMF contacts. However there are little effort to compare these contacts comprehensively, so it is difficult to choose most suitable shape for user's needs. In this paper, focusing unipolar type contact among various type of AMF contacts, we performed magnetic field analysis for several models designed in same dimension and compared the result and characteristics of each model in order to help deciding the direction for developing profitable VIs for interrupting large current.

  • PDF

진공 인터럽터의 차폐판이 절연에 미치는 영향의 유한요소해석 (A Finite Element Analysis on the Influence of Floating Shield of a Vacuum Interrupter to the Insulation)

  • 최승길;심재학;강형부
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.113-116
    • /
    • 1998
  • This study should investigate to what extent the electric field of a vacuum interrupter might be influenced by the electric potential of floating arc shield. The electric potentials of floating shield and electric fields of a vacuum interrupter are analysed by a finite element method against variation of gap distances from 1mm to 12mm. The electric potentials of floating shield was increased with the gap distance, which is because the relative position of shield is closer to fixed contact so that the capacitance distribution inside interrupter is varied. The calculated results show that the maximum value of electric field of a vacuum interrupter with floating shield is nearly same to that without shield at shorter gap distance(below 5mm), however at larger gaps a significant increment of electric field is achieved in interrupter with shield companying with model without shield, which is due to the influence of charged floating shield.

  • PDF