• Title/Summary/Keyword: 지하수 온도

Search Result 322, Processing Time 0.031 seconds

A Numerical Analysis to Predict the Temperature Distribution around a Cold Storage Cavern (지하암반 냉동저장고 주변의 온도분포 예측을 위한 수치해석)

  • 이규상;이정인
    • Tunnel and Underground Space
    • /
    • v.14 no.4
    • /
    • pp.287-294
    • /
    • 2004
  • To predict the temperature distribution around a underground rock storage cavern, two- and three- dimensional numerical analysis using FLAC was conducted. The effects of groundwater and latent heat on thermal properties were considered in numerical calculation. The temperature estimated by FLAC are compared with the temperature measured for 5-year operation at Gonjiam storage cavern. Estimated and measured temperatures showed great discrepancy when thermal properties from laboratory tests were used and showed good agreement when the effects from 20% of volumetric water fraction and latent heat were considered. However, the discrepancy still increased with operation time due to the heat flow from ground surface. Three-dimensional numerical models were established to closely approximate the boundary condition of the test site, and numerical results better agreement when groundwater and latent heat effects were considered.

생물학적 복원기술에 의한 유류 오염토양의 정화

  • 강희만;이주광;이용은;권수열
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.164-167
    • /
    • 2001
  • 현장에서 채취한 토양을 이용하여 Microcosm test를 실시한 결과 온도 및 수분함량이 높을수록 BTEX 분해율이 증가하는 것으로 나타났으며 산소 농도는 21~32% 정도가 적당하였다. 그러나 BTEX 초기농도가 높은 경우에는 생분해율이 감소하는 것으로 나타났다. Bioventing 공법을 현장에 적용한 결과 OUR(Oxygen Utilization Rate)값은 6.3~16.3%O$_2$/day로 조사되었으며 Biodegradation rate 값은 3.4~8.8 mg hydrocarbon/kg soil/day로 조사되어 생물학적 처리 가능성이 있는 것으로 평가되었다.

  • PDF

Factors affecting deuterium-excess values of precipitation (강수의 중수소과잉값에 영향을 주는 요인들)

  • 이광식;박원배;이대하;고동찬
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.152-155
    • /
    • 2002
  • 강수의 중수소과잉값(d-값)은 바다와 대기와의 접촉 과정에 의하여 일차적으로 지배되지만 빗방울의 부분증발, 응축온도의 변화 또는 d-값이 다른 수증기와의 혼합에 의하여 이차적으로 변화될 수 있다. 이 연구에서는 동북아시아 강수의 d-값 변화에 영향을 미치는 요인들에 대하여 논의하였다. 아울러 제주도 한라산에 내리는 강수의 d-값이 고도가 높아짐에 따라 커지는 원인에 대하여 검토하였다.

  • PDF

Evaluation of Potential Amount of Groundwater Development in Chungju Basin by Using Watershed Hydrologic Model and Frequency Analysis (유역수문모형과 빈도해석을 이용한 충주댐 상류유역 지하수 개발가능량의 평가)

  • Lee, Jeong-Eun;Kim, Nam-Won;Chung, Il-Moon;Lee, Jeong-Woo
    • Economic and Environmental Geology
    • /
    • v.41 no.4
    • /
    • pp.443-451
    • /
    • 2008
  • Memon(1995) pointed out that the groundwater recharge from the precipitation is affected by various factors such as the occurrence, intensity, duration, and seasonal distribution of rainfall; air temperature, humidity, and wind velocity; the character and thickness of the soil layer above the water table; vegetated cover, soil moisture content, depth to the water table, topography; and land use. To reflect above factors, groundwater recharge in Chungju basin is computed by using the SWAT-K which is a longterm continuous watershed hydrologic model. Frequency analysis is adopted to evaluate the existing values of potential amount of groundwater development which is made by the 10 year drought frequency rainfall multiplied by recharge coefficient. In this work, the recharge rates of 10 year drought frequency in subbains were computed and compared with the existing values of potential amount of groundwater development. This process could point out the problems of existing precesses used for computing potential amount of groundwater development.

Complexity of Groundwater Flow System in a Site Reflected in the Fluctuations of Groundwater Level and Temperature (지하수위와 수온 변동에 나타난 부지 규모 지하수 흐름장의 복잡성)

  • Jonghoon Park;Dongyeop Lee;Nam C. Woo
    • Economic and Environmental Geology
    • /
    • v.55 no.6
    • /
    • pp.563-570
    • /
    • 2022
  • This study was objected to show the complexity of groundwater flow system in a site-scale area as a design parameter of the groundwater monitoring network for early detection of pollutant leakage from a potential source of groundwater contamination (e.g., storage tank). Around the tanks, three monitoring wells were installed at about 22~25 m deep and groundwater level and temperature had been monitored for 22 months by 2-minute interval, and then compared with precipitation and temperature data from nearby weather station. Annual variation of groundwater level and its response to precipitation event, variation of groundwater temperature and delayed response to that of atmospheric temperature indicate the complexity of groundwater flow and flow paths even in the relatively small area. Thus, groundwater monitoring network for early detection of contaminant leakage should be designed with full consideration of the complexity of groundwater flow system, identified from the detailed hydrogeological investigation of the site.

Thermo-hydraulic Modeling in Fault Zones (단층대에서의 열-수리적 거동 모델링)

  • Lee, Young-Min;Kim, Jong-Chan;Koo, Min-Ho;Keehm, Young-Seuk
    • Economic and Environmental Geology
    • /
    • v.42 no.6
    • /
    • pp.609-618
    • /
    • 2009
  • High permeable faults are important geological structures for fluid flow, energy, and solute transport. Therefore, high permeable faults play an important role in the formation of hydrothermal fluid (or hot spring), high heat flow, and hydrothermal ore deposits. We conducted 2-D coupled thermal and hydraulic modeling to examine thermohydraulic behavior in fault zones with various permeabilities and geometric conditions. The results indicate discharge temperature in fault zones increases with increasing fault permeability. In addition, discharge temperature in fault zones is linearly correlated with Peclet number ($R^2=0.98$). If Peclet number is greater than 1, discharge temperature in fault zones can be higher than $32^{\circ}C$. In this case, convection is dominant against conduction for the heat transfer in fault zones.

Capacity Modulation of a Ground Source Multi-Heat Pump in the Part Load Condtions (축열형 지열원 냉난방 시스템의 단기 성능 특성 연구)

  • Kim, Namtae;Cho, Chanyong;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.119-119
    • /
    • 2010
  • 무한 지속 가능한 지열 에너지를 활용한 공조시스템인 지열원 냉난방 시스템은 기존의 공조 시스템보다 열원이 안정적이기 때문에 높은 효율과 우수한 성능을 가지므로, 기후변화협약 대응의 주요수단으로서 기술개발과 보급이 증대되고 있다. 본 연구에서는 대수층 축열 지열원 열펌프 시스템에 대한 실증 연구를 통하여 대수층 축열 지열원 열펌프 시스템의 하절기 냉방 성능을 분석하였다. 대수층 축열 냉난방 시스템은 주입정과 양수정의 2개의 우물공이 설치되어 있으며, 겨울 난방 운전 중에 한 개의 우물공으로부터 지하수를 열펌프로 유입한 후 낮은 온도의 지하수를 타 우물공에 축열하고, 하절기에 겨울에 저온으로 축열된 우물공으로부터 지하수를 열펌프로 유입하여 온도가 증가된 지하수를 타 우물공에 주입한다. 즉, 계절별로 열펌프에서 생성된 냉수와 온수의 대수층 축열을 위하여 계절별로 주입정과 양수정이 바뀌게 된다. 본 연구의 대수층 축열 지열원 열펌프 시스템의 2009년 8월의 주요일자별 시스템 운전 중의 평균 냉방 열펌프 유닛 COP와 냉방 시스템 COP는 각각 4.7과 3.4이상의 우수한 성능을 나타냈다. 또한, 모든 일자에 대하여 외기온도가 $31.6^{\circ}C$$22^{\circ}C$까지 변화가 크게 나타났지만 열펌프 유닛 COP와 시스템 COP의 변화는 미소하였다. 이는 양수정으로부터의 지중 순환수가 운전기간 중에 $17.5^{\circ}C$로 일정하게 유지되었기 때문이다. 양수정과 주입정 사이에 5개의 관측공을 설치하였으며, 양수정 측에 인접한 관측공의 온도는 거의 변화가 없었으며, 단기간이지만 널리 사용되고 있는 수직밀폐형 시스템과 달리 지속적인 냉방운전 중의 양수 온도의 증가는 발생하지 않아 안정적인 성능을 나타냈다. 주입정에 인접한 모니터링 홀의 온도는 심도가 깊은 곳의 온도가 낮은 곳보다 높게 나타났다. 이는 냉방 운전 시 열펌프 유닛의 실외열교환기에서 지중 순환수가 냉매로부터 열을 취득하여 온도가 상승하면서 주입정측에 온열이 축열이 진행되었기 때문으로 분석되며, 하절기의 냉방 운전 시간이 증가할 경우 축열 효과는 더욱 증가할 것으로 예상된다. 양수정과 주입정 중간의 모니터링 홀의 온도는 2009년 8월 가동 중에 온도변화는 없었는데, 이는 양수정과 주입정 사이의 열간섭이 발생하지 않았기 때문으로 분석된다. 일자별로 운전 중의 열펌프 유닛 COP는 차이가 없었지만, 운전 및 정지 시간을 모두 포함한 시스템 소비전력과 냉방용량을 모두 합산하여 산정한 일일 평균 냉방 열펌프 유닛 COP와 냉방 시스템 COP는 일자별로 다소 차이가 발생하였는데, 이는 각 일자별로 열펌프 유닛 가동율의 차이로 인하여 열펌프 유닛 가동 전에 먼저 작동되는 지중순환펌프의 운전 소비전력의 차이와 열펌프의 단속운전 시의 열손실과 추거 소비전력의 차이 때문이다.

  • PDF

Estimation of reservoir temperatures and subsurface environments for $CO_2-rich$ springs in Kangwon Province (강원도 지역 탄산용출수에 대한 심부온도 및 심부환경의 추정)

  • 최현수;고용권;윤성택;배대석
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.520-523
    • /
    • 2003
  • 강원도 지역의 대표적인 탄산용출수에 대한 수리지구화학적 연구를 통하여 심부 지열 저장지의 온도와 심부환경을 추정하였다. 탄산용출수는 공통적으로 약산성의 pH와 높은 이온함량으로 특징되지만, 화학적으로는 Na-HCO$_3$형, Ca-Na-HCO$_3$형, 그리고 Ca-HCO$_3$형으로 뚜렷이 구분된다. 심부에서 생성된 탄산용출수가 지표로 상승하는 도중에 수반된 지표수 혼합차이로 인해 이런 화학조성의 차이가 유발된 것으로 판단된다. Na-HCO$_3$형 탄산수는 화학 조성상 ‘mature water’의 특징을 보여주는 반면, 다른 두 유형의 탄산수들은 ‘immature water’에 해당하였다. Na-HCO$_3$ 형 탄산수에 대하여 실리카, Na-K 및 Na-K-Ca 지온계를 적용한 결과, 약 l15-157도의 심부저장지 온도가 산출되었으며, 이 결과는 다성분 평형계를 이용한 추정 온도 (약 140-160도)와도 잘 일치하였다. 반면, Ca-HCO$_3$ 형 탄산수들은 지표수와의 혼합 때문에 상대적으로 낮고 넓은 범위의 추정 온도 (약 60-130도)를 나타내었다. 따라서 연구지역 내 탄산용출수의 심부저장지 온도는 Na-HCO$_3$형에 대해서만 타당하게 적용될 수 있으며, 약 140-160도일 것으로 추정된다.

  • PDF

A Study on the Application of Groundwater Dam (지하수댐 활용방안에 관한 연구)

  • Lee, Gyumin;Kim, Jinsoo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.489-489
    • /
    • 2018
  • 최근 기후변화의 영향으로 가뭄의 발생빈도 및 규모가 증가하고 있다. 이에 지자체를 중심으로 대체 수자원 확보를 목적으로 지하수의 개발이 늘어나고 있는 추세이다. 국내에서는 지하수 개발 이용시설로 관정(管井)을 활용하는 것이 일반적이나, 최근에는 낙도를 중심으로 대규모 지하수자원 확보를 위한 지하수댐 건설이 논의되고 있다. 현재 우리나라에는 6개의 지하수댐이 설치 운영되고 있는데, 가장 최근에 건설된 지하수댐도 20여 년이 지난 1998년에 건설되었다. 게다가 국내에 건설된 지하수댐은 지하수맥을 이용하기 보다는, 건천화된 시기에도 하천수를 이용하기 위해 하천의 지하에 건설되어 있어 일반적인 개념의 지하수댐이라고 보기 어렵다. 지하수댐의 활용을 통해 지하수자원을 효율적으로 확보하기 위해서는 첫째, 지하수에 대한 기초자료의 확보가 필요하다. 현재 지하수법 제5조에 따라 전국 지하수에 대한 기초조사를 실시하고 10년마다 보완조사를 실시하여야 한다. 그러나 1997년부터 실시되고 있는 기초조사는 예산 및 인력 부족 등으로 아직까지 전국 전체에 대한 자료가 마련되지 못하고 있으며, 보완조사는 아직까지 실시된 바가 없는 실정이다. 조속히 지하수 기초조사를 완료하여 전국에 대한 수문지질도(水文地質圖)를 작성하고, 이를 바탕으로 체계적인 지하수댐 조성계획을 수립할 필요가 있다. 둘째, 지하수댐 건설기술에 대한 체계적인 연구가 필요하다. 현재 조성된 하천 지하에 건설된 지하수댐이 아닌, 지하수맥을 이용하는 본래의 용도에 적합한 지하수댐을 건설하기 위한 세부기술의 확보가 필요해 보인다. 셋째, 현행 지하 충전수에 대한 수질기준을 확대할 필요가 있다. 현재 하수 폐수 및 온배수 재처리수로 지하수를 함양할 경우의 수질기준은 시 도지사가 관할 구역에 대하여 수립하는 '지역지하수관리계획'에 포함된 경우로만 되어 있어, 국가 또는 개인이 지하수를 함양할 경우에 적용되는 수질기준이 부재한 상태다. 또한 지하수 충전 깊이에 따라 토양에서 발생하는 정화능력에 차이가 있으므로, 수질기준에 차등을 두어 합리적으로 적용할 필요가 있다.

  • PDF