• Title/Summary/Keyword: 지진의 등가정적해석

Search Result 59, Processing Time 0.022 seconds

The Study on Seismic Stability Evaluation Model for Rock Foundation of Nuclear Power Plant (원전 기초지반의 지진안정성 평가 모델 연구)

  • Hwang, Seong-Chun;Jang, Jung-Bum
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.4 s.44
    • /
    • pp.1-10
    • /
    • 2005
  • The purpose ol this study Is to suggest a proper analysis model that can evaluate seismic stability for local rock foundation of nuclear power plant. Sliding Analysis, Pseudo-static Analysis and Dynamic Analysis methods are used for analysing NPP rock foundation with the conditions like acting directions of input earthquake, boundary conditions, width and depth of analysing model, and modeling methods of weakness fault zones. As the results of study, Pseudo-static Analysis for lateral roller and dynamic analysis for transfer boundary condition showed good results, and analysing ranges of width and depth were 5 times of structure width and over 2 times ol structure depth.

Propose of Capacity Spectrum Method by Nonlinear Earthquake Response Analysis (질점계 비선형 지진응답해석에 의한 구조물의 역량스펙트럼 제안)

  • You, Jin-Sun;Yang, Won-Jik;Yi, Waon-Ho;Kim, Hyoung-Joon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.6
    • /
    • pp.501-508
    • /
    • 2014
  • In this paper, a method on deducing the capacity spectrum based on nonlinear earthquake response analysis will be introduced. Damage assessment of general building draws the capacity spectrum through the Push-over analysis and the intersection point of capacity spectrum and demand spectrum is seen as performance point. Push-over analysis is the way to perform static analysis by using the equivalent static load changed from the effect of earthquake and predict the behavior of structures by earthquake. But, this method can not be taken into account in the effects of higher mode and the dynamic characteristic. Therefore, in order to calculate the capacity spectrum under dynamic properties of building. A capacity spectrum from going ahead with the nonlinear earthquake response analysis is suggested.

A Study on Seismic Retrofit Design of the Stabilized Piles by 1g Shaking Table Tests and Pseudo-static Analysis (1g 진동대 실험 및 등가정적해석을 이용한 억지말뚝의 사면안정 내진보강 효과 연구)

  • Han, Jin-Tae;Cho, Jong-Suck;Yoo, Min-Taek;Lee, Seung-Hyun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.2
    • /
    • pp.93-101
    • /
    • 2011
  • Korea has about 70% of its land classified as the mountain area, which has led to cut-slope being the result of substantial road and railway construction. However, there is currently a lack of research about the seismic retrofit design of a slope, even though many earthquakes have recently occurred at home and abroad. In this study, in order to investigate the stabilizing effect of piles against sliding during an earthquake, a series of 1 g shaking table tests and pseudo-static analyses were carried out. As a result, the stabilizing effect of piles against sliding during an earthquake was verified by the 1 g shaking table tests and the most effective result from the pseudo-static analyses was that the installation of the piles on the central part of the slope, where the failure surface included piles unlike the lower part and upper part of the slope. Furthermore, when the pile was installed on the central part of the slope, the change of the safety factor depending on the distance between the center of two piles was evaluated.

Evaluation of Lateral Load Resistance Capacity of a High-rise Shear Wall Apartment Based on Elasto-plastic Analaysis (정적 탄소성 해석에 의한 고층 벽식 아파트의 수평내력 검토)

  • 전대한;강호근;조한욱;이정원
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.31-40
    • /
    • 1998
  • The purpose of this study is to investigate static elastoplastic behaviour and estimate ultimate resistance capacity of a high-rise apartment shear wall system subjected to a vertical distribution of lateral loading along the height. A typical 25-story two unit plan apartment is selected as a representive model. For the analysis, the pushover analysis is adopted to estimate initial elastic stiffness, post-yielding stiffness and story shear yield resistance level on each story of the structure through three-dimensional nonlinear analysis program-CANNY. In the result of elastoplastic analysis, it is observed that the yield strength of building structures is 1.6 times larger than required lateral design strength.

  • PDF

A Study on the Equivalent Static Analysis of Unreinforced Masonry Buildings (비보강 조적조 건물의 등가 정적 해석에 관한 연구)

  • 정상훈;김관중;김희철
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.3
    • /
    • pp.1-10
    • /
    • 2000
  • 우리 나라의 주거 건물의 많은 부분을 차지하는 조적조 건물은 저층이므로 내진 설계에 대한 지침이 마련되어 있지 않다. 그러나 조적조 건물의 경우 저층이라 하더라도 구조특성상 수평하중에 대한 저항능력이 매우 약하므로 내진 설계에 대한 기준이 요구된다. 일반적으로 내진설계 시 동적 해석을 수행하면 많은 시간이 소모되므로 실무자들에게 등가정적해석법을 제시하여 내진설계 시 편의를 제공하고 있다. 그러나 저층 조적조 건물은 일반적인 건물과는 거동 특성이 다르므로 저층 조적조 건물에 적용할 수 있는 해석법을 제시하고자 한다. 본 논문에서는 개구부의 비율에 따른 조적벽의 연성도, 강도 및 고유주기를 구하여 반응수정계수와 고유주기를 비교하여 우리 나라의 조적조 건물에 적합한 반응수정계수와 고유주기 산정식을 제안하였다.

  • PDF

Seismic Performance Evaluation of a School Gymnasium Using Static Anlysis (정적해석에 의한 학교 체육관의 내진 성능 평가)

  • Morooka, Shigehiro;Tsuda, Seita;Ohsaki, Makoto
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.4
    • /
    • pp.49-59
    • /
    • 2009
  • The seismic responses of small-scale spatial frames such as school gymnasiums are usually evaluated using static analysis, although time-history analysis should be carried out to fully incorporate the dynamic responses of the structures against seismic motions. In this study, advanced static analysis procedures arc presented for school gymnasiums that will improve the performance evaluation against seismic motions. The seismic loads are approximated by equivalent static loads corresponding to the two performance levels; i.e., Levels 1 and 2 defined by the Japanese building standard. The importance of utilizing the eigenmode in the load pattern is discussed. Simple static analysis procedures are presented for evaluation of maximum vertical acceleration. It is shown that the static analysis for Level 2 input significantly underestimates the responses by dynamic analysis; however, the inelastic responses for Level 2 are shown to be successfully evaluated using the equivalent linearization that is similar to the $^{\circ}$Dmethod based on calculation of limit strength$^{\circ}{\pm}$ for building frames in Japan.

  • PDF

건축물의 내진설계를 위한 구조동력학-제 1부:단자유도 구조물의 지진해석과 응답스펙트럼

  • Lee, Dong-Geun
    • 건축구조
    • /
    • v.13 no.1
    • /
    • pp.46-58
    • /
    • 2006
  • 구조동력학 이론에 기초하여 내진설계 기술이 개발되었다. 그러므로 건축물의 내진설계를 근본적으로 이해하기 위해서는 구조동력학의 여러 가지 이론들을 먼저 알고 이들이 내진설계에 어떻게 적용이 되는지를 알아야 한다. 이 글은 구조기술자 여러분이 건축물의 내진설계를 이해하는데 도움이 될 수 있도록 하기 위하여 다음과 같이 3부로연재될예정이다. 제1부: 응답스펙트럼과구조물의동적해석 제2부: 등가정적해석법과반응수정계수의배경 제3부: 능력스펙트럼법에의한비탄성해석 제1부에서는 단자유도 구조물의 지진해석을 통하여 응답스펙트럼을 작성하는 원리와 이를 이용하여 간편하게 지진해석을 수행하는 방법을 소개하고 응답스펙트럼에 근거하여 설계응답스펙트럼을 작성하는 방법과 다자유도 구조물의 지진응답을 알아내기 위한 응답 스펙트럼 해석법에 관하여 소개한다. 제2부에서는 구조동력학 이론에 근거하여 등가정적해석법이 유도된 근거와 반응수정계수를 사용하게 되는 배경을 소개하여 구조기술자들이내진설계에좀더확실한이해를할수있도록할것이다. 마지막으로 제3부에서는 비탄성해석을 좀 더 쉽게 하기 위하여 사용되는 능력스펙트럼법의 배경과 이를 이용하여 건축물의 성능점을 찾는 방법과 구조물의 비탄성 지진응답을 평가하는 방법에 대하여 소개함으로써 성능에 기초한 내진설계를 위한 기초 이론을 확실히 이해할수있도록할것이다. 구조동력학에 관한 내용을 여기에 상세히 소개하자면 엄청난 분량이 될 것이므로 여기서는 이 글을 읽는 구조기술자들이 구조동력학에 관한 기초적인 내용을 이해하고 있는 것으로 가정하기로 한다. 그러므로 구조동력학에 대한 기초적 이론을 확실히 이해하고 있지 못한분들은이글을읽기전에먼저구조동력학에관한알기쉬운서적을 먼저 읽도록 추천한다.

  • PDF

원자력 발전소 건물의 내진해석 모델

  • Heo, Young
    • Computational Structural Engineering
    • /
    • v.4 no.1
    • /
    • pp.17-19
    • /
    • 1991
  • 본 글에서는 ANS(American Nuclear Society)에서 규정하고 있는 Safety Class 구조물 중 격납건물의 내진해석모델에 대해 주로 언급하며, 기타 건물(Non-Nuclear Safety "NNS")은 일반건물과 차이점이 없음으로 언급하지 않는다. U.S. NRC(Nuclear Regulatory Commision)는 참고문헌[1]에 의해 원자력 발전소내 여러건물중 SSE(Safe Shutdown Earthquake)하중에도 견디도록 규정하여 정확한 동력학적 계산이 요구되어지나, 그 이외의 건물들은 대개 등가정적 방법에 의해 해석되어진다. 이 해석방법은 여러 빌딩규정들에서 제안된 것으로 지진에 의한 동적하중을 밑면적 단력 또는 각층에 작용하는 층전단력이라는 등가의 정적하중으로 바꿔 계산되며 이 때 사용되는 해석모델은 건물의 기본진동만을 표시할 수 있는 간단한 것이다.

  • PDF

Evaluation of the Application and Analysis Method at Seismic Design of Dam (댐의 내진설계시 해석방법과 그 적용성 평가)

  • Hwang, Seong-Chun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.4239-4249
    • /
    • 2011
  • In the country with frequent earthquakes like Japan, resistance to earthquake is assessed on the basis that Dam body's Face slab is destroyed by concentrated stress. In our country this kind of modeling and analysis is not yet definitely established. This paper performed pseudo static analysis and dynamic analysis for CFRD and evaluated reliability with the results of Shaking Table Test. The Seismic coefficient method, modified seismic coefficient method, Newmark method of Pseudo-static analysis and frequency domain response analysis, time domain history analysis of dinamic analysis were used. The analysis results were differ between analysis method, but the trends of acceleration and displacement were good agreement with the results of shaking table test.

The Evaluation of the Structural Integrity of Bellows Globe Valve for Nuclear Power (원자력 발전소용 벨로우즈 글로브 밸브에 대한 구조 건전성 평가)

  • Chung, Chul-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.6
    • /
    • pp.1034-1039
    • /
    • 2006
  • The purpose of this paper is to evaluate the structural integrity of the Class 1500 Bellows Seal 3 inch globe valve classified as seismic category IIA. The finite element analysis program, ANSYS, Version 10.0, is used to perform both a modal frequency analysis and an equivalent static stress analysis of the subject valve modeling. The modal frequency analysis results show the fundamental natural frequency is greater than 33 Hz. Therefore the equivalent static stress analysis is performed using the seismic acceleration values. The stresses resulted from various loadings and their combinations are evaluated based on the structural acceptance criteria of the ASME Code. The stresses in the glove valve due to the seismic loadings are within the allowable limits. It is concluded that the globe valve structure is maintaining the structural integrity fur the seismic loading conditions.

  • PDF