A Study on the Design of H-Section Steel Column Baseplate under Concentric Loadings (중심 축하중을 받는 H형강 기둥 베이스플레이트의 설계에 대한 연구)

  • Lee, Seung Joon;Lee, Jae Han
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.6 s.79
    • /
    • pp.717-726
    • /
    • 2005
  • This study investigates the bearing pressure distribution and design of an H-section steel column baseplate under concentric loading. In general, the size and thickness of the baseplate are determined with the assumption that the bearing pressure of the column baseplate is distributed uniformly. When the column is loaded lightly, however, the baseplate becomes smaller andthinner and the bearing pressure of the baseplate is distributed non-uniformly. In this study, the distribution of the bearing pressure is investigated using the experimental method and the analytical method. Seven specimens of the H-section steel column baseplate were fabricated and tested. The analysis of the specimens was performed using the finite element analysis program, ANSYS. It is not appropriate to use the Limit State Design,which assumes that the bearing pressure of the baseplate is distributed uniformly,because the bearing pressure is distributed non-uniformly and is concentrated under the column sectio.

Bearing Pressure and Design of Rectangular Steel Tubular Column Baseplate under Concentric Loadings (중심 압축력을 받는 각형강관기둥 베이스플레이트의 지압응력과 설계에 대한 연구)

  • Lee, Seung Joon;Kim, Jeong Hyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.4 s.71
    • /
    • pp.463-470
    • /
    • 2004
  • In this study, the bearing pressure distribution and design method of rectangular steel tubular column base plates under concentric loading were investigated. In general, the size and thickness of the baseplate are determined with the assumption that the bearing pressure of the column baseplate is uniformly distributed. When the column is loaded lightly, however, the size of the baseplate becomes smaller, the thickness becomes thinner and the bearing pressure of the baseplate is not distributed evenly. In this study, the distribution of the bearing pressure was investigated using the experimental and analytical methods. Four test specimens of the rectangular steel column baseplate were fabricated and tested. The analysis of the specimens was done using the finite element analysis program ANSYS. The result was that it was appropriate to use the effective width method to design the lightly loaded column baseplate, because the bearing pressure was not distributed evenly and was only concentrated under the column section.

An analytical study on the structural behavior of H shape column base plates under axial loads and moments (축력과 모멘트를 받는 H형강 주각부의 거동에 관한 해석적 연구)

  • Kim, Jeong Hyun;Lee, Seung Joon
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.2 s.75
    • /
    • pp.217-225
    • /
    • 2005
  • The purpose of this study is to investigate the behavior of H-shape column base plates subjected to axial loads and moments. In this study, the behavior of H-shape column base plates is investigated using finite element analysis method and an analytical modelingof the base plates is obtained. The variations of six test specimens include ratiosof axial load, sizes of anchor bolts, and thicknesses of base plates. The experimental results are compared with the results from the finite element analyses and those of the analytical modeling. Bearing pressures of base plates from the finite element analyses are compared with those that are assumed in the design of the base plates. From the results of the research, it is observed that the initial stiffness and yield strengths in the analytical study are very similar to the experimental results. And bearing pressures are concentrated under column section with thin base plates.

A Study on the Structural Behavior of Eccentrically Loaded Steel Column Base Plates (편심 축하중을 받는 강구조 주각부의 거동에 관한 연구)

  • Lee, Seung Joon;Song, Hyun Seok
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.323-332
    • /
    • 2008
  • The behavior of eccentrically loaded steel column base plates is investigated experimentally and analytically. A total of 8 test specimens are fabricated and tested. The effects of eccentricity and thickness of baseplate on the behavior of base plates are investigated. Analytical study is performed using the Finite Element Analysis Program ANSYS 8.1 to investigate distribution of bearing pressure. The results from to the distribution of bending strain of the base plate. However, the distribution of the bearing pressure obtained from the analysis is different from that assumed in the current design method. The results from the analysis show that the bearing pressures of the baseplate are concentrated under the compressively stressed column flange, as the eccentricity is increased. Also the results from the analysis are different from the results of design using the existing design method and the design method according to the AISC-Steel Design Guide.

A Case Study on the Occurrence and Solution of Stability problems around Large Underground Storage Cavern in Highly Stressed Rock Mass (과지압 암반내 대규모 지하공동 안정성 문제 및 대책)

  • Lee, Dae-Hyuck;Lee, Hee-Suk;Park, Yeon-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.622-640
    • /
    • 2009
  • 원유 비축기지 저장공동과 같이 상하로 긴 형상의 대규모 공동에서 횡방향의 지압이 과도하게 작용하면 천정부의 응력집중과 측벽의 암반 변위가 과도하게 발생하여 저장공동의 불안정 요인이 된다. 특히 지압의 절대 크기가 암반 강도의 일정 비율 이상이 되면 응력 집중에 의한 암반의 취성 파괴를 유발하고, 이러한 현상은 터널 굴착 시 발생하는 파괴음(popping)과, 굴착면에 평행한 형태로 암편이 탈락하는 취성파괴(spalling) 현상을 동반한다. 이 글에서는 대규모 지하저장공동 굴착시 실제 발생한 과지압으로 인한 문제 사례에 대해 소개한다. 저장공동 굴착시 관찰된 암편 및 숏크리트 탈락과 균열 발생 현상을 관찰하고 암반 계측결과 분석을 통해 과지압의 현상을 진단하였다. 과지압 구간의 현재 상태 및 원안 설계안에 대해 연속체 및 불연속체 안정성 해석을 실시하여 문제의 심각성을 평가하였다. 이를 통해 굴착 형상 변경 및 특수 보강 방안을 제안하였으며 제안된 안의 보강효과에 대한 수치해석 평가 결과를 재검토 하였다. 이들 결과를 종합하여 과지압구간 보강안을 도출하였으며 상시 안정성 감시 대책으로 현장 암반의 미소파괴음 계측 방안을 제시하였다.

  • PDF

Shear Strength of SFRC Deep Beam with High Strength Headed Reinforcing Tensile Bars (고강도 확대머리 인장철근을 가지는 SFRC 깊은 보의 전단강도)

  • Kim, Young-Rok;Lee, Chang-Yong;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.5
    • /
    • pp.111-117
    • /
    • 2019
  • Shear experiments were carried out to evaluate shear performance of SFRC deep beams with end-anchorage of SD600 high strength headed reinforcing tensile bars. The experimental variables include the end-anchorage methods of tensile bars (headed bar, straight bar), the end-anchorage lengths, and the presence of shear reinforcement. Specimens with a shear span ratio of 1 showed a pattern of the shear compression failure with the slope cracks progressed after the initial bending crack occurred. Specimens with end-anchorage of headed bars (H-specimens) showed a larger shear strengths of 5.6% to 22.4% compared to straight bars (NH-specimens). For H-specimens, bearing stress reached 0.9 to 17.2% of the total stress of tensile bars up to 75% of the maximum load, and reached 22.4% to 46%. This shows that the anchorage strength due to the bearing stress of headed bars has a significant effect on shear strength. The experimental shear strength was 2.68 to 4.65 times the theoretical shear strength by the practical method, and the practical method was evaluated as the safety side.

A Study on the Design of Special Circular Plate Anchorage for Post-tension (원형 정착판을 사용한 포스트텐션 특수정착구의 설계에 관한 연구)

  • Choi, Kyu-Hyung;Lho, Byeong-Cheol;Lim, Jung-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.6
    • /
    • pp.73-83
    • /
    • 2016
  • Bearing stress near anchor plates is usually very high due to prestressing force in anchorage zone of concrete structure used post-tensioned prestressed method. In order to effective utilization of cross section and crack control, appropriate size of anchorage plates should be used to prevent crack initiation and failure of concrete structures eventually. This study aims to suggest equation for effective area of bearing plate of rectangle type and circular type by Highway Bridge Design Specification and PTI etc. A shape factor according to bearing plate shape is suggested based on numerical analysis, and it can be used suitability for design of special anchorage plate dimension.

Structural Analysis of Concrete-filled FRP Tube Dowel Bar for Jointed Concrete Pavements (콘크리트 포장에서 FRP 튜브 다웰바의 역학적 특성 분석)

  • Park, Jun-Young;Lee, Jae-Hoon;Sohn, Dueck-Su
    • International Journal of Highway Engineering
    • /
    • v.13 no.3
    • /
    • pp.21-30
    • /
    • 2011
  • As well known, dowel bars are used to transfer traffic load acting on one edge to another edge of concrete slab in concrete pavement system. The dowel bars widely used in South Korea are round shape steel bar and they shows satisfactory performance under bending stress which is developed by repetitive traffic loading and environment loading. However, they are not invulnerable to erosion that may be caused by moisture from masonry joint or bottom of the pavement system. Especially, the erosion could rapidly progress with saline to prevent frost of snow in winter time. The problem under this circumstance is that the erosion not only drops strength of the steel dower bar but also comes with volume expansion of the steel dowel bar which can reduce load transferring efficiency of the steel dowel bar. To avoid this erosion problem in reasonable expenses, dowers bars with various materials are being developed. Fiber reinforced plastic(FRP) dower that is presented in this paper is suggested as an alternative of the steel dowel bar and it shows competitive resistance against erosion and tensile stress. The FRP dowel bar is developed in tube shape and is filled with high strength no shrinkage. Several slab thickness designs with the FRP dowel bars are performed by evaluating bearing stress between the dowel bar and concrete slab. To calculated the bearing stresses, theoretical formulation and finite element method(FEM) are utilized with material properties measured from laboratory tests. The results show that both FRP tube dowel bars with diameters of 32mm and 40mm satisfy bearing stress requirement for dowel bars. Also, with consideration that lean concrete is typical material to support concrete slab in South Korea, which means low load transfer efficiency and, therefore, low bearing stress, the FRP tube dowel bar can be used as a replacement of round shape steel bar.

Mechanical Stability Analysis of a High-Level Waste Repository for Determining Optimum Cavern and Deposition Hole Spacing (고준위폐기물 처분장의 최적 공동간격 및 처분공간격을 결정하기 위한 역학적 안정성 해석)

  • 박병윤;권상기
    • Tunnel and Underground Space
    • /
    • v.10 no.2
    • /
    • pp.237-248
    • /
    • 2000
  • Based on the preliminary results from the therm analysis, which is currently carrying, three-dimensional computer simulations using a finite element code, ABAQUS Ver. 5.8, were designed to determine the mechanically stable cavern and deposition hole spacing. Linear elastic modeling for the cases with different cavern and deposition hole spacing were carried out under three different in situ stress conditions. From the simulations, the response of the rock to the stress redistribution after the excavation of the openings could be investigated. Also the optimum cavern and deposition hole spacing could be estimated based on the factor of safety. When the in situ stress determined from the actual stress measurements in Korea were used, the case with cavern spacing of 40m and deposition hole spacing of 3m was in very stable condition, because the factor of safety was calculated as 3.42., When the in situ stress conditions for Sweden and Canada were used, the previous case, they seem to be in stable condition, since the factors of safety are still higher than 1.0. From these results, it was concluded that the rock will not fail even after the stress redistribution.

  • PDF

Bearing Strength of Steel Baseplate under Eccentric Loads (편심축력(偏心軸力)을 받는 철골구조(鐵骨構造) 주각부(柱脚部)의 지압강도(支壓强度))

  • Choi, Mun Sik;Min, Byung Yeol
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.6 s.67
    • /
    • pp.683-691
    • /
    • 2003
  • Recently, the steel has been increaseingly used as an integrated part of high-rise buildings, which often composed of steel structures, steel reinforced concrete structures and composite structures. The steel base is designed to transfer the stresses induced from steel column to the reinforced concrete footing through the base plate. However, in the design of steel structures and steel reinforced concrete structure, it is generally difficult to evaluate the bearing strength of the steel base subjected to large axial force. Furthermore, the material used in steel base is quite different from those used in other connections and a load transferring mechanism of steel base is very complicated in nature. Therefore, a special attention must be placed in design and construction of steel base. In generally, the bearing strength test and research of the steel base subjected to concentrated load are carried out. But, in the design of the structures, uniaxial eccentric load is loaded to the steel base of the steel structures. In this research, the bearing strength and the me of failure considering eccentric loads and eccentric length, were experimented when eccentric load is loaded to the steel base of steel structures. Based on the test results, a basic design reference is suggested for a reasonable design of steel structures, steel reinforced concrete structures and composite structures.