• Title/Summary/Keyword: 지붕형 태양광

Search Result 20, Processing Time 0.024 seconds

A Study on Optimizing of Roof-Top Photovoltaic Arrays Arrangement Based on Three-Dimensional Geo-Spatial Information (3차원 지형공간정보 기반 지붕형 태양광 어레이 배치 최적화 연구)

  • Kim, Se-Jong;Koo, Kyo-Jin
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.6
    • /
    • pp.151-159
    • /
    • 2011
  • Due to the Korean government's renewable energy support policy such as the renewable energy utilization building certificate and enlarging the compulsory ratio of investment on the public building, the rooftop photovoltaic projects are expanding rapidly. It is very important for the rooftop photovoltaic projects to analyze the shading effect of the adjacent structures or own facilities. But, the photovoltaic arrangements are planned by the experience of the designers or simple graphic tools. The purpose of this study is to build the process model for optimizing of rooftop photovoltaic arrangement based on three-dimensional geo-spatial information.

The Effect of Urban Trees on Residential Solar Energy Potential (도심 수목이 분산형 주거 태양광에너지 잠재량에 미치는 영향)

  • Ko, Yekang
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.1
    • /
    • pp.41-49
    • /
    • 2014
  • This study spatially assesses the impact of trees on residential rooftop solar energy potential using urban three-dimensional models derived from Light Detection and Ranging(LiDAR) data in San Francisco, California. In recent years on-site solar energy generation in cities has become an essential agenda in municipal climate action plans. However, it can be limited by neighboring environments such as shade from topography, buildings and trees. Of all these effects, the impact of trees on rooftop photovoltaics(PVs) requires careful attention because improper situation of solar panels without considering trees can result in inefficient solar energy generation, tree removal, and/or increasing building energy demand and urban heat island effect. Using ArcMap 9.3.1, we calculated the incoming annual solar radiation on individual rooftops in San Francisco and the reduced insolation affected by trees. Furthermore, we performed a multiple regression analysis to see what attributes of trees in a neighborhood(tree density, tree heights, and the variance of tree heights) affect rooftop insolation. The result shows that annual total residential rooftops insolation in San Francisco is 18,326,671 MWh and annual total light-loss reduction caused by trees is 326,406 MWh, which is about 1.78%. The annual insolation shows a wide range of values from $34.4kWh/m^2/year$ to $1,348.4kWh/m^2/year$. The result spatially maps the locations that show the various levels of impact from trees. The result from multiple regression shows that tree density, average tree heights and the variation of tree heights in a neighborhood have statistically significant effects on the rooftop solar potential. The results can be linked to municipal energy planning in order to manage potential conflicts as cities with low to medium population density begin implementing on-site solar energy generation. Rooftop solar energy generation makes the best contribution towards achieving sustainability when PVs are optimally located while pursuing the preservation of urban trees.

A Study on Automatic Solar Tracking Design of Rooftop Solar Power Generation System and Linkage with Education Curriculum (지붕 설치형 태양광 발전 시스템의 태양 위치 추적 구조물 설계 및 설치 실증 기법의 교육과정 연계)

  • Woo, Deok Gun;Seo, Choon Won;Lee, Hyo-Jai
    • Journal of Practical Engineering Education
    • /
    • v.14 no.2
    • /
    • pp.387-392
    • /
    • 2022
  • To participate in global carbon neutrality, the Korean government is also planning to carry out zero-energy building certification for all buildings by 2030 through the enforcement decree of the 'Green Building Support Act'. Accordingly, the government is providing various projects related to solar power generation, which are relatively close to life. In particular, roof-mounted photovoltaic power generation systems are attracting attention in terms of using unused space to produce energy without destroying the environment, but low power generation efficiency compared to other photovoltaic power generation facilities is pointed out as a disadvantage. Therefore, in this paper, to solve this problem, we propose an efficient solar panel angle variable system through research on the solar panel structure for single-axial solar tracking, and also consider the application environment of the roof-mounted solar power generation system. Suggests measures to prevent damage and secondary damage. In addition, it is judged that it is possible to control the solar panel based on ICT convergence and configure the accident prediction safety system to link the project-based education program.

Photovoltaic Panel Orientation Study for Tube-Enclosed Transportation Systems (튜브형 초고속 이동수단을 위한 태양광 시스템 연구)

  • Kwon, Kyoungjun;Kim, Katherine Ann
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.50-51
    • /
    • 2017
  • 최근 전 세계적으로 차세대 초고속 교통수단의 연구, 개발에 박차를 가하고 있다. 대표적으로 미국에서 개발하고 있는 하이퍼루프는 승객을 태운 차체가 원통형인 튜브안에서 최대 1200 km/h로 이동하는 초고속 교통수단이다. 이렇게 빠른 속도에 도달하기 위해서 수십 MW 수준의 상당히 큰 전력이 필요하며, 이러한 큰 전력소모에 의한 전력망의 부담을 덜기 위해, 태양광 시스템을 튜브에 장착하여 추진에 필요한 일부 전력을 태양광 발전으로 대체하는 시스템이 연구되고 있다. 본 논문에서는 튜브의 방향, 태양전지의 배열에 따른 에너지 생산량, 전력발전량 및 비용 등의 다각적인 측면에서의 분석을 제시하였다. 원통형 튜브에 부착되는 태양전의 배열을 여섯 가지 경우로 나누었을 때, 삼각 지붕 모양으로 태양전지를 배열한 Case 2가 가장 높은 에너지 생산량을 보였다. 하지만 태양전지의 단위면적 당 에너지 생산량을 비용으로 계산하였을 경우, 튜브 위에 평평하게 태양전지를 배열한 Case 1이 가장 높은 가격 경쟁력을 가졌다.

  • PDF

Analysis of Shadows Effect in Seoul Area for the Estimation of Roof-type PV Power Calculation (지붕형 태양광 발전량 산정을 위한 서울지역 그림자 효과 분석)

  • Yun, ChangYeol;Jung, BoRin;Kim, ShinYoung;Kim, ChangKi;Kim, JinYoung;Kim, HyunGoo;Kang, YongHeack;Kim, YongIl
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.2
    • /
    • pp.45-53
    • /
    • 2018
  • For the preliminary step for estimating the performance of roof-type photovoltaic system in urban areas, we analyzed the solar radiation reduction ratio by shadow effect by buildings using DSM (Digital Surface Model) and GIS (Geographical Information System) tools. An average loss by the shadow is about 19% in Seoul. The result was related to the building density and distribution. Monthly results show that the winter season (December and January) was more affected by the shading than during the summer season (June and July). It is expected that useful empirical formulas can be made if more detailed correlation studies are performed.

A Study of Cooling and Heating Load Changes with Roof Type Solar Panels Installed on Factory Roof (지붕형 태양광발전 패널의 공장 지붕 설치에 따른 냉방 및 난방 부하 변화량 연구)

  • Jo, Ho-Hyeon;Kim, Jung-Min;Kim, Young Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.4
    • /
    • pp.9-15
    • /
    • 2020
  • In this study, effect of reinforced insulation on heating and cooling loads were studied due to installation of PV panels on factory building roof with a floor area of 12,960 m2. For PV panel installation, combination of aluminum, polyurethane, air, polystyrene and steel materials were added to the original roof, which increased thermal insulation performance. Half of the roof were covered with PV panel and the other half without. Temperature and relative humidity were measured for 8 days during summer season for both indoor spaces. PV panel showed the effect of lowering the indoor space temperature by 0.6℃. TRNSYS dynamic simulation showed that with PV panel, cooling load per area is reduced by 1.7 W/m2 and heating by 10.0 W/m2. PV panels installed on building roof not only generate electricity but also can save energy by reducing cooling and heating loads.

A study on the Application of Roof Integrated Photovoltaic System - Focused on the Optimal Length Ratio Calculation of System - (지붕 일체형 태양광 발전 시스템의 응용에 관한 연구 - 시스템의 최적길이비 산정을 중심으로 -)

  • Kim, Eui-Jong;Choi, Won-Ki;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.2
    • /
    • pp.27-33
    • /
    • 2005
  • To improve the performance of the top-positioning space in buildings, we suggested the environment-friendly system integrating various design techniques in the previous paper. This work discussed to calculate the length of PV considering a part of metallic radiators for radiative cooling, an critical element of the whole system, for shading not to prevent the PV on roof from generating electricity. In the process of calculating the shading area, we used the geometrical relationship between the sun-rays and the variable roof. For general applications, we utilized DL, the ratio of the length of PV and that of metallic radiator on roof, as a design factor, and then used the maximum insolation and the specific insolation($200W/m^2$) to decide the distance off the axis of rotation. As a result, for DL, we found out the reasonable value of 1.0 with full covering, 1.2 with 90%, and 2.0 with 70% in PV covering.

Classification of Rail System in Steel Structure Stadiums by Case Study (사례분석에 의한 강구조 스타디움 레일 시스템 분류)

  • Kim, Hye-Seong;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.1
    • /
    • pp.67-74
    • /
    • 2010
  • This paper focuses on steel arrays regarding the application of PV system for solar power system, a renewable energy in steel structure stadium that will be built in Korea, by foreign case study. 20 cases of Steel Structure Stadiums applying PV system after 1990 were selected as the main subjects. The 20 cases of Steel Structure Stadiums were categorized by rail systems that were installed to fix PV module. As the result, linear clamping and roof-integrated type among cross rails were 28% of the whole, followed by 17% of rail-fixed type and 11% of module group-fixed type among vertical-fixed types. In addition, linear clamping and roof-integrated type among cross rails were applied in the inside of the stadium while the outside and other parts of stadiums used angle bracket to fix PV module.

  • PDF

Operation System Design of Distribution Feeder with Distributed Energy Resources (분산전원이 연계된 배전선로의 운영시스템 설계)

  • Kim, Seong-Man;Chang, Young-Hak;Kim, Kyeong-Hun;Kim, Sul-Ki;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1183-1194
    • /
    • 2021
  • Traditionally, electric power systems have been known as the centralized structures, which is organized into placing customers at the end of the supply chain. However, recent decades have witnessed the emergence of distributed energy resources(:DERs) such as rooftop solar, farming PV system, small wind turbines, battery energy storage systems and smart home appliances. With the emergence of distributed energy resources, the role of distributed system operators(:DSOs) will expand. The increasing penetration of DERs could lead to a less predictable and reverse flow of power in the system, which can affect the traditional planning and operation of distribution and transmission networks. This raises the need for a change in the role of the DSOs that have conventionally planned, maintained and managed networks and supply outages. The objective of this research is to designed the future distribution operation system with multi-DERs and the proposed distribution system model is implemented by hardware-in-the-loop simulation(HILS). The test results show the normal operation domain and reduction of distribution line loss.

Roof-attached Crystalline Silicon Photovoltaic Module's Thermal Characteristics (지붕 설치형 결정질 실리콘 태양전지모듈의 온도 특성)

  • Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong;Yoon, Soon-Gil
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.11-18
    • /
    • 2012
  • To expect accurately the maximum power of solar cell module under various installation conditions, it is required to know the performance characteristics like temperature dependence. Today, the PV (photovoltaic) market in Korea has been growing. Also BIPV (building integrated photovoltaic) systems are diversified and become popular. But thermal dependence of PV module is little known to customers and system installers. In IEC 61215,a regulation for testing the crystalline silicon solar cell module, the testing method is specified for modules. However there is limitation for testing the module with diverse application examples. In extreme installation method, there is no air flow between rear side of module and ambient, and it can induce temperature increase. In this paper, we studied the roof type installation of PV module on the surface of one-axis tracker system. We measured temperature on every component of PV module and compared to open-rack structure. As a result, we provide the foundation that explains temperature characteristics and NOCT (nominal operation cell temperature) difference. The detail description will be specified as the following paper.