• Title/Summary/Keyword: 중앙감시시스템

Search Result 120, Processing Time 0.029 seconds

A Study on the Energy Saving Method by controlling Capacity of Sea Water Pump in Central Cooling System for Vessel (선박용 중앙냉각시스템의 해수 펌프 용량조절에 따른 에너지 절감 기법에 관한 연구)

  • Lee, Ji-Young;Yoo, Heui-Han;Kim, Yun-Hyung;Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.592-598
    • /
    • 2007
  • The fuel charge is getting higher in navigation cost. Therefore, shipowners try to find the method for reducing oil consumption. ESS(Energy Saving System) is one of he method. ESS is the system consisted with two inverters, ESS control unit and monitoring system. Two inverters control two main sea water cooling pumps. In the ESS control Unit, the control algorithm finds optimized point to decrease a power consumption of main sea water cooling pumps. Monitoring system observes ESS not to work improperly. ESS is experimented in the laboratory with real condition and analyzed in every view. After experiment, the result of the experiment shows that the control algorithm works correctly and safely. ESS has a plan to be operated in the ship soon. In that case, additional devices are needed to connect ESS with cooling system of the vessel. So the development of addition device is needed and being studied.

내장형 무선 카메라를 이용한 ICP 보조 스퍼터링 장치의 실시간 모니터링

  • Choe, Ji-Seong;Hong, Gwang-Gi;Yang, Won-Gyun;Jeon, Yeong-Saeng;Ju, Jeong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.476-476
    • /
    • 2010
  • 유도 결합 플라즈마 (ICP)는 축전 결합 플라즈마 (CCP) 보다 상대적으로 높은 밀도의 플라즈마를 발생시킬 수 있다. 또한 구조가 간단하고 기존 스퍼터링 장치의 내부에 추가 설치가 용이하며, 스퍼터된 입자의 이온화, 반응성 가스의 활성화를 위한 2차 플라즈마원으로 적용이 가능하다. 그러나 대면적의 고밀도 플라즈마의 균일도 측정은 고가의 2D probe array등을 사용하여야 한다. 본 연구에서는 간단한 CCD camera를 챔버 내부에 삽입하여 가시광 영역의 적분 강도를 이용해서 플라즈마의 2차원적 균일도를 정성적으로 비교 판단하고 시간에 따른 국부적인 이상 방전을 감시할 수 있도록 내장형 무선 카메라를 사용하였다. 직경 380 mm의 챔버 내에 2 turn ICP antenna를 이용하여 유도 결합 플라즈마를 발생시켰다(Ar 30 sccm, 35 mTorr, 2 MHz, 400 W). 내장형 무선 카메라를 챔버 내부 중앙의 ICP antenna에서 8 cm 아래에 위치시켜 플라즈마를 진공 중에서 촬영하였다. 내장형 무선 카메라를 챔버 내부에 위치하여 촬영한 결과 외부에서 view port로 쉽게 확인할 수 없는 ICP antenna 내부의 고밀도 플라즈마의 불균일도를 평가할 수 있었고, ICP antenna 가장자리에서 중심으로 이동할수록 밝아지는 것을 토대로 중심 영역의 plasma 밀도가 가장 높다는 것을 알 수 있었고, 채도와 명도의 차이를 이용하여 시각적인 플라즈마 균일도를 분석하였으며 이를 플라즈마 모델링 기능이 있는 전산 유체 역학 프로그램인 CFD ACE+를 이용하여 플라즈마 분포를 모델링 및 비교하였다. 또한 인라인 타입의 마그네트론 스퍼터링 시스템에서 기판 캐리어에 무선 카메라를 장착하여 이동하면서 캐리어와 마그네트론 방전 공간의 상대적인 위치에 따른 마그네트론 방전링의 형상 변화도 관찰하였다.

  • PDF

Availability Performance Analysis of Korean Wide Area Differential GNSS Test Bed (한국형 광역보정시스템 테스트베드 가용성 성능 분석)

  • Yun, Ho;Kee, Chang-Don;Kim, Do-Yoon
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.4
    • /
    • pp.510-516
    • /
    • 2011
  • For using Global Navigation Satellite System(GNSS) in the civil aviation, it should satisfies the Required Navigation Performances(RNPs) which are defined by International Civil Aviation Organization(ICAO). RNP defines the required accuracy, integrity, availability, continuity of each flight procedure. In order to guarantee user's integrity, user's protection level has to be overestimated. On the other hand, for improving user's availability, user's protection level has to be estimated tightly. Therefore protection level should be estimated as tight as possible while it assuring the user's integrity. This paper describes the current integrity function of Korean WAD GNSS test bed, and predicts the availability performance of Korean WAD GNSS by simulation.

A Study on System Tracing User Activities in the Windows Operating System (윈도우 운영체제 상의 사용자 행위 추적에 관한 연구)

  • Jung, Chang-Sung;Kim, Young-Chan
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.21 no.4
    • /
    • pp.101-114
    • /
    • 2011
  • As it seems like critical information leakages have been increasing due to industrial espionage and malicious internal users, the importance of introducing audit and log security technology is growing every now and then. In this paper, we suggest the session logging system for the company's internal control to meet the SOX legislation level, by monitoring and analyzing users behaviors connecting to the business-critical Operating System. The system proposed in this paper aims to monitor the user's illegal activities in the Operating System, and to present the clear evidence of purpose of those activities by detailed logs. For this purpose, we modified Operating System by adding multiple services suggested in this paper. These services utilize interfaces provided by the existing Operating System and add functions to control access and get logs. The system saves and manages session logs of users or administrators connected to the server with centralized log storage. And the system supports session log searching and lookup features required by SOX legislation for the company's internal controls with the level of computer forensics and logging technology.

Energy Efficient Distributed Intrusion Detection Architecture using mHEED on Sensor Networks (센서 네트워크에서 mHEED를 이용한 에너지 효율적인 분산 침입탐지 구조)

  • Kim, Mi-Hui;Kim, Ji-Sun;Chae, Ki-Joon
    • The KIPS Transactions:PartC
    • /
    • v.16C no.2
    • /
    • pp.151-164
    • /
    • 2009
  • The importance of sensor networks as a base of ubiquitous computing realization is being highlighted, and espicially the security is recognized as an important research isuue, because of their characteristics.Several efforts are underway to provide security services in sensor networks, but most of them are preventive approaches based on cryptography. However, sensor nodes are extremely vulnerable to capture or key compromise. To ensure the security of the network, it is critical to develop security Intrusion Detection System (IDS) that can survive malicious attacks from "insiders" who have access to keying materials or the full control of some nodes, taking their charateristics into consideration. In this perper, we design a distributed and adaptive IDS architecture on sensor networks, respecting both of energy efficiency and IDS efficiency. Utilizing a modified HEED algorithm, a clustering algorithm, distributed IDS nodes (dIDS) are selected according to node's residual energy and degree. Then the monitoring results of dIDSswith detection codes are transferred to dIDSs in next round, in order to perform consecutive and integrated IDS process and urgent report are sent through high priority messages. With the simulation we show that the superiorities of our architecture in the the efficiency, overhead, and detection capability view, in comparison with a recent existent research, adaptive IDS.

Development of a Prototype Patient Monitoring System with Module-Based Bedside Units and Central Stations: Overall Architecture and Specifications (모듈형 환자감시기와 중앙 환자감시기로 구성되는 환자감시시스템 시제품의 개발: 전체구조 및 사양)

  • Woo, E.J.;Park, S.H.;Jun, B.M.;Moon, C.W.;Lee, H.C.;Kim, S.T.;Kim, H.J.;Seo, J.J.;Chae, K.M.;Park, J.C.;Choi, K.H.;Lee, W.J.;Kim, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.315-319
    • /
    • 1996
  • We have developed a prototype patient monitoring system including module-based bedside units, interbed network, and central stations. A bedside unit consists of a color monitor and a main CPU unit with peripherals including a module controller. It can also include up to 3 module cases and 21 different modules. In addition to the 3-channel recorder module, six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmogaph are provided as parameter modules. Modules and a module controller communicate with up to 1Mbps data rate through an intrabed network based on RS-485 and HDLC protocol. Bedside units can display up to 12 channels of waveforms with any related numeric informations simultaneously. At the same time, it communicates with other bedside units and central stations through interbed network based on 10Mbps Ethernet and TCP/IP protocol. Software far bedside units and central stations fully utilizes gaphical user interface techniques and all functions are controlled by a rotate/push button on bedside unit and a mouse on central station. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances. In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we are developing a relational database server dedicated to the patient monitoring system. We are also developing a clinical workstation with which physicians can review and examine the data from patients through various kinds of computer networks far diagnosis and report generation. Portable bedside units with LCD display and wired or wireless data communication capability will be developed in the near future. New parameter modules including cardiac output, capnograph, and other gas analysis functions will be added.

  • PDF

Improvement Research of BLE-based System for Monitoring the cause of Breakdown of Automatic Doors (자동문의 고장원인을 모니터링하기 위한 BLE 기반의 시스템 개선연구)

  • Kim, Gi-Doo;Won, Seo-Yeon;Kim, Hie-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.93-102
    • /
    • 2017
  • Recently increasing usage of smartphones makes the Internet of Things (IoT) a leading technology that can collect and share data through sensor networks and wireless communication such as low-power Bluetooth (BLE). BLE-based application can provide operators more precise information on Automatic Door system by remotely diagnosing the system faults through wireless sensor networks and sensors around the Automatic Door. In this paper, a smart device with extended BLE module is implemented which can monitor and Control the system states and faults remotely without on-site diagnostic. while maintaining system integrity so that increase efficiency of time and costs for system management. We can use the results of this research as a basis in evaluating reliability of data between devices, extending communication module in Controller of obsolete Door systems, and establishing centralized monitoring systems in near future with multi-channel Door Controls.

A Study on the Network Architecture for KEPCO SCADA Systems (한국전력 스카다 시스템의 네트워크 구조에 대한 연구)

  • Ryo, Woon Jong
    • Industry Promotion Research
    • /
    • v.2 no.2
    • /
    • pp.1-6
    • /
    • 2017
  • SCADA (Supervisory Control and Data Acquisition) System was first introduced to the Seoul Electricity Authority, which manages the transportation part among the three business fields that produce, transport and supply electric power in Korea. Has been using the data link with 1200 bps and 9600 bps in 5 protocols such as HARRIS 6000, BSC, HDLC, L & N and Toshiba by configuring 3 layers of EMS, SCADA and RTU computer equipments in 1: N radial form. This paper presents the OSI standard network packet flow, analyzing DataLink and Network Layer, and presents a KEPCO SCADA network model composed of X.25 high - speed communication network using 3 layers of network. We proposed a future SCADA communication structure that improved the current SCADA communication structure, defined the SCADA DB structure, introduced the concept of the remote SCADA gateway to the SCADA functional structure, applied the standard communication protocol, Multiplexing of surveillance and control in other local facilities and ensuring communication openness.

Intelligence e-Learning System Supporting Participation of Students based on Face Recognition (학습자 참여를 유도하기 위한 얼굴인식 기반 지능형 e-Learning 시스템)

  • Bae, Kyoung-Yul;Joung, Jin-Oo;Min, Seung-Wook
    • Journal of Intelligence and Information Systems
    • /
    • v.13 no.2
    • /
    • pp.43-53
    • /
    • 2007
  • e-Learning education system as the next educational trend supporting remote and multimedia education. However, the students stay mainly at remote place and it is hard to certificate whether he is really studying now or not. To solve this problem, some solutions were proposed such as instructor's supervision by real time motion picture or message exchanging. Unhappily, as you can see, it needs much cost to establish the motion exchanging system and trampling upon human rights could occasion to reduce the student's will. Accordingly, we propose the new intelligent system based on face recognition to reduce the system cost. The e-Learning system running on the web page can check the student's status by motion image, and the images transfer to the instructor. For this study, 20 students and one instructor takes part in capturing and recognizing the face images. And the result produces the prevention the leave of students from lecture and improvement of attention.

  • PDF

Design and Implementation of a Power-Saving Management System using Intelligent Scheduler based on RFID/USN Technology (RFID/USN 기술 기반의 지능형 스케줄러를 이용한 절전관리 시스템 설계 및 구현)

  • Jeong, Kyu-Seuck;Choi, Sung-Chul;Jeong, Woo-Jeong;Kim, Tae-Ho;Kim, Jong-Heon;Seo, Dong-Min;Park, Yong-Hun;Yoo, Jae-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.64-76
    • /
    • 2009
  • Recently, the ubiquitous environment and the practical technology associated with it become more popular topic along with the rapid development of wireless technologies. The necessity of the automated system based on the ubiquitous environment has been increasing when the concept of the ubiquitous is integrated into the fields of existing IT. Also, the necessity of formulating a power-saving plan on large buildings and public institutions is gathering strength because of a raise in exchange rates and high oil prices. In this paper, to efficiently manage the power consumption of the electronic machine such as electric lights, electric heaters, and air conditioners in a building, power-saving manage- ment system using RFID/USN technologies is proposed. Proposed system controls the electric machine and monitor it's condition by RFID and collects the real time information about the surrounding and the power consumption of the electric machine by USN. Especially, proposed system analyzes the real time information and supports the intelligent scheduler with the best power-saving. Finally, this paper shows the difference between proposed system and existing system and establishes thereality of our system through experiments in variety environments.