• Title/Summary/Keyword: 중심보정

Search Result 493, Processing Time 0.031 seconds

Analysis for the RCS of a Trihedral Corner Reflector with Consideration of the Effect of Front Surface (지표면 영향을 고려한 삼각 전파 반사기의 RCS 분석)

  • Shin, Jong-Chul;Kweon, Soon-Koo;Oh, Yi-Sok;Kim, Se-Young;Jeon, Byeong-Tae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.6
    • /
    • pp.723-730
    • /
    • 2012
  • The radar cross section(RCS) of a trihedral corner reflector(TCR) should be accurately computed when it is used as an external calibration target for a satellite synthetic aperture radar(SAR) calibration campaign. This paper presents the RCS analysis on a trihedral corner reflector which is installed on a calibration site, using the wave reflection from the rough surface and the wave diffraction from the TCR edges. The results in this paper show quantitatively the effect of the front surface on the RCS of a TCR. The difference of the RCS between a TCR in air and a TCR on a ground surface is computed by including the interaction term which consists of the edge diffraction from the TCR edges and the surface reflection from the front rough surface. The reflection coefficient of a randomly rough surface is a function of the surface roughness and dielectric constant of the surface. The RCS of $10{\lambda}$ size TCR on a ground is 0.46 dB higher than TCR in air at 9.65 GHz, and this can reach at maximum 1.55 dB depending on a surface condition and TCR size. The effect of the front surface on the RCS of a TCR increases, as the surface roughness decreases, the soil moisture increases, and the size of TCR in wavelength decreases.

Selective Skin Tone Reproduction using Preferred Skin Colors (선호 피부색을 사용한 선택적인 피부색 재현 기법)

  • Kim, Dae-Chul;Kyung, Wang-Jun;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.4
    • /
    • pp.10-15
    • /
    • 2012
  • In a color image, people and especially facial patterns are important and interesting visual objects. Thus, effective skin color reproduction is essential, as skin color is a key memory color in color application systems. Previous studies suggested skin color reproduction by mapping only to the center value of preferred skin region. However, it is not suitable to determine one preference color because preference color from the observer's preference test is not dominant. In this paper, skin color reproduction using multiple preferred skin colors for each race is proposed. The proposed method first defines multiple preferred skin colors for each race according to their luminance level. After that, skin region is detected in an image. The race is then selected by calculating distance between average chromaticity of detected region and that of each racial skin from a database to assign preferred skin color for each race. Next, each corresponding preferred skin color is determined for each selected race. Finally, input skin color is proportionally mapped toward preferred skin color according to the difference between the input skin color and the preferred skin color for a smoothly reproduced skin color. In the experimental results, the proposed method gives better color correction on the objective and subjective evaluation than the previous methods.

The Imbalance Compensation in CMG ('제어모멘트자이로'의 질량불균형 보정)

  • Lee, Jong-Kuk;Song, Tae-Seong;Kang, Jeong-Min;Song, Deok-Ki;Kwon, Jun-Beom;Seo, Joong-Bo;Oh, Hwa-Suk;Cheon, Dong-Ik;Hong, Young-Gon;Lee, Jun-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.11
    • /
    • pp.861-871
    • /
    • 2020
  • Raising the speed of the momentum wheel in the CMG increases the unintended force and torque caused by mass imbalance. This unintended force and torque should be minimized to get the better quality of satellite SAR image because they lead to the vibration of the output image. This paper shows the works on compensating the static imbalance and couple mass imbalance in the CMG wheel. First, the force and torque at the center of mass generated by the mass imbalance were predicted through M&S analysis. Second, the force and torque were estimated similarly through the M&S analysis when the measurement point was moved from the rotation center. Third, the measurement configuration for the force and torque by the mass imbalance was described. Fourth, the change of the force and torque by adding the specified mass to the momentum wheel was observed after comparing the measurements with the results of the M&S. And finally, the effect of the compensation was analyzed by comparing the force and torque before and after the correction while 24Nm class CMG was running in the standby mode.

A Fuzzy Clustering Algorithm for Clustering Categorical Data (범주형 데이터의 분류를 위한 퍼지 군집화 기법)

  • Kim, Dae-Won;Lee, Kwang-H.
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.13 no.6
    • /
    • pp.661-666
    • /
    • 2003
  • In this paper, the conventional k-modes and fuzzy k-modes algorithms for clustering categorical data is extended by representing the clusters of categorical data with fuzzy centroids instead of the hard-type centroids used in the original algorithm. The hard-type centroids of the traditional algorithms had difficulties in dealing with ambiguous boundary data, which might be misclassified and lead to thelocal optima. Use of fuzzy centroids makes it possible to fully exploit the power of fuzzy sets in representing the uncertainty in the classification of categorical data. The distance measure between data and fuzzy centroids is more precise and effective than those of the k-modes and fuzzy k-modes. To test the proposed approach, the proposed algorithm and two conventional algorithms were used to cluster three categorical data sets. The proposed method was found to give markedly better clustering results.

The Correction Factor of Sensitivity in Gamma Camera - Based on Whole Body Bone Scan Image - (감마카메라의 Sensitivity 보정 Factor에 관한 연구 - 전신 뼈 영상을 중심으로 -)

  • Jung, Eun-Mi;Jung, Woo-Young;Ryu, Jae-Kwang;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.208-213
    • /
    • 2008
  • Purpose: Generally a whole body bone scan has been known as one of the most frequently executed exams in the nuclear medicine fields. Asan medical center, usually use various gamma camera systems - manufactured by PHILIPS (PRECEDENCE, BRIGHTVIEW), SIEMENS (ECAM, ECAM signature, ECAM plus, SYMBIA T2), GE (INFINIA) - to execute whole body scan. But, as we know, each camera's sensitivity is not same so it is hard to consistent diagnosis of patients. So our purpose is when we execute whole body bone scans, we exclude uncontrollable factors and try to correct controllable factors such as inherent sensitivity of gamma camera. In this study, we're going to measure each gamma camera's sensitivity and study about reasonable correction factors of whole body bone scan to follow up patient's condition using different gamma cameras. Materials and Methods: We used the $^{99m}Tc$ flood phantom, it recommend by IAEA recommendation based on general counts rate of a whole body scan and measured counts rates by the use of various gamma cameras - PRECEDENCE, BRIGHTVIEW, ECAM, ECAM signature, ECAM plus, IFINIA - in Asan medical center nuclear medicine department. For measuring sensitivity, all gamma camera equipped LEHR collimator (Low Energy High Resolution multi parallel Collimator) and the $^{99m}Tc$ gamma spectrum was adjusted around 15% window level, the photo peak was set to 140-kev and acquirded for 60 sec and 120 sec in all gamma cameras. In order to verify whether can apply calculated correction factors to whole body bone scan or not, we actually conducted the whole body bone scan to 27 patients and we compared it analyzed that results. Results: After experimenting using $^{99m}Tc$ flood phantom, sensitivity of ECAM plus was highest and other sensitivity order of all gamma camera is ECAM signature, SYMBIA T2, ECAM, BRIGHTVIEW, IFINIA, PRECEDENCE. And yield sensitivity correction factor show each gamma camera's relative sensitivity ratio by yielded based on ECAM's sensitivity. (ECAM plus 1.07, ECAM signature 1.05, SYMBIA T2 1.03, ECAM 1.00, BRIGHTVIEW 0.90, INFINIA 0.83, PRECEDENCE 0.72) When analyzing the correction factor yielded by $^{99m}Tc$ experiment and another correction factor yielded by whole body bone scan, it shows statistically insignificant value (p<0.05) in whole body bone scan diagnosis. Conclusion: In diagnosing the bone metastasis of patients undergoing cancer, whole body bone scan has been conducted as follow up tests due to its good points (high sensitivity, non invasive, easily conducted). But as a follow up study, it's hard to perform whole body bone scan continuously using same gamma camera. If we use same gamma camera to patients, we have to consider effectiveness of equipment's change by time elapsed. So we expect that applying sensitivity correction factor to patients who tested whole body bone scan regularly will add consistence in diagnosis of patients.

  • PDF

A Study of the Adjustment and Treatment Depending on the Change of Prostate Location Using DIPS in Proton Beam Therapy for Prostate Gland in which a Fiducial Gold Marker was Inserted (Fiducial Gold Marker가 삽입된 전립선암 양성자 치료 시 Digital Image Positioning System (DIPS)을 이용한 전립선의 위치변화에 따른 보정에 관한 연구)

  • Park, June-Ki;Kim, Sun-Young;Kim, Tae-Yoon;Choi, Kye-Sook;Yeom, Doo-Suk;Kang, Dong-Yoon;Choi, Seung-O;Park, Ji-Youn
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.25-29
    • /
    • 2008
  • Purpose: To monitor the changes of location of prostate gland using DIPS and to examine the adjustment and proton beam therapy depending on the movement of prostate gland in proton beam therapy for prostate gland in which a fiducial gold marker was inserted. Materials and Methods: This study was conducted in ten patients with prostate cancer who received proton beam therapy since April of 2008. To monitor the change of prostate location, three fiducial gold markers were inserted prior to the treatment. To minimize the movement of prostate gland, patients were recommended to urinate prior to the treatment, to intake a certain amount of water and to concomitantly undergo rectal balloon. In these patients, the set-up position was identical to that for a CT-simulation. The PA (posterior-anterior) and lateral images were obtained using both DIPS (digital image positioning system) and a plain radiography, and they were compared between the two imaging modalities. Thus, the changes of the location of fiducial gold marker were assessed based on three coordinates (x, y, z) and then adjusted. This was followed by proton beam therapy. Results: Images which were taken using a plain radiography were compared with those which were taken using DIPS. In ten patients, according to a reference bony marker, the mean changes of the location of fiducial gold marker based on an iso-center were X-axis: $\pm$0.116 cm, Y-axis: $\pm$0.19 cm and Z-axis: $\pm$0.176 cm. These ten patients showed a difference in the changes of location of prostate gland and it ranged between RT: 0.04 cm and RT: 0.24 cm on the X-axis; between Inf: 0.03 cm and Sup: 0.42 cm on the Y-axis; and Post: 0.05 cm and Ant: 0.35 cm on the Z-axis. Conclusion: To minimize the movement of prostate gland, as the pre-treatment prior to the treatment. In all the patients, however, three fiducial gold markers showed a daily variation which were inserted in the prostate gland. Based on the above data, Thus, the requirement of gold marker matching system depending on the daily variation in the proton beam therapy for which more accurate establishment of target was confirmed. It is assumed that an accurate effect of proton beam therapy would be enhanced by adjusting the target-center depending on the location change of prostate gland using DIPS which was used in the current study.

  • PDF

Comparing Calculation Techniques for Effective Rainfalls Using NRCS-CN Method: Focused on Introducing Weighted Average and Slope-based CN (NRCS-CN 방법을 이용한 유효우량 산정기법의 비교분석: 가중평균방법과 경사도 도입을 중심으로)

  • Moon, Geon-Woo;Yoo, Ji-Young;Kim, Tae-Woong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.4
    • /
    • pp.1171-1180
    • /
    • 2014
  • The NRCS-CN method is generally used to estimate effective rainfalls in a basin. However, since the curve number which plays a critical role in the NRCS-CN method was originally developed for US watersheds, it is limited to be directly applied to other basins outside the United States. Therefore various modifications have been suggested to revise the NRCS-CN for specific watershed condition. This study introduced the weighted average method and the slope-based CN to estimate effective rainfalls available for Korean watersheds and compared with the observed direct runoff. The overall results achieved from this study indicated that the adjusted slope-based CN considerably increases effective rainfalls in general and makes the duration of effective storm longer. Based on the statistical error analysis performed for various modifications of NRCS-CN, the weighted average method with the adjusted slope-based CN has highest precision with the observed direct runoff. In addition, after analyzing the relation between the initial loss estimated from rainfall-runoff observations and the potential maximum retention from GIS-based data, it turns out that the assumption of linear relationship between the initial loss and the potential maximum retention is not available for Korean watersheds.

Does Process Quality of Inpatient Care Serve as a Guide to Reduce Potentially Preventable Readmission (PPR)? (의료서비스의 과정적 질과 잠재적으로 예방 가능한 재입원율과의 관계)

  • Choi, Jae-Young
    • Korea Journal of Hospital Management
    • /
    • v.23 no.1
    • /
    • pp.87-106
    • /
    • 2018
  • Objective: The objective of this study is to examine the association between process quality of inpatient care and risk-adjusted, thirty-day potentially preventable hospital readmission (PPR) rates. Data Sources/Study Setting: This was an observational cross-sectional study of nonfederal acute-care hospitals located in two states California and Florida, discharging Medicare patients with a principal discharge diagnosis of heart failure, acute myocardial infarction, or pneumonia January through December 31, 2007. Data were obtained from the Healthcare Cost and Utilization Project State Inpatient Database of the Agency for Healthcare Research and Quality, Centers for Medicare and Medicaid Services Hospital Compare database, and the American Hospital Association Annual Survey of Hospitals. Study Design: The dependent variable of this study is condition-specific, risk-adjusted, thirty-day potentially preventable hospital readmission (PPR). 3M's PPR software was utilized to determine whether a readmission was potentially preventable. The independent variable of this study is hospital performance for process quality of inpatient care, measured by hospital adherence to recommended processes of care. We used multivariate hierarchical logistic models, clustered by hospitals, to examine the relationship between condition-specific, risk-adjusted, thirty-day PPR rates and process quality of inpatient care, after taking clinical and socio-demographic characteristics of patients and structural and operational characteristics of hospitals into account. Findings: Better performance on the process quality metrics was associated with better patient outcome (i.e., low thirty-day PPR rates) in pneumonia, but not generally in two cardiovascular conditions (i.e., heart failure and acute myocardial infarction). Practical Implication: Adherence to the process quality metrics currently in use by CMS is associated with risk-adjusted, thirty-day PPR rates for patients with pneumonia, but not with cardiovascular conditions. More evidence-based process quality metrics closely linked to 30-day PPR rates, particularly for cardiovascular conditions, need to be developed to serve as a guideline to reduce potentially preventable readmissions.

The Development of Real Time Automatic Patient Position Correction System during the Radiation Therapy Based on CCD: A Feasibility Study (CCD기반의 방사선치료 중 실시간 자동 환자 위치보정 시스템 개발: 타당성 연구)

  • Shin, Dongho;Chung, Kwangzoo;Kim, Meyoung;Son, Jaeman;Yoon, Myonggeun;Lim, Young Kyung;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.191-197
    • /
    • 2013
  • Upon radiation treatment, it is the important factor to monitor the patient's motion during radiation irradiated, since it can determine whether the treatment is successful. Thus, we have developed the system in which the patient's motion is monitored in real time and moving treatment position can be automatically corrected during radiation irradiation. We have developed the patient's position monitoring system in which the patient's position is three dimensionally identified by using two CCD cameras which are orthogonal located around the isocenter. This system uses the image pattern matching technique using a normalized cross-correlation method. We have developed the system in which trigger signal for beam on and off is generated by quantitatively analyzing the changes in a treatment position through delivery of the images taken from CCD cameras to the computer and the motor of moving couch can be controlled. This system was able to automatically correct a patient's position with the resolution of 0.5 mm or less.

Quality Analysis of GCP Chip Using Google Map (Google Map을 이용한 GCP 칩의 품질 분석)

  • Park, Hyeongjun;Son, Jong-Hwan;Shin, Jung-Il;Kweon, Ki-Eok;Kim, Taejung
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_1
    • /
    • pp.907-917
    • /
    • 2019
  • Recently, the demand for high-resolution satellite images increases in many fields such as land monitoring and terrain analysis. Therefore, the need for geometric correction is increasing. As an automatic precision geometric correction method, there is a method of automatically extracting the GCP by matching between the GCP Chip and the satellite image. For automatic precision geometric correction, the success rate of matching GCP Chip and satellite image is important. Therefore, it is important to evaluate the matching performance of the manufactured GCP Chip. In order to evaluate the matching performance of GCP Chips, a total of 3,812 GCP Chips in South Korea were used as experimental data. The GCP Chip matching results of KOMPSAT-3A and Google Map showed similar matching results. Therefore, we determined that Google Map satellite imagery could replace high-resolution satellite imagery. Also, presented a method using center point and error radius of Google Map to reduce the time required to verify matching performance. As a result, it is best to set the optimum error radius to 8.5m. Evaluated the matching performance of GCP Chips in South Korea using Google Maps. And verified matching result using presented method. As a result, the GCP Chip s in South Korea had a matching success rate of about 94%. Also, the main matching failure factors were analyzed by matching failure GCP Chips. As a result, Except for GCP Chips that need to be remanufactured, the remaining GCP Chips can be used for the automatic geometric correction of satellite images.