• Title/Summary/Keyword: 중공단면교각

Search Result 29, Processing Time 0.019 seconds

Seismic Characteristics of Hollow Rectangular Sectional Piers with Reduced Lateral Reinforcements (횡방향철근이 감소된 중공사각단면 교각의 내진거동 특성)

  • Sun, Chang-Ho;Kim, Ick-Hyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.51-65
    • /
    • 2009
  • The seismic design concept of RC bridges is to attain the proper ductility of piers, yielding a ductile failure mechanism. Therefore, seismic design force for moment is determined by introducing a response modification factor (R), and lateral reinforcements to confine core concrete are specified in the current design code. However, these design provisions have irrationality, which results in excessive amounts of lateral reinforcements for columns in Korea, which are generally designed with large sections. To improve on these provisions, a new design method based on seismic performance has been proposed. To apply this to hollow sectional columns, however, further investigations and improvements must be performed, due to the different seismic behaviors and confinement effects. In this study, hollow sectional columns with different lap-splice of longitudinal bars and lateral reinforcements have been tested. Seismic characteristics and performance were investigated quantitatively. These research results can be used to derive a performance-based design for hollow sectional columns.

Behaviors of Internally Confined Hollow Reinforced Concrete Piers by Thickness of Internal Steel Tube (내부 강관 두께에 따른 내부 구속 중공 RC 교각의 거동)

  • Choi, Jun-Ho;Han, Taek-Hee;Yi, Gyu-Sei;Yoon, Ki-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.2
    • /
    • pp.333-338
    • /
    • 2007
  • An infernally confined hollow reinforced concrete pier (ICH RC pier) is hollow RC pier which has a internal steel tube to enhance its ductility and stiffness by internal confinement. In this study, the internal steel tube were changed to investigate the behavior of ICH RC pier. The behavior of internally confined hollow reinforced concrete piers were evaluated with safety ratio, ductility, total material cost, the total weight of the pier, etc. As a result of analytical study, the usage of a minimum necessary thickness of the internal steel tube the most effective. The ICH RC pier has decrease of weight compare to Solid RC pier.

  • PDF

A study on shear behavior characteristics of RC hollow rectangular sectional piers (RC 중공구형단면 교각의 전단거동특성에 관한 연구)

  • Jung, Ji-Hwan;Sun, Chang-Ho;Kim, Ick-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.113-116
    • /
    • 2008
  • In recent the construction of bridges having hollow sectional piers is gradually increasing since the hollow section is more effective than solid section in resistance against seismic load. It is, therefore, very important to understand the behavior of columns with hollow sections in seismic design. However, many past researches were concentrated only on the flexural deformability of them. In this study the shear characteristics of them have been studied with scale model tests. 7 models having different void and aspect ratios were designed and tested to investigate the effect of them on shear capacities. And then the validity of empirical equations to predict shear capacity was investigated compared with the test results. The test result 80 percent of the valid area of cross section should be adequate. And compared to the proposed four model the experimental shear capacities are in good agreement with the UCB.

  • PDF

Behavior of Solid and Hollow Rectangular RC Piers with 50% of Lap-Spliced Longitudinal Bars (50%주철근 겹침이음을 갖는 중실 및 중공 사각단면 교각의 거동특성)

  • 김익현;이종석;이윤복;김원섭;선창호
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.5
    • /
    • pp.25-35
    • /
    • 2003
  • Scale model tests were performed to investigate the seismic behavior of the solid and hollow rectangular RC piers with 50% of lap-spliced longitudinal bars in plastic hinge regions. Continuous bars and lap-spliced ones with a lap length of 39 times the bar diameter were arranged alternately in the sections. In order to clarify the influence of lap splice on a ductility the effect of axial force and lateral confinement were excluded in the test. The typical flexural failure conducting a ductile behavior were observed in both models. It is confirmed that the 50% of lap-spliced bars can be considered as an alternative of seismic detailing for longitudinal bars.

Quasi-Static Test for Seismic Performance of Circular Hollow RC Bridge Pier (원형 중공 콘크리트 교각의 내진성능에 대한 준정적 실험)

  • 정영수;한기훈;이강균;이대형
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.2
    • /
    • pp.41-54
    • /
    • 1999
  • Because of relatively heavy dead weight of concrete itself and unavoidable heat of massive concrete in bridge piers, circular hollow columns are widely used in Korean highway bridges. Since the occurrence of 1995 Kobe earthquake, there have been much concerns about seismic design for various infrastructures, inclusive of bridge structures. It is, however, understood that there are not much research works for nonlinear behavior of circular hollow columns subjected to eqrthquake motions. The objective of this experimental research is to investigate nonlinear behavior of circular hollow reinforced concrete bridge piers under the quasi-static cyclic load, and then to enhance their ductility by strengthening the plastic hinge region with glassfiber sheets. Particularly for this test, constant 10 cyclic loads have been repeatedly actuated to investigate the magnitude of strength degradation for the displacement ductility factor. Important test parameters are seismic design, confinement steel ratio, axial force and load pattern. It is observed from quasi-static tests for 7 bridge piers that the seismically designed columns and the retrofitted columns show better performance than the nonseismically designed colums, i.e. about 20% higher for energy dissipation capacity and about 70% higher for curvatures.

  • PDF

Failure Behavior of Hollow Circular RC Column According to the Spacing of Spirals (나선철근 간격에 따른 중공 원형 RC 기둥의 파괴거동)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.6
    • /
    • pp.46-55
    • /
    • 2016
  • Three small scale hollow circular reinforced concrete columns(4.5 aspect ratio) were tested under cyclic lateral load with constant axial load. Diameter of section is 400 mm, hollow diameter is 200 mm. The selected test variable are transverse steel ratio. Volumetric ratio of spirals of all the columns is 0.302~0.604% in the plastic hinge region. It corresponds to 45.9~91.8% of the minimum requirement of confining steel by Korean Bridge Design Specifications, which represent existing columns not designed by the current seismic design specifications or designed by seismic concept. The final objectives of this study are to provide quantitative reference data and tendency for performance or damage assessment based on the performance levels such as cracking, yielding, steel fracture, etc. In this paper, describes mainly failure behavior, strength degradation behaviour, displacement ductility of circular reinforced concrete bridge columns with respect to test variables.

Confining Stress of Internally Confined Hollow CFT Member Under Compression (압축을 받는 내부 구속 중공 CFT부재의 구속력 평가)

  • Yoon, Na Ri;Won, Deok Hee;Park, Jong Gun;Kang, Young Jong
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.37-37
    • /
    • 2011
  • 최근 세계적인 지진의 발생과 함께 구조물의 내진성능 평가 및 증진 방법에 대하여 많은 연구가 진행 되고 있다. 특히 교량 구조물의 교각의 경우에는 상부구조의 고정하중 및 활하중을 지반에 전달하여 주는 역할을 하기 때문에, 역으로 지진이 발생하였을 경우 교각의 내진성능에 따라서 교량의 안전도에 많은 영향을 미칠 수 있다. 또한 산악지역이 국토의 70%이상을 차지하는 우리나라의 지형적인 특성상 고교각을 이용한 장대교량의 건설이 필요하며 도시지역의 교통량 증가로 인한 도시고속도로의 건설 등 고가교의 필요성이 점차 증가하고 있다. 그러나 CFT(Concrete Filled Tube)부재의 경우에는 콘크리트가 3축 구속 상태로 존재하지만 자중이 크며 내진 성능이 떨어지는 단점을 가지고 있다. 이러한 단점을 보완하기 위하여 CFT부재의 단면을 중공으로 만듦으로써 부재를 경량화하고 내부 튜브를 삽입하여 내부를 구속 시킨 내부 구속 중공 CFT 부재(Internally Confined Hollow CFT Member, ICH CFT)가 개발되었다. 이는 콘크리트가 내 외부 튜브에 의하여 구속되어 3축 구속 상태로 존재함으로써 콘크리트 중공부로의 취성파괴를 방지하여 연성도 및 강도를 향상시켜주며, 단면의 감소로 인해 재료비를 절감 할 뿐 아니라 자중 감소로 인해 내진 설계에도 유리하다. 현재 내부 구속 중공 CFT 부재에 대한 연구가 많이 진행되고 있지만, 튜브를 삽입함으로써 부재의 중공부로 발생하는 구속력의 특성을 해석적으로 정립한 연구는 미비한 실정이다. 본 연구에서는 압축을 받는 중공 CFT 부재에 내부 튜브를 삽입함으로써 발생하는 콘크리트의 구속력을 해석적 연구를 통하여 수행하였으며, 구속력을 파악하기 위한 평가 방법으로는 구속 콘크리트의 중공비와 직경, 외부튜브의 두께, 내부튜브의 두께 등으로 평가하였다. 해석적 연구 결과, 내부 튜브를 삽입함으로써 발생되는 외부 구속력은 이론적 수식에 의한 구속 응력값과 비슷한 값을 가지지만 내부로 발생하는 구속력은 이론적 수식에 의한 구속 응력값에 도달하지 못하는 것을 확인할 수 있었다.

  • PDF

Experimental Study on the Failure Behavior of RC Octagonal Hollow Section Columns with Aspect Ratio of 4.0 and Longitudinal Steel Ratio of 2.36 ~ 4.71% (형상비 4.0이고 축방향철근비 2.36 ~ 4.71%인 팔각형 중공단면 철근콘크리트 기둥의 파괴거동에 관한 실험적 연구)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.102-111
    • /
    • 2022
  • The aim of this study is to assess the seismic performance of octagonal hollow cross section reinforced concrete bridge pier, and to investigate the effect of longitudinal reinforcement ratios on the failure behavior. Four octagonal hollow section RC bridge columns of small scale model were tested under a quasi-static cyclically reversed horizontal load with constant axial load. The volumetric ratio of transverse spiral hoop of all specimens was maintained constant(0.206%), the ratios of longitudinal reinforcement were varied(2.36 ~ 4.71%). Failure behavior and seismic performance were investigated. Three specimens with the exception of lap spliced specimen showed flexure-shear failure at final stage. The test results with the exception of lap spliced specimen showed that the displacement ductility factor and accumulated energy dissipation decreased in inverse proportion to the ratio of longitudinal steel.

Development of Precast Hollow Concrete Columns with Non-Shrink Mortar Grouting Type Splice Sleeve (무수축 모르타르 충진형 슬리브를 사용한 중공 프리캐스트 교각 개발)

  • Cho, Jae-Young;Lee, Young-Ho;Kim, Do-Hak;Park, Jong-Heon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3A
    • /
    • pp.215-225
    • /
    • 2011
  • In general, the precast columns can obtain its homogeneous quality as they are produced in a factory with a hollow concrete block type by using high strength concrete, so that they can generate the reduction of dead load. Such a method of precast hollow concrete columns is already implemented in USA and Japan and used for connecting between blocks which use PC tendons. However, it is inevitable to have uneconomical construction with excessive cost in early stage when PC tendons are used. This study aims to develop an economical precast column with high quality and constructability which consists of only splice sleeve and general reinforcing bar without using PC tendons in order to reduce the construction period and cost. To achieve this goal, this study tested the performance of total 5 minimized models in the experiment with the variables such as hollowness, diameter of main reinforcement bar and cross-sectional size for the cross section of precast column by using grouting type splice sleeve which is a new type joint rebar. And it also verified the performance of column in the experiment for a large-sized model in order to overview its applicability by excluding large scale effect.

Nonlinear Finite Element Analysis of Circular Hollow Reinforced Concrete Columns Based on Design Variables (설계변수에 따른 중공원형 철근콘크리트 교각의 비선형 유한요소해석)

  • Cheon, Ju-Hyun;Lee, Seung-Jin;Lee, Byung-Ju;Lee, Jae-Hoon;Shin, Hyun-Mock
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.35-42
    • /
    • 2011
  • The seismic design of solid reinforced concrete bridge columns has been committed to, based on accumulated research and design specifications. The rational confinement model and seismic performance evaluation, however, are insufficient because of the lack of domestic and foreign design specifications about the experimental and analytical difficulties in the case of circular hollow reinforced concrete columns. In this paper, the seismic behavior of circular hollow reinforced concrete columns and its dependence on design variables are understood and explained. These research results can be used to derive the rational and economical design specifications for circular hollow sectional columns based on the result from the nonlinear analysis program, named RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology).