• Title/Summary/Keyword: 준비 오차

Search Result 74, Processing Time 0.024 seconds

Synthesis and Structural Characterization of Benzene-sorbed Cd2+-Y(FAU) Zeolite (벤젠이 흡착된 Cd2+-Y(FAU) 제올라이트의 합성 및 구조연구)

  • Moon, Dae Jun;Suh, Jeong-Min;Park, Jong Sam;Choi, Sik Young;Lim, Woo Taik
    • Journal of the Mineralogical Society of Korea
    • /
    • v.30 no.2
    • /
    • pp.45-57
    • /
    • 2017
  • Two single crystals of fully dehydrated $Cd^{2+}$-exchanged zeolites Y were prepared by the exchange of ${\mid}Na_{75}{\mid}[Si_{117}Al_{75}O_{384}]-FAU$ ($Na_{75}-Y$, Si/Al = 1.56) with aqueous $0.05M\;Cd(NO_3)_2$ (pH = 3.65) at 294 K, followed by vacuum dehydration at 723 K (crystal 1) and a second crystal, similarly prepared, was exposed to zeolitically dried benzene for 72 hours at 294 K and evacuated (crystal 2). Their structures were determined crystallographically using synchrotron X-rays and were refined to the final error indices using $F_o$>$4{\sigma}(F_o)$ of $R_1/wR_2=0.040/0.121$ and 0.052/0.168, respectively. In crystal $1({\mid}Cd_{36}H_3{\mid}[Si_{117}Al_{75}O_{384}]-FAU)$, $Cd^{2+}$ ions primarily occupy sites I and II, with additional $Cd^{2+}$ ions at sites I', II', and a second site II. In crystal $2({\mid}Cd_{35}(C_6H_6)_{24}H_5{\mid}[Si_{117}Al_{75}O_{384}]-FAU)$, $Cd^{2+}$ ions occupy five crystallographic sites. The 24 benzene molecules are found at two distinct positions within the supercages. The 17 benzene molecules are found on the 3-fold axes in the supercages where each interacts facially with one of site IIa $Cd^{2+}$ ions. The remaining 7 benzene molecules lie on the planes of the 12-rings where each is stabilized by multiple weak electrostatic and van der Waals interactions with framework oxygens.

Statistical Analysis of Operating Efficiency and Failures of a Medical Linear Accelerator for Ten Years (선형가속기의 10년간 가동률과 고장률에 관한 통계분석)

  • Ju Sang Gyu;Huh Seung Jae;Han Youngyih;Seo Jeong Min;Kim Won Kyou;Kim Tae Jong;Shin Eun Hyuk;Park Ju Young;Yeo Inhwan J.;Choi David R.;Ahn Yong Chan;Park Won;Lim Do Hoon
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.186-193
    • /
    • 2005
  • Purpose: To improve the management of a medical linear accelerator, the records of operational failures of a Varian CL2l00C over a ten year period were retrospectively analyzed. Materials and Methods: The failures were classified according to the involved functional subunits, with each class rated Into one of three levels depending on the operational conditions. The relationships between the failure rate and working ratio and between the failure rate and outside temperature were investigated. In addition, the average life time of the main part and the operating efficiency over the last 4 years were analyzed. Results: Among the recorded failures (total 587 failures), the most frequent failure was observed in the parts related with the collimation system, including the monitor chamber, which accounted for $20\%$ of all failures. With regard to the operational conditions, 2nd level of failures, which temporally interrupted treatments, were the most frequent. Third level of failures, which interrupted treatment for more than several hours, were mostly caused by the accelerating subunit. The number of failures was increased with number of treatments and operating time. The average life-times of the Klystron and Thyratron became shorter as the working ratio increased, and were 42 and $83\%$ of the expected values, respectively. The operating efficiency was maintained at $95\%$ or higher, but this value slightly decreased. There was no significant correlation between the number of failures and the outside temperature. Conclusion: The maintenance of detailed equipment problems and failures records over a long period of time can provide good knowledge of equipment function as well as the capability of predicting future failure. Wore rigorous equipment maintenance Is required for old medical linear accelerators for the advanced avoidance of serious failure and to improve the qualify of patient treatment.

Pipetting Stability and Improvement Test of the Robotic Liquid Handling System Depending on Types of Liquid (용액에 따른 자동분주기의 분주능력 평가와 분주력 향상 실험)

  • Back, Hyangmi;Kim, Youngsan;Yun, Sunhee;Heo, Uisung;Kim, Hosin;Ryu, Hyeonggi;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.62-68
    • /
    • 2016
  • Purpose In a cyclosporine experiment using a robotic liquid handing system has found a deviation of its standard curve and low reproducibility of patients's results. The difference of the test is that methanol is mixed with samples and the extractions are used for the test. Therefore, we assumed that the abnormal test results came from using methanol and conducted this test. In a manual of a robotic liquid handling system mentions that we can choose several setting parameters depending on the viscosity of the liquids being used, the size of the sampling tips and the motor speeds that you elect to use but there's no exact order. This study was undertaken to confirm pipetting ability depending on types of liquids and investigate proper setting parameters for the optimum dispensing ability. Materials and Methods 4types of liquids(water, serum, methanol, PEG 6000(25%)) and $TSH^{125}I$ tracer(515 kBq) are used to confirm pipetting ability. 29 specimens for Cyclosporine test are used to compare results. Prepare 8 plastic tubes for each of the liquids and with multi pipette $400{\mu}l$ of each liquid is dispensed to 8 tubes and $100{\mu}l$ of $TSH^{125}I$ tracer are dispensed to all of the tubes. From the prepared samples, $100{\mu}l$ of liquids are dispensed using a robotic liquid handing system, counted and calculated its CV(%) depending on types of liquids. And then by adjusting several setting parameters(air gap, dispense time, delay time) the change of the CV(%)are calcutated and finds optimum setting parameters. 29 specimens are tested with 3 methods. The first(A) is manual method and the second(B) is used robotic liquid handling system with existing parameters. The third(C) is used robotic liquid handling system with adjusted parameters. Pipetting ability depending on types of liquids is assessed with CV(%). On the basis of (A), patients's test results are compared (A)and(B), (A)and(C) and they are assessed with %RE(%Relative error) and %Diff(%Difference). Results The CV(%) of the CPM depending on liquid types were water 0.88, serum 0.95, methanol 10.22 and PEG 0.68. As expected dispensing of methanol using a liquid handling system was the problem and others were good. The methanol's dispensing were conducted by adjusting several setting parameters. When transport air gap 0 was adjusted to 2 and 5, CV(%) were 20.16, 12.54 and when system air gap 0 was adjusted to 2 and 5, CV(%) were 8.94, 1.36. When adjusted to system air gap 2, transport air gap 2 was 12.96 and adjusted to system air gap 5, Transport air gap 5 was 1.33. When dispense speed was adjusted 300 to 100, CV(%) was 13.32 and when dispense delay was adjusted 200 to 100 was 13.55. When compared (B) to (A), the result increased 99.44% and %RE was 93.59%. When compared (C-system air gap was adjusted 0 to 5) to (A), the result increased 6.75% and %RE was 5.10%. Conclusion Adjusting speed and delay time of aspiration and dispense was meaningless but changing system air gap was effective. By adjusting several parameters proper value was found and it affected the practical result of the experiment. To optimize the system active efforts are needed through the test and in case of dispensing new types of liquids proper test is required to check the liquid is suitable for using the equipment.

  • PDF

Construction and Application of an Automated Apparatus for Calculating the Soil-Water Characteristic Curve (자동 흙-함수특성곡선 시험장치 구축 및 활용)

  • Song, Young-Suk;Lee, Nam-Woo;Hwang, Woong-Ki;Kim, Tae-Hyung
    • The Journal of Engineering Geology
    • /
    • v.20 no.3
    • /
    • pp.281-295
    • /
    • 2010
  • A new, automated apparatus is proposed for calculating the Soil-Water Characteristic Curve (SWCC), representing a simple and easily applied testing device for continuous measurements of the volumetric water content and suction of unsaturated soils. The use of this apparatus helps to avoid the errors that arise when performing experiments. Consequently, the apparatus provides greater accuracy in calculating the SWCC of unsaturated soils. The apparatus is composed of a pressure panel, flow cell, water reservoir, air bubble trap, balance, sample-preparation accessories, and measurement system, among other components. The air pressure can attain 300 kPa, and a general test can be completed in a short time. The apparatus can simply control the drying process and wetting process. The changes in volumetric water content that occur during the drying and wetting processes are shown directly in the SWRC program, in real time. As a case study, we performed an SWCC test of Joomunjin sand (75% relative density) to measure matric suction and volumetric water content during both the drying and wetting processes. The test revealed hysteresis behavior, whereby the water content on the wetting curve is always lower than that on the drying curve for a specific matric suction, during the wetting and drying processes. Based on the test results, SWCCs were estimated using the Brooks and Corey, van Genuchten, and Fredlund and Xing models. The van Genuchten model performed best for the given soil conditions, as it yielded the highest coefficient of determination.

A Study on the Assessment of Source-term for PWR Primary System Using MonteCarlo Code (MonteCarlo 코드를 이용한 PWR 일차 계통 선원항 평가에 관한 연구)

  • Song, Jong Soon;Lee, Sang Heon;Shin, Seung Su
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.3
    • /
    • pp.331-337
    • /
    • 2018
  • The decommissioning of nuclear power plants is generally executed in five steps, including preparation, decontamination, cutting/demolition, waste disposal and environmental restoration. So, for efficient decommissioning of nuclear power plants, worker safety, effects compared to cost, minimization of waste, possibility of reuse, etc., shall be considered. Worker safety and measurement technology shall be secured to exert optimal efficiency of nuclear power plant decommissioning work, for which accurate measurement technology for systems and devices is necessary. Typical In-Situ methods for decommissioning of nuclear plants are CZT, Gamma Camera and ISOCS. This study used ISOCS, which can be applied during the decommissioning of a nuclear power plant site without collecting representative samples, to take measurements of the S/G Water Chamber. To validate the measurement values, Microshield and the GEANT4 code was used as the actual method were used for modeling, respectively. The comparison showed a difference of $1.0{\times}10^1Bq$, which indicates that it will be possible to reduce errors due to the influence of radiation in the natural environment and the precision of modeling. Based on the research results of this paper, accuracy and reliability of measurement values will be analyzed and the applicability of the direct measurement method during the decommissioning of NPPs will be assessed.

Application of Statistical Analysis for Optimization of Organic Wastes Acidogenesis (유기성 폐기물의 산발효 최적화를 위한 통계학적 분석 방안의 적용)

  • Jeong, Emma;Kim, Hyun-Woo;Nam, Joo-Youn;Oh, Sae-Eun;Hong, Seung-Mo;Shin, Hang-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.8
    • /
    • pp.781-788
    • /
    • 2008
  • This study shows how to find out optimum co-substrate conditions and continuous operating parameters for maximum acidification of three different organic wastes - livestock wastewater, sewage sludge and food waste. Design of experiments and statistical analysis were revealed as appropriate optimization schemes in this study. Analyses of data obtained from batch tests demonstrated the optimum substrate mixing ratio, which was determined by maximum total volatile fatty acids(TVFA) increase and soluble chemical oxygen demand(SCOD) increase simultaneously. Suggested optimum mixing ratio of livestock wastewater, sewage sludge and food waste was 0.4 : 1.0 : 1.1 based on COD, respectively. Response surface methodology(RSM) contributed to find out optimum operating parameter - hydraulic retention time(HRT) and substrate concentration - for the semi-continuous acidogenic fermentation of mixed organic wastes. The optimum condition for maximum TVFA increase was 2 days of HRT and 29,237 mg COD/L. Empirical equations obtained through regression analysis could predict that TVFA increase would be 73%. To confirm the validity of the statistical experimental strategies, a confirmation experiment was conducted under the obtained optimum conditions, and relative error between theoretical and experimental results was within 4%. This result reflects that using statistical and RSM technique can be effectively used for the optimization of real waste treatment processes.

Comparative Study on the Adsorptive Loss of Reduced Sulfur Compounds (RSC) by the Selection of Tubing Materials (튜빙의 종류에 따른 환원황화합물들의 흡착손실 비교 연구)

  • Kim Ki-Hyun;Ahn Ji-Won;Choi Ye-Jin
    • Journal of the Korean earth science society
    • /
    • v.26 no.7
    • /
    • pp.668-673
    • /
    • 2005
  • To collect or transfer samples of gaseous pollutants, various types of tubing are used. Hence, to analyze the uncertainties associated with the use of tubings, a series of comparative test were designed and conducted using the RSC standards with different concentration ranges. For the purpose of this study, we prepared tubings made of six different types of material which include: [1] silco-steel (S1), [2] stainless steel (S2), [3] silicone (S3), [4] PTFE Teflon (T1), [5] tygon (T2), and [6] brass (B). The patterns of RSC loss on to tubing walls, when compared on the basis of the least reactive material S1, exhibited that the extent of RSC loss varied dynamically. It was found that Teflon is highly stable. However, other materials tend to exhibit contrasting patterns of loss. S2 and B show significant loss of light RSC $(H_2S\;and\;CH_3SH)$, while S3 and T2 experience notable loss of heavy RSC (DMS and DMDS).

Evaluation of Shrinkage Strain of Alkali-Activated Slag Concrete (알칼리활성 슬래그 콘크리트의 건조수축 변형률 평가)

  • Yang, Keun-Hyeok;Seo, Eun-A
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.6
    • /
    • pp.593-599
    • /
    • 2013
  • The unrestrained shrinkage strain of alkali-activated (AA) slag concrete was examined and compared with design equations specified in code provisions and empirical equations proposed by Yang et al. The main parameters investigated were the water-to-binder ratio (W/B), unit water content and fine aggregate-to-total aggregate ratio (S/a). Test results revealed that shrinkage strain of AA slag concrete is nearly proportional to the W/B ratio, whereas its time function is independent of the W/B ratio. The shrinkage strain of AA slag concrete increased significantly when the unit water content is above $185kg/m^3$, whereas it is marginally affected by the S/a ratio. The design equation of ACI 209 considerably overestimates the shrinkage behavior of AA slag concrete, whereas CEB-FIP equation tends to underestimate the shrinkage at the age more than 28 days. The empirical equation of Yang et al. is in better agreement with test results, showing that values of mean and standard deviation of error coefficients obtained from each specimen are 016 and 0.07, respectively.

Determination of Uranium Isotopes in Spent Nuclear Fuels by Isotope Dilution Mass Spectrometry (동위원소희석 질량분석법을 이용한 사용후핵연료 중 우라늄 동위원소 정량)

  • Kim, Jung Suk;Jeon, Young Shin;Son, Se Chul;Park, Soon Dal;Kim, Jong Goo;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.450-457
    • /
    • 2003
  • The determination of uranium and its isotopes in spent nuclear fuels by isotope dilution mass spectrometry (IDMS) has been studied. The spent fuel samples were dissolved in 8 M $HNO_3$ or its mixture with 14 M $HNO_3-0.05M$ HF. The dissolved solutions were filterred on membrane filter with $1.2{\mu}m$ pore size. The uraniums in the spiked and unspiked sample solutions were quantitatively adsorbed by anion exchange resin, AG 1X8 and eluted with 0.1 M HCl. The contents of uranium and its isotopes ($^{234}U$, $^{235}U$, $^{236}U$$^{238}U$) in the spent fuel samples were determined by isotope dilution mass spectrometric method using $^{233}U$ as spike. The spike reference solution was standarized by reverse isotope dilution mass spectrometry (R-IDMS) using natural and depleted uranium. The results from IDMS were in average relative difference of 0.34% when compared with those by the potentiometric titration method.

Analysis of High School Science Textual Descriptions of Scientifically Debatable Compounds According to the Experimental Results by MBL: A Case Study of Carbonic Acid in Water and Aqueous Solution of Carbon Dioxide (MBL 실험 결과를 토대로 한 과학적으로 논의 되고 있는 화합물의 고등학교 과학 교과서 기술 분석: 이산화탄소 수용액과 탄산 수용액의 경우)

  • Jeoung, Jee-Young;Min, Kyeong-Jin;Chae, Hee-K.
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.4
    • /
    • pp.479-486
    • /
    • 2010
  • The purposes of this study are to investigate the description of scientifically debatable carbonic acid in the Korean high school textbooks, characterize the physical properties of 'carbonic acid solutions' by using an MBL set-up and compare the properties with textual ones. Four different aqueous solutions of carbon dioxide have been prepared and analyzed: naturally aerated aqueous solution, dry ice-dissolving solution, $CO_2$-bubbling solution and commercial carbonic acid water. Experimental findings showed that pH and conductivity of these 4 solutions ranged from 3.85 to 5.66 and from 0.21 ${\mu}S$/cm to 272.1 ${\mu}S$/cm, respectively. Out of these solutions, the dissociation constant($K_{a1}$) of the bubbling solution at room temperature could be calculated to $5.7{\times}10^{-7}$ which value is comparable to the textual $4.3{\times}10^{-7}$ within experimental errors, which means that textual compound is not pure carbonic acid but the equilibrated mixture of carbonic acid and the aqueous solution of carbon dioxide. On the other hand, textual analysis showed that most of high school textbooks used carbonic acid as an example of weak acid and buffer solution of the blood but none of them distinguished the carbonic acid from the aqueous solution of carbon dioxide. Only one textbook, however, tiered two species in the chemical equation.